Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.8 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹11.3 L+₹1.4 L (13.6%)Rejected-AOC VILL PO BUNGWAN KALAN TALBEHAT LALITPUR UTTAR PRADESH 284136 | TALBEHAT | LALITPUR | UTTAR PRADESH | 284136 | L2 | Rejected-AOC Rejected | |
| 3 | L3₹11.6 L+₹1.6 L (16.0%)Rejected-AOC VILLAGE TAPARIYAN BABINA CANTT BABINA JHANSI UP 284401 | BABINA | JHANSI | UP | 284401 | L3 | Rejected-AOC Rejected | |
| 4 | L4₹12.0 L+₹2.0 L (20.0%)Rejected-AOC CIVIL LINE MATATILA ROAD TALBEHAT DISTT LALITPUR U P | TALBEHAT | LALITPUR | U P | L4 | Rejected-AOC Rejected |
Tender Value
Refer Docs
EMD Value
₹29,100
Closing Date
1 Oct 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE JHANSI
HQ CWE JHANSI
SPECIAL REPAIRS TO BLDG NO. T-41/01 TO T-41/08 (TOTAL 08 QTR) IN ZONE-11 AT MIL STN TALBEHAT UNDER AGE (I) TALBEHAT
2020_MES_372589_1
CWE/JHA/TBT/43 OF 2020-21
Open Tender
Civil Works
Item Rate
180 days
TALBEHAT
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
AGE (I) TALBEHAT
₹29,100
Yes
8 Dec 2020
28 Aug 2020
7 Oct 2020
28 Aug 2020
1 Oct 2020
19 Sept 2020
60 days
Amount
Taking down cement plaster including existing tarfelt roof treatment from roofs/vertical surfaces, complete all as specified and directed. Note: All debris obtained from taking down shall be removed 1.5 km to 2 km complete all as specified and as directed.
M & L for Cutting out cracks to V-section in existing roofs or terracing, cleaning out, wetting, grouting with cement and sand slurry 1:3 complete all as specified and directed.
M & L for PCC 1:2:4 (B-0) for roof padding for proper slope complete all as specified and directed.
M & L for PCC 1:2:4 type B-0 (using 12.5 mm graded crushed stone aggregate) as in cills, coping, benching on chajjas, kerbs, mud stops, bed blocks and the like including weathering, slightly rounded or chamfered angles and throating as directed with and including necessary form work complete all as specified and directed.
M &L for 15 mm thick rendering on fair faces of brick/concrete surfaces in CM 1:4 mixed with liquid water proofing compound @ 0.25% by the weight of cement or as per manufacturer's instructions complete all as specified and directed. Note: - Supply of Liquid water proofing compound shall be measured and paid separately.
Supply only liquid water proofing compound complete all as specified and directed.
M&L for providing roof treatment complete all as specified and directed as described in the following process: - (a) The roof surface shall be cleaned thoroughly and applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.20 Kg per sqm over bituminous primer @ 0.5Kg/Sqm (b) Applying APP based polymeric membrane weight not less than 3Kg/Sqm and minimum 3mm thick reinforced with polyester non woven fabric (wt not less than 150gram/sqm) laid on primed surface by torch application as per the manufacturer's instructions with side over lap of 75mm and end over lap of 100mm. (c ) M&L for a coat of hot blown bitumen of grade 85/25 @ 1.20Kg/Sqm shall be applied over water proofing membrane finally it shall be finished with a coat of bituminous aluminium paint @ 0.20Kg/Sqm Note: The work of water proofing treatment shall be got executed through manufacturer or authorised applicator of the manufacturer only.
Taking down cement plaster hacking for keys racking out joints of old brick work or brick work or stone work including ceiling built in cement mortar and scrubing down with water etc to receive the top layer complete all as specified and directed.
M&L for 15mm thick external plastering in cm (1:4) on fair faces of brick work or concrete surface including finishing the surfaces fair and even with using integral water proofing compound (WPC) complete all as specified & as directed. [Note: Water proofing compound will be measured and apid separately here-in-before]
M & L for rendering 10mm thick cement plaster in CM(1:6) on fair faces of brick work or concrete surface finished even and smooth without using extra cement or lime complete all as specified and directed.
Material and labour for 5mm thick in CM 1:3 rendering on fair faces of brick or concrete surfaces on ceiling finished even and smooth without using extra cement complete all as specified and directed.
Material and labour for preparation of newly plastered surfaces and applying 2 coats of cement base paint in any colour over a coat of primer on new or previously untreated surfaces of wall complete all as specified and directed.
M&L for applying 3 mm thickness acrylic wall putty including preparation of surface prior to base coat over finishing coat using emery sand paper to achieve a smooth and even surface complete all as specified and directed.
M & L for applying 2 coats of oil bound distemper over a coat of primer on new or previously untreated surfaces of wall including preparation of surfaces complete all as specified and directed.
Material and labour for preparation of newly plastered surfaces and applying three coats of white wash on ceilings complete all as specified and directed.
M&L for preparation of old surfaces of wall by complete removal of existing treatment and applying 2 coats of oil bound distemper over a coat of primer complete all as specified and directed.
M&L for preparation of old surfaces of wall by complete removal of existing treatment and applying 2 coats of cement base paint in any colour over a coat of primer complete all as specified and directed.
M&L preparation of old ceiling surfaces by complete removal of existing treatment and applying three coats of white wash complete all as specified and directed.
Demolition of concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed
Demlition of concrete etc in ground floors and paving n.exc 15cm thickness (below or above ground level) un-reinforced concrete & removal of rubbish beyond defence land complete all as specified and directed.
M & L for 15mm thick plastering in cement mortar 1:3 on the faces of brick work or concrete surfaces without using extra cement and mixed with liquid water proofing compound in vertical and bottom surface complete all as specified and directed. Note:- Liquid water proofing solution should be provided in 150ml in 50Kg cement by weight and the water proofing solution supplied and paid separate items complete all as specified and directed.
M&L for PCC 1:2:4 type Bo using 12.5mm graded stone aggregate mixed with water proofing compound as per manufactures instruction on bottom up sunken portion with proper slope towards spout/spouts complete all as specified and directed. Note:- Liquid water proofing solution should be provided by 150ml in 50Kg cement by weight and the water proofing solution supplied and paid separate items complete all as specified and as directed
M&L of water proofing treatment to sunken floor complete all as specified and as directed with following course of description below: (a) Applying one layer of cement slurry @ 0.688kg/Sqm mixed with acrylic based polymer modified chemical composite compound coating @0.253Kg/Sqm of make of approved in manufactures instruction and the allowed as cure for 4 Hours. (b) Second layer of cement slurry @0.240Kg/Sqm mixed with acrylic based polyer modified chemical composite compound coating @0.120Kg/Sqm and be allowed to a cure for 4 Hours. to following with max curing and testing for leak proof by ponding for 72 hours.
M&L for PCC 1:5:10 type E-2 as in foundation, sub base of floor and mass concrete using 40 mm graded stone aggregate complete all as specified and directed.
M&L for 50mm dia GI pipe as in spout to drain out if any leakage occurs in the sunken portion complete all as specified and directed.
M&L for first or premium or standard quality Non-Skid ceramic floor tiles coloured 6-7 mm thick (square / rectangular) area of each tile exc 0.06 sqm but n. exc 0.11 sqm thick laid over screed bed 15 thick in CM 1:6 including 25mm thick cement concrete 1:2:4 type B-0 (12.5mm graded aggregate) set and jointed in neat cement slurry and pointed in white cement mixed with coloured pigment to match complete all as specified and directed.
Dismantling of cast iron or reinforced concrete drain pipe upto 100 mm bore, jointed in cement mortar and taking out of trenches and wall if required complete all as specified and directed.
S&F in repair 100mm dia Sand Cast iron soil waste and vent pipes, in any length with or without ears, with cement joints and fixed to wall complete all as specified and directed.
S&F in repair 100mm dia Branch piece, single (equal or unequal) , ordinary or inverted, spigot or socket type or with parallel branches complete all as specified and directed.
S&F in repair 75mm dia Sand Cast iron soil waste and vent pipes, in any length with or without ears, with cement joints, fixed to wall complete all as specified and directed.
S&F in repair 100mm dia Cast iron bend diminshing pieces or tapers complete all as specified and directed.
S&F in repair 75mm dia Cast iron bend diminshing pieces or tapers complete all as specified and directed.
S&F in repair 100mm dia Cast iron bend with oval access door diminshing pieces or tapers complete all as specified and directed.
S&F in repair vitreous china squatting pan Orissa pattern size 580 x 440mm with integral foot rest including 'P' or 'S' complete all as specified and directed. Make:-johnson peddar,Hindware (1 st quality) ,Parryware (superfine)
Taking up or down 15 mm dia steel tubing and connection including removal complete all as specified and directed.
Taking up or down 20 mm dia steel tubing and connection including removal complete all as specified and directed.
S&F 15mm bore steel tubes medium grade galvanized with all fitting and fixed complete to walls and ceiling or laid in floor complete all as specified and directed.
Re- fixing of serviceable galvanised steel (GI) tubing of 15 mm bore as obtained from item No 35 here in before with all new fitting to wall , ceiling or laid in floors including necessary cleaning complete all as specified and directed.
S&F 20mm bore steel tubes medium grade galvanized with all fitting and fixed complete to walls and ceiling or laid in floor complete all as specified and directed.
Re- fixing of serviceable galvanised steel (GI) tubing of 15 mm bore as obtained from item No 36 here in before with all new fitting to wall , ceiling or laid in floors including necessary cleaning complete all as specified and directed.
Disconnecting existing water tanks exc 250ltr and n.exc 500ltr, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (Cleaning repairing, etc. measured separately) complete all as specified and directed.
M&L for Cleaning and removing all scale and dirt, etc, from water tanks exc 250ltr and n.exc 500ltr and from mouths of circulating pipes, etc complete all as specified and directed.
Demolition of brickwork built in cement mortar with all quoins, pillars etc complete all as specified and directed.
M&L brick work with fly ash bricks, straight or curved on plan exc 6m mean radius built in cm (1:6) complete all as specified and directed.
M&L for 75 mm thick plain cement concrete (1:3:6) type C-2, (using 40mm graded stone aggregate ) as in plinth protection finishing concrete surface even and smooth without using extra cement including necessary mastic filling of joints complete all as specified and directed.
Taking down chowkhat or frames with shutter (without taking of shutters from the frame) exc 1.5 sqm but not exc 4 Sqm complete all as specified and directed.
Taking down chowkhat or frames with shutter (without taking of shutters from the frame) n. exc 1.5 sqm each complete all as specified and directed.
S&F 2nd class Hard wood Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, complete all as specified and directed.
Supply and fix for 35mm thick 2nd class hardwood Plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats complete all as specified and directed.
M&L for 35 mm thick of 2nd class Hard Wood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, hamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified and directed.
Cutting holes in brick masonry walls builts in cement mortar for inserting hold fasts, depth of embeded portion of hold fast exc 10cm and n exc 20cm and making good in CM 1:3 including finishing to wall complete to match with the adjoining existing surface complete all as specified & as directed. .
S&F MS hold fast and other small articles made out of mild steel flat iron complete all as specified & as directed.
M&L for plain cement concrete (1:3:6) Type C-1 (using 20mm graded stone aggregate) as in hold fast block and base for PVC tank etc including necessary form work complete all as specified and directed.
S&F stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks, or galvanised wire staple, complete all as specified and directed
S&F for steel window with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed
Ditto as above, but without glazing bars complete all as specified and directed
S&F Steel ventilator with top hung shutters including hinges, steel peg stay, complete as specified and as directed.
S&F 3mm thick ordinary quality glass and glazing with oil putty in square n.exc 0.5Sqm in each pane complete all as specified and directed.
S&F in repair 3mm thick figured sheet glass, pin head types and glazing with oil putty in squares n exc. 0.50 Sqm each pane complete with oil putty complete all as specified and directed
S&F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 complete all as specified and directed.
S&F 125mm size aluminium alloy handles, febricated type extruded section, ISI marked complete all as specified and directed.
S&F for aluminium anodized barrel tower bolts 200 mm of extruded section and fixed complete all as specified and directed.
S&F butt hinges 100mm medium weight cold rolled mild steel complete all as specified and directed.
S&F 250mm long aluminium alloy anodised sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section complete all as specified and directed.
M & L for preparation of new steel or iron surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed.
M & L for preparation of new wooden surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer complete all as specified and directed.
M&L for preparation of old painted steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for preparation of old painted wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying one coat of Synthetic enamel paint complete all as specified and directed.
Taking down carefully copper/Aluminium point wiring (light/fan/socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc, removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good distrubed surfaces of wall, floors etc complete all as specified and directed.
Taking down Distribution Boards alongwith MCB's including removing the same from site and making good to the disturbed surface complete all as specified and directed.
Taking down existing sub main wiring of any type and description including removal of teak wood batten/pipe etc complete all as specified and directed.
M&L for point wiring concealed type with 1.5sq mm FRLSH PVC insulated unsheathed single core multithreaded copper conductor cable 1100 volts grade of three run ( phase, neutral & earth) Make of Wire :- Havells/Polycab/Finolex/RPG/V-Guard/KEI drawn through in and incl PVC rigid conduit medium grade FRLS as per IS-9537 Make of Conduit:- AKG/Atul/Lalinga/Precision /Modi of suitable sizes as per IS-732 as per BIS specification with its accessories not less than 20 mm dia with pressed steel terminal box incld 3mm thick ISI marked laminated sheet cover for fixing switches/socket/regulators etc for the following: - Note:-(i) On RCC ceiling/column, false ceilling, AC/Metallic Sheet ceilling wiring done on surface with conduit and its accessories. (ii) Common earth and neutral dolly should be provided in each terminal box/junction box/switch board having more than 2 points.
One light/fan/bell point controlled by one No piano type switch 5 Amps single pole one way complete all as specified and directed.
One light point controlled by 2-way piano type switches 5 Amps two way for stair case complete all as specified and directed.
One socket outlet 5/3 pin 5 amps controlled by one switch on the same board complete all as specified and directed.
One socket outlet 5/3 pin 5/6 amps controlled by one switch on independent board complete all as specified and directed.
All as per item NO 72 above but 3 pin socket out let 15/16 Amps on the independent Board all as spfd with single core unsheated PVC insulated cable multistranded copper conductor of size 4 sq mm for phase & neutral & 4 sq mm for earth continuity conductor complete all as specified and directed.
S&F Switch Piano Flush button single pole one way 5/6 Amp complete all as specified and directed. MAKE:- Anchor(Penta)/Havells (Reo)/Gold Medal
S&F Switch Piano Flush button single pole two way 5/6 Amp complete all as specified and directed. MAKE:- Anchor(Penta)/Havells (Reo)/Gold Medal
S&F Switch Piano Flush button single pole one way 15/16 Amp complete all as specified and directed. MAKE:- Anchor(Penta)/Havells (Reo)/Gold Medal
S&F socket outlet 2 in 1, 3 pin & 2 pin, 5/6 Amp, 240 volt complete all as specified and directed. MAKE:- Anchor(Penta)/Havells (Reo)/Gold Medal
S&F socket outlet 2 in 1 , 3 pin & 2 pin, 5/6 Amp and 15/16 Amp, 240 volt complete all as specified and directed. MAKE:- Anchor(Penta)/Havells (Reo)/Gold Medal
S&F ceiling rose surface bakelite 65mmx50mm three terminal complete all as specified and directed. MAKE:- Anchor(Penta)/Cona/Gold Medal
S&F step type electronic fan regulator flush type 80/60 watt on the existing phenolic laminated sheet complete all as specified and directed. MAKE:-Anchor(Penta)/Havells (Reo)/Gold Medal
S&F Lamp hoder/Batten holder PVC/Polycarbonate insulated body with back plate for batten fittingcomplete all as specified and directed. MAKE:- Anchor(Penta)/Havells (Reo)/Gold Medal
S&F Bell Multi Music type, AC 230 Volts, Single pole complete all as specified and directed. MAKE:- Anchor(Penta)/Havells (Reo)/Gold Medal
S&F Bell Push, flush type, 5 Amp, AC-230 Volts, single pole complete all as specified and directed. MAKE:- Anchor(Penta)/Havells (Reo)/Gold Medal
M&L for point wiring concealed type with 4 sq mm FRLSH PVC insulated unsheathed single core multithreaded copper conductor cable 1100 volts grade of three run ( phase, neutral & earth) Make of Wire : Havells/Polycab/Finolex/RPG/V-Guard/KEI drawn through in and incl PVC rigid conduit medium grade FRLS as per IS-9537 Make of Conduit AKG/Atul/Lalinga/Precision/Modi of suitable sizes as per IS-732 as per BIS specification with its accessories not less than 25 mm dia with pressed steel terminal box incld 3mm thick ISI marked laminated sheet cover for fixing switches/socket/regulators etc for the following: - Note:-(i) On RCC ceiling/column, false ceilling, AC/Metallic Sheet ceilling wiring done on surface with conduit and its accessories. (ii) Common earth and neutral dolly should be provided in each terminal box/junction box/switch board having more than 2 points.
M&L for point wiring concealed type with 6 sq mm FRLSH PVC insulated unsheathed single core multithreaded copper conductor cable 1100 volts grade of three run ( phase, neutral & earth) Make of Wire:- Havells/Polycab/Finolex/RPG/V-Guard/KEI drawn through in and incl PVC rigid conduit medium grade FRLS as per IS-9537 Make of Conduit :- AKG/Atul/Lalinga/Precision/ Modi of suitable sizes as per IS-732 as per BIS specification with its accessories not less than 25 mm dia with pressed steel terminal box incld 3mm thick ISI marked laminated sheet cover for fixing switches/socket/regulators etc for the following: - Note:-(i) On RCC ceiling/column, false ceilling, AC/Metallic Sheet ceilling wiring done on surface with conduit and its accessories. (ii) Common earth and neutral dolly should be provided in each terminal box/junction box/switch board having more than 2 points.
S&F sheet metal enclousure for MCB DB single pole and neutral 8 way with 200 Amps rated bus bar 240 volts double door (Metallic) type complete all as specified and directed. Make:-L&T/Indoasian/Siemens
S&F sheet metal enclousure for MCCB 63 Amps Triple pole and neutral complete all as specified and directed. Make - Make:-L&T/Indoasian/Siemens
S&F MCCB 63 Amp 16 KA,Four pole, fixed type, 440 volt.50 Hz complete all as specified and directed. Make:- L&T/Indoasian/Siemens
S&F MCB SP 5 to 30 Amps 240 volts 'C' series, 10 KA, 50 Hz, confirming to IS/IEC-60898-1 complete all as specified and directed. Make:- L&T/Indoasian/Siemens
S&F MCB SP 5 to 30 Amps 240 volts 'B' series, 10 KA, 50 Hz, confirming to IS/IEC-60898-1 complete all as specified and directed. Make:- L&T/Indoasian/Siemens
S&F MCB SPN 20 to 40 Amps 240 volts 'C' series, 10 KA, 50 Hz, confirming to IS/IEC-60898-1 complete all as specified and directed. Make:- L&T/Indoasian/Siemens
Material and Labour for earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground( earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level, connected to galvanized steel earth lead MS flat 32X6 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel, all as shown in electrical plate No 3 of SSR Pt I including necessary excavation and earth work PCC (1:3:6) type C-1 with 50 mm thick pre cast RCC ( 1:2:4) type B-1 cover slab framed with 50X30X4 mm MS angle (reinforced with 6 mm dia deformed bar @ 15 cm C/C both ways and suitable handle of 10 mm dia round bar) including providing charcoal or coke and magnesium sulphate in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel and 20 mm bore galvanized iron watering pipe (medium grade) wire mesh, copper lugs, complete in all respect., GI earth wire protected by 40 mm bore (light grade) galvanized iron pipe and other end connected to the earth bar (test point) made of MS flat (400X32X6 mm) bend in ‘D’ shape and fixed to wall by means of fast nut or bolt grouted in to wall at 1 mtr from plinth height. 4sqmm PVC insulated (colour green) copper conductor single run as earth continuity conductor along with 15 mm PVC conduit grouted in wall or fixed on wall surface to be continued up to main switch board and fix with common earth dolly as directed by EIC . Disposal of soil to a distance not exceeding 50 mtr and necessary testing on completion complete all as specified and directed.
M & L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as required 4mm dia galvanised Iron or steel wire complete all as specified and directed.
Supply & Fixing in replacement of tube light fitting LED 20 Watt, 6000K, 230 Volt, LED batten complete with high brightness LED tube rod in opal finish and connection with PVC insulated multi stranded copper flexible wire twin core of suitable size from nearest source complete all as specified and directed. Make : Bajaj/ Havells/ Philips.
M & L of Replacement of existing Damage Meter Box of size 700 X 480 X 210 mm for fixing energy meter -04 Nos and other accessories in the same box on wall flush/semi wall flush and connection PCC work/brick work with cement plastering for make good the existing surface along with all electrical connection ccomplete all as specified and directed. Make & Model : Sintex ( GSMB-7450 ) , EPP ( EPPMMB700480SD )
Supply & Fitting Integral LED building security light fittings Endura PEARL luminaire 25 watt, energy saving and environment friendly long life pressure die -cast aluminium hosing high power LED as lighting source and lens embedded PC cover having TOP OPENING separate driver compartment with IP-65 Protection and impact resistance of IK07 along with 600 mm X 25 mm bracket , made of GI Pipe (light grade ) and fast nuts, for fixing arrangements,complete all as specified and directed. MAKE : Havells Model ENDURAPEARLSL25WLED757SASYTOPC or equivalent make from Philips/CG.
Supply & Fixing Photo cell LDR sensor for automatic Day/Night operation, suitable for 220 Volts, 10 Amps complete all as specified and directed. Make:- Blackt Electrotech BT31P2/Xcluma/Bulfyss/Quick Sense (QS-301).
Supply & Fix Exhaust Fans AC Single Phase 230/240 Volt of size 150 mm sweep with louver complete all as specified and directed. Make- Havells/Orient/Crompton & Greaves
Supply and fix Water Heater Storage type, electric, capacity 25 Ltrs. BEE 5 star rated complete all as specified and directed. Make : HAVELLS/Crompton Greave/Bajaj.
M/S A.R BUILDERS
M/S Kharya Associates
HARNAM SINGH ANIL SINGH
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .