Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance 249 SHALIMAR SHAMLI | SHAMLI | SHAMLI | UTTAR PRADESH | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Not Admitted-Fee/PreQual/Technical | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
Refer Docs
EMD Value
₹21,400
Closing Date
27 Nov 2024, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Superintending Engineer
office of the S.E., EUDC-II, Sec-18, Noida.
construction of New 06 no. 0.11/400 KVA SS
2024_PVVNL_967960_2
E-Tender No. 46/2024-25, EUDC-II Noida
Open Tender
Electrical Works
Item Rate
60 days
office of the S.E., EUDC-II, Sec-18, Noida.
Attached in DOC
2 documents required · 2 mandatory
₹3,540
S.E. EUDC-II, Noida.
₹21,400
3 Dec 2024
21 Nov 2024
27 Nov 2024
21 Nov 2024
27 Nov 2024
21 Nov 2024
Amount
Provision of New 250 KVA T/f NEAR E-363 SEC-15, Noida in the area of Substation SECTOR-16 Noida under EUDSD-XI, Noida
Safe carriage of following stock material, from any of the Store Center of PVVNL to work site including Loading from Store and safe unloading at site for Item No. 3 to 14
8.5 Mtr Long PCC Pole
MS Channel (Dropper) 100x50x2028 mm
ACSR Weasle Conductor
Cable LT ABC 3x120+1x95+1x16 Sqmm
MS Top Channel (125x65x2240 mm)
11 KV Disc Insulator T&C type 45 KN
11 KV Disc Fitting
MS Chanel 125x65x1300 mm ( T-Off)
11 KV Poly Pin Insulator
11/0.4 KV T/f 250 KVA
11 KV Fuse Set
LT PVC Cable Al 1x400 Sqmm
Errection of above Following material and Supply and errection of the DE-CENTRALISED material for completing the works as per RESPO.
The excavation of foundation pit in mix soil/normal soil/soft soil & hard rock as per site condition and its back filling and leveling etc. The size of the pit will be (750x450)mm and having depth of 1/6th of the full length of the support. Erection of support, complete with providing & fixing of all G.I.Clamps size of 75x10mm, 65x8mm, G.I.Nut bolt & washer, P.G.Clamp, Stone Pad, Al. Binding wire, 'E' bracket 75x10mm, and other accessories as per drawing. The work includes carriage and handling of supports from sectional store to pit site as well as any fabrication work if required & fixing of cross bracing sets 4.3mtr long, from G.I.Angle 65x65x6mm. The work includes cutting holes and providing G.I.Bolt of 16x40mm size, in the middle of the cross bracing with 01No. spring washer of proper size as per drawing/ as per schedule. Double Pole Structures (a) PCC POLE 8.5MTR
Grouting of supports in CC 1:3:6 (Cement, sand & 20mm stone grift). Grouting will be done in the block of size (450x450)mm x1/6th of full length of the support, upto ground level, 300mm plinth above the ground level with C.C. 1:3:6 (Cement, Course sand and Stone grift) with muffing as per RESPO. Work includes back filling and proper ramming. Single Pole and Double Pole (a) PCC POLE 8.5MTR
FIXING OF MS CHANNEL (DROPPER) 100X50X2028 COMPLETE WORK IN ALL RESPECT.
FIXING OF MS TOP CHANNEL COMPLETE WORK IN ALL RESPECT.
FIXING OF DISC INSULATOR WITH FITTINGS AS PER SITE REQUIREMENT.
FIXING OF T-OFF CHANNEL AS PER SITE REQUIREMENT.
FIXING OF PIN INSULATOR WITH PIN AS PER SITE REQUIREMENT.
FIXING OF 11KV FUSE SET AS PER SITE REQUIREMENT.
CONNECTING OF LT PVC CABLE ALU. 1X400SQMM AS PER SITE REQUIREMENT.
Installation and Commissioning of 11/0.4 KV, 250 KVA T/F Mounted on Plinth as per site requirement and providing & fixing of Lugs & copper L-piece (04 No.) of size 400x50x6mm and making of L.T.Connections with complete work in all respects.
Laying, Sagging and Re-Sagging of AB Cable 3x120sqmm at different locations of T/F as per site requirement.
Laying, Sagging and Re-Sagging of Weasel Conductor as per site requirement.
Providing and Fixing of J HOOK FOR CABLE HANGING AS PER RESPO.
Providing and Fixing of Clamp with Nut Bolt and Washer with complete work in all respect.
Providing and Fixing of Clamp for 3Phase Distribution Box as per site requirement.
Providing and Fixing of Pad Lock for 3Phase Distribution Box as per site requirement.
Providing and Fixing of Clamp of LT (T-off) with nut & bolts as per site requirement.
Providing, Installation and Commissioning of LT ACB 400Amp. As per GTP approved of PVVNL
Fabrication of Plinth/Chair for 250KVA T/F as per site requirement.
Fabrication of Wiremes Fencing for 250KVA T/F as per site requirement.
Chemical Earthing of BODY AND NEUTRAL OF DISTRIBUTION T/F : Providing of earth elctrode strip in pipe terminal type chemical earthing proper hot deep galvanization dia 50 mm length 3 mtr down conductor size - 32mm x 6mm terminal connection hole dia 8mm The cavity between the strip & pipes is filled with condutive mixture - for hermetically filling inside the cavity i.e. between secondary conductor & primary conductor, crystline compound is to be injected in the electrode assembly. It is a combination of high conductivity metal alloys, copper & aluminum power, conductive carbon / cement and bonding material etc the electrode should be sealed from both the ends. The outer pipe of the elctrode should be zinc coated the characteristics of this compound is highly cnductive, non magnetic & non corrosive in G.I. Including providing of Pgs backfill compound each elctrode should be supplied with bags of 25 kg x 2 bfc compound (ground resistance enhancement powder 50 kgs each CPRI tested to connect the above chemical earthing with the GI strip of size 32 mm x 6 mm suitable for distribution transformer.
Provision of New 250 KVA T/f NEAR D-12, SEC-15 under Substation SECTOR-16 Noida under EUDSD-XI, Noida
Safe carriage of following stock material, from any of the Store Center of PVVNL to work site including Loading from Store and safe unloading at site for Item No. 39 to 50
8.5 Mtr Long PCC Pole
MS Channel (Dropper) 100x50x2028 mm
ACSR Weasle Conductor
Cable LT ABC 3x120+1x95+1x16 Sqmm
MS Top Channel (125x65x2240 mm)
11 KV Disc Insulator T&C type 45 KN
11 KV Disc Fitting
MS Chanel 125x65x1300 mm ( T-Off)
11 KV Poly Pin Insulator
11/0.4 KV T/f 250 KVA
11 KV Fuse Set
LT PVC Cable Al 1x400 Sqmm
Errection of above Following material and Supply and errection of the DE-CENTRALISED material for completing the works as per RESPO.
The excavation of foundation pit in mix soil/normal soil/soft soil & hard rock as per site condition and its back filling and leveling etc. The size of the pit will be (750x450)mm and having depth of 1/6th of the full length of the support. Erection of support, complete with providing & fixing of all G.I.Clamps size of 75x10mm, 65x8mm, G.I.Nut bolt & washer, P.G.Clamp, Stone Pad, Al. Binding wire, 'E' bracket 75x10mm, and other accessories as per drawing. The work includes carriage and handling of supports from sectional store to pit site as well as any fabrication work if required & fixing of cross bracing sets 4.3mtr long, from G.I.Angle 65x65x6mm. The work includes cutting holes and providing G.I.Bolt of 16x40mm size, in the middle of the cross bracing with 01No. spring washer of proper size as per drawing/ as per schedule. Double Pole Structures (a) PCC POLE 8.5MTR
Grouting of supports in CC 1:3:6 (Cement, sand & 20mm stone grift). Grouting will be done in the block of size (450x450)mm x1/6th of full length of the support, upto ground level, 300mm plinth above the ground level with C.C. 1:3:6 (Cement, Course sand and Stone grift) with muffing as per RESPO. Work includes back filling and proper ramming. Single Pole and Double Pole (a) PCC POLE 8.5MTR
FIXING OF MS CHANNEL (DROPPER) 100X50X2028 COMPLETE WORK IN ALL RESPECT.
FIXING OF MS TOP CHANNEL COMPLETE WORK IN ALL RESPECT.
FIXING OF DISC INSULATOR WITH FITTINGS AS PER SITE REQUIREMENT.
FIXING OF T-OFF CHANNEL AS PER SITE REQUIREMENT.
FIXING OF PIN INSULATOR WITH PIN AS PER SITE REQUIREMENT.
FIXING OF 11KV FUSE SET AS PER SITE REQUIREMENT.
CONNECTING OF LT PVC CABLE ALU. 1X400SQMM AS PER SITE REQUIREMENT.
Installation and Commissioning of 11/0.4 KV, 250 KVA T/F Mounted on Plinth as per site requirement and providing & fixing of Lugs & copper L-piece (04 No.) of size 400x50x6mm and making of L.T.Connections with complete work in all respects.
Laying, Sagging and Re-Sagging of AB Cable 3x120sqmm at different locations of T/F as per site requirement.
Laying, Sagging and Re-Sagging of Weasel Conductor as per site requirement.
Providing and Fixing of J HOOK FOR CABLE HANGING AS PER RESPO.
Providing and Fixing of Clamp with Nut Bolt and Washer with complete work in all respect.
Providing and Fixing of Clamp for 3Phase Distribution Box as per site requirement.
Providing and Fixing of Pad Lock for 3Phase Distribution Box as per site requirement.
Providing and Fixing of Clamp of LT (T-off) with nut & bolts as per site requirement.
Providing, Installation and Commissioning of LT ACB 400Amp. As per GTP approved of PVVNL
Fabrication of Plinth/Chair for 250KVA T/F as per site requirement.
Fabrication of Wiremes Fencing for 250KVA T/F as per site requirement.
Chemical Earthing of BODY AND NEUTRAL OF DISTRIBUTION T/F : Providing of earth elctrode strip in pipe terminal type chemical earthing proper hot deep galvanization dia 50 mm length 3 mtr down conductor size - 32mm x 6mm terminal connection hole dia 8mm The cavity between the strip & pipes is filled with condutive mixture - for hermetically filling inside the cavity i.e. between secondary conductor & primary conductor, crystline compound is to be injected in the electrode assembly. It is a combination of high conductivity metal alloys, copper & aluminum power, conductive carbon / cement and bonding material etc the electrode should be sealed from both the ends. The outer pipe of the elctrode should be zinc coated the characteristics of this compound is highly cnductive, non magnetic & non corrosive in G.I. Including providing of Pgs backfill compound each elctrode should be supplied with bags of 25 kg x 2 bfc compound (ground resistance enhancement powder 50 kgs each CPRI tested to connect the above chemical earthing with the GI strip of size 32 mm x 6 mm suitable for distribution transformer.
New 250 KVA T/f Near SBI, Sector-2, Under 33/11 KV S/s, Sector-16, Noida under EUDSD-XI, Noida
Safe carriage of following stock material, from any of the Store Center of PVVNL to work site including Loading from Store and safe unloading at site for Item No. 75 to 86
8.5 Mtr Long PCC Pole
MS Channel (Dropper) 100x50x2028 mm
ACSR Weasle Conductor
Cable LT ABC 3x120+1x95+1x16 Sqmm
MS Top Channel (125x65x2240 mm)
11 KV Disc Insulator T&C type 45 KN
11 KV Disc Fitting
MS Chanel 125x65x1300 mm ( T-Off)
11 KV Poly Pin Insulator
11/0.4 KV T/f 250 KVA
11 KV Fuse Set
LT PVC Cable Al 1x400 Sqmm
Errection of above Following material and Supply and errection of the DE-CENTRALISED material for completing the works as per RESPO.
The excavation of foundation pit in mix soil/normal soil/soft soil & hard rock as per site condition and its back filling and leveling etc. The size of the pit will be (750x450)mm and having depth of 1/6th of the full length of the support. Erection of support, complete with providing & fixing of all G.I.Clamps size of 75x10mm, 65x8mm, G.I.Nut bolt & washer, P.G.Clamp, Stone Pad, Al. Binding wire, 'E' bracket 75x10mm, and other accessories as per drawing. The work includes carriage and handling of supports from sectional store to pit site as well as any fabrication work if required & fixing of cross bracing sets 4.3mtr long, from G.I.Angle 65x65x6mm. The work includes cutting holes and providing G.I.Bolt of 16x40mm size, in the middle of the cross bracing with 01No. spring washer of proper size as per drawing/ as per schedule. Double Pole Structures (a) PCC POLE 8.5MTR
Grouting of supports in CC 1:3:6 (Cement, sand & 20mm stone grift). Grouting will be done in the block of size (450x450)mm x1/6th of full length of the support, upto ground level, 300mm plinth above the ground level with C.C. 1:3:6 (Cement, Course sand and Stone grift) with muffing as per RESPO. Work includes back filling and proper ramming. Single Pole and Double Pole (a) PCC POLE 8.5MTR
FIXING OF MS CHANNEL (DROPPER) 100X50X2028 COMPLETE WORK IN ALL RESPECT.
FIXING OF MS TOP CHANNEL COMPLETE WORK IN ALL RESPECT.
FIXING OF DISC INSULATOR WITH FITTINGS AS PER SITE REQUIREMENT.
FIXING OF T-OFF CHANNEL AS PER SITE REQUIREMENT.
FIXING OF PIN INSULATOR WITH PIN AS PER SITE REQUIREMENT.
FIXING OF 11KV FUSE SET AS PER SITE REQUIREMENT.
CONNECTING OF LT PVC CABLE ALU. 1X400SQMM AS PER SITE REQUIREMENT.
Installation and Commissioning of 11/0.4 KV, 250 KVA T/F Mounted on Plinth as per site requirement and providing & fixing of Lugs & copper L-piece (04 No.) of size 400x50x6mm and making of L.T.Connections with complete work in all respects.
Laying, Sagging and Re-Sagging of AB Cable 3x120sqmm at different locations of T/F as per site requirement.
Laying, Sagging and Re-Sagging of Weasel Conductor as per site requirement.
Providing and Fixing of J HOOK FOR CABLE HANGING AS PER RESPO.
Providing and Fixing of Clamp with Nut Bolt and Washer with complete work in all respect.
Providing and Fixing of Clamp for 3Phase Distribution Box as per site requirement.
Providing and Fixing of Pad Lock for 3Phase Distribution Box as per site requirement.
Providing and Fixing of Clamp of LT (T-off) with nut & bolts as per site requirement.
Providing, Installation and Commissioning of LT ACB 400Amp. As per GTP approved of PVVNL
Fabrication of Plinth/Chair for 250KVA T/F as per site requirement.
Fabrication of Wiremes Fencing for 250KVA T/F as per site requirement.
Chemical Earthing of BODY AND NEUTRAL OF DISTRIBUTION T/F : Providing of earth elctrode strip in pipe terminal type chemical earthing proper hot deep galvanization dia 50 mm length 3 mtr down conductor size - 32mm x 6mm terminal connection hole dia 8mm The cavity between the strip & pipes is filled with condutive mixture - for hermetically filling inside the cavity i.e. between secondary conductor & primary conductor, crystline compound is to be injected in the electrode assembly. It is a combination of high conductivity metal alloys, copper & aluminum power, conductive carbon / cement and bonding material etc the electrode should be sealed from both the ends. The outer pipe of the elctrode should be zinc coated the characteristics of this compound is highly cnductive, non magnetic & non corrosive in G.I. Including providing of Pgs backfill compound each elctrode should be supplied with bags of 25 kg x 2 bfc compound (ground resistance enhancement powder 50 kgs each CPRI tested to connect the above chemical earthing with the GI strip of size 32 mm x 6 mm suitable for distribution transformer.
Provision of New 250 KVA T/f Near B-145, Sector-15, Noida, Under 33/11 KV S/s, Sector-16, Noida under EUDSD-XI, Noida
Safe carriage of following stock material, from any of the Store Center of PVVNL to work site including Loading from Store and safe unloading at site for Item No. 111 to 122
8.5 Mtr Long PCC Pole
MS Channel (Dropper) 100x50x2028 mm
ACSR Weasle Conductor
Cable LT ABC 3x120+1x95+1x16 Sqmm
MS Top Channel (125x65x2240 mm)
11 KV Disc Insulator T&C type 45 KN
11 KV Disc Fitting
MS Chanel 125x65x1300 mm ( T-Off)
11 KV Poly Pin Insulator
11/0.4 KV T/f 250 KVA
11 KV Fuse Set
LT PVC Cable Al 1x400 Sqmm
Errection of above Following material and Supply and errection of the DE-CENTRALISED material for completing the works as per RESPO.
The excavation of foundation pit in mix soil/normal soil/soft soil & hard rock as per site condition and its back filling and leveling etc. The size of the pit will be (750x450)mm and having depth of 1/6th of the full length of the support. Erection of support, complete with providing & fixing of all G.I.Clamps size of 75x10mm, 65x8mm, G.I.Nut bolt & washer, P.G.Clamp, Stone Pad, Al. Binding wire, 'E' bracket 75x10mm, and other accessories as per drawing. The work includes carriage and handling of supports from sectional store to pit site as well as any fabrication work if required & fixing of cross bracing sets 4.3mtr long, from G.I.Angle 65x65x6mm. The work includes cutting holes and providing G.I.Bolt of 16x40mm size, in the middle of the cross bracing with 01No. spring washer of proper size as per drawing/ as per schedule. Double Pole Structures (a) PCC POLE 8.5MTR
Grouting of supports in CC 1:3:6 (Cement, sand & 20mm stone grift). Grouting will be done in the block of size (450x450)mm x1/6th of full length of the support, upto ground level, 300mm plinth above the ground level with C.C. 1:3:6 (Cement, Course sand and Stone grift) with muffing as per RESPO. Work includes back filling and proper ramming. Single Pole and Double Pole (a) PCC POLE 8.5MTR
FIXING OF MS CHANNEL (DROPPER) 100X50X2028 COMPLETE WORK IN ALL RESPECT.
FIXING OF MS TOP CHANNEL COMPLETE WORK IN ALL RESPECT.
FIXING OF DISC INSULATOR WITH FITTINGS AS PER SITE REQUIREMENT.
FIXING OF T-OFF CHANNEL AS PER SITE REQUIREMENT.
FIXING OF PIN INSULATOR WITH PIN AS PER SITE REQUIREMENT.
FIXING OF 11KV FUSE SET AS PER SITE REQUIREMENT.
CONNECTING OF LT PVC CABLE ALU. 1X400SQMM AS PER SITE REQUIREMENT.
Installation and Commissioning of 11/0.4 KV, 250 KVA T/F Mounted on Plinth as per site requirement and providing & fixing of Lugs & copper L-piece (04 No.) of size 400x50x6mm and making of L.T.Connections with complete work in all respects.
Laying, Sagging and Re-Sagging of AB Cable 3x120sqmm at different locations of T/F as per site requirement.
Laying, Sagging and Re-Sagging of Weasel Conductor as per site requirement.
Providing and Fixing of J HOOK FOR CABLE HANGING AS PER RESPO.
Providing and Fixing of Clamp with Nut Bolt and Washer with complete work in all respect.
Providing and Fixing of Clamp for 3Phase Distribution Box as per site requirement.
Providing and Fixing of Pad Lock for 3Phase Distribution Box as per site requirement.
Providing and Fixing of Clamp of LT (T-off) with nut & bolts as per site requirement.
Providing, Installation and Commissioning of LT ACB 400Amp. As per GTP approved of PVVNL
Fabrication of Plinth/Chair for 250KVA T/F as per site requirement.
Fabrication of Wiremes Fencing for 250KVA T/F as per site requirement.
Chemical Earthing of BODY AND NEUTRAL OF DISTRIBUTION T/F : Providing of earth elctrode strip in pipe terminal type chemical earthing proper hot deep galvanization dia 50 mm length 3 mtr down conductor size - 32mm x 6mm terminal connection hole dia 8mm The cavity between the strip & pipes is filled with condutive mixture - for hermetically filling inside the cavity i.e. between secondary conductor & primary conductor, crystline compound is to be injected in the electrode assembly. It is a combination of high conductivity metal alloys, copper & aluminum power, conductive carbon / cement and bonding material etc the electrode should be sealed from both the ends. The outer pipe of the elctrode should be zinc coated the characteristics of this compound is highly cnductive, non magnetic & non corrosive in G.I. Including providing of Pgs backfill compound each elctrode should be supplied with bags of 25 kg x 2 bfc compound (ground resistance enhancement powder 50 kgs each CPRI tested to connect the above chemical earthing with the GI strip of size 32 mm x 6 mm suitable for distribution transformer.
Provision of New 250 KVA T/f Near A-20, Sector-16, Noida, Under 33/11 KV S/s, Sector-16, Noida under EUDSD-XI, Noida
Safe carriage of following stock material, from any of the Store Center of PVVNL to work site including Loading from Store and safe unloading at site for Item No. 147 to 158
8.5 Mtr Long PCC Pole
MS Channel (Dropper) 100x50x2028 mm
ACSR Weasle Conductor
Cable LT ABC 3x120+1x95+1x16 Sqmm
MS Top Channel (125x65x2240 mm)
11 KV Disc Insulator T&C type 45 KN
11 KV Disc Fitting
MS Chanel 125x65x1300 mm ( T-Off)
11 KV Poly Pin Insulator
11/0.4 KV T/f 250 KVA
11 KV Fuse Set
LT PVC Cable Al 1x400 Sqmm
Errection of above Following material and Supply and errection of the DE-CENTRALISED material for completing the works as per RESPO.
The excavation of foundation pit in mix soil/normal soil/soft soil & hard rock as per site condition and its back filling and leveling etc. The size of the pit will be (750x450)mm and having depth of 1/6th of the full length of the support. Erection of support, complete with providing & fixing of all G.I.Clamps size of 75x10mm, 65x8mm, G.I.Nut bolt & washer, P.G.Clamp, Stone Pad, Al. Binding wire, 'E' bracket 75x10mm, and other accessories as per drawing. The work includes carriage and handling of supports from sectional store to pit site as well as any fabrication work if required & fixing of cross bracing sets 4.3mtr long, from G.I.Angle 65x65x6mm. The work includes cutting holes and providing G.I.Bolt of 16x40mm size, in the middle of the cross bracing with 01No. spring washer of proper size as per drawing/ as per schedule. Double Pole Structures (a) PCC POLE 8.5MTR
Grouting of supports in CC 1:3:6 (Cement, sand & 20mm stone grift). Grouting will be done in the block of size (450x450)mm x1/6th of full length of the support, upto ground level, 300mm plinth above the ground level with C.C. 1:3:6 (Cement, Course sand and Stone grift) with muffing as per RESPO. Work includes back filling and proper ramming. Single Pole and Double Pole (a) PCC POLE 8.5MTR
FIXING OF MS CHANNEL (DROPPER) 100X50X2028 COMPLETE WORK IN ALL RESPECT.
FIXING OF MS TOP CHANNEL COMPLETE WORK IN ALL RESPECT.
FIXING OF DISC INSULATOR WITH FITTINGS AS PER SITE REQUIREMENT.
FIXING OF T-OFF CHANNEL AS PER SITE REQUIREMENT.
FIXING OF PIN INSULATOR WITH PIN AS PER SITE REQUIREMENT.
FIXING OF 11KV FUSE SET AS PER SITE REQUIREMENT.
CONNECTING OF LT PVC CABLE ALU. 1X400SQMM AS PER SITE REQUIREMENT.
Installation and Commissioning of 11/0.4 KV, 250 KVA T/F Mounted on Plinth as per site requirement and providing & fixing of Lugs & copper L-piece (04 No.) of size 400x50x6mm and making of L.T.Connections with complete work in all respects.
Laying, Sagging and Re-Sagging of AB Cable 3x120sqmm at different locations of T/F as per site requirement.
Laying, Sagging and Re-Sagging of Weasel Conductor as per site requirement.
Providing and Fixing of J HOOK FOR CABLE HANGING AS PER RESPO.
Providing and Fixing of Clamp with Nut Bolt and Washer with complete work in all respect.
Providing and Fixing of Clamp for 3Phase Distribution Box as per site requirement.
Providing and Fixing of Pad Lock for 3Phase Distribution Box as per site requirement.
Providing and Fixing of Clamp of LT (T-off) with nut & bolts as per site requirement.
Providing, Installation and Commissioning of LT ACB 400Amp. As per GTP approved of PVVNL
Fabrication of Plinth/Chair for 250KVA T/F as per site requirement.
Fabrication of Wiremes Fencing for 250KVA T/F as per site requirement.
Chemical Earthing of BODY AND NEUTRAL OF DISTRIBUTION T/F : Providing of earth elctrode strip in pipe terminal type chemical earthing proper hot deep galvanization dia 50 mm length 3 mtr down conductor size - 32mm x 6mm terminal connection hole dia 8mm The cavity between the strip & pipes is filled with condutive mixture - for hermetically filling inside the cavity i.e. between secondary conductor & primary conductor, crystline compound is to be injected in the electrode assembly. It is a combination of high conductivity metal alloys, copper & aluminum power, conductive carbon / cement and bonding material etc the electrode should be sealed from both the ends. The outer pipe of the elctrode should be zinc coated the characteristics of this compound is highly cnductive, non magnetic & non corrosive in G.I. Including providing of Pgs backfill compound each elctrode should be supplied with bags of 25 kg x 2 bfc compound (ground resistance enhancement powder 50 kgs each CPRI tested to connect the above chemical earthing with the GI strip of size 32 mm x 6 mm suitable for distribution transformer.
Provision of New 250 KVA T/f Near A-1D, Sector-16, Noida Under 33/11 KV S/s, Sector-16, Noida under EUDSD-XI, Noida
Safe carriage of following stock material, from any of the Store Center of PVVNL to work site including Loading from Store and safe unloading at site for Item No. 183 to 18
8.5 Mtr Long PCC Pole
MS Channel (Dropper) 100x50x2028 mm
ACSR Weasle Conductor
Cable LT ABC 3x120+1x95+1x16 Sqmm
MS Top Channel (125x65x2240 mm)
11 KV Disc Insulator T&C type 45 KN
11 KV Disc Fitting
MS Chanel 125x65x1300 mm ( T-Off)
11 KV Poly Pin Insulator
11/0.4 KV T/f 250 KVA
11 KV Fuse Set
LT PVC Cable Al 1x400 Sqmm
Errection of above Following material and Supply and errection of the DE-CENTRALISED material for completing the works as per RESPO.
The excavation of foundation pit in mix soil/normal soil/soft soil & hard rock as per site condition and its back filling and leveling etc. The size of the pit will be (750x450)mm and having depth of 1/6th of the full length of the support. Erection of support, complete with providing & fixing of all G.I.Clamps size of 75x10mm, 65x8mm, G.I.Nut bolt & washer, P.G.Clamp, Stone Pad, Al. Binding wire, 'E' bracket 75x10mm, and other accessories as per drawing. The work includes carriage and handling of supports from sectional store to pit site as well as any fabrication work if required & fixing of cross bracing sets 4.3mtr long, from G.I.Angle 65x65x6mm. The work includes cutting holes and providing G.I.Bolt of 16x40mm size, in the middle of the cross bracing with 01No. spring washer of proper size as per drawing/ as per schedule. Double Pole Structures (a) PCC POLE 8.5MTR
Grouting of supports in CC 1:3:6 (Cement, sand & 20mm stone grift). Grouting will be done in the block of size (450x450)mm x1/6th of full length of the support, upto ground level, 300mm plinth above the ground level with C.C. 1:3:6 (Cement, Course sand and Stone grift) with muffing as per RESPO. Work includes back filling and proper ramming. Single Pole and Double Pole (a) PCC POLE 8.5MTR
FIXING OF MS CHANNEL (DROPPER) 100X50X2028 COMPLETE WORK IN ALL RESPECT.
FIXING OF MS TOP CHANNEL COMPLETE WORK IN ALL RESPECT.
FIXING OF DISC INSULATOR WITH FITTINGS AS PER SITE REQUIREMENT.
FIXING OF T-OFF CHANNEL AS PER SITE REQUIREMENT.
FIXING OF PIN INSULATOR WITH PIN AS PER SITE REQUIREMENT.
FIXING OF 11KV FUSE SET AS PER SITE REQUIREMENT.
CONNECTING OF LT PVC CABLE ALU. 1X400SQMM AS PER SITE REQUIREMENT.
Installation and Commissioning of 11/0.4 KV, 250 KVA T/F Mounted on Plinth as per site requirement and providing & fixing of Lugs & copper L-piece (04 No.) of size 400x50x6mm and making of L.T.Connections with complete work in all respects.
Laying, Sagging and Re-Sagging of AB Cable 3x120sqmm at different locations of T/F as per site requirement.
Laying, Sagging and Re-Sagging of Weasel Conductor as per site requirement.
Providing and Fixing of J HOOK FOR CABLE HANGING AS PER RESPO.
Providing and Fixing of Clamp with Nut Bolt and Washer with complete work in all respect.
Providing and Fixing of Clamp for 3Phase Distribution Box as per site requirement.
Providing and Fixing of Pad Lock for 3Phase Distribution Box as per site requirement.
Providing and Fixing of Clamp of LT (T-off) with nut & bolts as per site requirement.
Providing, Installation and Commissioning of LT ACB 400Amp. As per GTP approved of PVVNL
Fabrication of Plinth/Chair for 250KVA T/F as per site requirement.
Fabrication of Wiremes Fencing for 250KVA T/F as per site requirement.
Chemical Earthing of BODY AND NEUTRAL OF DISTRIBUTION T/F : Providing of earth elctrode strip in pipe terminal type chemical earthing proper hot deep galvanization dia 50 mm length 3 mtr down conductor size - 32mm x 6mm terminal connection hole dia 8mm The cavity between the strip & pipes is filled with condutive mixture - for hermetically filling inside the cavity i.e. between secondary conductor & primary conductor, crystline compound is to be injected in the electrode assembly. It is a combination of high conductivity metal alloys, copper & aluminum power, conductive carbon / cement and bonding material etc the electrode should be sealed from both the ends. The outer pipe of the elctrode should be zinc coated the characteristics of this compound is highly cnductive, non magnetic & non corrosive in G.I. Including providing of Pgs backfill compound each elctrode should be supplied with bags of 25 kg x 2 bfc compound (ground resistance enhancement powder 50 kgs each CPRI tested to connect the above chemical earthing with the GI strip of size 32 mm x 6 mm suitable for distribution transformer.
Kunal Electricals (BID ID -4745702)
M/s S S CONTRACTOR (BID ID -4747389)
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .