| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | H3₹48.4 L−₹3.6 L (6.95%)Accepted-AOC | H3 | Accepted-AOC Contract awarded to M/s SAI Engineering | |
| 2 | H1₹52.1 LRejected-Finance | H1 | Rejected-Finance Higher rate quoted than H3 | |
| 3 | H2₹49.8 L−₹2.2 L (4.32%)Rejected-Finance | H2 | Rejected-Finance Higher rate quoted than H3 |
| Sl No | Description | Qty | Unit | M/S. MAJUMDER CONSTRUCTION H2 | S S ENTERPRISE H1 | SAI ENGINEERING H3 |
|---|---|---|---|---|---|---|
| 1.00 | Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for and removal of rubbish off the site complete all as specified and directed. | 5.72 | Cum | 450 ₹2,574 Lowest | 460 ₹2,631.2 | 500 ₹2,860 |
| 2.00 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing and depositing serviceable tiles where directed, and rubbish off the premises complete all as specified and directed. | 80 | Sqm | 30 ₹2,400 | 35 ₹2,800 | 22 ₹1,760 Lowest |
| 3.00 | Dismantling Wall and Ceiling Boards (Fibre, Pulp, Insulation, etc.) or Insulation Boards/Blankets/ Slabs, any description and any thickness including Cover Fillets, Cornices, etc., complete all as specified and as directed. | 105 | Sqm | 25 ₹2,625 | 30 ₹3,150 | 10 ₹1,050 Lowest |
| 4.00 | Excavating in trenches , n.exc 1.5 m wide and n.exc 1.5 m depth for foundation etc or for shafts, wells, cesspits ,manhole pier hole, laying of cables, pipes etc n.exc 10 sqm on plan and n.exc 1.5m in depth and getting out in any kind of soil
Note : Manual excavation to be done. During excavation if any damage occured to existing cable any type/ water pipe line, it will be contractor responsibilty to get it repair and make functional by providing jointing kit etc without any extra cost. Contractor has to repair it within 24 hrs so that essential service can not be effected due to such damage.If contractor fails to repair it within 24 hrs penalty @ Rs 500/- will be charged to contractor. In this GE decision will be final, conclusive and binding. | 679 | Cum | 400 ₹2,71,600 Lowest | 450 ₹3,05,550 | 420 ₹2,85,180 |
| 5.00 | Excavating over areas, n exc 1.5 m deep and getting out soft/loose soil complete all as specified. | 5.81 | Cum | 420 ₹2,440.2 Lowest | 450 ₹2,614.5 | 460 ₹2,672.6 |
| 6.00 | Returning, Filling in, including Spreading, Levelling, Watering and Well Ramming in Layers not exc. 250mm in Soft/Loose Soil, complete all as specified and as directed. | 386 | CUM | 100 ₹38,600 | 120 ₹46,320 | 80 ₹30,880 Lowest |
| 7.00 | Removing excavated Materials (Soils) not exc. 50.00 mtr and depositing where directed at a level not exc. 1.50 mtr above the Starting Point in Soil, complete all as specified and as directed. | 300 | CUM | 120 ₹36,000 | 135 ₹40,500 | 110 ₹33,000 Lowest |
| 8.00 | M&L for Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified. | 5.81 | Cum | 600 ₹3,486 Lowest | 625 ₹3,631.25 | 700 ₹4,067 |
| 9.00 | M&L for Hardcore using broken stone or boulders of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified. | 8.71 | Cum | 3,200 ₹27,872 Lowest | 3,500 ₹30,485 | 3,200 ₹27,872 Lowest |
| 10.00 | M & L for Sand filling under floors or in foundation including watering and consolidation complete all as specified and directed. | 0.23 | Cum | 1,200 ₹276 | 1,150 ₹264.5 Lowest | 1,400 ₹322 |
Tender Value
₹47.7 L
EMD Value
₹95,500
Closing Date
10 Dec 2025, 6:00 pmClosed
GE PANAGARH
GARRISON ENGINEER PANAGARH, MILITARY ENGINEER SERVICES, PO-PANAGARH, DISTT- BURDWAN, STATE-WEST BENGAL PIN-713420
All as per tender document
2025_MES_740625_1
8500-470/E8
Open Tender
Civil Works
Works
180 days
PANNGARH
All as per BOQ
6 documents required · 6 mandatory
₹500
GE Panagarh
₹95,500
30 Jan 2026
20 Nov 2025
11 Dec 2025
20 Nov 2025
10 Dec 2025
4 Dec 2025
Amount
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for and removal of rubbish off the site complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing and depositing serviceable tiles where directed, and rubbish off the premises complete all as specified and directed.
Dismantling Wall and Ceiling Boards (Fibre, Pulp, Insulation, etc.) or Insulation Boards/Blankets/ Slabs, any description and any thickness including Cover Fillets, Cornices, etc., complete all as specified and as directed.
Excavating in trenches , n.exc 1.5 m wide and n.exc 1.5 m depth for foundation etc or for shafts, wells, cesspits ,manhole pier hole, laying of cables, pipes etc n.exc 10 sqm on plan and n.exc 1.5m in depth and getting out in any kind of soil Note : Manual excavation to be done. During excavation if any damage occured to existing cable any type/ water pipe line, it will be contractor responsibilty to get it repair and make functional by providing jointing kit etc without any extra cost. Contractor has to repair it within 24 hrs so that essential service can not be effected due to such damage.If contractor fails to repair it within 24 hrs penalty @ Rs 500/- will be charged to contractor. In this GE decision will be final, conclusive and binding.
Excavating over areas, n exc 1.5 m deep and getting out soft/loose soil complete all as specified.
Returning, Filling in, including Spreading, Levelling, Watering and Well Ramming in Layers not exc. 250mm in Soft/Loose Soil, complete all as specified and as directed.
Removing excavated Materials (Soils) not exc. 50.00 mtr and depositing where directed at a level not exc. 1.50 mtr above the Starting Point in Soil, complete all as specified and as directed.
M&L for Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified.
M&L for Hardcore using broken stone or boulders of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified.
M & L for Sand filling under floors or in foundation including watering and consolidation complete all as specified and directed.
M&L for PCC 1:4:8 type D-2 (using 40mm graded stone aggregates) as in bed concrete for foundation filling & mass concrete complete all as specified.
M & L for Cement concrete (1:3:6) Type C2 using 40 mm graded aggregates as in foundations, filling and mass-concrete.
M & L for reinforced cement concrete (Design Mix) M-25 (20mm graded crushed stone aggregate) foundations, including rafts, footings, foundation beams, plinth beams; bases for columns, etc. and mass concrete etc complete all as directed.
M & L for reinforced cement concrete (Design Mix) M-25 (20mm graded crushed stone aggregate) in columns, pillars, piers, etc complete all as specified.
M & L for reinforced cement concrete (Design Mix) M-25 (20mm graded crushed stone aggregate) in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified.
M & L for reinforced cement concrete (Design Mix) M-25 (20mm graded crushed stone aggregate) in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified.
M & L for brickwork with fly ash old sized bricks, straight or curved on plan exc 6 m mean radius, built in CM 1:6 complete all as specified.
M&L for Steel Centering and shuttering including strutting, propping etc. and removal of form to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and directed.
M&L for Steel Centering and shuttering including strutting, propping etc. and removal of form to sides of pillars, posts, struts, piers, columns and stanchions for fair finished surface of concrete Complete all as specified and directed.
M&L for Steel Centering and shuttering including strutting, propping etc. and removal of form to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc. for fair finished surface of concrete, complete all as specified and directed.
M&L for Steel Centering and shuttering including strutting, propping etc. and removal of form to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping), for fair finished surface of concrete, all as specified and as directed.
M & L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified.
S&F TMT reinforcement bar, conforming to Fe-500, 5mm dia and upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends as binding with and including mild steel wire (Annealed) not less than 0.9mm dia or securing with clips all as specified.
S & F Roof trusses (framed) of angle iron members trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee,angle,channel or flat sections) including distance pieces, cleats etc complete all as specified.
S & F Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment using Fe 410 -W (Gde E- 250) quality A. complete all as specified and directed.
S&F mild steel screw bolts (machine made)with hexagonal or square heads at one end and screw other .and each screw end to be fixed with washers and nut exc 5 cm but n.exc 10 cm long complete all as specified and directed.
Material & Labour for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels , plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement, complete all as specified and directed.
M & L for pre-painted hot-dip aluminium-zinc alloy metallic coated of any profile steel sheet corresponding to IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.50 mm thick, of an approved colour and having yield strength of 550 MPa as in roof covering fixed with self tapping screws as specified up to anyheight including all necessary scaffolding and safety measures complete all as specified and directed
M & L for pre-painted hot-dip aluminium-zinc alloy metallic coated plain steel sheet as per IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.50 mm thick, of an approved colour and having yield strength of 550 MPa as in ridge/ valley/ gutter fixed with self tapping screws as specified any height Mtr height including all necessary scaffolding and safety measures complete all as specified and directed
S & F 2 mm thick fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with coach/self tapping screw and washer in roof, wall etc, complete all as specified.
S & F 3 mm plain fibre glass sheet fixed to framed iron work or in claddings/similar works.
Supply and fix Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long, size of grid 605 x 605mm complete all as specified and directed.
S & F anodised aluminium snap grid frame work for false ceiling ( size of grid 605x605 mm ) all as specified.
S & F Non asbestos fibre cement designer building boards 6 mm thick fixed or laid/ inserted to timber/GI/Aluminium framework with screws in ceiling complete all as specified.
S & F solid PVC prelaminated wall Lining consisting of 5mm thick Plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing complete all as specified and directed.
S & F 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC frame as per specification and drawing.
M & L for rendering 15 mm thick in CM (1:4) on fair faces of brick work or concrete surfaces of wall, surface finished even and smooth without using extra cement complete all as specified and directed.
M & L for 100 mm thick Cement concrete type C- 2, 1:3:6 (using 40mm graded crushed aggregate) as in sub base, sub floors etc complete all as specified and as directed..
M & L for light shade vitrified ceramic tiles 10mm thick (square/ rectangular ) polished , area of each tiles not exceeding 0.36 Sqm, in floors etc set and jointed in neat cement slurry and pointed flush in white or colour cement with pigment over and including 15mm thick cement mortar 1:6 screed bed complete all as specified.
M&L for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete lad over cement screed and jointed over screed bed or bedding layer of mortar 20mm thick in CM 1:6 for laying floor finish complete all as spd and directed.
M&L 18-20 mm for Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over and incl 20mm thick CM (1:6) screed bed, complete all as specified and as directed.
M&L for 75 mm thick cement concrete M10 (Nominal Mix) with 40mm graded crushed aggregate finished even and fair laid to a slope of 1 in 12, laid in alternate bays, each bay not exceeding 3 m length with joint filled with bituminous mastic filling comprising a mixture of 1 part of heated Industrial bitumen 85/25 grade and two parts of heated sand as in plinth protection complete all as specified
M & L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M- 35 Grade with grey cement and pigments complete all as specified and directed.
M & L for preparing new surfaces of walls plastered and white washing with 03 coats of white wash on walls complete all as specified and directed.
M&L for preparing of new steel & iron surfaces of any description, not otherwise described, over 10cm width or girth and applying two coats of synthetic enameled paint over a coat of Red oxide zinc chrome primer zinc chrome complete all as specified and as directed.
S & F in repair vitreous china one piece floor mounted toilet seat one piece construction and urinal shall have integral longitudinal flushing pipe of suitable type with UF seat cover, hinges, fixing accessories set , cistern fittings pattern white of size Size 650 x 665 x 760 including trap complete all as specified.
M & L for fixing PVC (SWR) pipes of 100 mm bore diameter single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed.
M&L for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc.as specified & directed by Engr-in-Charge
Material & Labour for point wiring complete with 1.5 sq mm FRLSH, PVC insulated multi stranded copper conductor single core cable 1100 volts grade (Red Colour use for Phase & Black Colour use for Neutral),drawn into and including PVC casing- caping (double interlock type) of not less than 20mm width with accessories and fittings such as bends, elbows, tees, crosses, junction box etc, fixed on wall/ceiling with GI saddles, GI screws, rawl plugs etc. for one light/fan/ bell point controlled by one switch including pressed steel terminal box powder coated of suitable size with 3 mm thick plastic laminated sheet cover of approved make for housing/mounting switches, sockets & regulators etc. and drawing 1.5 sq. mm copper solid conductor PVC insulated, unsheated cable as earth continuity conductor, connected to common earth and earth dolly , all as specified and directed by Engineer-in-Charge Note :- Cost of PVC casing & capping, making good disturbed wall surfaces including finishing with cement mortor 1:4, matching with existing colour/paint of surface are deemed to be included in the quoted rate. (ii) Length of point wiring up to 7.50 meter and to be measured from switches to ceiling rose or to the actual load.
Supply and fixed switch piano flush type, single pole , 5/6 Amps, one way complete all as specified. (Note : Item to be measured if executed under new point wiring)
Supply & fixed ceiling rose surface bakelite 65 mm x 50 mm two to three terminal suitable for 230 Volts AC 6 Amps complete all as specified. (Note : Item to be measured if executed under new point wiring)
S & F in repair LED street/security lights nominal power 35/36 Watt, LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen efficacy of minimum 110 lumens per watt, built-in integrated electronic LED driver, output open /short circuit protection, phase to phase protection, over voltage protection, surge voltage protection upto 4 KVs, protection grade IP 66, CRI greater than 80%, CW available CCT of 5700K, power factor of minimum 0.95, pressure die-cast aluminium alloy housing with epoxy powder coated metallic silver finish after phosphochromate treatment, life span of minimum 50000 working hours including fixing at any height and including wiring using three core PVC insulated, PVC sheathed, flexible stranded copper conductor FR-LSH cables suitable for outdoor use, 1.5 sqmm as per IS 694: 2010 complete all as specified and as directed.
S & F in repairs sheet metal enclosure for MCB, DB, SPN, 240 Volts, 100 Amps rated busbar, Confirming to IS as per IEC 61439-3, 4 way single door enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 30 , IK 08 including fixing the DB box flush in wall of any type and making good the distrubed surface to match as the existing with all as specified and directed by Engr-in-charge.
Supply and fixed MCB SP 6-32 Amps, 'C' curve 10kA, 240 Volts and to be housed in DBs complete including necessry connection all as specified and directed engr-in-charge.
Supply and fixed MCB SPN 32 Amps, 'C' curve 10kA, 240 Volts and to be housed in DBs complete including necessry connection all as specified and directed engr-in-charge.
S&F in repairs LED 20 Watt tube light fitting intregated type, including LED retrofit tube lamp 20 W , LED tube light nominal power 20 Watt, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, , lumen efficacy of minimum 110 lumens per watt, , integrated electronic driver (SMP based constant current supply) with output short circuit protection and surge protection upto 2.5 KV, protection grade IP 20, CRI greater than 80%, bema angle of 120 clear, THD below or less than 20%, CW available CCT of 6500K, power factor of minimum 0.95 life span of minimum 50000 working hours and LED batten with aluminium housing and polycarbonate diffuser complete fitting including connecting with PVC insulated multistranded copper flexible cable 1.0 sqmm three core, and PVC round/ square box white colour x 2 Nos for mounting of fitting complete all as specified & directed. Note (i) Make of batten and LED tube lamp should be of same make.
Supply, Laying and testing cable LT XLPE sheathed,PVC insulated screened PVC bedded,galvanised steel strip of wire armoured electric power cable heavy duty with solid aluminium conductor 1100 volt grade, laid in trenches/surface of wall/in GI pipe along with pole for connection to OH lines,including brass cable glands,clamps,etc of 2 core 6 sqmm. complete all as specified and directed.
Taking down of light fittings of any type size and model complete all as specified and directed.
Taking down of brackets of any type size and model complete all as specified and directed.
Dismantling steel poles/struts of any size and removing off the site as directed.
Taking down/out unserviceable UG Cables of any Cross Sectional Area and Connections including Bricks, GI Pipes, etc. of any descriptions, laid in Trenches and/or fixing with Walls/Poles including Segregating of Serviceable Materials viz Bricks, Cables, GI Pipes, etc. and keep in Safe custody for re-use, complete all as specified and as directed
Material and labour for steel tubular poles complete with cast iron base palate, final taper plug bolts, nuts & screws as specified type 410 SP-22 8.50 meter long including painting all external exposed steel surfaces with two coats of aliminium paint over a coat of red oxide zinc chrome primer including marking pole numbers in a 15 cm dia yellow circle with number writting with black syenthic paint/ Stricker, including painting strips in alternate from top of coping upto 1.50m height, with three strips of black syenthatic paint & two strips of Yellow/ Sky blue paint (as per existing pattern through out the circumference of pole), including and all internal surfaces and external surfaces upto the planting depth shall be painted with two coats of black bitumenous paint complete all as specified and as directed (Note:- Earth work, PCC work, shall be measured and paid separately.)
S&F Cable Junction Box 155X210X92 mm in size, made out of thermoplastic, having IP 66 protection for outdoor installation fixed with 4 way bakelite cable terminals including 03 Nos polymide gland with check nut (M-32 -02 No & M-25 -01 No) fixed on poles with Aluminium clamps of size 25x3mm, nuts, bolts, washers etc. including taking out of old unserviceable cable junction box complete all as specified and as directed.
Supply and passing through steel tubler pole/service connection, 1100 volts grade multicore,FR, round insulated copper conductor and sheathed flexible cable,multistranded, three core of nominal cross sectonal area 1.5 Sq mm,for connection of security light from junction box through pole /conduit with all terminals complete all as specified and as directed.
S&F single arm bracket made of 40mm dia 1.0mtr long for security light ,with mounting MS clamp of flat iron size 25X5 mm of suitable length 02 pairs including nut bolts etc of suitable size and painting to MS clamp with two coats of aluminium paints over a coat of red oxide metal primer all as specified and directed by Engr In charge.
Material and labour for earthing complete with Galvanised steel earth plate electrode 600x600x6 mm mm buried directly in ground (Earth pit not less than 2.25m below ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to GI wire 4 mm as earth lead by means of bolt, nuts, check nuts and washers of galvanised iron or steel, upto 7.5m length, earth strip protected by and including 15 mm dia GI pipe (light grade) and connected to main test point or body of pole/pannel or lightening arrester of main controlling switch as directed including concrete pit in PCC (1:3:6) type C1 , Precast RCC (1:2:4) Type B1 cover slab of size 54x54x5 cm reinforced with 8 mm dia TMT bars @ 100 mm C/C both ways with one handle for lifting made out of 10 mm dia TMT bar embedded in precast cover slab, funnel, wire mesh, 20 mm bore GI Pipe (Medium Grade) for watering, Charcoal and salt in alternate layers of 15 cm (Compacted Thickness) around the earth electrode including necessary excavation, earth work in any type of soil and disposal of spoil to a distance n.exc 50 m and necessary testing complete all as shown in Electrical Plate No 3 of SSR Part-I. NOTE : 1. The unit rare includes for protectionh GI pipe of 15mm and watering pipe of 20mm bore including excavation for earth pit in any type of soil/disintegrate rock. 2. Contractor has to bring agriculture soil from outside of defence land and fill in earth pit to acheive desired result as the soil resisitivity is very high. 3. The cost of GI wire including protection pipe, from top of earth plate upto 7.5 meter above/below ground level is deemed to be included in the unit rate. 4. All the joints in GI wire and connectgion with earth plate to be welded through brazing and in addition by providing double brass nut bolt and washer. 5.Costing of welding and nut bolts are deemed to be included in the unit rate
M&L for earthing complete with galvanised steel earth plate electrode size 600 x 600 x 6 mm thick, burried directly in ground, (Earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below ground level connected to galvanised iron strip 32 x 6 mm as earthin lead wire by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 connected to earthing test point all as specified or indicated including testing on completion, surrounded from all sides by mixture of charcoal and common salt and electrode by means of steel and GI pipe Md grade 20mm dia bore for watering funnel with wire mesh. CI cover with frame, PCC chamber pit with PCC 1:3:6 type C-2 excavation and earth work all as shown in electrical plate No 3 connected to earthing test point all as specified NOTES 1. The unit rate includes for protection pipe and GI strip dia from top of earth plate upto 7.5 meter above ground level. NOTE:- 1. The unit rate includes for protection GI pipe of 40 mm and watering pipe of 20 mm bore including excavation for earth pit in any type of soil/ disintegrate rock. 2. Contractor has to bring agriculture soil from outside of defence land and fill in earth pit to achieve desired result as the soil resistiviy is very high. 3.The cost of GI strip of size 32 x 6 mm from top of earth plate upto 7.5 meter above ground level is deemed to be included in the unit rate of above item.and copper strip beyond 7.5 RM will be measured seperately. 4. All the joints in GI strip and connection with Earth Plate to be welded through brazing and in addition by providing double brass nut bolt and washer. 5. Cost of welding and nut bolts are deemed to be included in the unit rate.
M&L Sand Cushioning (dry) in trenches for protection of UG Cables (below, above and around the UG Cable laid in Trenches) of 230mm Spread thickness and consolidated (punned) upto 180mm thickness, complete all as specified and as directed. (NOTE : For the purpose of Payment, Punned thick-ness of Sand Cushioning only shall be Measured and Paid )
Supply and laying well burnt Bricks , locally available best quality (sub class "B" bricks) laid in trenches perpandicular to U/G cable for cable protection complete all as specified.
Laying only in trenches or passing through pipe, XLPE insulated, heavy duty, galvanised steel strip or wire armoured electric LT cable with stranded aluminium conductor for 1100 volts grade cross sectional area 50 sqmm 3.5 core. Note : Cable will be issued under Sch B free for laying only
Laying only in trenches or passing through pipe, XLPE insulated, heavy duty, galvanised steel strip or wire armoured electric LT cable with stranded aluminium conductor for 1100 volts grade cross sectional area 10 sqmm 4 core. Note : Cable will be issued under Sch B free for laying only
S & F 40 mm High density polyethylene pipe (HDPE) of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors etc. complete all as specified and directed .
S&F Galvanised Iron Pipe 40mm Bore (dia) ‘Light Grade’ for protection of UG Cable, laid in Floors/ Road Crossing, fixing to Pole with Mild Steel Clamps, Nuts, Bolts, etc., complete all as specified and as directed.
Labour only for Horizontal Boring for Passing Protection Pipe up to 80mm Bore (dia), under Road /Foot Path, not exc. 10.00 mtr in a Single Length, complete all as specified and as directed. Note : Pipe to be measured separately.
M&L for PCC (1:2:4) type B1 (using 20 mm graded crushed stone aggregate) as in coping for pole including form work and finishing the surfaces even and smooth,dismantling etc complete all as specified and as directed.
Fixing only LED street light fitting 100 Watt 230 V AC outdoor type including necessary connection complete all as specified. Note : Street light will be issued under Sch B free for fixing only.
Fixing only LED Flood light fitting 200 Watt 230 V AC outdoor type complete all as specified and directed. Note : Flood light will be issued under Sch B free for fixing only.
M/S. MAJUMDER CONSTRUCTION (BID ID -3504994)
SAI ENGINEERING (BID ID -3504958)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.42 MB
PS470.pdf
Tender Documents • 1.11 MB
BOQ_829329.xls
BOQ • 0.57 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .