| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.6 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹20.4 L+₹8,810 (0.43%)Rejected-Finance 40 VISHNU VIHAR KHERAI SHAMSHABAD ROAD KHERAI AGRA UTTAR PRADESH 282001 | AGRA | UTTAR PRADESH | 282001 | L2 | Rejected-Finance Not being lowest | |
| 3 | L3₹21.5 L+₹1.2 L (5.72%)Rejected-Finance PLOT NO 14 SHIV COLONY KATI GHATI RAJGARH ROAD ALWER RAJ | ALWAR | ALWAR | RAJASTHAN | L3 | Rejected-Finance Not being lowest | |
| 4 | L4₹23.4 L+₹3.1 L (15.2%)Rejected-Finance ATLANTIS A2 1501 PLOT NO 05 SECTOR 11 NEAR CLOUD 36 GHANSOLI NAVI MUMBAI 400 701 E 97 CWE SUBS BHANDUP | THANE | MAHARASHTRA | 400701 | L4 | Rejected-Finance Not being lowest | |
| 5 | L5₹23.6 L+₹3.2 L (15.8%)Rejected-Finance | L5 | Rejected-Finance Not being lowest |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
21 Jan 2023, 6:00 pmClosed
GE Army Jaisalmer
GE Army Jaisalmer - 345001
COMPLETION OF INCOMPLETE WORK OF REPAIR AND MAINT OF UNDERGROUND LT CABLE AND ASSOCIATED WORKS AT CERTAIN UNITS AT MIL STN JAISALMER
2022_MES_571130_1
8247/22-23/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Jaisalmer
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE Army Jaisalmer
₹50,000
Yes
28 Feb 2023
24 Dec 2022
23 Jan 2023
24 Dec 2022
21 Jan 2023
7 Jan 2023
Amount
Supply & laying in repair XLPE insulated, screened PVC bedded galvanised steel strip or wire armoured electric power cables (heavy duty) with aluminium conductor 1100 volts grade 50 Sqmm 3.5 Core complete all as specified and directed by Engineer-in-charge.
Supply & laying in repair XLPE insulated, screened PVC bedded galvanised steel strip or wire armoured electric power cables (heavy duty) with aluminium conductor 1100 volts grade 35 Sqmm 3.5 Core complete all as specified and directed by Engineer-in-charge.
Supply & laying in repair XLPE insulated, screened PVC bedded galvanised steel strip or wire armoured electric power cables (heavy duty) with aluminium conductor 1100 volts grade 25 Sqmm 4 Core complete all as specified and directed by Engineer-in-charge.
Supply & laying in repair XLPE insulated, screened PVC bedded galvanised steel strip or wire armoured electric power cables (heavy duty) with aluminium conductor 1100 volts grade 16 Sqmm 4 Core complete all as specified and directed by Engineer-in-charge.
Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, laying of cable/pipe etc or for shafts, wells, cesspits, manholes, pier holes etc not exceeding 10 Sqm on plan and getting out in soft/ disintegrated rock complete all as specified & directed by Engineer-in-Charge.
Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, laying of cable/pipe etc or for shafts, wells, cesspits, manholes, pier holes etc not exceeding 10 Sqm on plan and getting out in hard rock complete all as specified & directed by Engineer-in-Charge. Note (i) Hard rock obtained from excavation shall be stacked properly. Stacked hard rock shall be measured by deducting 50% quantity for voids for hard rock, remaining quantity will be considered of soft/disintegrated rock. (ii) Hard rock obtained shall be issued under Schedule of credit, which shall not be allowed for uses in work.
Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick with soft/ disintegrated rock complete all as specified & directed by Engineer-in-Charge.
Removing excavated material soft/ disintegrated rock to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed by the Engineer-in-Charge.
M&L for sand cushioning to underground PVC/XLPE cable with tibba sand and punning to provide required cover complete all as directed by Engineer-in-charge. (Note :- Punned thickness of sand cushioning shall only measured).
Supplying and laying Jodhpur stone quarry faced stone slab cover 25 to 30 cm in width, 50 to 60 cm long and 40 to 50 mm thick, laid dry and abutting each other with gap between adjacent slab not exceeding 10 mm over under ground cables for protection complete all as specified & directed by Engineer-in-charge.
S&F in repair MCCB, 63 Amps, four pole, 16 KA, 415 volt with fixed thermal maganetic release complete all as specified and directed by Engineer-in-charge. (Note: ICS = ICU 100%).
S&F in repair MCCB, 100 Amps, four pole, 16 KA, 415 volt with fixed thermal maganetic release complete all as specified and directed by Engineer-in-charge. (Note: ICS = ICU 100%).
S&F in repair MCCB, 160 Amps, four pole, 16 KA, 415 volt with fixed thermal maganetic release complete all as specified and directed by Engineer-in-charge. (Note: ICS = ICU 100%).
S&F in repair MCCB, 200 Amps, four pole, 25 KA, 415 volt with fixed thermal maganetic release complete all as specified and directed by Engineer-in-charge. (Note: ICS = ICU 100%).
S&F in repair MCCB, 250 Amps, four pole, 36 KA, 415 volt with fixed thermal maganetic release complete all as specified and directed by Engineer-in-charge. (Note: ICS = ICU 100%).
S&F steel water tubing 40 mm bore, 'light grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors in trench on pole for protection of cable etc and including taking down existing pipe of any description complete all as specified & directed by Engineer-in-charge.
All as per item No. 16 above but size 80mm dia.
All as per item No. 16 above but size 100mm dia.
Labour for felling of tree exc 30 cm and n exc 100 cm girth including cutting of trunk and branches and shacking of serviceable material and disposal of unserviceable material to a distance n exc 50 m and clearing site all as specified and directed by Engineer-in-charge. Note :- Fire wood shall be issued under Sch of Credit.
Taking down old broken cable route indicator of any type etc all as specified and directed.
S & F LT cable route indicator made out of cast iron plate of 150 mm dia 4 mm thick having embosed wiriting LT cable fixed on MS angle iron 30x30x5 mm of 900 mm long with two nuts, bolts and grouting 500 mm length under ground and splitted and bent to shape and embedded in ground with PCC (15 cmx 15cm x 15 cm complete all as specified and directed.
M&L Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of 95 Sqmm complete all as specified and directed by Engineer-in-charge.
M&L Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm complete all as specified and directed by Engineer-in-charge.
Repairing only lights of area security around the Military Station complete with repairing and making it functional to the satisfaction of JE/Engineer-in-charge complete all as specified and directed. Note :-(i) Contractor will bring the printed complaint slip before the commencement of Job. (ii) Arrangement of ladder suitable type for repairing of lights will be the responsibility of contractor & shall deemed into quoted rates.
S&F in repair, galvanised iron bracket of 'medium grade' pipe 40 mm bore, length 1.20m, bend to required shape with 2 Set clamps made of 40x6mm FI and suitable size of bolts, nuts & washers, etc duly painted with two coats of aluminium paint over a coat of red oxide primer complete for fixing street light fittings all as directed by Engineer-in-Charge.
Taking out unserviceable Battery and controller any type all as spcified and directed.
S&F Battery 12 V, 40 AH and controller suitable for solar lighting system complete all as specified and directed by Engineer-in-charge.
Taking out Unserviceable Junction Box for street light of any size complte all as Specified and directed by Engineer-in-charge.
S&F Junction Box for street light made of PVC box including MCB 16 Amps - 01 No and terminal 03 Nos for single phase and neutral on porcelain based insulator with locking arrangement fixed to pole with MS clamps of suitable (20mmx3mm) with nuts, bolts & washer including painting of MS clamp complete all as specified & directed by Engineer-in-charge.
M&L preparation of the old decorated existing external and internal steel surfaces fo feeder pillar boxes/panels/boards of any description and in any position including removal of disintegrated & deteriorated paint either by hand scrapping or by blow stopping as required and applying two coats of synthetic enamelled paint (grey in colour) with using spray machine on old prepared surfaces complete all as specified and directed by Engineer-in-charge.
Dismantling, taking down and removing the old existing unsv non-functional/broken hinges of any description and in any postiion of existing feeder piller boxes/panel boards/feeder pillar boxes etc and supplying and fixing new cold rolled 100mm long medium weight mild steel butt hinges in position with necessary spot welding etc including making necessary adjustment for free and smooth movement of panel and locking arrangements complete all as specified and directed by Engineer-in-charge. (Note : All Hinges fixed in one panel will be considered under one job only).
Taking down or removing of rusted body part/panel door existing LT Panel feeder pillar box of any size and shape, supply, fixing and febrication in existing, shape and size with and including 2 mm thick CRCA sheet and all jointing material such as nuts, bolts or washer and welding etc panel shall be IP-54 protection, complete all as specified and directed by Engineer-in-charge.
NOTE : (i) The panel board repaired shall be made totally enclosed, weather proof/vermin proof for installing incoming/outgoing MCCB/Switch fuses/cable etc complete all as directed. (ii) The rates quoted by the contractor are deemed to be with and including necessary cutting, welding, levelling and jointing etc. as directed to match & accommodate with the existing feeder pillar box/panel board. (iii) The replaced porting shall be painted with two coat of synthetic enameled paint over a coat of red oxide primer. (iv) The rates quoted by the contractor deemed to be with and including dismantling/taking out/removing carefully, any damaged part/portion of the feeder pillar box/panel board as directed.
S&F highly efficient IP 66 and IS 10322/IEC-60598 LED outdoor type LED housing to toughened glass in the front and peanut lense for batwing light distruction with integral electronic constant current driver, PF ≥0.95 and system efficiency ≥100 and CRI≤70 suitable for 60 Wattage complete all as specified and directed by Engineer-in-Charge.
S&F Advance Microcontroller and real time clock base astronomical timer panel suitable for 3 phase 415 V, AC having 8 bit micro controller with in built battery,16 character two line LCD display, input isolator 63 Amp 4 pole and 3 Phase output with 6 Nos 25 Amps MCB SP and with complete copper conductor power wiring inside 2mm (16/18guage) thick feeder panel duly power coated complete with 40X40X5mm 45CM height angle iron structure with PCC complete suitable for 15 KW load complete all as specified and directed by Engr-in-Charge.
M & L for stay assembly comprising of 16 mm dia,1.80 meter long galvanized stay rod,having 7/3.15 mm GI stay wire stranded and 230 mm x 230 mm x 6 mm thick stay plate,complete all as shown on electric plate No.1 of SSR part-I 2009 with and including all necessary fittings/accessories like loop insulators,stay clamps complete all as specified and directed.
S&F lithium based energy efficient integral solar street light of 16 watt in single FRP body with duly polyurenthane coating encases with monocrystalline solar PV panel of 30/35 Wp, Lithium battery 11.1/12.8 Volt, 19.8 Ah withinbuit BMS, IP 65, High brightness W-LED (160-180 lm/Watt) lamp with aluminium reflector for better lighting distribution, CRI 70, colour temperature 5700 K -6500 K, Microcontroller based charge controller cum driver, automatic dimming function with PIR motion sensor, Dusk to dawn operation weight not more than 10-12 Kg with adjustable MS clamp suitable for existing pole/wall mounting etc complete all as specified and directed by Engineer-in-charge. (Note :- Short Circuit, overload, reverse polarity and battery protections to be provided. OEM should provide vital parameters test report from NAB. accredited lab and should be of made in India with CE & TOHS complaint.
S&F in repair, cable 6 sqmm Two core, aluminium conductor, PVC insulated, unsheathed, 1100 volts grade complete all as specified and directed by Engineer-in-Charge.
S&F cable PVC insulated and PVC sheathed 1100 Volt grade copper conductor 2.5 Sqmm 2 Core etc complete all as specified and directed by Engineer-in-Charge.
S.D. And Company
M/s Yash Electrical and Maintenance
M/s Shree Construction Company
M/S BHATI TRADERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .