Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹96,590.40Accepted-Finance | 1 | Accepted-Finance L1 | |
| 2 | 2₹1.2 L+₹19,659.40 (20.4%)Accepted-Finance | 2 | Accepted-Finance L2 | |
| 3 | 3₹1.2 L+₹22,941.60 (23.8%)Accepted-Finance | 3 | Accepted-Finance L3 | |
| 4 | 4₹1.2 L+₹23,937.60 (24.8%)Accepted-Finance | 4 | Accepted-Finance L4 | |
| 5 | 5₹1.3 L+₹34,862.40 (36.1%)Accepted-Finance | 5 | Accepted-Finance L5 |
Tender Value
₹2 L
EMD Value
₹2,000
Closing Date
8 Jun 2020, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
S.E. EDC-1 MORADABAD
MORADABAD
DIFFERENT WORKS IN SYSTEM IMPROVEMENT AND INCREASING CAPACITY SCHEMES UNDER THE AREA OF EDD-2 MORADABAD
2020_PVVNL_474835_1
13/2020-21/EDC1M
Open Tender
Electrical Works
Lump-sum
30 days
MORADABAD
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
S.E. EDC-1 MORADABAD
₹2,000
10 Jun 2020
26 May 2020
9 Jun 2020
26 May 2020
8 Jun 2020
26 May 2020
90 days
Amount
Carriage of the following material from Store Centre, Majhola/JE’s Store to site of work with loading & unloading at both ends (distance about 40 km.)
(a) PCC Poles 8.50 meter long.
(b) ACSR Weasel conductor.
(c) 11/0.4 KV 100 KVA transformer.
(d) 11/0.4 KV 63 KVA transformer.
(e) 11KV VCB I/C CTR 600/300/5A
(f) LT AB cable of size 3x50+1x35+1x16 sqmm.
(g) Line material such as Cross-Arm, Pin Insulators, Disc Insulators and G.I. wire earth rod, top channel, stay rod etc as per estimate.
FOR 11 KV LINE, Double pole structure with 11 Mtr long Pole:- Excavation of foundation pit in size of 75x45cm having depth of 1/6th of the full length of the support (pole) Erection of support (pole) complete work by providing stone, sand cement etc, fixing of D.P. Clamps and all other accessories .The work includes fabrication work and fixing of cross bracing sets ,cutting holes complete work as per RESPO Norms.
FOR 11 KV LINE, Single support with 8.5 mtr long PCC Pole:- Excavation of foundation Pit in size of 75x45cm having depth of 1/6th of the full length of the support (pole), providing and laying of stone pad (300x300x75 mm) in the Bottom of the pit. Erection of support (pole) complete with fixing of 11 KV V-type cross-Arms and other accessories by providing stone pad, cross arm holding clamps, f-bracket and Nuts & Bolts as per RESPO Norms.
Grouting of Stay Rods (20x1800)mm including all work of excavation, cement concrete in size of (0.60x0.60x0.30)M in the ratio of 1:4:6(cement, sand, 40mm brick ballast) including back filling of soil and proper ramming etc.
Fixing, tightening and nozelling of stay wire with stay rod and stay insulators with the pole of required tension by providing stay clamps, Nuts&Bolts etc.
Earthing of support with MS Earth Rod of (20x2500)mm long including excavation of pit and driving MS Rod 3.0 M apart from support and 0.5 M below the ground level and connecting below the earth electrodes with the help of GI wire No. 6 SWG tightening with nuts and bolts.
Grouting of PCC poles 8.50 Meter long single line support:- Grouting of support in CC 1:4:6 (cement, sand & 40 mm. brick ballast) Grouting will be done in the block of size 45x45cmx1/6th of full length of the support upto ground level as per RESPO Norms.
Laying, sagging, stringing and binding of ACSR Weasel Conductor with other accessories on poles as per RESPO Norms.
Laying, sagging, straightening of LT AB cable of size 3x50+1x35+1x16 sqmm. with other accessories on poles as per RESPO Norms.
Installation of new 11KV VCB I/C CTR 600/300/5A at substation bheetkhera, complete work as per norms.
Providing & Fixing of Danger board on pole as per norms.
Guarding of lines as per RESPO norms.
Dismounting of 25 KVA transformer from double pole including opening connection as per Norms.
Dismounting of 63 KVA transformer from double pole including opening connection as per Norms.
Mounting & fixing of 100 KVA on double pole including making proper connections as per RESPO Norms.
Mounting & fixing of 63 KVA on double pole including making proper connections as per RESPO Norms.
Carriage of ACSR/G.I. etc scrap from site of work to Store Centre, Majhola with loading & unloading at both ends (distance about 40 km.)
Carriage of damaged 11KV VCB I/C CTR 600/300/5A from site of work to Store Centre, Majhola with loading & unloading at both ends (distance about 40 km.)
Carriage of 11/0.4 KV 63 KVA transformer (01 Nos) & 25 KVA Transformer (02 Nos) from site of work to Store Centre, Majhola with loading & unloading at both ends (distance about 40 km.)
M/S B S TRADERS AND CONTRACTOR
Maksood Ali Contractor
FANCY TRADERS
M/S PASA TRADING COMMISSION AGENT
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .