Shri Vinay Kumar, IDSE, SE (SAG) CWE
HQ Commander Works, Engineer CWE (Army) Mumbai, 24 Assaye Building Colaba, Mumbai-05
REPAIR/ MAINT OF TRANSFORMERS AND EARTHING OF VARIOUS SUBSTATIONS INCLUDING REPAIR OF TRANSFORMER FOUNDATION FENCING ETC UNDER GE (WEST) COLABA, MUMBAI
2026_MES_798291_1
85378/W/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (WEST) COLABA
All as per NIT and tender documents
8 documents required · 8 mandatory
₹500
Yes
GE (west) Colaba
₹89,800
Yes
12 Nov 2026
12 Nov 2026
9 Dec 2026
12 Nov 2026
7 Dec 2026
28 Nov 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | M&L for Dy hydration/filtration of Transformer oil including testing of dielectric strength of transformer oil of indoor type transformer, 11KV/433 volt, filtration of transformer oil by passing through filtration plant to remove moisture, impurities and improving di-electic strength to above 50 KV for 1 minute including new transformer oil for toping up and testing after filtration complete as specified and directed.
(Note: Transformer oil will be measured and paid seperately.) | 8,500 | Ltr | - | - |
| 2 | M&L for Removing old burnt Transformer oil and Supply and topping of transformer oil with not less than 50KV di-electric strength complete all as specified and directed.
Make: Power /Asian/Savita/Electric. | 1,000 | Ltr | - | - |
| 3 | Supply and fixing of hydrogenated nitrile transformer oil seal, with maximum di electric strength duely tightened with bushings complete to avoid leakage from transformer bushings of various transformer installed at various locations under Colaba area all as specified and directed . | 12 | Each Job | - | - |
| 4 | M & L for spray painting to indoor/outdoor type, step up/step down transformer installed at different location of Colaba area after scraping thoroughly the existing corroded paint/rust, filing of cavaties and applying two coats of heat resistant paint of approved quality of required colour and writing the details such as SM/MES No. etc.of capacity 100KVA to 200 KVA and providing metal board plate with details such as SM/MES No. etc.of capacity and oil KV/ Min rating all as per specified and directed by Engr - in - Charge . | 2 | Each Job | - | - |
| 5 | M & L for spray painting to indoor/outdoor type, step up/step down transformer installed at different location of Colaba area after scraping throughly the existing corroded paint/rust, filing of cavaties and applying two coats of heat resistant paint of approved quality of required colour and writing the details such as SM/MES No. etc.of capacity 250 KVA to 400 KVA and providing metal board plate with details such as SM/MES No. etc.of capacity and oil KV/ Min rating all as per specified and directed by Engr - in - Charge . | 5 | Each Job | - | - |
| 6 | M & L for spray painting to indoor/outdoor type, step up/step down transformer installed at different location of Colaba area after scraping throughly the existing corroded paint/rust, filing of cavaties and applying two coats of heat resistant paint of approved quality of required colour and writing the details such as SM/MES No. etc.of capacity 500KVA to 800 KVA and providing metal board plate with details such as SM/MES No. etc.of capacity and oil KV/ Min rating all as per specified and directed by Engr - in - Charge . | 4 | Each Job | - | - |
| 7 | Dismantling of Damaged Breather and Supply and fixing in repair of breather with 500 Grams silica gel of indoor type transformer 200KVA/300KVA/400/500 KVA, all as specified and directed by Engineer-in-Charge. | 19 | Each Job | - | - |
| 8 | Dismantling of Damaged thermometer and Supply and fixing in repair of thermometer(oil temperature gauge) for indoor type transformer, all as specified and directed by Engineer -in -Charge. | 5 | Each | - | - |
| 9 | Material and labour for Servicing/Repairing of Transformer by disconnecting of LT and HT cable carefully from Transformer and draining out transformer oil, dismantling transformer top cover and dismantling of 4Nos LT bushing and 3Nos of HT bushing including necessary tools and plant for removal of sediments, carbon deposits at bottom of transformer tank, on core, on winding etc cleaning with new transformer oil including cleaning of oil tank and attending leakage problem with oil seal and all gaskets and re assembling complete parts of Transformer capacity 500KVA to 800KVA ,11KV/433Volt all as specified and directed.
(Note : New Transformer oil and spare parts will be measured and paid separatley excluding oil seal) | 6 | Each Job | - | - |
| 10 | Material and labour for Servicing/Repairing of Transformer by disconnecting of LT and HT cable carefully from Transformer and draining out transformer oil, dismantling transformer top cover and dismantling of 4Nos LT bushing and 3Nos of HT bushing including necessary tools and plant for removal of sediments, carbon deposits at bottom of transformer tank, on core, on winding etc cleaning with new transformer oil including cleaning of oil tank and attending leakage problem with oil seal and all gaskets and re assembling complete parts of Transformer capacity 250KVA to 400KVA , 11KV/433Volt all as specified and directed.
(Note : New Transformer oil and spare parts will be measured and paid separatley excluding oil seal) | 9 | Each Job | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.33 MB
Tenderdocumens85378.pdf
Tender Documents • 1.09 MB
BOQ_895537.xls
BOQ • 0.78 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .