EXECUTIVE ENGINEER (ELECT.)
BSNL ELECTRICAL DIVISION-II, EASTERN COURT, JANPATH, NEW DELHI-110001
Servicing and repairing of inverter type Cassette Split AC units, Provision of proper drainage system, MS platforms for AC outdoor units and miscellaneous work in Sanchar Bhawan, New Delhi. Ch. to ARMO of AC works
2026_BSNL_294907_1
20/NIT/E-TENDER/2026-27/ED-II
Open Tender
Electrical Works
Percentage
270 days
SANCHAR BHAWAN
Please refer Tender documents.
4 documents required · 4 mandatory
₹590
A.O. (Cash) O/o CGM BSNL, NTR, New Delhi
₹9,492
16 Oct 2026
16 Oct 2026
28 Oct 2026
16 Oct 2026
27 Oct 2026
16 Oct 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Replacement of faulty electrically operated solenoid valve of existing 1.5/2.0 TR split AC units including Supply & fixing of new one to work of AC units on cooling as well as heating cycle etc. complete as reqd. | 1 | No. | 4,349 | ₹4,349 |
| 2 | Servicing of Inverter type cassette AC Units including washing & cleaning of filters, complete unit i.e. evaporator unit, condenser unit i/c oiling, greasing of motors, testing, commissioning etc. complete as reqd. | 2 | Job | 1,200 | ₹2,400 |
| 3 | Repairing & Testing of 1.5 TR Capacity cassette type inverter AC , flushing the system, pressure testing with Nitrogen gas holding the pressure for 24 hours, vaccumising, removal of leakage in Indoor unit & out door unit including supply & charging of refrigerant gas (R-410) and oiling, greasing of motors, testing commissioning etc. complete as reqd. | 5 | Job | 6,354 | ₹31,770 |
| 4 | Repairing & Testing of 1.5 TR Capacity Split type inverter AC , flushing the system, pressure testing with Nitrogen gas holding the pressure for 24 hours, vaccumising, removal of leakage in Indoor unit & out door unit including supply & charging of refrigerant gas (R-410/R-32) and oiling, greasing of motors, testing commissioning etc. complete as reqd. | 5 | Job | 4,150 | ₹20,750 |
| 5 | Supply , Installation , Testing & Commissioning of Hitachi scroll Compressor 1.8 Ton cassette AC in the existing i/c making brazing , leakage testing etc. comp as reqd. (M/s Hitachi/ LG/ Voltas) | 1 | No. | 18,500 | ₹18,500 |
| 6S/Fixing of following size 1.1 KV Grade PVC insulated copper conductor flexible cable in the existing M.S. Tray/Surface/Wall including S/F saddles, screws, thimbles i/c making connections, testing etc. complete as required. | |||||
| 6.1 | 4 Core 2.5 Sqmm | 25 | Meter | 261 | ₹6,525 |
| 6.2 | 3 Core 2.5 Sqmm | 26 | Meter | 185 | ₹4,810 |
| 7 | Providing and fixing on new PCB card for cassette AC units outdoor units i/c dismantling of old PCB and ITC of new PCB card i/c connection etc. complete as reqd. | 1 | Job | 16,350 | ₹16,350 |
| 8Repairing of faulty 1.5 TR Cassette/split type AC with repairing of following item i/c dismantling, repairing and refixing, testing commissioning etc. complete as reqd. | |||||
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.98 MB
BOQ_343705.xls
BOQ • 0.42 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .