Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.5 LAccepted-AOC | L1 | Accepted-AOC Awarded being lowest bidder | |
| 2 | L2₹42.5 L+₹1.9 L (4.72%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹43.6 L+₹2.9 L (7.21%)Rejected-AOC | L3 | Rejected-AOC Rejected | |
| 4 | L4₹44.1 L+₹3.5 L (8.52%)Rejected-AOC | L4 | Rejected-AOC Rejected | |
| 5 | L5₹44.4 L+₹3.8 L (9.38%)Rejected-AOC | L5 | Rejected-AOC Rejected |
Tender Value
₹46 L
EMD Value
₹92,000
Closing Date
16 Jun 2020, 6:00 pmClosed
Garrison Engineer North Ahmednagar
Military Engineer Services Garrison Engineer North Nagar-Pathardi Road Opp Ahmednagar Fort Ahmednagar-414002
Provision of certain sanctioned and special repairs works in the area of AGE B/R II under GE (N) Ahmednagar
2020_MES_331887_2
8412 / E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Ahmednagar
Class D Cat a (i)
8 documents required · 8 mandatory
₹500
Yes
Garrsion Engineer North Ahmednagar
₹92,000
Yes
23 Jun 2020
9 May 2020
18 Jun 2020
9 May 2020
16 Jun 2020
3 Jun 2020
Amount
Dismantling of stone slab & tiles of any description in floor, laid, bedded & pointed in any mortar. In any situation etc complete all as specified and directed by Engineer-in-Charge
Demolition of cement concrete (un-reinforced) in ground floor & paving n.exc. 15cm thick below or above ground level etc complete all as specified and directed by Engineer-in-Charge
Dismantling Asbestos cement (corrugated, Semi corrugated etc.) sheets in roof coverings etc complete all as specified and directed by Engineer-in-Charge
Taking down chowkats (without taking off shutters from frames) n exc 1.50sqm etc complete all as specified and directed by Engineer-in-Charge
Taking down chowkats (without taking off shutters from frames) exc 1.50sqm and n exc 4 sqm each etc complete all as specified and directed by Engineer-in-Charge
Taking down cement mortar plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed by Engineer-in-Charge
S&F sinks with drainage board made of stainless steel 1 mm thick kitchen or laboratory with plug, washers and waste including bedding in cement mortar to dwarf wall or including fixing contiliver brackets and connecting union to pipe overall size 915 x 510 mm bowl size 510 x 410 x 200 mm including waste coupling, waste pipe etc complete all as specified and directed by Engineer-in-Charge.
S&F wash hand basin vitreous China white , flat back or angle type of size 550 X 400 mm including pillar tap 15mm dia CP of make Jaguar Cat No FON-40011 , waste chain and plug and porcelain stopper , waste pipe, a pair of brackets, or erecting stand and PVC connection etc complete all as specified and directed by Engineer-in-Charge Make :- Cat Part No C0471 (CHT) Indus series Of Parryware or equivalent in Hindware Ist quality / Cera
S&F CP bib tap, 15 mm dia with wall flange screwed down for iron pipe or for brass ferrule etc complete all as specified and directed by Engineer-in-Charge. Make:- Cat part No MOR 1020 A(Oriental series) of MARC or equivalent in Plumber / ESS-ESS. /Jaquar Cat No ARI 39037
S&F 32 mm dia PVC pipe (outlet ) plain fixed to waste coupling of WHB or Sink etc complete all as specified and directed by Engineer-in-Charge
Excavation in post holes each n exc 0.5 cum getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, in soft/ loose soil etc complete all as specified and directed by Engineer-in-Charge
M&L for providing plain cement concrete (1:3:6) type B2 (40mm graded stone aggregate) as in foundation/ post etc complete all as specified and directed by Engineer-in-Charge
S&F steel work in tubular trussed including special shaped washer using ERW or induction butt welded tubes conforming to IS 1161:1998 etc complete all as specified and directed by Engineer-in-Charge
S&F pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws etc complete all as specified and directed by Engineer-in-Charge
M&L for pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an color having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, color and design as etc complete all as specified and directed by Engineer-in-Charge and as approved by GE
M&L preparation of new steel surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over one coat of red oxide primer etc complete all as specified and directed by Engineer-in-Charge
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in any type of soil etc complete all as specified and directed by Engineer-in-Charge
M&L for cement concrete type D2 (1:4:8) using 40 mm graded stone aggregate in foundations, filling and mass concrete etc complete all as specified and directed by Engineer-in-Charge
M&L for RCC nominal Mix type B1 (1:2:4) using 20 mm graded stone aggregate in foundations, footings, plinth beams or similar works etc complete all as specified and directed by Engineer-in-Charge
Use and waste formwork to sides of concrete foundations, footings, bases of columns and plinth beams; and similar work etc complete all as specified and directed by Engineer-in-Charge
M&L for RCC nominal Mix type B-1 1:2:4 using 20 mm graded stone aggregate in columns, pillars or similar works etc complete all as specified and directed by Engineer-in-Charge
Formwork to sides of pillars, posts,, columns and similar works etc complete all as specified and directed by Engineer-in-Charge
Use and waste formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) etc complete all as specified and directed by Engineer-in-Charge
M&L for RCC nominal Mix type B-1 1:2:4 using 20 mm graded stone aggregate in slabs supported on walls, beams and columns in floors, roofs and the like works etc complete all as specified and directed by Engineer-in-Charge
Use and waste formwork to roof beams including supports, overhangs, etc complete all as specified and directed by Engineer-in-Charge
M&L for RCC nominal Mix type B1 (1:2:4) using 20 mm graded stone aggregate in Beams, lintels over 1.5m span etc complete all as specified and directed by Engineer-in-Charge
M&L for Mild steel bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips
All as per item No.27 (here-in-before) but 6 to 8 mm dia.
All as per item No.27 (here-in-before) but 8 mm dia and over up to and incl 10 mm dia in stirrups, spacers and binders
M & L for brickwork with fly ash modular brick, straight or curved on plan exc 6m mean radius, built in built in cement and sand mortar (1:6) etc complete all as specified and directed by Engineer-in-Charge
M&L for brickwork with fly ash modular bricks, straight or curved on plan to any radius in half brick thick walls, built in cement and sand mortar (1:6) etc complete all as specified and directed by Engineer-in-Charge
M&L for rendering 10mm thick in cement and sand mortar (1:6) on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement and applying sagol finish etc complete all as specified and directed by Engineer-in-Charge
M&L for rendering 15mm thick in cement and sand mortar (1:4) of brick work or concrete surfaces finished surfaces even and fair without using extra cement
M&L for 10 mm cement and sand mortar (1:3) using 100% coarse sand on roof mixed with and including WPC @ 3% by weight of cement and finishedthe surface even and smooth with extra cement etc complete all as specified and directed by Engineer-in-Charge.
Material and labour for providing water proofing treatment on roofs, as per manufacturer's instructions and as specified after taking down/out as existing at site :- (a) Cleaning the newly plastered surfaces with wire brushes and applying a coat of bituminous primer @ 0.30 ltrs/sqm and allow to dry. (b) Applying and laying torch APP polymer modified bituminous membrane 3 mm thick with non woven polyester matt as reinforced weighing not less than 3 kg/sqm by thermo fusion process as per manufacturers specification including applying one coat of aluminum paint. Make : Super Thermolay of STP / Equivalent in TEXSA, FosRoc.
M&L for preparation of newly plastered surface of wall and applying three coat of white wash etc complete all as specified and directed by Engineer-in-Charge
M&L for preparation of newly plastered surface of ceiling and applying three coat of white wash etc complete all as specified and directed by Engineer-in-Charge
M&L for preparation of newly plastered surface of wall apply two coats of cement base paint over one coat of primer etc complete all as specified and directed by Engineer-in-Charge
M&L for steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded etc complete all as specified and directed by Engineer-in-Charge
M&L for steel ventilator with top hung shutter including hinges, steel peg stay, etc complete all as specified and directed by Engineer-in-Charge
S&F of framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes and similar work con- forming to Fe.290.Gde-E-165 etc complete all as specified and directed by Engineer-in-Charge
M&L for preparation of newly steel surface of any description and apply two coats of synthetic enamel paint over one coat of red oxide area exc 10cm in width or girth, not otherwise described etc complete all as specified and directed by Engineer-in-Charge
M&L for sheet glass 3 mm thick , ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane etc complete all as specified and directed by Engineer-in-Charge
M&L for moorum/red bajri filling in floors or paving's, laid in layers n exc. 15 cm thick, spread, leveled and rammed including watering etc complete all as specified and directed by Engineer-in-Charge
M&L for hardcore of gauge exc 63mm but n exc. 100 mm, deposited, spread and leveled in layers n exc. 15 cm thick, watered and rolled/rammed to a true surface etc complete all as specified and directed by Engineer-in-Charge
M&L for 75 mm thick PCC type C2, (1:3:6) (40mm graded stone aggregate) as in plinth protection etc complete all as specified and directed by Engineer-in-Charge
M&L for 75 mm thick PCC type D-2, (1:4:8) (40mm graded stone aggregate) as in sub base etc complete all as specified and directed by Engineer-in-Charge
M&L for 25 mm thick PCC type B0, (1:2:4) (12.5mm graded stone aggregate) as in floors etc complete all as specified and directed by Engineer-in-Charge
Material and labour for joint free / rectified anti skid ceramic colored tiles digitally printed premium series matching to wall tiles, makes as specified in PS, 7-8 mm thick as approved by GE (square / rectangular) area of each tile exc 0.06 Sqm but not exc 0.11 Sqm, as in floor etc laid over and including screed bed 15 mm thick in cement mortar 1:6 set and jointed with white or colored cement to match etc complete all as specified and directed by Engineer-in-Charge
All as per item No. 49 (here-in-before) but in skirting over 10 mm thick backing in cement and sand mortar (1:4) etc complete all as specified and directed by Engineer-in-Charge
Material and labour for joint free / rectified anti skid ceramic coloured tiles digitally printed premium series matching to wall tiles, makes as specified in PS, 7-8 mm thick as approved by GE (square / rectangular) area of each tile exc 0.18 Sqm but not exc 0.38 Sqm, as in floor etc laid over and including screed bed 15 mm thick in cement mortar 1:6 set and jointed with white or coloured cement to match etc complete all as specified and directed by Engineer-in-Charge
Material and labour for coloured glazed ceramic tiles digitally printed premium designer series of size exc 0.12 Sqm and n'exc 0.18 Sqm , 8-10 mm thick as approved by GE as in dado/skirting or on vertical surfaces, over and including 10 mm thick backing coat in cement mortar 1:4 set and jointed in neat cement slurry and pointed in white or coloured cement to match etc complete all as specified and directed by Engineer-in-Charge
S&F 35 mm thick Plain framed, paneled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial plywood . The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated etc complete all as specified and directed by Engineer-in-Charge
S&F factory Made Solid PVC Molded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick 3D wood grain Molded PVC Sheet Polyurethane painted on the front face & 2mm prelam PVC Sheet on back face, supplying & fixing in frame at site as per specification & drawing etc complete all as specified and directed by Engineer-in-Charge
S&F of solid PVC door frame 2mm thick 3D wood grain Molded PVC Sheet Polyurethane painted on the front face & 2mm prelam PVC Sheet on back face etc complete all as specified and directed by Engineer-in-Charge
S&F of 125x 60 mm pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified including filling of frame by PCC (1:3:6) etc complete all as specified and directed by Engineer-in-Charge
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm etc complete all as specified and directed by Engineer-in-Charge
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point etc complete all as specified and directed by Engineer-in-Charge
M & L for preparation of new wooden surface and applying two coats of synthetic enamel paint over one coat of pink primer etc complete all as specified and directed by Engineer-in-Charge
S&F of 100 mm size butt hinges, medium weight, cold rolled mild steel, and fixed etc complete all as specified and directed by Engineer-in-Charge
S&F aluminum barrel tower bolts of extruded section 150mm long etc complete all as specified and directed by Engineer-in-Charge
S&F aluminum handle anodized fabricated type of size 150 mm etc complete all as specified and directed by Engineer-in-Charge
S&F aluminum alloy anodized sliding door bolts with hasp & staples and fixing clips bolts etc length of bolt 300 mm etc complete all as specified and directed by Engineer-in-Charge
Supply and fix vitreous China white squatting pan, Orissa pattern of size 580 X 440 mm width with integral foot rest set in cement concrete including flush pipe and connecting to trap / including flushing cistern etc complete all as specified and directed by Engineer-in-Charge. Make :- Cat Part No C0117 of Parryware or Cat Part No 20042 of Hindware or equivalent in Cera
M&L for Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to concealed water tubing or similar works etc, and making good, cutting not exc 10 cm girth etc complete all as specified and directed by Engineer-in-Charge
M & L for 15 mm bore GI tubing medium grade with all fitting and fixed complete on walls and ceilings or laid in floors etc complete all as specified and directed by Engineer-in-Charge
M & L for 20 mm bore GI tubing medium grade with all fitting and fixed complete on walls and ceilings or laid in floors etc incl taking down old, etc complete all as specified and directed by Engineer-in-Charge
Supply and fix rotational moulded polyethylene water storage tanks double layer ISI marked conforming to IS 12701-1996 (cylindrical vertical with closed top) and made out of virgin FDA approved polyethylene material of 500 litres capacity hoisted and fixed in position including 20 mm dia ball valve, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed to iron pipe and connecting complete all as specified and directed.
Supply and fix rotational moulded polyethylene water storage tanks double layer ISI marked conforming to IS 12701-1996 (cylindrical vertical with closed top) and made out of virgin FDA approved polyethylene material of 1000 litres capacity hoisted and fixed in position including 20 mm dia ball valve, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed to iron pipe and connecting complete all as specified and directed.
S & F PVC connections 15 mm size with PTMT nuts of length 450 mm etc complete all as specified and directed by Engineer-in-Charge
S&F 15 mm bore CP stop cock fancy type screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for union and fix Make:- Cat part No MOR 1320(Oriental series) of MARC or equivalent in Plumber / ESS-ESS / Jaquare
M&L cast iron floor/Nahani trap with grating 75mm dia including jointing to waste pipe fixed in cement concrete type (1:2:4) type B1 etc complete all as specified and directed by Engineer-in-Charge
S&F 40 mm bore low density polyethylene pipes (LDPE) of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors etc complete all as specified and directed by Engineer-in-Charge
S&F 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls etc complete all as specified and directed by Engineer-in-Charge
S&F 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls etc complete all as specified and directed by Engineer-in-Charge
S&F of 75 mm bore PVC (SWR) bends with access door etc complete all as specified and directed by Engineer-in-Charge
S&F of 110 mm bore PVC (SWR) bends with access door etc complete all as specified and directed by Engineer-in-Charge
M&L 200 mm bore RCC pipe class NP2 with collars, laid and jointed etc complete all as specified and directed by Engineer-in-Charge
M&L 300 mm bore RCC pipe class NP2 with collars, laid and jointed etc complete all as specified and directed by Engineer-in-Charge
M&L 150 mm bore RCC pipe class NP2 with collars, laid and jointed etc complete all as specified and directed by Engineer-in-Charge
M&L for concrete bed to drain pipes in PCC 1:4:8 type-D2 using 40 mm graded aggregate including packing under, and haunching against the sides of pipes for 150 mm bore pipes after they are laid and tested; in etc complete all as specified and directed by Engineer-in-Charge
M&L for PCC 1:3:6 Type - C1 using 20 mm graded stone aggregate as in surface channel, benching in manhole etc complete all as specified and directed by Engineer-in-Charge
M&L for precast RCC manhole cover slab in (1:2:4) type B1 using 20 mm gramded stone aggregate including necessary form work and set in cement and sand mortar (1:6), cover slabs (for man holes etc.) etc complete all as specified and directed by Engineer-in-Charge
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred /stopped ends etc complete all as specified and directed by Engineer-in-Charge
M&L for Providing, plain cement concrete 1:2:4 type-B1 using 20 mm graded stone aggregate as in coping on top of manhole or mud stops, chamfered on edges etc complete all as specified and directed by Engineer-in-Charge
M&L for Rendering 10mm thick in cement and sand mortar (1:4) surface finished even and smooth with setting coat on fair faces of brickwork or concrete surfaces etc complete all as specified and directed by Engineer-in-Charge
Excavating over areas, n exc 1.5 m deep and getting out in any type of soil etc complete all as specified and directed by Engineer-in-Charge
Material and labour for white Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, as in floor etc laid over and including screed bed 15 mm thick in cement mortar 1:6 set and jointed with white or coloured cement to match etc complete all as specified and directed by Engineer-in-Charge
S&F Vitreous China bowl urinal flat back, size of 530 x340 x 360 mm white with grating and union for discharge pipe, urinal spreder (excluding flushing cistern, flush pipe and waste pipe). Make Jaquar Cat No URS-WHT- 707 of equivalent in Hindware / Parryware / Cera etc complete all as specified and directed by Engineer-in-Charge
S&F 16 mm dia of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors etc complete all as specified and directed by Engineer-in-Charge
S&F 20 mm dia of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors etc complete all as specified and directed by Engineer-in-Charge
S&F 16 mm dia Female Brass Threaded Adaptor (FTA/ FBTA) etc complete all as specified and directed by Engineer-in-Charge
S&F 16 mm dia Brass Elbow etc complete all as specified and directed by Engineer-in-Charge
S&F 20 mm dia male Brass Threaded Adaptor (MTA/ MBTA) etc complete all as specified and directed by Engineer-in-Charge
S&F 20 mm dia Female Brass Threaded Adaptor (FTA/ FBTA) etc complete all as specified and directed by Engineer-in-Charge
S&F 20 mm dia Brass Elbow etc complete all as specified and directed by Engineer-in-Charge
S&F 20 mm dia Brass Elbow (3/4 X ½) etc complete all as specified and directed by Engineer-in-Charge
S&F 20 mm dia Brass Tee etc complete all as specified and directed by Engineer-in-Charge
S&F 20 mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed etc complete all as specified and directed by Engineer-in-Charge
M&L machine cut cudappah stone slab 18-20 mm thick over cement screed base, laid over and including 15 mm thick screed bed in cement mortar 1:6, set and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing all as directed.
S&F stainless steel kitchen plate rack made out of 0.63 mm thick stainless steel sheet of size 36''x 36''x 10'' with complete accessories including screws etc complete all as specified and directed by Engineer-in-Charge. Make Nirali or equivalent
M&L for construction of RCC Hume pipe septic tanks designated to carry sewage and sludge water, excavation in any type of soil, PCC (1:4:8) below foundation, vent shaft, connection for 10 users as per Drg etc complete all as specified and directed by Engineer-in-Charge
S&F galvanized mild steel wire cloth 0.56 nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks or galvanized wire staples etc complete all as specified and directed by Engineer-in-Charge
Rendering 5 mm thick on fair faces of concrete on ceiling in cement and sand mortar (1:3) and finished even and smooth with Birla Putty etc complete all as specified and directed by Engineer-in-Charge
M&L for Preparing unplastered or plastered surfaces of wall and applying two coats of oil bound distemper including primer by using smooth roller finish etc complete all as specified and directed by Engineer-in-Charge
S&F wall mixture with telephone shower arrangement, connecting legs & wll flanges butwithout crunch & telephone shower etc complete all as specified and directed by Engineer-in-Charge Make : CAT PART NO CQT-23267 OF JAQUAR , MSH1141 of Marc or equivalent in PLUMBER / ESS-ESS
S&F health faucet (ABS Body) with 1 meter long easy flex tube in chrome finish & wall hook etc complete all as specified and directed by Engineer-in-Charge. Make Jaquare Cat No ALD-CHR-585 or equivalent in Marc / Plumber / ESS-ESS
S&F two way bib cock with wall flange etc complete all as specified and directed by Engineer-in-Charge. make Jaquare CAT No LYR-38053 or its equivalent in Marc / Plumber / ESS-ESS
S&F corner glass shelf with bracket. etc complete all as specified and directed by Engineer-in-Charge Make Jaquare Cat No CAN-1173 in Marc / Plumber / ESS-ESS
S&F towel ring square CP fixed with brass screwes of etc complete all as specified and directed by Engineer-in-Chargemake Jaquare Cat No AKP-35721P of equivalent in Marc / Plumber / ESS-ESS
S&F toilet paper holder with flat etc complete all as specified and directed by Engineer-in-Charge. Make Jaquare Cat No AKP- 35753P or equivalent Marc / Plumber / ESS-ESS
M&L Colour European type WC with P trap of size 775 x 360 x 660 mm fixed to floor including floor trap, 10 litre capacity PVC flushing cistern, seat cover and all fittings etc complete all as specified and directed by Engineer-in-Charge. Make Jaquare Cat No CNS-WHT-WS11 or equivalent in Hindware / Parryware / Cera
M&L rough dressed shahabad stone 25 mm thick laid over 15 mm thick screed bed in cement and sand mortar (1:6) and pointed in neat cement slurry etc complete all as specified and directed by Engineer-in-Charge
All as per item No 113 (here-in-before) but fixing only
S&F powder coated anodized aluminum frame for door, windows or ventilators with or or more rebates including jointing cleats for fixing etc complete all as specified and directed by Engineer-in-Charge
S&F powder coated anodized aluminum shutters for door section weighting 0.55 kg /m including necessary joining cleats, glazing clips, rubber neoprene packing, handle 2 Nos in each door, hinges anodized snap bearing screws etc complete all as specified and directed by Engineer-in-Charge
S&F powder coated anodized aluminum shutters for windows or ventilators section weighting 0.55 kg /m including necessary joining cleats, glazing clips, rubber neoprene packing, peg stays 150 mm long (1 No) hinges type B-21 100 mm long (2 Nos) suitable handle ( 1 No) snap bearing screws etc complete all as specified and directed by Engineer-in-Charge
S&F 10 mm thick PVC insulation panels with EPS stuck to 1 mm plain PVC sheet suitably placed in false ceiling grid made of Aluminum / GI/ MS as per specification and drawing including dismantling of ceiling boards or insulation boards of any description and any thickness including cover fillets etc complete all as specified and directed by Engineer-in-Charge
M&L second class hard wood timber scantling with preparation of new supply and apply creosoting including dismantling un framed timber scantling 40 sq cm and over in section and in any position etc complete all as specified and directed by Engineer-in-Charge
Demolition of brick/ stone masonry built in cement or lime mortar etc complete all as specified and directed by Engineer-in-Charge
Supply only integral water proofing compound etc complete all as specified and directed by Engineer-in-Charge
M&L for preparation of old wooden surface and one coat of synthetic enamel paint etc complete all as specified and directed by Engineer-in-Charge
M&L for preparation of old steel surface and one coat of synthetic enamel paint etc complete all as specified and directed by Engineer-in-Charge
M&L for Machine cut kota stone slab flooring 20-25mm thick over 15 mm thick cement screed base in cement and sand mortar (1:6) laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing etc complete all as specified and directed by Engineer-in-Charge
M&L for Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over 10 mm backing coat in cement and sand mortar (1:4) and jointed with ditto as per item
Material and labour for 60 mm thick, PCC pavers interlocking tiles of glossy finish, with grey cement and no pigment ,any shape & size conforming to IS 15658 of 2006. M-35 grade made up with 12.5mm graded mechanically crushed stone aggregates, factory made over and incl 30mm thick sand cushioning and joints filled with fine sand incl leveling & sweeping etc complete all as specified and directed by Engineer-in-Charge
All as per item No 127 (here-in-before) but fixing only
S&F Sink cock with Regular swinging spout (Wall mounted model) with wall flange etc complete all as specified and directed by Engineer-in-Charge Make Jaguar Cat No ARI - 39347 or equivalent in Marc / Plumber / Ess-Ess
S&F for 75 mm PVC SWR vent cowl etc complete all as specified and directed by Engineer-in-Charge
Taking down carefully aluminium point wiring (light, fan, bell, socket, power point etc.) with or without conduit, casing caping, along with all connected accessories such as ceiling rose, switches, sockets, switch boards, fan regulator etc complete all as specified and directed by Engineer-in-Charge
M & L for point wiring complete with 1.5 Sqmm single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLS cable drawn through and including PVC casing & capping with necessary accessories with Flush steel mounting boxes of mylanic series of Legrand and white plates with frame of myleic series of Legrand of suitable size required at site. housing of switches sockets / fan regulator etc. including 1.5 Sqmm single core solid multitranded copper conductor FRLS 1100 volts grade PVC insulated and unsheathed cable as earth continuity conductor to common earth & connecting to earth dolly for the following :- (Note :- The cost of Mudular mounting boxes and modular plates included in the quatated rates)
(a) One light point controlled by one, one way switch single pole.
(b) One Fan point controlled by one, one way switch single pole.
(c) One 3 pin 5 Amps socket out let on independent board
(d) One 3 pin 5 Amps socket out let on Sameboard
All as per item No 136 here-in-before but with 2.5 Sqmm Copper conductor cable for Phase, Neutral and earth for one 3 pin, 15 Amps socket out let on independent board.
S & F 6 A one-way SP switch - 1 module of Make Legard Cat No: 6755 01 or equvalent in Simens / Carbtree all as specified and directed.
S & F 16 A one-way SP switch - 1 module of Make Legard Cat No: 6755 11 or equvalent in Simens / Carbtree all as specified and directed
S & F 6 A 3 pin universal socket 2 modules of Make Legard Cat No: 6755 50 or equvalent in Simens / Carbtree all as specified and directed.
S & F 6/16 A socket 3 Pin 2 modules module of Make Legard Cat No: 6755 55 or equvalent in Simens / Carbtree all as specified and directed.
S & F Fan regulator 100 W with 2 module of Make Legard Cat No: 6755 30 or equvalent in Simens /Carbtree all as specified and directed.
S&F ceiling rose surface bakelite three terminal all as specified and directed. Make : Anchor/Havells/Standard
S&F Lamp holder Lamp holder with LED Lamp 07 Watt of Make Havells/CG/Wipro all as specified and directed.Make : Anchor/Havells/Standard
S & F in replacement double door Sheet metal enclosures factory made DBs 8 way ,240 volts ,protection class IP-42, suitable for fixing of MCBs, Isolators etc, confirming As per IEC 61439-3 ,Suitable for Flush Mounting and Surface Mounting, With 100 A Copper Busbar ,With Neutral bar, Earthbar and Cable ties for Cable management,Fully shrouded Neutral bars, Prefitted masking sheet complete all as specified and as directed. Make: Legrand ,Cat No: 5076 11 or equivalent in Simens/ Hager/ L & T
S & F double door Sheet metal enclosures factory made DBs 4 way ,240 volts ,protection class IP-42, suitable for fixing of MCBs, Isolators etc, confirming As per IEC 61439-3 ,Suitable for Flush Mounting and Surface Mounting, With 100 A Copper Busbar ,With Neutral bar, Earthbar and Cable ties for Cable management,Fully shrouded Neutral bars, Prefitted masking sheet complete all as specified and as directed. Make: Legrand ,Cat No:5076 10 or equivalent in Simens/ Hager/ L & T
S & F Issolators of the under mentioned type and rating and fixing in DBs (DBs measured and paid for separately) (Note :- Make of the isolator should be the same as that of DB) for the following :-
(a) MCB Single Pole of 240 volts 5-32 Amps,10 KA Capacity, 'C' series of Make: Legrand ,Cat No: 4085-87 to 90,92,93,94,95 or equivalent in Simens/ Hager/ L &
(b) MCB Single pole + Neutral 240 volts, 32 -63 Amps,10 KA Capacity, 'C' series of Make: Legrand ,Cat No: 4086-17 to 20 or equivalent in Simens/ Hager/ L & T
M & L for Earthing complete with galvanized steel earth plate electrode 60x60cm x 6.0 mm thick buried directly in ground ( earth pit not less than 2.25 mtr deep below ground level) with top edge of plate not less than 1.5 mtr below normal ground level connected to and including galvanised earth lead wire 4.0 mm dia,by means of nuts,bolts,checknuts and washers of galvanized iron including 15 mm bore GI pipe,medium grade up to 7.5 meters long all as shown in electrical plate No.3 of MES SSR part-I and testing on completion including excavation and earth work in any type of soil, PCC (1:3:6) type C1 chamber,precast RCC slab 50mm thick in cement concrete (1:2:4) type B1 reinforced with welded steel wire fabric or XPM,( weight not less than 4 Kg/Sqm), with cast iron frame, funnel with wire mesh,GI watering pipi 20 mm dia medium grade,test point and lugs complete. NOTE:-(i) Items includes the cost of 7.5 metre length GI pipe and earth lead for protection of earth lead.Any variation in length shall be adjusted through deviation order.(ii) On testing,if the earth resistance is not obtained,earthing will be regenerated at no extra cost till the desired earth resistance is obtained.
Taking down Existing tube light fitting & Supply & fix Endura LED Batten fitting 20 watt with minimum 2000 lumen output with 6500 K including connecting up with thre core twisted flexible copper conductor cable with suitable size from ceiling rose to fitting all as directed by the Engr-in-Charge.Make :- Jaguar ,Cat No. LGLZ01X020XCPhilips ,or eq in Philips,Cat No. BN108C LED 20S PSU CDL WH /Havells ,Cat No. ENDURALINEARNEOBS20WLED830SPCWH
Supply & fix Endura LED Batten fitting 20 watt with minimum 2000 lumen output with 6500 K including connecting up with thre core twisted flexible copper conductor cable with suitable size from ceiling rose to fitting all as directed by the Engr-in-Charge.Make :- Jaguar ,Cat No. LGLZ01X020XCPhilips ,or eq in Philips,Cat No. BN108C LED 20S PSU CDL WH /Havells ,Cat No. ENDURALINEARNEOBS20WLED830SPCWH
S&F LED Bldg security light Luminaries 30 watt, Lumens output 3000 with pressure die-cast aluminium housing with heat resistance toughtened glass & IP 65 protection, fixed with suitable sice of GI Bracket,Clamp,Nut, Bolt and washer , connection with 1.5 sqmm 3 run copper wire from junction box all as specified and directed. Make : Wipro cat part No LR02-331-XXX-57-XX or equivalent Philips And GE Lighting.
M & L for Supply,laying ,connecting ,testing and commissioning and jointing , LT underground cable in replacement ,1100 volts grade, XLPE insulated, armored with galvanized round steel wire or steel strip, electric power cables heavy duty, with multi stranded aluminum conductor, laid in ducts, fixed on poles/walls with proper size saddles and clamp complete all as specified and as directed by the Engineer-in-Charge of Size 10 Sqmm 2 Core :- (Make :- Polycab/Havells/ CCI)
M & L for Supply,laying ,connecting ,testing and commissioning and jointing , LT underground cable in replacement ,1100 volts grade, XLPE insulated, armored with galvanized round steel wire or steel strip, electric power cables heavy duty, with multi stranded aluminum conductor, laid in ducts, fixed on poles/walls with proper size saddles and clamp complete all as specified and as directed by the Engineer-in-Charge of Size 6 Sqmm 2 Core :- (Make :- Polycab/Havells/ CCI)
Supply and Lay HDPE pipe 32 mm bore for laying of LT cables etc complete with all accessores all as specified and directed. Make: Vectus Industries/ Supreme / Infra / Astron Plastic
M & L for point wiring complete with 1.5 Sqmm single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLS cable drawn through and including PVC casing & capping ISI Marked with necessary accessories with and provision of pressed steel terminal box powder coated of suitable size with 3 mm thick plastic laminated sheet by using CP machine screw for housing of switch / fan regulator etc. including 1.5 Sqmm single core solid multitranded copper conductor FRLS 1100 volts grade PVC insulated and unsheathed cable as earth continuity conductor to common earth & connecting to earth dolly for the following :-
(a) One light point controlled by one, one way switch single pole.
(e) One 3 pin 5 Amps socket out let on Sameboard
S&F switch piano flush type 230/250 Volt, 5 Amps single pole one way, all as specified and directed and directed .Make: Anchor/Havells/Standard.
S&F switch socket combination multi purpose 2 in 1, 6 pin 5 Amps, flush type, ISI marked all as specified and directed and directed .Make: Anchor/Havells/Standard
Supply and laying of un-reinforced prcast concrete cable cover, class LV, Type 1 with peak, size 250mm x150mm x40mm complete all as specified and directed
Supply and lay in trenches / or wall light grade steel watr tubing galvanised with all fittings and joints etc complete for cable protection following size 25mm bore.
Ball brass valves, high pressure, with polythene flat and flynut complete, screwed for iron pipe orbrass ferrule and fixed
Supply and fix gun metal gate valve with iron wheel head screwed both ends for iron pipe and fixed for 25 mm bore
Cutting to existing GI pipe line upto 50 mm dia for taking connection upto 40 mm dia GI pipe with and including insertion of tee complete all as specified and as directed including exavation and earthwork
Supply and lay in trenches / or wall light grade steel watr tubing galvanised with all fittings and joints etc complete for cable protection following size 25mm bore.
An amount of Rs 12,790.00 shall be deducted from BOQ on account of schedule of credit
Ms. M.D. Auty
OM SAI ASSOCIATES
M/s.Abhay Kulkarni and Associates
DAKSH ENGINEERS AND BUILDERS
M/s. Sagar Traders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .