Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.9 LAccepted-AOC H NO 787 22 JHANG COLONY NEAR FOREST DEPARTMENT OFFICE ROHTAK 124001 | ROHTAK | ROHTAK | HARYANA | 124001 | L1 | Accepted-AOC accepted | |
| 2 | L2₹10.8 L+₹90,471 (9.12%)Rejected-AOC H NO 959 SECTOR 3 ROHTAK | L2 | Rejected-AOC rejected |
| Sl No | Description | Qty | Unit | DEVENDER KUMAR CONTRACTOR L2 | M/s Sanjay Kumar L1 |
|---|---|---|---|---|---|
| 1.00HSR Items | |||||
| 1.01 | [23.22.1.9]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.9. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 6 amp to 100 amp , 25 KA [Through Rate] | 1 | Each | 4,500 ₹4,500 | 2,500 ₹2,500 Lowest |
| 2.00 | [23.22.2.1]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 2.1. MCCB Enclosure made of Sheet Steel suitable for mounting MCCB of following ratings MCCB up to 125 A FP [Through Rate] | 1 | Each | 1,900 ₹1,900 Lowest | 2,000 ₹2,000 |
| 3.00 | [23.23.6.1]MISCELLANEOUS 6.1. Supply and erection of MS cable tray , duly pained as required including erection of the same on wall or ceiling with necessary fixture and other material required to complete the job in all respect up to the entire satisfaction of Engineer-in Charge of the work. MS perforated cable tray painted with powder coating 100 X 50 X 2 mm [Through Rate] | 20 | P.Metre | 260 ₹5,200 Lowest | 262 ₹5,240 |
| 4.00 | [23.23.7.1]MISCELLANEOUS 7.1. Supply and erection of cable tray cover made of 1.25 mm thick GI sheet as required including erection of the same on existing cable tray with necessary fixture and other material required to complete the job in all respect up to the entire satisfaction of Engineer-in Charge of the work. GI cable tray Cover , suitable for cable tray of 100 X 50 X 2 mm [Through Rate] | 20 | P.Metre | 225 ₹4,500 | 161 ₹3,220 Lowest |
| 5.00 | [23.5.1.2]COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS 1.2. Wiring only in 1.5 sqmm PVC insulated copper conductor cable for LIGHT/FAN/Call bell point in existing conduit pipe and MS boxes including cost of Bakelite cover for MS box, switch, wall socket, ceiling rose/connector etc. Group B [Through Rate] | 40 | Each | 350 ₹14,000 | 327 ₹13,080 Lowest |
| 6.00 | [23.5.4.2]COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS 4.2. Wiring in existing conduit and MS box for 3-pin 5amp. Plug point by using 2 no 1.5 sqmm FRLS copper wire and 1 no 1.5 Sqmm FRLS copper wire , including providing 1 no 5/6 Amp 3/5 pin socket and 1 no 5/6 Amp switch etc complete as required Group B [Through Rate] | 40 | Each | 450 ₹18,000 Lowest | 450 ₹18,000 Lowest |
| 7.00 | [23.5.5.2]COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS 5.2. Wiring in existing conduit system for 3-pin 15amp. Plug point by using 2 no 4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire for earthling , including providing 1 no 15/16 Amp 3/6 pin socket and 1 no 15/16 Amp switch etc complete as required Group B [Through Rate] | 35 | Each | 775 ₹27,125 Lowest | 1,200 ₹42,000 |
| 8.00 | [23.5.6.1]COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS 6.1. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 1.50 Sqmm(1/1.40mm) [Through Rate] | 410 | P.Metre | 65 ₹26,650 Lowest | 65 ₹26,650 Lowest |
| 9.00 | [23.5.6.3]COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS 6.3. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 4 Sqmm(1/2.24mm) [Through Rate] | 240 | P.Metre | 125 ₹30,000 Lowest | 167 ₹40,080 |
Tender Value
₹10.0 L
EMD Value
₹19,960
Closing Date
17 Oct 2025, 5:00 pmClosed
AMIT GOYAL
ED - Rohtak
Renovation of I.C.U at Distt. Civil Hospital, at Rohtak (Pdg. E.I, DG set and R.O with water cooler only)
2025_HRY_477428_1
20251AFC5B85 43BE 4BE6 A322 AE97F0E83335667BAR
Open Tender
Electrical Works
Works
90 days
Rohtak
Technical documents as per approved DNIT conditions.
3 documents required · 3 mandatory
₹1,000
₹19,960
Yes
20 Nov 2025
10 Oct 2025
21 Oct 2025
10 Oct 2025
17 Oct 2025
10 Oct 2025
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Document
1.13 MB
BOQ
BOQ • 0.29 MB
Additional Documents
Additional Documents • 2.48 MB
Other Document
Other Document • 0.84 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .