Loading…
Loading…
Tender Value
₹71.7 L
EMD Value
₹1.4 L
Closing Date
25 Sept 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
SIGNAL
13 conditions · 2 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less, where: -V= Advertised value of the tender in crores of RupeesN= Number of years prescribed for completion of work for which bids have been invited.The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case the balance sheet of the previous year is yet to be prepared/audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover.The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.Client certificate from other than Govt Organization should be duly supported by Form 16A/26AS generated through TRACES of Income Tax Department of India.
Tenderer must have successfully completed any of the following during last 07 (SEVEN) years, ending the last day of month previous to the one in which tender is invited.One Similar work, each costing not less than the amount equal to 60% of the advertised value of the tender. (OR)Two Similar works, each costing not less than the amount equal to 40% of the advertised value of the tender.(OR)Three Similar works, each costing not less than the amount equal to 30% of the advertised value of the tender.Work experience certificate from a Private individual shall not be considered. However, in addition to work experience certificates issued by any Govt Organisation, the work experience certificate issued by Public Listed Company has an average annual turnover of Rs. 500 Crores and above in last 3 Financial Years excluding the current financial year, listed on National Stock Exchange or Bombay Stock Exchange, incorporated/registered at least five years prior to the date of opening of tender, shall also be considered provided the work experience certificate has been issued by a person authorized by the Public Listed company to issue such certificates.In case tenderer submits work experience certificate issued by Public listed company, the tenderer shall also submit along with work experience certificate, the relevant copy of work order, bill of quantities, bill wise details of payment received duly certified by Chartered Accountant, TDS certificates for all payments received and copy of final/last bill paid by the company in support of above work experience certificate.The tenderer shall submit a certificate to this effect in the format given in Form No.1 (in Forms & Annexure part of Chapter - 3) of the tender document. Certificates to be duly certified by minimum JAG Officer.
37 conditions · 12 needing a document upload
Undertaking that the item will be procured from RDSO Approved firm.
Statement of Deviation
Power of Attorney
Certificate to be submitted / uploaded by tenderer along with the tender documents (Annexure V), Part I of GCC.
Annexure-V(A), Part I of GCC (This certificate is to be given by attorney/authorized signatory/each member of Partnership firm/Joint Venture (JV)/Hindu Undivided Family (HUF) / Limited Liability Partnership (LLP) etc.)
(Bid Security) Bank Guarantee Bond from any scheduled commercial bank of India (Annexure VI(A)
EMD Submitted
List of personnel, organization available on hand and proposed to be engaged for the subject work.
List of plant & machinery available on hand (own) and proposed to be inducted (own and hired to be given separately) for the subject work.
List of works completed in the last three financial years giving description of work, organization for whom executed, approximate value of contract at the time of award, date of award and date of scheduled completion of work. Date of actual start, actual completion and final value of contract should also be given
List of works on hand indicating description of work, contract value, approximate value of balance work yet to be done and date of award.
Copy of PAN card
Documents for Turnover for financial eligibility criteria
Documents for technical eligibility criteria - Performance certificates for single similar nature of work
NEFT Details
GST Registration Certificate Copy
Bid Security Declaration in lieu of EMD Submitted
Organization details
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less, where: -V= Advertised value of the tender in crores of RupeesN= Number of years prescribed for completion of work for which bids have been invited.The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case the balance sheet of the previous year is yet to be prepared/audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover.The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.Client certificate from other than Govt Organization should be duly supported by Form 16A/26AS generated through TRACES of Income Tax Department of India.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Power of Attorney
Annexure-V(A), Part I of GCC (This certificate is to be given by attorney/authorized signatory/each member of Partnership firm/Joint Venture (JV)/Hindu Undivided Family (HUF) / Limited Liability Partnership (LLP) etc.)
(Bid Security) Bank Guarantee Bond from any scheduled commercial bank of India (Annexure VI(A)
NEFT Details
Copy of PAN card
Organization details
GST REGISTRATION/ A CERTIFCATE FOR NON-APPLICABILITY OF GST REGISTRATION
Bid Security Declaration in lieu of EMD Submitted
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
SIGNALLING AND TELECOM PORTION OF WORK LIMITED USE SUBWAY (LUS) IN CONNECTION WITH ENGINEERING WORKS IN MAS-AJJ SECTION
M-SG-2026-525-LUS_MAS_AJJ~SR
M-SG-2026-525-LUS_MAS_AJJ
Open
Works - General
12 Months
Chennai, Tamil Nadu
₹0
₹1.4 L
25 Sept 2026
31 Aug 2026
11 Sept 2026
59 items across 2 schedules · ₹56,17,083.99 total
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| 1 | Supply and Provision o f Earthing a s per RDSO Specification RDSO/SPN/197/2008 or latest (as per Technical Specification enclosed) | Numbers | 4.00 | 28,118.51 | 1,12,474.04 |
| 2 | Supply o f earth electrodes (GI) a s p e r Drg no SG/CN/02/13 | Numbers | 8.00 | 1,618.75 | 12,950 |
| 3 | Provision of earth electrodes as per drawing No.SG/CN/02/13 and earthing of metallic sheath and armour of all cables in all apparatus cases, relay room, equipment room, SM's room for block and control, and earthing of all equipments in apparatus cases, power room, relay rack, cable termination rack, control panel, signals, lever frames with MS flat 35mm X 6mm/19c cable (MS flat for closer by areas and MS flat/19c cable combination for farther areas) as per the instructions of Railway representative at site. The work includes painting of earth resistance value on the earth pit. (Supply of 19C cable is not covered in the scope of this schedule). [MS flat for earthing 35mm X 6mm, cement, GI earth electrodes, common salt, charcoal, country bricks, M sand, soldering materials and all other miscellaneous materials required for the work shall be supplied by the Contractor]. | Numbers | 8.00 | 1,707.55 | 13,660.4 |
| 4 | Supply of Modular Terminal Block of 2.5sq.mm 2 IN 2 OUT type disconnect type of Wago/Phoenix make or similar along with accessories a s p e r RDSO Spec.No.RDSO/SPN/189/2004/ rev 2 or latest. | Numbers | 500.00 | 194.95 | 97,475 |
| 5 | "Supply o f F U S E terminals b l o c k w i t h LED indication upto 2.5sq.mm screw type 1 IN 1 O U T ( Suitable 400mA, 630mA, 1 A , 1.6A, 2A, 4A, 6.3A, & 10A) (Without Fuse) as per RDSO Spec.No.RDSO/SPN/189/2004/ rev 2 or latest." | Numbers | 100.00 | 219.87 | 21,987 |
| 6 | Supply of DIN channel for the terminal | Metre | 80.00 | 344.87 | 27,589.6 |
| 7 | Supply o f E N D plates f o r modular terminal block | Numbers | 50.00 | 36.86 | 1,843 |
| 8 | Supply o f E N D c l a m p f o r modular terminal block | Numbers | 50.00 | 26.35 | 1,317.5 |
| 9 | Supply of Shorting Link insulated Grey in color | Numbers | 50.00 | 21.2 | 1,060 |
| 10 | Supply o f operating t o o l , s c r e w d r i v e r and stripper for modular terminal. These tools shall be of Wago/Phoenix make or similar and model suitable for the modular terminal supplied | Numbers | 1.00 | 12,246.29 | 12,246.29 |
| 11 | Supply of FUSE links of (400mA, 630mA, 1A, 1.6A, 2A, 4A, 6.3A & 10A) | Numbers | 100.00 | 61.74 | 6,174 |
| 12 | Fixing o f Modular terminal block/fuse block along with accessories with provision of fixing holes o n hylam sheet/side angles of Location B o x a n d fixing b y Galvanized nuts and bolts. This includes fixing of DIN channel for cable termination on Modular terminal | Numbers | 600.00 | 28.97 | 17,382 |
| 13 | Supply a n d provision o f n o r m a l j o i n t using Thermo shrink jointing k i t ( R D S O s p e c s No TC/77/2012 ( Rev.3) with amendment No.1&2 or latest.& jointing kit to be inspected by RDSO) f o r 4 / 6 q u a d cable normal joint. The work i n c l u d e s excavation of j o i n t p i t o f size 1mX1.5mX1.5m and closing t h e s a m e after completion of cable joint as per the instruction of Railway representative at site. | Numbers | 8.00 | 4,628.91 | 37,031.28 |
| 14 | S u p p l y a n d installation o f 4 8 fi b r e Joint enclosure f o r armoured optic a l fi b r e cable c o n f o r m i n g to RDSO spec.RDSO/SPN/TC/68/2014 rev2.1 or latest | Numbers | 4.00 | 20,060 | 80,240 |
| 15 | Supply of RCC cable markers (Supply of RCC cable markers a s p e r drawing No.CSTE/CN/OFC/1. T h e lettering o n the cable marker shall be "SIG" / "TELE" / "OFC" as per t h e instructions o f Railway representative at site.) as per drawing enclosed | Numbers | 20.00 | 262.65 | 5,253 |
| 16 | Excavation of cable trench in all kinds of soil except hard rocky areas including clearing of roots of trees, rocks, bushes etc. to a depth of 1.0 Mtrs and to a width of 0.3 Mtrs. (Laying of cables is not included in this schedule) | Metre | 2000.00 | 64.1 | 1,28,200 |
| 17 | Excavation of trench to a depth of 1 Mtr. for track crossing of cables, refilling of trench by ram m ing a n d consolidating i t a s p e r the instructions of Railway representative at site a f t e r l a y i n g o f D W C / RC C p i p e s . During excavation of trench, it has to be ensured that the excavated soil does not mix with the ballast available. The depth of 1m trench shall be from t h e bottom o f sleepers for track crossings. Laying of cables and DWC pipes is not included in this schedule. (Supply of DWC/RCC pipes with couplers/collars is not included in this schedule). | Metre | 80.00 | 385.45 | 30,836 |
| 18 | Provision of GI pipes (50/100mm dia) for cable laying with offset at both ends and with couplings over RCC bridges, drainage, culverts, and girder bridges. For RCC bridges, drainage, and culverts, the pipes shall be mounted on concrete masonry supports of size 300mm x 300mm x 300mm at an interval of 2 meters. For girder bridges, the pipes shall be fixed on suitable MS clamps at an interval of 2 meters. The ends of the pipes shall be closed with brick masonry abutments to ensure that no cable is exposed. The work shall be carried out as per the instructions of the Railway representative at the site.(Supply of GI pipes with couplings and laying of cables is not included in this schedule).Stone jelly (20/25mm size), bricks, sand, cement, MS angles, flats, bolts, nuts for manufacturing and fixing clamps, bricks, M sand, cement, and other miscellaneous materials for the work shall be supplied by the contractor. | Metre | 100.00 | 208.54 | 20,854 |
| 19 | Provision of GI pipes (50/100mm dia) for cable laying in hard rocky area with off sets at both ends duly supported by concrete blocks of size 300mm x 300 mm x 300 mm at an interval of 2m. The ends of the pipes shall be closed with brick masonry abutments work so that no cable is exposed, The work shall be carried out as per the instructions of Railway representative at site.(Supply of GI pipes with couplings and laying of cables is not included in this schedule).[Stone jelly of size 20/25mm, bricks, sand, cement, a n d a l l o t h e r miscellaneous materials required f o r t h e w o r k s h a l l be supplied by the Contractor]. | Metre | 50.00 | 182.87 | 9,143.5 |
| 20 | Laying o f signaling/power/ telecommunication cables a s p e r cable plan in cable trenches, masonry ducts, RCC Pipes, DWC pipes, GI Pipes etc.(Supply o f cables i s n o t included i n this schedule). | Metre | 9000.00 | 18.18 | 1,63,620 |
| 21 | Placing of one row of country bricks of size approximately 2 2 0 m m x 1 0 0 m m x 60mm breadth wise horizontally above the cables in 0.3m width trench.[Country bricks of size 220mm x 100mm x60 mm (approximately) shall be supplied by the Contractor]. | Metre | 2000.00 | 62.99 | 1,25,980 |
| 22 | "Refilling of cable trench 1m depth by 0.3m width throughout, with earth after laying of c a b l e s , a n d consolidating t h e t r e n c h by ramming and levelling." | Metre | 2000.00 | 15.4 | 30,800 |
| 23 | "Digging of pit to a depth of 800mm of size 300mmX300mm, c a s t i n g o f concrete foundation o f s i z e 300mmX300mmX300mm and Placing of RCC cable markers on top of the f o u n d a t i o n a n d r e fi l l i n g t h e p i t and consolidating it by ramming. The cable markers shall b e provided a t a n interval of 20 Mtrs. within station limits and 50 Mtrs. outside station limits throughout t h e cable route, diversions and also at every track/road crossing." | Numbers | 20.00 | 123.35 | 2,467 |
| 24 | B l o w i n g / D r a w i n g o f O F C cable/Power cable/Signalling cable inside permanently solid lubricated HDPE Pipe already laid. This work includes necessary duct integrity test for solid l u b r i c a t e d H D P E p i p e . ( This includes Transportation o f materials from nominated stores to site) | Metre | 2000.00 | 23.43 | 46,860 |
| 25 | Manufacture and supply of M.S. relay frames of suitable size to hold up to 4/ 8/ 12/ 2 0 relays /plug in type as required by Railways and fixing them in apparatus cases for all types of signal control circuits, LC gate control circuit and Point control circuits, fixing o f plug boards, relays, r e s i s t o r s and electrolytic condensers on Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, wiring and termination as per approved circuit diagram and painting the particulars.[Wire PVC copper, 3/0.75mm and 16/0.2mm c o p p e r , Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, for fixing resistors and condensers, M S fl a t s 2 5 m m x 6 m m brass bolts a n d nuts, paints, soldering materials, resistors, condensers a n d a l l other miscellaneous materials required f o r the work shall be supplied by the contractor]. a)Wiring of Signal/ point/ LC control circuit (up to 4 relays/Plug in type) | Set | 4.00 | 4,945.51 | 19,782.04 |
| 26 | Carrying out alterations to the existing relays in the relay racks/apparatus cases as per the approved circuit diagram using wire PVC 16/0.2mm copper. T h e work includes painting alterations a n d releasing the unwanted wires carefully without disturbing the existing wiring. [ W i r e P V C 1 6 / 0 . 2 m m c o p p e r , soldering m a t e r i a l s , b u n c h i n g t h r e a d s , condensers, resistances and teakwood plank for fixing them and all other miscellaneous materials required f o r t h e w o r k s h a l l b e s u p p l i e d by the Contractor]. | Per Relay | 40.00 | 695.67 | 27,826.8 |
| 27 | Supply of Handheld True RMS Multi Meter, as per Technical specification | Numbers | 1.00 | 23,192.34 | 23,192.34 |
| 28 | Supply of Handheld True RMS clamp Meter, as per Technical specification | Numbers | 1.00 | 33,510.29 | 33,510.29 |
| 29 | Supply of Portable Cable Fault Locator as per Technical specification | Numbers | 1.00 | 1,86,694.53 | 1,86,694.53 |
| 30 | S u p p l y o f Ro d o m e t e r a s p e r Technical specification | Numbers | 1.00 | 4,252.24 | 4,252.24 |
| 31 | Supply o f D o u b l e w a l l e d corrugated p i p e - 1 0 3 . 5 m m i n n e r d i a & 1 2 0 m m o u t e r dia conforming t o specification N o . IS 14930(Part 2): 2001 with one coupler for every 6m of pipe as per Technical specification | Metre | 80.00 | 365.19 | 29,215.2 |
| 32 | Supply of GI pipes - 100mm dia-4.5mm thick as per Technical specification | Metre | 150.00 | 1,119.16 | 1,67,874 |
| 33 | S u p p l y o f High-Density Polyethylene Pipes (HDPE) of 110 mm Outer Dia, 10 mm Wall Thickness, along with one coupler for every 6 Meters a s per specification N o . I S 4984: 2016 with latest amendments and Material Grade:PE 80 | Metre | 150.00 | 853.55 | 1,28,032.5 |
| 34 | Supply and laying of PVC Warning Tape colour Orange, width of 250mm (10") by printing with b l a c k l e t t e r s 'Indian RailwaySignal/Telecom/OFC Cable' on both sides | Metre | 2000.00 | 46.15 | 92,300 |
| 35 | Supply of HDPE Pipe 40mm (outer dia)/33 mm (inner dia) with couplers | Metre | 2000.00 | 60.93 | 1,21,860 |
| 36 | Supply of track lead junction box - FRP type with 4 terminals and stumps with necessary i n s p e c t i o n a s p e r specification/ drawing/ description enclosed in this document. | Numbers | 20.00 | 1,622.5 | 32,450 |
| 37 | Supply o f PBT terminals 25mm/ 60mm centre and PBT Fuse blocks with necessary inspection a s p e r specification/ drawing/ description enclosed in this document. a)Supply of PBT terminals 25mm centre. | Numbers | 2000.00 | 61.44 | 1,22,880 |
| 38 | Supply o f PBT terminals 25mm/ 60mm centre and PBT Fuse blocks with necessary inspection a s p e r specification/ drawing/ description enclosed in this document. b)Supply of PBT terminals 60mm centre. | Numbers | 100.00 | 93.02 | 9,302 |
| 39 | Supply o f PBT terminals 25mm/ 60mm centre and PBT Fuse blocks with necessary inspection a s p e r specification/ drawing/ description enclosed in this document. c)Supply of PBT fuse block without ND fuse | Numbers | 150.00 | 103.84 | 15,576 |
| 40 | Fi l l i n g e a r t h a r o u n d l o c a t i o n boxes/signal foundations for a width of 0.5m on all sides, up t o a level 150mm below t h e foundation top. This w ork includes consolidation of earth by watering and ramming.The earth shall be taken from Railway premises as instructed by Railway representative at site. | cum | 5.00 | 231.3 | 1,156.5 |
| 41 | Excavation o f pit, casting concrete foundation and erection of apparatus case full size a s per Drg. No.SG/CN/02/6 and fixing of 2 Nos. of 'E' type locks, one for the front door and another for the back door, fixing of one hard wood shelf plank 37mm thick and painting the apparatus case inside and outside with one coat of red- oxide and two coats of aluminium paints. (Supply of apparatus case is not included in this schedule).[Foundation bolts & nuts, 'E' type locks, cement, M sand, stone jelly of size 20/25 mm, hardwood plank of 37mm thick, paints, varnish, fi x i n g b o l t s & n u t s a n d a l l other miscellaneous materials required f o r thework shall be supplied by the Contractor.] | Numbers | 6.00 | 11,333.1 | 67,998.6 |
| 42 | "Excavation of pit, casting concrete foundation and erection of apparatus case half size as per Drg, No.SG/CN/02/7, fixing one 'E' type lock for the front door and latching arrangement for the back door, and fixing o f o n e hardwood shelf plank 37mm thick and painting the apparatus case inside and outside with one coat of red- oxide and two coats of aluminium paints. (Supply of apparatus case is not included in this schedule).[Foundation bolts and nuts, cement, 'E' type locks, M sand, stone jelly of size 20/25mm,37mm hard wood planks, latching ""arrangements, paints, varnish, fixing bolts & nuts a n d a l l o t h e r miscellaneous materials required f o r t h e w o r k s h a l l be supplied by the Contractor]""" | Numbers | 2.00 | 8,787.04 | 17,574.08 |
| 43 | Termination o f n e w main/tail cables o n the existing terminals/ fuse blocks in apparatus c a s e s / b a t t e r y b o x e s / C T b o x e s / cable termination r a c k s a s p e r approved circuit diagram. T h e terminal particulars a r e to be repainted /corrected on the doors of apparatus cases/ battery boxes/ cable termination boxes and FTOT index board as instructed by Railway representative at site. This w o r k includes closing t h e opening created f o r entry o f new cables i n the apparatus cases w i t h masonry b r i c k work and sealing t h e b o t t o m o f the apparatus cases/ cable termination racks with cable compound.[Paints, wire PVC 3/0.75mm and 16/0.2mm copper, s e a l i n g compound, bricks, cement, M sand and all other required miscellaneous materials shall b e supplied by the contractor].(Per Unit = Per Terminal block) | Per Unit | 200.00 | 73.59 | 14,718 |
| 44 | Termination of main, tail, Signaling and power cables a n d internal wiring on terminal/ fuse b l o c k s i n n e w apparatus cases, cable termination b o x e s a n d i n gate Lodges excluding cable termination rack at relay room. The work includes fixing of all new cables by teakwood clamp on teakwood base plank, fixing of Phynolic synthetic industrial fibre base fine weave cotton fibre board 6mm thick for terminal board to suit each apparatus case, varnishing all teakwood i t e m s , fi x i n g of terminals/ fuse blocks o n t h e terminal board, drilling of necessary h o l e s , termination of cables, wiring, identification o f cables using aluminium tags with letters punched neatly, as per approved circuit diagram a n d cable plan, painting o f particulars o n sleeves andalso on the inner side of the doors of apparatus cases. After terminations are "over, the side openings o f apparatus case foundation shall b e closed with brick work, cement plastered, the inter- space filled with M sand u p t o base level and the bottom surface shall be sealed with sealing compound.(Supply of PBT terminals and Fuse blocks is not c o v e r e d i n t h i s schedule)." a)Termination on 25/60mm PBT terminals (new location)(Phynolic sheet)(Per Unit = Per Terminal block) | Per Unit | 1600.00 | 172.14 | 2,75,424 |
| 45 | Termination of main, tail, Signaling and power cables a n d internal wiring on terminal/ fuse b l o c k s i n n e w apparatus cases, cable termination b o x e s a n d i n gate Lodges excluding cable termination rack at relay room. The work includes fixing of all new cables by teakwood clamp on teakwood base plank, fixing of Phynolic synthetic industrial fibre base fine weave cotton fibre board 6mm thick for terminal board to suit each apparatus case, varnishing all teakwood i t e m s , fi x i n g of terminals/ fuse blocks o n t h e terminal board, drilling of necessary h o l e s , termination of cables, wiring, identification o f cables using aluminium tags with letters punched neatly, as per approved circuit diagram a n d cable plan, painting o f particulars o n sleeves andalso on the inner side of the doors of apparatus cases. After terminations are "over, the side openings o f apparatus case foundation shall b e closed with brick work, cement plastered, the inter- space filled with M sand u p t o base level and the bottom surface shall be sealed with sealing compound.(Supply of PBT terminals and Fuse blocks is not c o v e r e d i n t h i s schedule)." b)Termination on PBT fuse block (new location) (Phynolic sheet)(Per Unit = Per Fuse block) | Per Unit | 100.00 | 209.93 | 20,993 |
| 46 | Termination of main, tail, Signaling and power cables and internal wiring b y fixing additional terminals/ fuse blocks o n the existing terminal boards of apparatus cases, cable termination boxes etc. The work includes fixing of all new cables by teakwood clamp o n teakwood base plank, varnishing all teakwood items, fixing of terminals/ fuse blocks, on the existing terminal boards, drilling of necessary holes, termination of cables, wiring, identification o f cables using aluminium tags with letters punched neatly, as per approved circuit diagram a n d cable plan, painting o f particulars o n sleeves and also on the inner side of the doors of apparatus cases. After terminations are over, the side openings o f apparatus case foundation shall b e closed with brick work, cement plastered, the inter- space filled with M sand u p t o base level and the bottom surface shall be sealed with sealing compound. a)Termination o f c a b l e s on 25/60mm PBT terminals (existing location)(Per Unit = Per Terminal block) | Per Unit | 500.00 | 151.09 | 75,545 |
| 47 | Termination of main, tail, Signaling and power cables and internal wiring b y fixing additional terminals/ fuse blocks o n the existing terminal boards of apparatus cases, cable termination boxes etc. The work includes fixing of all new cables by teakwood clamp o n teakwood base plank, varnishing all teakwood items, fixing of terminals/ fuse blocks, on the existing terminal boards, drilling of necessary holes, termination of cables, wiring, identification o f cables using aluminium tags with letters punched neatly, as per approved circuit diagram a n d cable plan, painting o f particulars o n sleeves and also on the inner side of the doors of apparatus cases. After terminations are over, the side openings o f apparatus case foundation shall b e closed with brick work, cement plastered, the inter- space filled with M sand u p t o base level and the bottom surface shall be sealed with sealing compound. b)Termination of cables on PBT fuse block (existing location)(Per Unit = Per Fuse block) | Per Unit | 50.00 | 188.86 | 9,443 |
| 48 | Provision of HDPE Pipe of dia 40/33 mm | Metre | 2000.00 | 26.11 | 52,220 |
| 49 | Releasing o f existing apparatus c a s e s (Full/ H a l f / Q u a r t e r s i z e ) w i t h o u t d a m a g e after releasing the s h e l f planks, Terminal blocks, Fu s e Blocks, Terminal Boards, Relays o f all t y p e s E K T s , S e c o n d a r y Cells, power equipments, 'E' type locks, etc., and breaking t h e concrete foundation. After releasing, the resultant pits are to be closed and consolidated b y ramming and levelling. The released materials shall be accounted and stacked a t a place a s instructed by Railway representative at site. | Numbers | 4.00 | 3,006.71 | 12,026.84 |
| 50 | Dismantling and releasing of existing Colour light Signals complete (upto 4 aspects) with or without Ro u t e Indicators, calling on signals, shunt signals etc., carefully without any damage to the gadgets, accounting and stacking them neatly at a place as instructed by Railway representative at site. The work i n c l u d e s b r e a k i n g t h e concrete foundation,closing t h e r e s u l t a n t p i t and resurfacing it by ramming and levelling. | Numbers | 4.00 | 3,083.03 | 12,332.12 |
| 51 | Protection adjustments and re-instating of S&T gears by deputation of Helpers/Unskilled Labour for executing additional S&T portion of t h e w o r k s . The work can involve fixing, releasing, dismantling, replacement,excavation, clearing of vegetation, loading and unloadingof material and assisting skilled persons etc as per instruction of Railway representative. | Man- Days | 20.00 | 847.59 | 16,951.8 |
| 52 | Protection, adjustment a n d reinstating of S&T g e a r s b y d e p u t a t i o n of Fitter/Wireman/Painter/Welder/ Mason/Cable Jointer (Skilled Labour or Technician ) etc., for executing additional S&T portion of works. The work can involve fixing, releasing, dismantling, replacement, painting or alteration o f various signallilng assets or parts, termination of cable s, m i n o r patch work on damages at location box, Plastering, Concreting brick work, wiring alterations, cable jointing e t c a s per instruction of Railway representatives at size. | Man- Days | 10.00 | 1,073.45 | 10,734.5 |
| 53 | Transportation o f Signalling materials by road a s p e r t h e instructions o f Railway representative a t site. T h e work also includes l o a d i n g a n d u n l o a d i n g o f the materials a)Transportation o f Signalling materials upto 100kms | MT-Km | 500.00 | 22.75 | 11,375 |
| 54 | Engaging mechanical excavators like JCB or other machineries for regarding and levelling t h e form atio n, dismantling a n y infringing structures, clearing a n d removing debris etc., with all leads and lifts etc., complete and as per t h e instruction o f Railway representative at site. | Hour | 16.00 | 1,202.5 | 19,240 |
| Schedule total | ₹26,39,923.99 | ||||
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
JPOforundertakingtheDiggingwork1_1.pdf
ATTACHMENT
GCC_April-2022_2022_CE-I_CT_GCC-2022_POLICY_27.04.22_1.pdf
ATTACHMENT
SOR2022BOOKLETNew1_compressed1_1.pdf
ATTACHMENT
GCCCSlip1to10_compressed_1.pdf
ATTACHMENT
GCCCNo11_1.pdf
ATTACHMENT
PDFGCCACS12.pdf
ATTACHMENT
SOUTHERNRAILWAYTENDERM-SG-2026-LUS-MAS-AJJ-GoogleDocs_1.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .