Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹344.6 CrAccepted-AOC | ₹344.6 Cr | L1 | Accepted-AOC P.O. Placed |
| 2 | L2₹362.6 CrRejected-AOC CRYSTAL TOWER 4TH FLOOR TELIBANDHA RAIPUR | RAIPUR | RAIPUR | CHHATTISGARH | ₹362.6 Cr | L2 | Rejected-AOC Unsuccessful |
| 3 | L3₹411.8 CrRejected-AOC D 90 OKHLA INDUSTRIAL AREA PHASE 1 NEW DELHI NEW DELHI DELHI 110020 | SOUTH EAST DELHI | DELHI | 110020 | ₹411.8 Cr | L3 | Rejected-AOC Unsuccessful |
Tender Value
₹332.0 Cr
EMD Value
₹5 Cr
Closing Date
11 Oct 2022, 5:00 pmClosed
CEPL
CEPL, BEST Bhavan, Electric House, Colaba, Mumbai
DEVELOPMENT OF RECEIVING SUB-STATIONS (RSS) WORK AT BEST
2022_BEST_795835_1
DMM(SB)/09/TCU/73748/2022-23/A
Open Tender
Electrical and Maintenance Works
1460 days
Mumbai
Refer Tender Document
5 documents required · 5 mandatory
₹12,000
₹5 Cr
Yes
Electric House, Colaba
7 Feb 2023
6 May 2022
13 Oct 2022
6 May 2022
11 Oct 2022
25 May 2022
7 May 2022 - 18 May 2022
20 May 2022
Replacement of 33 KV Switchgears
Supply, Installation & Commissioning of 33kV 1500 MVA Switchgears for TRF-1 by dismantling & replacing exisiting switchgear at Mazgaon Dock RSS
Supply, Installation & Commissioning of 33kV 1500 MVA Switchgears for TRF-2 & 3 by dismantling & replacing exisiting switchgear at Bellard Estate RSS
Supply, Installation & Commissioning of 33kV 1500 MVA Switchgears for TRF-2 by dismantling & replacing exisiting switchgear at Sion Fort RSS
Supply, Installation & Commissioning of 33kV 1500 MVA Switchgears for TRF-2 & 3 by dismantling & replacing exisiting switchgear at Sewree RSS
Supply, Installation & Commissioning of 33kV 1500 MVA Switchgears for TRF-2 & 3 by dismantling & replacing exisiting switchgear at Mumbadevi RSS
Supply, Installation & Commissioning of 33kV 1500 MVA Switchgears for TRF-1 & 2 by dismantling & replacing exisiting switchgear at G T Hospital RSS
Supply, Installation & Commissioning of 33kV 1500 MVA Switchgears for TRF-1 & 2 by dismantling & replacing exisiting switchgear at Mahim RSS
Supply, Installation & Commissioning of 33kV 1500 MVA Switchgears for TRF-3 by dismantling & replacing exisiting switchgear at Masjid RSS
Supply, Installation & Commissioning of 33kV 1500 MVA Switchgears for TRF-1 by dismantling & replacing exisiting switchgear at KEM Hospital RSS
Supply, Installation & Commissioning of 33kV 1500 MVA Switchgears for TRF-1 by dismantling & replacing exisiting switchgear at Colaba RSS
Supply, Installation & Commissioning of 33kV 1500 MVA Switchgears for TRF-1 by dismantling & replacing exisiting switchgear at Nair Hospital RSS
Supply, Installation & Commissioning of 33kV 1500 MVA Switchgears for TRF-1 & 2 by dismantling & replacing exisiting switchgear at Kingsway RSS
Supply, Installation & Commissioning of 33kV 1500 MVA Switchgears for TRF-4 by dismantling & replacing exisiting switchgear at Apollo RSS
Replacement of 11 kV Switchgears at RSS
Supply, Installation & Commissioning of 11kV 350 MVA Bus section Switchgears by dismantling & replacing exisiting Bus section switchgear at Mahim Causeway RSS
Supply, Installation & Commissioning of 11kV 350 MVA Bus section Switchgears by dismantling & replacing exisiting Bus section switchgear at Sion Fort RSS
Supply, Installation & Commissioning of 11kV 350 MVA Bus section Switchgears by dismantling & replacing exisiting Bus section switchgear at Sewree RSS
Supply, Installation & Commissioning of 11kV 350 MVA Bus section Switchgears by dismantling & replacing exisiting Bus section switchgear at Grant Road RSS
Supply, Installation & Commissioning of 11kV 350 MVA Bus section Switchgears by dismantling & replacing exisiting Bus section switchgear at Esplanade RSS
Supply, Installation & Commissioning of 11kV 350 MVA Bus section Switchgears by dismantling & replacing exisiting Bus section switchgear at Malbar Hill RSS
Supply, Installation & Commissioning of 11kV 350 MVA Bus section Switchgears by dismantling & replacing exisiting Bus section switchgear at Dharavi RSS
Supply, Installation & Commissioning of 11kV 350 MVA Bus section Switchgears by dismantling & replacing exisiting Bus section switchgear at Kingsway RSS
Supply, Installation & Commissioning of 11kV 350 MVA Bus section Switchgears by dismantling & replacing exisiting Bus section switchgear at Mahim RSS
Supply, Installation & Commissioning of 11kV 350 MVA Bus section Switchgears by dismantling & replacing exisiting Bus section switchgear at KEM Hospital RSS
Supply, Installation & Commissioning of 11kV 350 MVA Bus section Switchgears by dismantling & replacing exisiting Bus section switchgear at Prabhadevi RSS
Supply, Installation & Commissioning of 11kV 350 MVA Bus section Switchgears by dismantling & replacing exisiting Bus section switchgear at Worli RSS
Supply, Installation & Commissioning of 11kV 350 MVA Bus section Switchgears by dismantling & replacing exisiting Bus section switchgear at Nair Hospital RSS
Supply, Installation & Commissioning of 11kV 350 MVA Bus section Switchgears by dismantling & replacing exisiting Bus section switchgear at Mahalaxmi RSS
Additional / Replacement of Tansformer ( Power Transformer)
Supply, Installation & Commissioning of 16 MVA Power Transformer by dismantling & replacing exisiting 10/12.5 MVA Transformer 1 & 2 at Mazgaon Dock RSS
Supply, Installation & Commissioning of 16 MVA Power Transformer by dismantling & replacing exisiting 10/12.5 MVA Transformer no. 4 at Sitladevi RSS
Supply, Installation & Commissioning of additional 16 MVA Power Transformer at Kingsway RSS
Supply, Installation & Commissioning of 16 MVA Power Transformer by dismantling & replacing exisiting 10/12.5 MVA Transformer 1 & 3 at Sewree RSS
Supply, Installation & Commissioning of 16 MVA Power Transformer by dismantling & replacing exisiting 16 MVA Transformer no. 2 at Sion Fort RSS
Supply, Installation & Commissioning of additional 16 MVA Power Transformer no. 4 at Naval Dockyard RSS
Supply, Installation & Commissioning of 16 MVA Power Transformer by dismantling & replacing exisiting 10/12.5 MVA Transformer no. 1 at KEM RSS
Supply, Installation & Commissioning of 16 MVA Power Transformer by dismantling & replacing exisiting 10/12.5 MVA Transformer 2 & 4 at Bombay Central RSS
Supply, Installation & Commissioning of 16 MVA Power Transformer by dismantling & replacing exisiting 10/12.5 MVA Transformer no. 2 at Kussara RSS
Supply, Installation & Commissioning of 16 MVA Power Transformer by dismantling & replacing exisiting 10/12.5 MVA Transformer 1 & 2 at Mahalaxmi RSS
Supply, Installation & Commissioning of 16 MVA Power Transformer by dismantling & replacing exisiting 10/12.5 MVA Transformer 1,2,3 & 4 at Mahim Causeway RSS
Supply, Installation & Commissioning of 16 MVA Power Transformer by dismantling & replacing exisiting 10/12.5 MVA Transformer 1 & 2 at Naval Dockyard RSS
New Receiving Substation (Excluding Land cost)
Supply, Installation & Commissioning of 16/20 MVA, 33/11 kV (Mineral Oil) at MGM, Dosti, Bharat-Potdar
Supply, Installation & Commissioning of 8/10 MVA, 33/11 kV (Synthetic Ester Oil) at Pimplewadi, aranya north, Aranya South
Related Substation Equipments at RSS as per BOM
Civil Construction & Electrification cost of RSS at 6 no. of RSS ( 1 TRF each)
Repalcement / Additional of 33KV Cables to improve the quality of supply
CABLE MATERIAL
33 kV 3C x 300 sq.mm Cu. XLPE cable
OTHERS
Laying material for 33 kV cable. (R.C.C Tiles)
Pipes.OD 200 mm
JOINTING MATERIAL
33 kV, H.S Type Straight joint XLPE-XLPE (3CX 185 to 300)
Seal for 33KV, (3C185 to 400 ) Cu. XLPE Cable
33V, H.S Type Terminations Kits (3C X185 to 300) XLPE
TRANSPORT
Lorry
CABLE INSTALLATION
Pulling through pipes/ trench.
Excavation, Backfilling and laying 1 cable on Road
JOINT INSTALLATION
33 kV, H.S.Straight joint work. Cu. XLPE
Seal for33KV XLPE Cable
33V, H.S Terminations Kits (185 to 300) Cu XLPE
RAILWAY CROSSING AT 1 SITES
Supply of 600 mm (+5) Casing HDPE Pipes including Transportation/Jointing/Handling etc. at site
Supply of 160 mm HDPE Pipes including Transportation/Jointing/Handling etc. at site
Drilling Bore below the Railway tracks by Horizontal Directional Drilling (HDD) Trenchless Technology.
Laying of HDPE Pipe of 160 mm inside 600 mm (+5) Casing HDPE Pipe
Pulling of LV/HV/EHV Cables through 160 mm HDPE Pipes
Exacavation & Making open Trenches for HDPE Pipes
Supply & Installation of Cable Markers at both ends of Railway Boundaries
Way leave charges paid to Railway Authority per site 2 Crores appromiate per site
Reinstatement charges with multiplying factor 2.0
Replacement of Battery chargers
EQUIPMENTS
Supply, Installation, testing and commissioning of 110V DC BATTERY CHARGERS SUITABLE FOR VRLA BATT CHARGERS as per BEST SPECIFICATION
Dismantling of existing 110V DC BATTERY CHARGERS
Replacement of Battery Sets
EQUIPMENTS
Supply, Installation, testing and commissioning of 110V DC 300AH VRLA BATTERY SETS having 2V/ 56 nos. of Batteries as per BEST SPECIFICATION
Dismantling of existing 110V DC 300AH VRLA BATTERY SETS having 2V/ 56 nos. of Batteries and returning back to designated storage area by BEST
Revamping of existing earthing system at RSS
Earting Revamping as per Bill Of Material
Online Monitoring System for 3 110kv RSS viz Backbay, DBA & Khetwadi of Online DGA Analysis
Online Monitoring System for 110kv RSS Backbay
Online Monitoring System for 110kv RSS Nariman Pt
Online Monitoring System for 110kv RSS DBA
Online Monitoring System for 110kv RSS Khetwadi of Online DGA Analysis
Installation of Power Quality Meters for Transformers (33KV/11 KV)
Supply & Installation of Power Quality Meters for Transformers with software (33KV/11 KV)
LARSEN AND TOUBRO LIMITED
KEI Industries Limited
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid