Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.9 LAccepted-AOC HYDERPORA NEAR ELLAQUAI DEHATI BANK SRINAGAR KASHMIR J K 190014 | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190014 | L1 | Accepted-AOC LOWEST L1 | |
| 2 | L2₹43.9 L+₹1.0 L (2.35%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹46.9 L+₹4.0 L (9.34%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹48.1 L+₹5.2 L (12.1%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST | |
| 5 | L5₹48.4 L+₹5.5 L (12.8%)Rejected-Finance R O KHREW TEH PAMPORE DISTT PULWAMA PIN 191103 J K | PULWAMA | JAMMU AND KASHMIR | 191103 | L5 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹46.5 L
EMD Value
₹93,000
Closing Date
10 Aug 2022, 6:00 pmClosed
GARRISON ENGINEER
GE 970 EWS C/O 56 APO PIN 913970
PROVN OF COVERED PARKING SHED AND 03 X GEN SET AT JAK LI RC UNDER GE 970 EWS
2022_MES_520534_4
GE 970 EWS-13/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE 970 EWS C/O 56 APO
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE 970 EWS
₹93,000
Yes
9 Mar 2023
22 Jul 2022
12 Aug 2022
22 Jul 2022
10 Aug 2022
27 Jul 2022
Amount
Excavation in trenches n.exc 1.50m wide and n exc 1.5m depth for foundation and getting out in soft/loose soil complete all as specified and directed
Returning filling in incl spreading leveling watering and well rammings in layers n exc 25cm thick complete all as specified and directed.
Removal of surplus soil n exc 50m and depositing where dirtected at a level n exc 1.5m above the starting point complete all as specified and directed.
Plain cement concrete 1:4:8, type D-2 using 40 mm graded stone aggregate as in foundation, filling and mass concrete complete all as specified & directed.
Plain cement concrete 1:2:4, type B-2 using 40mm graded crushed stone aggregate as in foundation (for post) filling and mass concrete complete all as specified and directed.
Brick work with sub class ‘B’ bricks of class designation 10 all as per IS-1077-1992 using old size bricks, straight or curved on plan exc 6 metre mean radius built in cement mortar 1:6 complete all as specified & directed.
Rendering 15mm thick cement plaster 1:4 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified & directed
Preparation of new surfaces of walls & applying two coats of cement base paint over a coat of primer complete all as specified & directed.
75mm thick, plain cement concrete 1:4:8, type D-2 using 40mm graded crushed stone aggregate as in sub-base, sub-floors, floors and pavings etc complete all as specified & directed.
40mm thick, plain cement concrete 1:2:4, type B-1 using 20mm graded crushed stone aggregate as in sub-base, sub-floors, floors and pavings etc complete all as specified & directed.
M&L johnson endura paving coloured tiles of technocommercial equivalent of size 300mmx300mmx10mm set and jointed in neat cement slurry pointed with white or coloured cement laid over and incl 15mm thick screed bed built in CM (1:4) complete all as specified & directed
Plain cement concrete 1:2:4 type B-1 using 20mm graded aggregate as in coping or mud stops rounded or chamfered on edges, complete all as specified & directed.
M&L for steel work in tubular trusses/tubular vertical pipes including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete all as specified and directed.
Rolled mild steel work as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. conforming to grade Fe-410-W Gde-E-250 quality B complete all as specified and directed.
Plates (plain or chequered) channels. square cut or notched (ordinary and counter sunk) forming holes, without any attachment conforming to grade Fe-410-W Gde-E-250 quality B complete all as specified and directed.
Mild steel screw bolts (machine made) dia of neck exc 16mm but n exc 20mm with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 22.5cm and n exc 30cm long complete all as specified and directed.
Preparation of new steel surfaces and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering fixed with self tapping screws complete all as specified and directed.
Pre-painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridge, hips , valley gutters, drip and straight flashing(length and girth as fixed), fixed with self tapping screws complete all as specified & directed
Supply, installation, testing and commissioning of silent type diesel engine driven generating set with governing class G2 including sound reducing canopy (sound level not more than 75 decibal from 1 mtr distance) 14 gauge as per guideline issued by central pollution control board, 415 volts, 3 phase, 50 Hz supply suitable for giving an output of 62.5 KVA after considering derating factor confirming to IS-1601 at 5430 feet (approx) altitude above mean sea level and capable of operating between temperature range (-) 20 degree centigrade to (+) 40 degree centigrade (at Srinagar, J&K) and alternator of suitable capacity and RPM coupled with each other with flexible coupling mounted on common base plate on anti vibration pads on foundation as recommended by manufacturer. (a) Alternator: Directly coupled with engine and suitable to produce 415 volts, 3 phase 4 wire system, 50 Hz, 0.8 power factor @ 1500 RPM of capacity 62.5 KVA all as per IS-13364 and upto date amendments with H class insulation self excited, self regulated, screen protected drip proof type with two end shield ball/roller bearing with damper winding in each pole all as specified and directed. (b) Engine : Water cooled diesel engine (CPCB norms compliance) developing min 84 BHP or as recommended by the manufacturer for 5430 feet altitude having self start engine (including batteries with provision of charging the batteries and leads) suitable to drive above specified alternator complete with foundation (foundation design as per OEM), as per IS-10001/10002, coupled directly through flexible coupling, multi cylinder four stroke, cold starting, 1500 RPM industrial type with AI electronic governor suitable to regulate speed of DG set from No load to full load complete with fuel tank of capacity as per manufacturer recommendations, fuel lines, exhaust pipe duly insulated with asbestos rope and with support and silencer mufflers etc for continuous operation and standard accessories, sump pre heaters, cold start kit etc all as specified and directed. (c) Canopy : Canopy enclosure shall be powder coated and fabricated out of power coated after passing through seven tank process 16 SWG CRCA MS sheet and lockable doors should be provided in canopy with lockable fuel filling arrangement provided external to the canopy. The exhaust system and noise suppressor shall be provided with thermal insulation by using fire retardant/non igniting foam to prevent excess heat radiation on the engine and safe for operator. Absorption type non resistance residential silencer shall be provided to suppress exhaust noise from the engine. (d) Alignment and fuel tank : Alternator and engine aligned on a common 14 SWG CRCA MS base frame complete with MS fuel tank, fabricated out of 16 SWG CRCA MS sheet and is part of base frame. (e) Maintenance spares :- (i) Fuel filter element - 02 Nos (ii) Oil fileter element - 03 Nos (iii) Element air cleaner outer - 06 Nos (iv) Element air cleaner inner - 06 Nos (v) 'V' belt - 02 Nos (vi) Filter lubricant oil bypass - 02 Nos (f) DG set shall be supplied along with acoustic enclosure of the manufacturer suitable for 62.5 KVA DG set as per CPCB norms.
Supply, installation, testing and commissioning of silent type diesel engine driven generating set with governing class G2 including sound reducing canopy (sound level not more than 75 decibel from 1 mtr distance) 14 gauge as per guideline issued by central pollution control board, 415 volts, 3 phase, 50 Hz supply suitable for giving an output of 40 KVA after considering derating factor confirming to IS-1601 at 5430 feet (approx) altitude above mean sea level and capable of operating between temperature range (-) 20 degree centigrade to (+) 40 degree centigrade (at Srinagar, J&K) and alternator of suitable capacity and RPM coupled with each other with flexible coupling mounted on common base plate on anti vibration pads on foundation as recommended by manufacturer. (a) Alternator : Directly coupled with engine and suitable to produce 415 volts, 3 phase 4 wire system, 50 Hz, 0.8 power factor @ 1500 RPM of capacity 40 KVA all as per IS-13364 and upto date amendments with H class insulation self excited, self regulated, screen protected drip proof type with two end shield ball/roller bearing with damper winding in each pole all as specified and directed. (b) Engine : Water cooled diesel engine (CPCB norms compliance) developing min 54 BHP or as recommended by the manufacturer for 5430 feet altitude having self start engine (including batteries with provision of charging the batteries and leads) suitable to drive above specified alternator complete with foundation (foundation design as per OEM), as per IS-10001/10002, coupled directly through flexible coupling, multi cylinder four stroke, cold starting, 1500 RPM industrial type with AI electronic governor suitable to regulate speed of DG set from No load to full load complete with fuel tank of capacity as per manufacturer recommendations, fuel lines, exhaust pipe duly insulated with asbestos rope and with support and silencer mufflers etc for continuous operation and standard accessories, sump pre heaters, cold start kit etc all as specified and directed. (c) Canopy : Canopy enclosure shall be powder coated and fabricated out of power coated after passing through seven tank process 16 SWG CRCA MS sheet and lockable doors should be provided in canopy with lockable fuel filling arrangement provided external to the canopy. The exhaust system and noise suppressor shall be provided with thermal insulation by using fire retardant/non igniting foam to prevent excess heat radiation on the engine and safe for operator. Absorption type non resistance residential silencer shall be provided to suppress exhaust noise from the engine. (d) Alignment and fuel tank : Alternator and engine aligned on a common 14 SWG CRCA MS base frame complete with MS fuel tank, fabricated out of 16 SWG CRCA MS sheet and is part of base frame (e) Maintenance spares :- (i) Fuel filter element - 02 Nos (ii) Oil filter element - 03 Nos (iii) Element air cleaner outer - 06 Nos (iv) Element air cleaner inner - 06 Nos (v) 'V' belt - 02 Nos (vi) Filter lubricant oil bypass - 02 Nos (f) DG set shall be supplied along with acoustic enclosure of the manufacturer suitable for 40 KVA DG set as per CPCB norms.
Supply, installation, testing and commissioning of silent type diesel engine driven generating set with governing class G2 including sound reducing canopy (sound level not more than 75 decibal from 1 mtr distance) 14 gauge as per guideline issued by central pollution control board, 415 volts, 3 phase, 50 Hz supply suitable for giving an output of 30 KVA after considering derating factor confirming to IS-1601 at 5430 feet (approx) altitude above mean sea level and capable of operating between temperature range (-) 20 degree centigrade to (+) 40 degree centigrade (at Srinagar, J&K) and alternator of suitable capacity and RPM coupled with each other with flexible coupling mounted on common base plate on anti vibration pads on foundation as recommended by manufacturer. (a) Alternator : Directly coupled with engine and suitable to produce 415 volts, 3 phase 4 wire system, 50 Hz 0.8 power factor @ 1500 RPM of capacity 30 KVA all as per IS-13364 and upto date amendments with H class insulation self excited, self regulated, screen protected drip proof type with two end shield ball/roller bearing with damper winding in each pole all as specified and directed. (b) Engine : Water cooled diesel engine (CPCB norms compliance) developing min 40 BHP or as recommended by the manufacturer for 5430 feet altitude having self start engine (including batteries with provision of charging the batteries and leads) suitable to drive above specified alternator complete with foundation (foundation design as per OEM), as per IS-10001/10002, coupled directly through flexible coupling, multi cylinder four stroke, cold starting, 1500 RPM industrial type with AI electronic governor suitable to regulate speed of DG set from No load to full load complete with fuel tank of capacity as per manufacturer recommendations, fuel lines, exhaust pipe duly insulated with asbestos rope and with support and silencer mufflers etc for continuous operation and standard accessories, sump pre heaters, cold start kit etc all as specified and directed. (c) Canopy: Canopy enclosure shall be powder coated and fabricated out of power coated after passing through seven tank process 16 SWG CRCA MS sheet and lockable doors should be provided in canopy with lockable fuel filling arrangement provided external to the canopy. The exhaust system and noise suppressor shall be provided with thermal insulation by using fire retardant/non igniting foam to prevent excess heat radiation on the engine and safe for operator. Absorption type non resistance residential silencer shall be provided to suppress exhaust noise from the engine. (d) Alignment and fuel tank : Alternator and engine aligned on a common 14 SWG CRCA MS base frame complete with MS fuel tank, fabricated out of 16 SWG CRCA MS sheet and is part of base frame (e) Maintenance spares :- (i) Fuel filter element - 02 Nos (ii) Oil fileter element - 03 Nos (iii) Element air cleaner outer - 06 Nos (iv) Element air cleaner inner - 06 Nos (v) 'V' belt - 02 Nos (vi) Filter lubricant oil bypass - 02 Nos (f) DG set shall be supplied along with acoustic enclosure of the manufacturer suitable for 30 KVA DG set as per CPCB norms.
Supply and fixing ON LOAD change over switch 4 pole of capacity 125 Amps, 415V in sheet metal enclosure complete all as specified and directed.
Supply and fixing ON LOAD change over switch 4 pole of capacity 63 Amps, 415V in sheet metal enclosure complete all as specified and directed.
Supply, laying and testing XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3.5 core complete all as specified and directed.
Supply, laying and testing XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq mm 3.5 core complete all as specified and directed.
M & L for Earthing complete with galvanised steel earth plate, electrode, 600x600x6.0 mm thick burried directly in ground (earth pit not less than 2.25m deep below normal ground level) connected to GI strip 32x6mm thick by means of nuts, bolts, & washers of GI as shown in electrical plate No. 5 of SSR Part-I Connected to earthing ten point all as specified and including necessary earth pit PCC 1:3:6 chamber, 50mm thick PCC 1:2:4 chamber cover with 8mm dia mild steel reinforcement of 10 cm c/c spacing both ways in lieu of CI cover, watering arrangement shall be made with GI pipe light grade of 20mm dia including funnel and protection to earth lead shall be provided with GI pipe light grade 15mm dia upto 7.5 from the earth plate electrode & refilling of soil etc including necessary excavation & earth work in any strata complete all as specified and directed.
G N Constructions
yattoo contractors
M/S NORTHERN ELECTRICAL WORKS
M/S SHEIKH FEROOZ AHMAD
ALCO ENGINEERSPVT LTD
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .