Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.1 LAccepted-AOC DOOR NO IV 400 NEAR RAMANTHALI GHSS RAMANTHALI PO KANNUR 670308 | KANNUR | KERALA | 670308 | L1 | Accepted-AOC BEING LOWEST BIDDER | |
| 2 | L2₹51.8 L+₹2.7 L (5.58%)Rejected-Finance | L2 | Rejected-Finance being L2 | |
| 3 | L3₹52.1 L+₹3.0 L (6.08%)Rejected-Finance NO 68 ANJANEYA TEMPLE CROSS OPP M S RAMAIAH HOSPITAL NEW BEL ROAD BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | L3 | Rejected-Finance being L3 | |
| 4 | L4₹53.1 L+₹4.0 L (8.22%)Rejected-Finance NO 3 KEMPANNA ROAD MARUTHI SEVA NAGAR POST BANGALORE 560 033 BANGALORE KARNATAKA | BENGALURU URBAN | KARNATAKA | 560033 | L4 | Rejected-Finance being L4 | |
| 5 | L5₹53.3 L+₹4.2 L (8.62%)Rejected-Finance 121004 | L5 | Rejected-Finance being L5 |
Tender Value
₹50.0 L
EMD Value
₹99,900
Closing Date
13 Aug 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF SULUR
Garrison Engineer AF Sulur Military Engineer Services Kangayampalayam Post Sulur Coimbatore 641 401
REPAIR MAINT OF CENTRAL AND PACKAGE TYPE ACS AND OTHER MISC WKS AT AFS SULUR
2020_MES_363893_1
8335/E8
Open Tender
Miscellaneous Works
Item Rate
270 days
GE AF SULUR
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Yes
GE AF SULUR
₹99,900
Yes
7 Sept 2020
24 Jul 2020
14 Aug 2020
24 Jul 2020
13 Aug 2020
7 Aug 2020
24 Jul 2020 - 6 Aug 2020
60 days
Amount
SCHEDULE A BOQ
M&L for complete overhauling of air compressor 20 HP Make Ingersoll including replacement of valve assembly LP-2 Nos, valve assembly HP - 1 No, Piston rings LP-2 sets, Piston Rings HP - 1 set, Air filter element - 2 No, Gasket set - 1 set and compressor oil - 5 ltr etc testing complete all as specified and as directed by Engineer in Charge. Note :- Repairs/ maintenance shall be carried out through the Authorised service agency only as per instructions recommended by the original manufacturer.
Taking down Compressor Motor of capacity 50HP from location for servicing including replacement of bearing,bush and rewinding and refixing the same .Make-ABB or existing make/ brand of defective components/ spare part or any reputed suitable make as approved by the Engineer-in-Charge.
Taking down old unserviceable scroll type compressor of capacity 7.5 TR including Supply and fix of same capacity and model of compressor, Model No. SM 120S4VC of Danfoss Make or existing make/ brand of defective components/ spare part or any reputed suitable make as approved by the Engineer-in-Charge.
Supply and replacement unserviceable of Quick discount coupling of size 15mm dia Model- HI-CUPLA suitable for connection of PVC air pipe and pressure air regulating valve Make - Nitto Khoki Co Ltd or equivalent suitable make as directed by Engineer-in-Charge..
Supply and fix in repair Blower fan motor suitable for AC plant 2X15 TR at TRCL,Make -Hindustan or existing make/ brand of defective components/ spare part or any reputed suitable make as approved by the Engineer-in-Charge.
Servicing of chiller pump 5HP 3 phase 415 Volt including replacement of unserviceable bearing bush with testing and commissioning .Make Kirloskar
Supply and fix in repair AHU Blower motor with blower set of MAKE suitable for the 3X16.5 TR precision type AC plant at Transmitter (Opera-I).
Comprehensive maintenance of 25 KVA static frequency converter with input supply of 3 phase 415 V, 50 Hz with output of 3 ph 4 wire 115 AC /200 V AC 400 HZ Make- Power one Micro systems including attending day to day complaints, Isolating converter from system, opening up, examining the accessories parts, cleaning , soldering as required and testing and connecting back with the systems as directed by the Engineer-in-charge. Location - LCA Hanger No-I,II & III-09 Nos. Note :- (a) The contractor shall make AMC contract with the original manufacturer of the equipments and the repairs/ maintenance shall be carried out through the Authorised service agency only as per instructions recommended by the original manufacturer. (b) The authorised service agency must be attended as and when called for urgent nature of repair of the equipments. (c) Any minor items to be replaced is included in the item quoted rate. (d) Payment shall be made twice proportionately during the entire contract period for comprehensive maintenance.
Comprehensive maintenance of Air compressor 10 HP of make : ELGI 3 phase including attending day to day complaints, checking of airflow line, oil change, pressure switch setting, setting of air filters, checking functioning of valves, checking of guage by the original manufacturer complete all as specified and directed. Location- SES Bldg, FOL Lab T-68 Hanger. Note :- (a) The contractor shall make AMC contract with the authorised service agency of any make /manufacture of equipments and the repairs/ maintenance shall be carried out through the Authorised service agency only as per instructions recommended by the original manufacturer. (b) The authorised service agency must be attended as and when called for urgent nature of repair of the equipments. (c) Any minor items to be replaced is included in the item quoted rate. (d) Payment shall be made twice proportionately during the entire contract period for comprehensive maintenance.
S&F in repair strainer of package type ac plant of capacity 12TR with ISI mark
Supply and replacement unserviceable of PVC compressed air pipe of 15mm dia suitable for 150 PSI as directed. Make : Presto Plast/ Modi/ Avon Plast
Supply and replacement of Gasket full set of compressor of Model: 5H – 40 voltas make capacity 3 × 30 TR Rubber store.
Supply and fix in repair AHU Blower motor with blower set of MAKE suitable for the 12 TR precision type AC plant at AVRO/ Opera-II.
Comprehensive maintenance of DC power supply (rectifier) 28 Volts DC out put 12 KW with input supply of 3 phase 415 V, 50 Hz Make- Power one Micro systems including attending day to day complaints, Isolating converter from system, opening up, examining the accessories parts, cleaning , soldering as required and testing and connecting back with the systems as directed by the Engineer-in-charge. Location - LCA Hanger No-I, II & III - 09 Nos. Note :- (a) The contractor shall make AMC contract with the original manufacturer of the equipments and the repairs/ maintenance shall be carried out through the Authorised service agency only as per instructions recommended by the original manufacturer. (b) The authorised service agency must be attended as and when called for urgent nature of repair of the equipments. (c) Any minor items to be replaced is included in the item quoted rate. (d) Payment shall be made twice proportionately during the entire contract period for comprehensive maintenance.
Supply and replacement of unserviceable Timer unit of 3X30TR AC plant at Rubber store
Supply and fix in repair AHU Blower motor with blower set of MAKE suitable for the 15 TR precision type AC plant
Supply and replacement of unserviceable CTV Coil incoming 230Volt outgoing 12V/24V of existing make/ brand of defective components/ spare part or any reputed suitable make as approved by the Engineer-in-Charge.
Single phase preventer with suitable wiring for starter control panel including taking down unserviceable worn out single phase preventer complete all as specified and directed
Supply and fix in repair microprocessor Controller suitable for 15TR AC plant at TRCL
M&L taking down AHU Motor of capacity 10HP from location for servicing including replacement of bearing,bush and rewinding and refixing the same .
Supply and replacement of Shaft seal and seal cover plate of compressor of Model: 5H – 40 voltas make capacity 3 × 30 TR Rubber store.
Supply and fix in replacement of contactor 3 Phase 415 Volt suitable for AC plant of capacity 1X12TR at Opera II. Make : Siemens, ABB, Schneider, L&T
Comprehensive repair and maintenace of frequency converter 4 KVA capacity 3 phase, phase voltage 415+/-5% ,50HZ +/-1% AC system for an output of 3 Phase 200 V, 400 HZ or single phase 115 V ,400HZ with variation in voltage of +/-2% and variation in frequency of +/-1%, 5 times in a year. Make -Aplab, Location -33 Sqn New Hangar complete all as specified and directed. . Note :- (a) The contractor shall make AMC contract with the original manufacturer of the equipments and the repairs/ maintenance shall be carried out through the Authorised service agency only as per instructions recommended by the original manufacturer. (b) The authorised service agency must be attended as and when called for urgent nature of repair of the equipments. (c) Any minor items to be replaced is included in the item quoted rate. (d) Payment shall be made twice proportionately during the entire contract period for comprehensive maintenance.
Comprehensive maintenance of Air compressor 3 HP of Make : ELGI 3 phase including attending day to day complaints, checking of airflow line, oil change, pressure switch setting, setting of air filters, checking functioning of valves, checking of guage by the original manufacturer complete all as specified and directed. Location- T-68 Hanger Note :- (a) The contractor shall make AMC contract with the authorised service agency of any make /manufacture of equipments and the repairs/ maintenance shall be carried out through the Authorised service agency only as per instructions recommended by the original manufacturer. (b) The authorised service agency must be attended as and when called for urgent nature of repair of the equipments. (c) Any minor items to be replaced is included in the item quoted rate.
Supply and Fix Sealed Maintenance Free (SMF) battery of capacity 12 V. 100 AH, suitable for existing 3 phase 40 KVA/50KVA online UPS as required at location:-Gen Set Room (TRCL)-01 No, IT Section-01 No to the concerned UPS including initial charging complete with inbuilt charger including electrolyte/ distilled water etc including taking down of old battery and shifting to MES store yard for deposit all as directed by engineer in charge complete all as specified. Make of battery : Exide of model No. EP 65 or equitant in Amar raja (Power Zone)/ Amaron Note :- The contractor shall submit full replacement warranty certificate for minimum 02 years from the date of installation. (ii) The contractor shall supply SMF battery as per requirement given by Engineer-in-Chare throughout the currency of contract.
Taking down unserviceable MCCB, supply and fixing MCCB 400 amps 50 KA 4 pole 415Volts including connection using suitable size of aluminium lugs. Make : L&T, ABB, Schneider
Comprehensive maintenance of Air compressor 20 HP of Make : Ingersoll 3 phase including attending day to day complaints, checking of airflow line, oil change, pressure switch setting, setting of air filters, checking functioning of valves, checking of guage by the original manufacturer complete all as specified and directed. Location- LCA Hanger No.I,II& III -03 Nos. Note :- (a) The contractor shall make AMC contract with the authorised service agency of any make /manufacture of equipments and the repairs/ maintenance shall be carried out through the Authorised service agency only as per instructions recommended by the original manufacturer. (b) The authorised service agency must be attended as and when called for urgent nature of repair of the equipments. (c) Any minor items to be replaced is included in the item quoted rate.
Taking down old unserviceable outdoor condenser from existing unit and Supply and fix new outdoor condenser of same Model suitable for the AC plant 1x8.75 TR at T-51
S&F water pressure cut out 230 volt including taking down existing one. Make Indfoss or equivalent.
Supply only Refrigerant gas R – 22 as and when required for AC plants of following capacity
(a) 3 × 30 TR Rubber store of Voltas make
(b) 2 x 7.5 TR for TRCL of Voltas make
S&F in repair LP HP cut out 230 volt, Make Indfoss or equivalent
Supply and fix in repair condenser fan motor of outdoor unit of AC plant Avro12TR
S&F Oil pressure cut out of existing make/ brand of defective components/ spare part or any reputed suitable make as approved by the Engineer-in-Charge..
M&L for complete overhauling of air compressor 10 HP Make Ingersool/ shakti/ ELGI including replacement of valve assembly LP-2 Nos, valve assembly HP - 1 No, Piston rings LP-2 sets, Piston Rings HP - 1 set, Air filter element - 2 No, Gasket set - 1 set and compressor oil - 5 ltr, etc testing complete all as specified and as directed by Engineer in Charge.
Supply and replacement of contactor 3 Phase 415 Volt suitable for AC plant of capacity 3X30 TR,Model No.3TF34 of Make : Siemens, L&T, ABB
Supply and replacement of unserviceable motor protection devices of Make : L&T, BCH & Schneider
M&L for Compressor Oil freeze -90LTR,Make:Castrol, Shell , Servo
Supply and fix in replacement of contactor 3 Phase 415 Volt suitable for AC plant of capacity 3X45TR at Rotable Div and 2x7.5 TR at TRCL : Make-Siemens, ABB, Schneider, L&T.
Taking down unserviceable MCCB, supply and fixing MCCB 200 amps 36 KA 4 pole 415Volts including connection using suitable size of aluminium lugs. Make : L&T, ABB, Schneider
Supply and replacement of Big end Bearing of compressor of Model: 5H – 40 voltas make capacity 3 × 30 TR Rubber store.
Supply and replacement of Small end Bearing of compressor of Model: 5H – 40 voltas make capacity 3 × 30 TR Rubber store.
Supply and fix in repair condenser fan motor of outdoor unit of AC plant CRRW of 15 TR of existing make/ brand of defective components/ spare part or any reputed suitable make as approved by the Engineer-in-Charge.
Supply and fix in repair condenser fan motor of outdoor unit of AC plant Transmitter 3X16.5 TR
Comprehensive repair and maintenace of frequency converter 1.25 KVA capacity 3 phase, phase voltage 415+/-5% ,50HZ +/-1% AC system for an output of 3 Phase 200 V, 400 HZ or single phase 115 V ,400HZ with variation in voltage of +/-2% and variation in frequency of +/-1%, 5 times in a year. Make -Aplab, Location -33 Sqn New Hangar. Note :- (a) The contractor shall make AMC contract with the original manufacturer of the equipments and the repairs/ maintenance shall be carried out through the Authorised service agency only as per instructions recommended by the original manufacturer. (b) The authorised service agency must be attended as and when called for urgent nature of repair of the equipments. (c) Any minor items to be replaced is included in the item quoted rate. (d) Payment shall be made twice proportionately during the entire contract period for comprehensive maintenance.
M & L contactor 4 pole 63 Amps Make: L&T, ABB, Schneider
Supply and fix in replacement of condensor contactor 3 Phase 415 Volt suitable for AC plant of capacity 3X30 TR,Model No.3TF30. Make : Siemens, L&T, Schneider, ABB
Supply and Fix Sealed Maintenance Free (SMF) battery of capacity 12 V, 65 AH, suitable for existing 3 phase 20 KVA/25KVA online UPS as required at location:- old TRCL-3 No’s, New TRCL-6 Nos to the concerned UPS including initial charging complete with inbuilt charger including electrolyte/ distilled water etc including taking down of old battery and shifting to MES store yard for deposit all as directed by engineer in charge complete all as specified. Make of battery : Exide of model No. EP 65 or equivalent in Amar raja (Power Zone)/ Amaron Note :- (i) The contractor shall submit full replacement warranty certificate for minimum 02 years from the date of installation. (ii) The contractor shall supply SMF battery as per requirement given by Engineer-in-Chare throughout the currency of contract.
Excavation in trenches not exceeding 1.5 m wide and n.exc. 1.5 m deep in depth in hard/ dense soil and getting out
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in hard and dense soil
Removing excavated material n.exc. 50m and depositing where directed at a level n.exc. 1.5 m above the starting point.
Riddling Sand obtained from excavation for cable protection 8cm under the cable and 15cm above the cable in trench and get the thick layer of 18cm after ramming. Note :- In case sufficient sand not obtained from excavation, the required additional qty obtain from out side land as directed by the Engineer-in-Charge. The rate is deemed to be included.
Fly ash cable protection cover of size 23x11.5 x7.5cm including taking down existing bricks of any size.
XLPE insulated, screened, PVC Bedded, galvanised steel strip of wire armoured, electric power cable heavy duty with aluminium condutor 1100Volts grade cross sectional area 16 Sqmm 4 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets, taking down existing cable etc all as specified and directed. Note : Excavation and earth work shall be measured and paid seperately. Make : Havells/ NICCO/ Polycab
XLPE insulated, screened, PVC Bedded, galvanised steel strip of wire armoured, electric power cable heavy duty with aluminium condutor 1100Volts grade cross sectional area 25 Sqmm 4 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets, taking down existing cable etc all as specified and directed. Note : Excavation and earth work shall be measured and paid seperately. Make : Havells/ NICCO/ Polycab
Supply only Refrigerant gas R – 407 C as and when required for AC plants of following capacity
(a) 8.75 TR for T/51 Plant
(b) 3 x 16.50 TR for Transmitter plant
(c) 12 TR for Avro plant
(d) 12 TR for signal section and OTF
(e) 15 TR for CRRW,SEW
(f) 3X45 TR for Rotable Division (P-26)
(g) 16 TR for Clean Room (P-15)
Supply and replacement of unserviceable outdoor condensor fan motor of capacity single phase 0.5HP, 900 Rpm,suitable for AC plant at TRCL.
Supply and replacement of Valve plate assembly of compressor of Model: 5H – 40 voltas make capacity 3 × 30 TR Rubber store.
S&F AHU fan motor including blower 230 volt,Make:GEA
Supply and replacement of Piston with rings (Oil ring / pressure ring) of compressor of Model: 5H – 40 voltas make capacity 3 × 30 TR Rubber store.
Supply and fix in replacement of compressor contactor 3 Phase 415 Volt suitable for AC plant of capacity 3X30 TR, Model No.3TF46, Make : Siemens, L&T, Schneider, ABB
Comprehensive maintenance of Air compressor 10 HP of make : Ingersoll 3 phase including attending day to day complaints, checking of airflow line, oil change, pressure switch setting, setting of air filters, checking functioning of valves, checking of guage by the original manufacturer complete all as specified and directed. Location- LCA Hanger No.I,II& III -06 Nos. Note :- (a) The contractor shall make AMC contract with the authorised service agency of any make /manufacture of equipments and the repairs/ maintenance shall be carried out through the Authorised service agency only as per instructions recommended by the original manufacturer. (b) The authorised service agency must be attended as and when called for urgent nature of repair of the equipments. (c) Any minor items to be replaced is included in the item quoted rate. (d) Payment shall be made twice proportionately during the entire contract period for comprehensive maintenance.
Supply, installation, commissioning and testing of Factory assembled, Floor mounted, free standing, type tested LT Feeder Pillar Panels, with canopy, as per electrical specifications for outdoor installation, to be made of IP65 Polycarbonate modular enclosures. The Enclosures made of Polycarbonate, should be weather/ vermin proof, anti-acid, anti-corrosive, UV resistance in accordance with IEC 61439-1, Fire retardant and Self-extinguishing in accordance with IEC 60695-2-11, UL subject 94 for flammability V-0, should pass glow wire test for 960° in accordance with 60695-2-11. Degree of protection against mechanical load should be IK 08 (5 Joule) in accordance with IEC 62262, IP 65 in accordance with IEC 60529 & IEC60439-1, should have Dielectric Properties, RoHS compliant & Halogen free. The manufacturer of boards/panel shall submit a copy of type test reports as per above-mentioned norms either from UL/ERDA/CPRI/NABL labs in India. The panels should be modular and compartmentalized in construction with opaque and transparent doors, properly tightened to base with thermoplastic screws having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosures should be above 200mm for air circulation & to minimize temp rise. Panel should be fitted with 01 No polycarbonate IP 65, 9W LED translucent bulk head luminaire, 6500K, PF > 0.95 under canopy for easy maintenance. Panel should be fitted outside with 01 No of 16A 3P IP 65 industrial socket and 01 No of 32A 5P IP 65 industrial socket. 3 phase and neutral 400 amps current carrying capacity copper bus bar insulated with colour coded heat shinkable sleeves with SMC/DMC insulators, complete with the following switch gears and mounting the panel board on ground with PCC (1:3:6) bedding upto a height of 45 cm above ground level, including dismantling and taking out old u/s LT Panel Board and remove from site reconnecting existing LT Cables with new panel board complete all as directed :-
S/F voltage fluctuation sensor unit including taking down existing one.
Taking down unserviceable MCCB, supply and fixing MCCB 100 amps 25 KA 4 pole 415Volts including connection using suitable size of aluminium lugs. Make : L&T, ABB, Schneider
Taking down unserviceable MCCB, supply and fixing MCCB 63 amps 25 KA 3 pole 415Volts including connection using suitable size of aluminium lugs. Make : L&T, ABB, Schneider
Supply and replacement of Connecting Rod Pin of compressor of Model: 5H – 40 voltas make capacity 3 × 30 TR Rubber store.
Supply and replacement of Oil pump assembly with gear of compressor of Model: 5H – 40 voltas make capacity 3 × 30 TR Rubber store.
Taking down unserviceable MCCB, supply and fixing MCCB 125 amps 25 KA 4 pole 415Volts including connection using suitable size of aluminium lugs. Make : L&T, ABB, Schneider
Comprehensive maintenance of Air compressor 2 HP of Make : ESKAY 3 phase including attending day to day complaints, checking of airflow line, oil change, pressure switch setting, setting of air filters, checking functioning of valves, checking of guage by the original manufacturer complete all as specified and directed. Location- FOL Lab, 5 BRD Note :- (a) The contractor shall make AMC contract with the authorised service agency of any make /manufacture of equipments and the repairs/ maintenance shall be carried out through the Authorised service agency only as per instructions recommended by the original manufacturer. (b) The authorised service agency must be attended as and when called for urgent nature of repair of the equipments. (c) Any minor items to be replaced is included in the item quoted rate.
Supply, installation, commissioning and testing of Factory assembled, Floor mounted, free standing, type tested LT Feeder Pillar Panels, with canopy, as per electrical specifications for outdoor installation, to be made of IP65 Polycarbonate modular enclosures. The Enclosures made of Polycarbonate, should be weather/ vermin proof, anti-acid, anti-corrosive, UV resistance in accordance with IEC 61439-1, Fire retardant and Self-extinguishing in accordance with IEC 60695-2-11, UL subject 94 for flammability V-0, should pass glow wire test for 960° in accordance with 60695-2-11. Degree of protection against mechanical load should be IK 08 (5 Joule) in accordance with IEC 62262, IP 65 in accordance with IEC 60529 & IEC60439-1, should have Dielectric Properties, RoHS compliant & Halogen free. The manufacturer of boards/panel shall submit a copy of type test reports as per above-mentioned norms from UL/ERDA/CPRI/NABL labs in India. The panels should be modular and compartmentalized in construction with opaque and transparent doors, properly tightened to base with thermoplastic screws having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosures should be above 200mm for air circulation & to minimize temp rise. Panel should be fitted with 01 No polycarbonate IP 65, 9W LED translucent bulk head luminaire, color temp not less than 6500K, PF > 0.95 under canopy for easy maintenance. Panel should be fitted with 01 No of 16A 3P IP 65 industrial socket and 01 No of 32A 5P IP 65 industrial socket outside. 3 phase and neutral 600 amps current carrying capacity copper bus bar insulated with colour coded heat shinkable sleeves with SMC/ DMC insulators, complete with the following switch gears and mounting the panel board on ground with PCC (1:3:6) bedding upto a height of 45 cm above ground level, including dismantling and taking out old u/s LT Panel Board and remove from site reconnecting existing LT Cables with new panel board complete all as directed :-
M&L Earthing with Galvanised Earth Plate Electrode 600x600x 6mm thick burried directly in Ground (Earth Pit not less than 2.25 Metre below Ground Level) with Top edge of the Plate not less than 1.50 Metre below Ground Level, connected with Galvanised Earth Strip of size 25x6mm by means of Bolts, Nuts, Check Nuts and Washers of GI or Steel and connected Earthing Testing Point/Bus-bar including GI 40mm bore (dia) light grade Protection Pipe, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt, Magneisum Sulphate (1 : 1 : 0.5) in alternate layers of not exc 150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of size 350x350x50 mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, Funnel with GI Watering Pipe 20mm bore (dia) medium grade including necessary Excavation in any type of Soil, Returning, Filling in and Removal of surplus Spoil upto a distance of 50.00 Metre and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion including taking down old unserviceable one, complete all as per specified and as directed.
(a) All Joints should be joined by Exothermic Welding or Brazing. (b) After completion of work earthing shall be tested by the contractor in presence of Engineer-in-Charge, User and proper record shall be maintained duly signed by all concerned. (c) Earth resistance tester shall be provided by the contractor. It should be caliberated from authorised company/ lab. (d) After testing if desired earth vesistance of less than 5 Ohm is not obtained, the earthing will be redone at no extra cost to Govt till desired result is obtained. (e) The length of the earth strip upto and including 7.5m is included in quoted rate.
Note for item Nos 2-26, 28-49, 58-71 & 74-80 :- (a) In case of any delay in attending the complaint after handing over routine/urgent complaints, the contractor shall be liable to pay the penalty as described in penalty clause given here as under.
(b) In case of minor defect, entire Job shall be completed within 12 hrs from the time of registration of complaint, failing which penalty charges @ Rs. 500/- per hours shall be recovered.
(c) In case of major defect, the period for attending of complaint shall be decided by the GE/EIC by accessing extent of repair required through joint inspection by Engineer-in-Charge and authorised service agent of the equipment at the site. If equipment is not rectified within the stipulated period and the GE is not satisfied with the reason for delay, then penalty at the rate of Rs. 1000- per hours shall be deducted from the dues of the contractor.
(d) Please note that above penalty is exclusively other than the condition 56 of IAFW - 2249 and shall be treated as interim condition of the contract and shall be enforce above as and when delay in individual job is noticed and no claim whatsoever on this account shall be entertained by the Deptt.
(e) The decision of the Accepting Officer in this regard shall be final and binding.
eurekaenterprises
devan enterprises
M AND V ENTERPRISES
Neptune Engineers and Builders
UNIVERSAL ENGINEERING
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .