| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.8 LAccepted-Finance MOHISHILA COLONY ASANSOL 713303 | ASANSOL | PASCHIM BARDHAMAN | WEST BENGAL | 713303 | ₹6.8 L | L1 | Accepted-Finance Accept |
| 2 | L2₹6.9 LRejected-Finance ASANSOL | ASANSOL | ₹6.9 L | L2 | Rejected-Finance Reject |
| 3 | L3₹7.0 LRejected-Finance 22 LASKARDIGHI WEST DIST PURBA BARDHAMAN | PURBA BARDHAMAN | WEST BENGAL | ₹7.0 L | L3 | Rejected-Finance Reject |
Tender Value
₹7.0 L
EMD Value
₹13,944
Closing Date
3 Feb 2026, 3:00 pmClosed
Superintending Engineer
Asansol Municipal Corporation
LAYING, TESTING AND COMMISSIONING OF 150 MM DIA DI K7 PIPE LINE FOR INTERCONNECTION OF PHE PIPE LINE TO AMC DISTRIBUTION MAIN AT USHGRAM OHR AND MAIDAKAL MORE UNDER ASANSOL MUNICIPAL CORPORATION.
2026_MAD_994228_1
ET-72 /WS/Eng/2026
Open Tender
Miscellaneous Works
120 days
Asansol Municipal Corporation
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹13,944
11 Apr 2026
27 Jan 2026
5 Feb 2026
27 Jan 2026
3 Feb 2026
27 Jan 2026
Dismantling all types of plain cement concrete works, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. In ground floor including roof.(a) upto 150 mm. thick
Cost iron double flanged manually operated sluice valves generally conforming to IS 14846 : 2000, having four faces and spindle nut of gunmetal, inside screw non- rising type quality gunmetal /AISI 410 spindle: seat tested to 10kg/CM2 and body tested to 15kg/CM2, flanges flat faced and drilled to 1S. : 1538 : 1993. Painted black all over with asphalt base paint. Valves tested by closed end method. 100 MM DIA
150 MM DIA
Supplying, fitting and fixing of C.I. Mechanical Compression Long Sleeve Collar Coupling (popularly known as Cut-N-Repair Coupling) suitable for jointing C.I. Spun Pipes (as per IS: 1536) and D.I. Pipes (as per IS: 8329) with BS:1211 Class-B Pipes. The Couplings will be supplied complete with Sealing Rubber Gasket of EPDM quality (IS:5382/1985 Type-4), Cast Iron Follower Glands and Mild Steel (Zinc Coated) Nut Bolts . The whole assembly should be mechanically and hydraulically tested to the provisions as laid down in IS: 1538. Fitting and fixing should be in proper position with proper care of main pipe line for leak proof condition. 150mm with length 300mm.
Supplying, fitting and fixing of C.I. Mechanical flexible Flange Socket Tailpiece suitable for making flanged connection with the plain barrel of C.I. Spun Pipes (as per IS : 1536) and D.I. Pipes (as per IS : 8329). The Tailpieces to be supplied complete with Sealing Rubber Gasket of EPDM quality (IS:5382/1985 Type-4), Cast Iron Follower Glands and Mild Steel Nut Bolts (Zinc Coated). The whole assembly should be mechanically and hydraulically tested to the provisions as laid down in IS: 1538. Fitting and fixing should be in proper position with proper care of main pipe line for leak proof condition. 150mm with length 100mm
Carriage of different type of departmental pipes from Divisional/Sub-divisional store to the work site by truck including loading, unloading, stacking etc. including cost of fuel, lubricant and also cost of driver, helper etc. and all other taxes and charges as applicable as per direction of EIC b) Above 5 Km upto 10 Km
Supplying, laying, fiting, fixing and jointing of UPVC pipes conforming to IS:4985-2000 with latest revision and amendments, if any, with necessary UPVC/CI specials, CIDF sluice valves, as per relevant I.S. specification including labour charges for earth work in excavation in any kind of soil including mixed soil with boulder ,road sub-grade and its flanks but excluding moorum and laterite or sand stonehard arock including cutting of brick payment without damaging the existing telephone/electrical cable line etc.(in case of damage of any type of cable line during excavation, necessary damaged charges as applicable by the respaective authority will be borne by the agency in his own cost. Loading, unloading, carrying of pipes, specials, valves from the local store to work site and lowering laying of pipes specials valves carefully in trenches maintaining proper levels and alignment ,jointing the pipe and specials including supplying of good quality/approved brand solvent cement (as per IS:14182-1994 including cost of all fabricated PVC fittingi.e. tees,bend, reducers, adopter etc.as per IS:101-1988 and making flange joints including supplying required quantity of nuts, bolts andrubber insertion (CIDF sluice valves will be supplied by the departmentfree of cost) as required at site by adopting suitable method so as tofacilate the maintenance of pipe line locally as per conventional method including back filling the trenches with good earth obtained from excavation of trenches including consolidation with watering in layer not exceeding 150mm thk. with maintaining an average depth of cushion of 1.10mtr. from the top of pipe line including making interconnection with distribution pipes etc. all complete as per drawingdirection and satisfaction of the E.I.C. N.B. i) Manufacturer’s test certificate for UPVC pipe & specials to be produced before laying of pipe line. Laying of pipe line including cost of pipe only excluding cost of specials/fittings & valves. 110 MM DIA
Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity) (B) Do - by fine sand
Carrying CI/DI pipes with specials and valves and lowering placing in position and laying carefully inside the trenches in proper alignment and gradient etc. including earth work in excavation of adequate width as per specification having min. clear cover from top of pipe is 1.10mtr. below existing ground level in any kind of soil including mixed with boulder,road sub-grade and its flank,but excluding moorum and laterite and stone etc.without damaging the exisiting telephone/electric cable etc.(in case of damaged if any type of cable line during excecution , necessary damaged charges as applicable by the respective authority will be borne by the agency in his own cost) preparing the bottom surface for continuous bedding of pipe line and laying pipes, fitting, fixing specials and valves with bailing out water if any including carriage of pipes, specials and valves from local deptt. store within 8KM and back filling the trenches with excavated earth in layers to original condition as per specification and direction of EIC. The surplus materials after execution of work are to be return to the deptt. store. N.B: i) Any deviation from required clear cover of 1.10mtr., due to site adverse condition, prior permission is to be obtained from the EIC in exceptional situation and payment will be made on prorate basis over the rate of entire item ii) No payment will be made without hydraulic test of the pipe line either part or full iii) The pipes, specials and valves , rubber gasket will be supplied deptt. free of cost. 200 MM DIA
150 MM DIA
250 MM DIA
Supply of E.R.W.M.S. (Electrical Resistant Welded M.S.) black pipe of ISI mark as per relevent IS Specification (heavy quality) having wall thickness not less than 8 mm. [N.B.: The rates for supply of TATA Make pipe will be arrived at by adding 20% of the corresponding rates ] 200 mm dia.
Supplying including cost of installation of C.I. Mechanical joint Tee as dimensionally described in IS:13382/2004. Each Tee consists of One C.I. Body, Two C.I. Follower Glands, Two sealing Rubber Gaskets of EPDM quality (Conforming to IS:5382/1985 Type-4) and Zinc coated M.S. Fasteners. The Branch Flange is drilled as per IS: 1538. The whole assembly is mechanically and hydraulically tested to provisions as laid down in IS: 13382/2004 of 150 x 150 x 150
Supplying, fitting and fixing of C.I. Mechanical Compression flexible Collar Couplings suitable for C.I. Spun Pipes (as per IS: 1536) and D. I. Pipes (asper IS: 8329) complete with Sealing Rubber Gasket of EPDM quality(IS:5382/1985 Type - 4), Cast Iron Follower Glands and Mild Steel NutBolts (Zinc Coated). hydraulically tested to the provisions as laid down in IS: 1538. Fittingand fixing should be in proper position with proper care of main pipe line for leak proof condition. 250 MM DIA
Supplying including cost of installation of C.I. Mechanical joint End Cap as dimensionally described in IS:13382/2004. Each Cap consists of oneC.I. Body, one C.I. Follower Glands, one sealing Rubber Gaskets of EPDMquality (Conforming to IS: 5382/1985 Type-4) and Zinc coated M.S.Fasteners of adequate numbers. The whole assembly is mechanically andhydraulically tested to provisions as laid down in IS: 13382/2004.
Supply of M.S. Flange (slipper type) as per IS-6392 TABLE 17 Thickness 12mm 80 MM
Supply of E.R.W.M.S. (Electrical Resistant Welded M.S.) black pipe of ISI Mark as per relevent IS Specification (heavy quality) having wall thickness not less than 5 mm. [N.B.: The rates for supply of TATA Make pipe will be arrived at by adding 20% of the corresponding rates ] 80 MM DIA
200 MM DIA
Gas cutting of M.S. pipes and/or M.S. plates of different thickness all complete as per specification and direction of the Engineer-in- charge. 12mm thick plate
Hire charges of lighting generator of capacity 5KVA including fuel,mobil, operator, carriage etc. including all complete for water supplyworks.For minimum engagement of 8 hrs. in a day
Wet connection with M.S. saddle on running mains by drilling with electric drill, plugging with wooden plug, using nuts and bolts, rubber insertion, dewatering trenches all complete excluding cost of M.S. saddle &Earthwork. 12in /4in dia
Construction of different dia Sluice valve /Air valve /Washout chamber in different sizes for village road where light traffic run and for main road where heavy traffic run as deptt.approved drawing with 25cm thick brick work (1:6) over cement concrete (4:2:1) over a single brick flat soling over 150mm.thick sand filling in foundation including earth work in excavation and disposal of excess earth from work site with RCC (1:1.5:3) cover slab 100mm / 150mm thick slab on top of chamber with 1% reinforcement in RCC cover slab with necessary opening for operation of valve all completeincluding cost of labour & materials as per Departmental Dwg. [Reinforcement type:Other manufactuerers not specified] i) 80 mm to 150 mm dia pipe
Hire charges of moveable type mounted earth excavator having minimum cutter size (1.0 cubic meter) & loader size (2.0 meter length x 0.75m width) for cutting & removal of any kind of soil, spoli etc. including cost of fuel, lubricants & manpower etc. in Water Supply Works. [This item will be operated on prior permission from the concerned SE/Dy. Chief Engineer] For minimum engagement of 8 hrs. in a day
M.S. structural works in columns, beams etc. with simple rolledstructural members (e.g. joists, angle, channel sections conformingto IS: 226, IS: 808 & SP (6)- 1964 connected to one another with bracket, gussets, cleats as per design, direction of Engineer-incharge complete including cutting to requisite shape and length, fabrication with necessary bolting, metal arc welding conforming to IS: 816- 1969 & IS: 1995 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools andplants and labour required for the work including all incidental chages such as electricity charges, labour insurance charges etc.Payment to be made on the basis of calculated weight of structuralmembers only in finished work as per IS specified weight. Payment for gusset, bracket, cleat, rivets, bolts and nuts may be make by adding the actual weight of such items with the weight of finished structural members or 7% of weight for finished structural members weighing not less than 22.5 Kg. / m. or 15 % of weight for finished Structal members weighing less than 22.5 Kg. / m. may be increased allow for bracket, cleat, rivet, bolts and nuts etc. and no seperate payment being made for these items, as per direction of Engineer In Charge. The rates are considered for a height of erection 8m. / 2nd floor level from the ground. Add 1.5% extra over the rate for each additional floor or 4m. beyond initiial 8m. or part thereof.
Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. (i) Pakur Variety
Add GST @ 18%
Add CESS @1%
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
techsummary_2432272.pdf
fin_bid_open.pdf