Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹29.6 CrAccepted-AOC | ₹29.6 Cr | 1 | Accepted-AOC lowest quoted rate |
| 2 | 2₹30.4 CrRejected-AOC | ₹30.4 Cr | 2 | Rejected-AOC higher quoted rate |
| 3 | 3₹35.0 CrRejected-AOC | ₹35.0 Cr | 3 | Rejected-AOC higher quoted rate |
| 4 | Rejected-Technical | - | - | Rejected-Technical Refuse to extend the validity of bid |
| 5 | Rejected-Technical | - | - | Rejected-Technical Not fulfil QC |
Tender Value
₹34.5 Cr
EMD Value
₹69.1 L
Closing Date
28 Oct 2020, 4:00 pmClosed
Additional Chief Engineer WR Zone Jaipur
Sinchai Bhawan, J.L.N. Marg, Jaipur - 302017
Rehabilitation and Improvement Work of Bisalpur Dam under DRIP Phase-II , District Tonk Rajasthan
2020_WRDAS_183828_1
2020_WRDAS_NIT5_BisalpurDrip
Open Tender
Civil Works
1095 days
Deoli
Please refer Tender documents.
3 documents required · 3 mandatory
₹25,000
As per Bid Document
₹69.1 L
Sinchai Bhawan, J.L.N. Marg, Jaipur - 302017
10 Aug 2021
27 May 2020
28 Oct 2020
27 May 2020
28 Oct 2020
9 Jun 2020
27 May 2020 - 9 Jun 2020
9 Jun 2020
Earth work in rough (borrow area) excavation for embankments in hard soil, morrum or highly weathered strata dry or moist, including laying in 20 cm layers (before compaction) and breaking of clods, sorting of grass, pebbles etc. and dressing when compacted by sheep foot roller/pneumatic tyred roller to obtain dry density of at least 98% of Standard Proctor's density with initial lift of 1.5m (Excluding charges for compaction and watering ) including loading and un-loading wherever required complete in all respect. with a lead upto 3 Km
Compaction of earth or highly weathered strata By manually or plain roller. (density 90% of Proctor)
Watering of earth including cost of carriage of water when source of water is up to 1 km
Dry boulder filling in required profile with filling of voids etc. complete including all lead & lifts, and well finished surface
R.R.stone Masonry Kharanja with proper packing of chipping stones using hammer as per IS specification (using R.R. stones where 75% stones to be not less than 15 cm in size in any direction and weighing not less than 23 kg. forfoundation including all leads of all construction materials including curing etc.completein1:6 Cement Mortar
Providing and Laying in position of Cement concrete Nominal mix (1:2:4) including leads of all construction materials, curing, compaction and finishing with rendering in cement sand mortar1:3 (1cement:3coarsesand) and making good the joints excluding the cost of centering, shuttering and reinforcement.Well graded crusher broken stone aggregate of maximum size upto 20 mm
Add Extra for RCC work for Retaining wall, wing wall, returns, divide wall, Pier in above Item No. 6
Dismentalling of CI or asbestos rain water pipe with fitting of clamps including stacking within lead of 50 m, 100mm pipe
Reaming, redrilling and pressure jet flushing of foundation holes of NX size, in the drainage gallery of dam, using diamond drill bit of suitable size, diamond reamer shell with using hydraulically operated rotary core drilling equipments, rods of suitable length to specified depth, fixing PVC pipes with caps, including cost of materials, hire charges of equipments, fuel, labour with all leads and lift etc. complete as directed by Engineer in Charge
Reaming, redrilling and pressure jet flushing of porous holes of 200 mm dia,in the drainage gallery of dam, using diamond drill bit of suitable size, diamond reamer shell with using hydraulically operated rotary core drilling equipments, rods of suitable length to specified depth, fixing PVC pipes with caps, including cost of materials, hire charges of equipments, fuel, labour with al lleads and lift etc. complete as directed by Engineer in Charge
Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard jointed with neat cement slurry mixed with pigment to match the shade of tiles including rubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand).Medium shade using 50% white cement 50% Ordinary cement.
Structural steel work, rivetted, bolted or welded in built up section, trusses and framed work, including cutting, hoisting(height up to 10 m), fixing in position and applying a priming coat of approved steel primer all complete.
Finishing wall with water proofing cement paint of approved brand and manufacture and or required shade to give an even shade including all scaffolding : old work (one or More coat)
Dismentalling tile work in floors and roofs laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 m lead : for thickness of tiles 10 mm to 25 mm
Cleaning drainage gallery, adits, instrumentation galleries etc. by scrubbing/brushing including chiseling and removing leached lime deposit and disposing off all the waste material outside adits in specified location as directed etc., complete with all leads and lifts.
Providing and laying reinforced Cement Concrete grade M30 design mix railing complete as per drawing and technical specification. [MoRTH Specification: 1500,1600&1700] Cast-in-situ
Finishing walls with Acrylic Smooth exterior paint of required shade including all scaffolding : New work (Two or more coat applied @ 1.67 ltr/ 10 sqm over and including base coat of water proofing cement paintapplied @ 2.20 Kg/10 Sqm)
Prepration of surface of existing concrete surface/Masonry in cement mortar including removal of organic deposit by washing, with etching compound and use of wet sand blasting and final washing the surface with air and water jet including cost of all material and equipment required for the work complete.
Add Extra for each subsequent height 3.00 m or part thereof above initial lift of 5 m from ground level (upward or downward) in above Item No. 18
One lift Extra
Two lift Extra
Three lift Extra
37 mm shotcrete is to be applied after removal of defective concrete/masonry, cleaning of surface thoroughly, with compressor having base layer of 12 mm, and second layer of 25 mm thickness in cement concrete (1:2:1) after proper fixing of 9 gauge welded mesh of good quality rust free of size 50 mm x 50 mm with anchors/clamps in stone masonry/concrete complete in all respect. Cement concrete comprising of cement, sand, coarse aggregate, water and quick setting compound in the proportion 1:2:1, sand and coarse aggregate confirming to IS:383 and table No 1 of IS:9012 respectively
Painting exterior surface of wall with 100 % acrylic exterior paint of approved brand and manufacture to give an even shade with two or more coats including preparation of base with sand papering, primer, putty etc complete in all respect : New work
Drilling more than 48 mm but upto 76 mm dia, holes in all types of rock or artificial hard material like concrete or masonry for consolidation / curtain grouting in stages by percussion drilling including cost of drilling equipment, compressed air, water etc. complete and re-drilling in the hole through set grout if required. From Dam Top RL 322.50 m to 297.50 m
Up to 5 m. depth
From 5 to 10 m depth
From 10 to 15 m depth
From 15 to 20 m depth
From 20 to 25 m depth
Normal pressure washing of drilled hole in stages in approved pattern for cleaning of clay, soil and other filler materials from the seams and joints in the foundation rock by establishing connections under pressure with air & water including cost of equipment, accessories compressed air, water, labour, admixtures if any required etc. complete as per specification.
I st Stage
II nd Stage
III rd Stage
IV th Stage
V th Stage
Providing Cement OPC/PPC (in bags) 50 Kg in weight. As per IS:1489 and IS:8112 Excluding cost & empty cement
Grouting of drilled holes minimum 35 mm dia with or without packers with cement/clay and or chemicals (in the form of slurry with water)in prescribed ratio till refusal including cost of grouting equipment, compressed air and water etc. complete but excluding cost of cement, clay and chemicals (only dry weigh to fine gradients excluding chemicals to be considered) with a working pressure upto 15 kg/Cm2 (Dry cement consumption)
Supply of well stitched earth filled bags of capacity, weight not less than 40 kg per bag at site complete.(b) plastic bag
Labour charges for making coffer dam/ring bund (under flowing/stagnate water pool) by loading transporting earth filled cement bags dropping at required locations in water including lead upto 3 km and lift upto 8 meter from NSL complete excluding cost of empty cement bags.
De-watering by pumping all water to maintain desired water level including cost of POL/Power consumption etc complete. 16 to 30 HP
Providing and Laying in position of Cement concrete Nominal mix (1:3:6) including leads of all construction materials, curing, compaction and finishing with rendering in cements and mortar 1:3 (1cement:3coarses and) and making good the joints excluding the cost of cantering, shuttering and reinforcement. Well graded crusher broken stone aggregate of maximum size upto 20 mm
Providing and Laying in position of Cement concrete Design mix M-30 including leads of all construction materials, plasticizers (if required), curing, compaction and finishing with rendering in cement sand mortar 1:3(1 cement:3 coarse sand) and making good the joints excluding the cost of centering, shuttering and reinforcement. Well graded crusher broken stone aggregate of maximum size upto (For mix design Cement content considered 428 kg/ cum of concrete) Aggregate size 20 mm
Excavation including loading unloading disposal and dressing of excavated rock within initial lead of 50m and lift upto 1.5m in dry or moist including dressing of excavated area, de- watering wherever required complete in all respect. Hard rock not requiring blasting
Providing and Laying in position of Cement concrete Nominal mix (1:3:6) including leads of all construction materials, curing, compaction and finishing with rendering in cements and mortar1:3 (1cement:3coarsesand) and making good the joints excluding the cost of centering, shuttering and reinforcement. Well graded crusher broken stone aggregate of maximum size upto 40 mm
Providing and Laying in position of Cement concrete Nominal mix (1:2:4) including leads of all construction materials, curing, compaction and finishing with rendering in cements and mortar1:3 (1cement:3coarsesand) and making good the joints excluding the cost of centering, shuttering and reinforcement. Well graded crusher broken stone aggregate of maximum size upto 20 mm
Supplying of M.S. reinforcement including labour charges for bending binding and placing in position all reinforcement as per drawing including cost of binding wire and all leads and lifts using.Tor or ribbed bars (IS :1786-1985)
Side shuttering including propping etc. complete (to achieve finish F 2 for : Retaining wall, counterfort, abutment, wing walls upstream or down-stream slope facings of dams and open faces of construction joints etc.
Re-handing of excavated material including loading unloading and dressing within initial lead of 50 m and lift of 1.5m with cost of de-watering wherever required and all applicable taxes and levies etc. complete in all respect Mixed Strata Muck
Drilling holes of 35 mm diameter for anchor rods. Upto 1.50 m depth
Excavation including loading, unloading, disposal and dressing of excavated earth with in initial lead of 50 m and lift upto 1.5 m including dressing of excavated area and dewatering wherever required complete in all respect Hard soil mixed with Kankar / boulders, Morrum
Excavation with line drilling, controlled blasting near structures, populated area (situated within 50 m) including dewatering, loading, unloading, disposal & dressing within initial lead of 50 m and lift upto 1.5 m complete in all respect in dry or moist and also including compensation of damages if any , in :(a) Phylite and other hard rock requiring nominal blasting
Providing and Laying in position of Cement concrete Nominal mix (1:2:4) including leads of all construction materials, curing, compaction and finishing with rendering in cement sand mortar1:3 (1 cement :3 coarse sand) and making good the joints excluding the cost of centering, shuttering and reinforcement. Well graded crusher broken stone aggregate of maximum size upto 40 mm
Nominal mix of Plain Cement Concrete well mixed and laid in position using 20% max permissible limit of plums above 160 mm and upto 450 mm, including curing and finishing etc including all leads of all construction materials complete in all respect with well graded crusher broken stone aggregate. The plums shall be distributed evenly and shall be not closer than 150 mm from the surface.PCC Nominal Mix 1:2:4 with Plum (a) Max size of Aggregate 80 mm
Providing and Laying in position of Cement concrete Design mix M-25 including leads of all construction materials, plasticizers (if required) curing, compaction and finishing with rendering in cement sand mortar 1:3 (1 cement:3 coarse sand) and making good the joints excluding the cost of centering, shuttering and reinforcement. Well graded crusher broken stone aggregate of maximum size upto 20 mm
Providing, laying and fixing in position RCC spun or PVC pipe ( 4Kg/Sq cm. as per ISI 4985) with socket including all fittings in required size packed perfectly air tight including 75 mm dia for weep holes
Labour Charges for fixing of anchor bars in neat cement grout including cost of cement and curing etc complete
Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 tonnes vibratory roller, finishing and curing.
Construction of un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with 43 grade cement @ 400 kg per cum, coarse and fine aggregate conforming to IS 383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design, transported to site, laid with a fixed form or slip form paver, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing CC design mix grade M30
Supply & installation of precoated galvanized iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-incharge) 0.50 mm +/- 5% total coated thickness (TCT), Zinc coating 120gsm as per IS: 277 in 240mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by Engineer-incharge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55mm) with EPDM seal or with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead complete upto any pitch in horizontal/ vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm +/- 5% total coated thickness (TCT), Zinc coating 120gsm as per IS: 277 in 240mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws or with polymer coated J or L hooks, bolts and nuts and or G.I. seam bolts and nuts, G.I. plain and bitumen washers complete : Ridges plain (500 - 600mm).
Supplying and fixing of GI chain link fencing of required width in mesh including strengthening with 2 mm dia GI wire/ G.I. staples/G.I.U-nails/ nuts bolts with 2.4 m angle iron posts 50 mm x 50 mm x6 mm placed every 3 metres center to center founded in M15 grade cement concrete 30cm x 30cm x 60cm, 0.6 metre below ground level, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only etc complete as required and as per direction of Engineer-in-charge. Mesh size 150mm x 150mm made of GI wire 3.15mm dia
Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand or manufacture
PART-(i) Oiling and Greasing - Oiling and greasing of Crest radial gates, vertical gates and intake service well gates of Dam including all Charges of man and material complete which include applying Cardium compound to wire ropes, oiling & greasing etc complete As per direction of Engineer-in-charge.
Operation of vertical gates, hoist operation, stop log gates, Gantry Crane, mono rail etc. at Dams for all seasons round the clock whenever required, as per direction of Engineer-in-Charge, by providing skilled & semi skilled staff well conversant with the work of operation of gates as well as meet out all types maintenance & repair work of gates whenever required in any emergency during operation of the gates including deployment of Chowkidar at gate section of the Dam
Oiling and greasing of 500 KVAR generator on Bisalpur Dam Which includes complete removal of old worn out parts, Checking of all copper wiring, all wiring and connections All switches etc complete with all matrial, labour, T&P and lead and lift.
Oiling and greasing of Gantry Crane on Bisalpur Dam Which includes complete removal of all old worn out and broken down parts, cables, connections etc complete Checking of all copper wiring, all wiring and connections Control panel, All switches etc complete with all material, labour, T&P and lead and lift complete in all respect.
PART-(ii) Rubber Seals of Radial Gates - Providing of Rubber Seals as per IS11855 for dams, sluice, canals, barrage, stop log gates etc of required size and type and specifications with testing, including all lead and lifts, packing and forwarding charges for all components etc. complete in all respect
Rubber Seal Z type of Size 120 mm × 76mm x x30mm x 20 mm
Rubber Seal Flat type with corner of Size 130mm × 25mm
Providing High tensile MS Nut Bolts of required size and type, as per specifications with testing, including all lead and lifts, packing & forwarding charges for all components etc. complete.
Labour charges for removal of existing wornout/damaged bottom rubber seal of crest Radial Gates, Vertical Gates and Intake Service Well Gates of Dam by cutting bolts with gas cutter, providing holes in new rubber seal in sertion of sleevs and fixing over gates with nut blots, washer etc including cost of gas (LPG and Oxygen) cylinder etc complete.
Labour Charges for changing of side rubber seals other removing old seal by cutting bolts with gas welding, providing holes in new rubber seal, insertion of sleeves & fixing over gate with nut bolts, washers etc complete including cost of gas cylinder.
Labour charges for changing of brake shoe which include removing of old brake leather shoe by cutting rivets & providing holes in new brake shoe, insertion & fixing in proper position with new rivets complete.
PART - (iii) Painting Downstream of Radial Gate - Cleaning gates/hoists/embedded parts for re-painting by removing rust, oil, paint, grease etc., by using wire brush, scrubber, rust remover and applying a coat of rust inhibitive compound etc., complete.
Providing and applying one coat of Zinc rich epoxy primer paint (zinc content 85%) of approved quality 40 micron dry film thickness to gates/embedded parts/hoist components including cost of all materials, labour, removing rust cleaning surface, scaffolding with all lead and all lifts etc. complete.
Providing and applying two coats of anti corrosive bituminous black paint of approved quality 40 micron dry film thickness each coat to gate components such as horizontal girders/sector and all bracings/trunnion assembly/yoke girders/ stiffeners /footbridge etc. including cost of all materials, labour, removing rust, cleaning surface, scaffolding with all lead and lifts etc
PART-(iv) Epoxy Paint U/S Surface of Radial Gates - Painting of Spillway gates, sluice gates, canal gates (both vertical or radial), stop log gates, exposed embedded parts and all unmachined ferrous surface (hoist cylinders, cylinder heads, hydraulic piping, pipe fittings, bonnet covers), exposed to water as per IS 14177, for which surface preparation by blast cleaning of class "B" primer coat (one coat) of inorganic zinc silicate (preferably air less spray) or alternatively, two coats of zinc rich primer (containing not less than 85% zinc on dry film) to give dry film thickness of 70±5 micron and finish coat (two coats) of solvent less coal tar epoxy paint using air less spray to provide dry film thickness of 150±5 micron per coats. Thus, total dry film thickness of all the coats including primer coating, should not be less than 350 microns, this will be include expenses on mobilisation and demobilisation of equipments. For maintenance painting the surface preparation shall be done by appropriate hand and power tool cleaning, prior to hand power tool cleaning. Any heavy layer of rust should be removed by chipping visible oil, grease, dirt and other foreign material be cleaned using solvents like clean mineral spirits, xylolor white gasoline. After hand and power tool cleaning the surface should be cleaned of loose dust and debris and/or blast cleaned as laid down in Para 7.0 of IS code 14177. After the surface preparation the primer and finishing coats shall be carried out as provided above for painting etc. complete.
Upto 1.50 m Height
Beyond 1.50 m Height
PART-(v) Rubber Seal on Stop Log Gates - Providing Rubber seals as per IS:11855 for Dam sluice, canal, barrage, stop dam etc. gates of required size and type and specifications with testing, including all lead and lifts, packing & forwarding charges for all components etc. complete.
Rubber seal musical note type 100 mmx 44 mm x14 mm (44mm Bulb)Teflon cladded
Rubber seal Flat type 100mm x14mm uncladed
Labour charges for removal of existing wornout/damaged bottom and side rubber seal of Stop Log Gate of Dam by cutting bolts with gas cutter, providing holes in new rubber seal insertion of sleevs and fixing over gates with nut blots, washer etc including cost of gas (LPG and Oxygen) cylinder etc complete
PART-(vi) Wire Ropes of Radial Gates - Providing of dia 40 mm wire rope 6 x 36 construction fibre main core right hand lay ungalvanized with UTS of 180 Kg/Sq.mm breaking strength of 95208 Kgs confirming to IS : 2266/1989
Labour charges for removing old wire rope and fixing of new wire rope with all accessories and T&P etc complete
PART -(vii) Painting the Hoist Bridge - Painting of machinery, including gearing, housing, shafting, bearing, pedestals, oil tanks, control cabinets, hoist beams, pipe support, clamps, ladders etc., of hoists and supporting structures, as per IS 14177, for which surface preparation by blast cleaning of class 'B', primer coat (one coat) of Zinc phosphate paint to give a minimum dry film thickness of 50±5 microns and finish coat (three coats) of aluminium paint or synthetic enamel paint, using air less spray, to provide a dry film thickness of 25±5 microns per coat. Thus, total dry film thickness of all the coats, including primer coat, should not be less than 125 microns. This will include expenses on mobilisation and demobilisation of equipments. For maintenance painting, the surface preparation shall be done by appropriate hand and power tool cleaning. Prior to hand and power tool cleaning, any heavy layer of rust should be removed by chipping. Visible oil, grease, dirt and other foreign material be cleaned using solvents like clean mineral spirits, xylol or white gasoline. After hand and power tool cleaning, the surface should be cleaned of loose dust and debris and/or blast cleaned as laid down in Para 7.0 of IS Code14177. After the surface preparation, the primer and finishing coats shall be carried out as provided above for painting etc. complete.
SITC of silent DG set (As per CPCB Norms) complete with 1500 RPM diesel engine of suitable BHP and AC brushless SPDP alternator mounted on a common base frame and coupled through a flexible coupling or close coupled. Altenator shall be self regulated with standard alternator protection (over voltage, over speed & under Voltage, under speed warning and shut down).Engine shall have residential silencer, upto 3 m exhaust piping, electronic/mechanical governors, manual and electric start, batteries, engine instruments panel, AVM and with weatherproof, powder coated acoustic enclosure for DG set for sound attenuation fabricated from 1.6 mm CRCA sheet steel (Structure) with side wall fabricated from 1.6 mm CRCA sheet and filled with 100 mm thick glass wool(96 Kg/Cum)/Foam, as per IS:8183 the doors of 100 mm thick and fabricated from 1.6 mm CRCA sheet packed with acoustic material, canopy fixed with axial flow fan, All doors/opening are sealed with neoprene/EPDN gasket. The enclosure have built-in fuel tank, residential silencer (isolated from Main DG chamber) with protection and tripping of DG set against temperature of more than 50 degree centigrade. All controls for operation of DG set are from outside the enclosure with DG control panel having microprocessor based Genset monitoring & control system, MCCB, Ammeter, Voltmeter, PF meter, Frequency meter, KWH meter, ind. lamps etc mounted inside enclosure, visible and accessible from outside. The enclosure shall be suitable for following capacity DG set and alternator, noise level shall be less than 75dBA at a distance of 1m, duly certified by authorised agency etc complete in all respect of capacity :Radiator cooled & Turbo charged /AC 500 KVA at 0.80 pf 415 V 50 HZ 3 φ
S/F DG set exhaust piping insulation on 80 mm to 150 mm dia exhaust pipe Asbestos rope insulation
P&F on load change over switch, front handle operated, four pole 415 V confirming to IS:13947 P-III including connections, testings etc as required in the following rating with sheet steel enclosure 1000 A
SITC of high mast lighting system (as per CP3-TR7/1996 of ILE, UK) consisting of totally hot dip galvanised by single dipped method high mast, lantern carriage suitable for up to 12 nos luminaries with welded arm, mast head frame assembly with full cover, aviation obstruction lights, double drum type self sustaining winch, integral power tool accessible from door with padlocking arrangement ( winch motor with control circuit) hot dipped galvanised heavy duty pipe lightening finial, suitable ropes (AISI 316, 7 / 19 construction ), EPR insulated PCP sheathed trailing cable, outdoor type control panel for auto on / off, reverse / forward motor operation and CC foundation of M - 25 grade complete as required. The mast is constructed from mild steel plates (as per IS 5986 Gr. 510 ) cut and folded to form a polygonal section, telescopic jointed and welding as per BS 5135. The complete work shall be supervised and certified by the manufacturers for satisfactory supply, erection, testing and commissioning of high mast. (a) 25 METER HIGH MAST (IN TWO SECTION)(Group I) Material construction: S 355 grade as per BS-EN-10025 Thickness of galvanisation: As per BS EN ISO 1461 Top/Bottom (diameter of high mast): 150/410 Cross-section of mast polygone:20 sides No. of section of mast :03 Thickness of mast: 3mm - 4mm Size of base plate: 730 mm Thickness of base plate: 30 mm No of foundation bolt: 12 nos Bolt dia/length: 30 x 850 mm No. of drum: 02 Wire rope: 2/3 (6mm thick) Power tool: reversible 415V,3 phase (PHILIPS/SURYA/CG/UTKARSH/TRANSRAIL/PE/BPP)
P & F IP-65 protected high power LED flood light system with pressure die cast aluminium housing, toughened glass diffuser with suitable lenses on LED to achieve various beam angles 240 volt, 50hz, of high power LED fixture supplied with pre wired cable of 1 mtr . Integrated driver shell be high efficiency having efficiency more than 85 % and in compliance to IEC standard /BIS certified. the system level luminair efficiency>=100 with high power LEDs of CREE/NICHIA/OSRAM/PHILIPS/SEOUL make is to be used . LED driver input voltage ac 110 to 270 v ac with auto resetting safety cut off . input frequency 50Hz+_3% power factor >0.95 Driver Efficiency >85% control gear integral design THD,1<10% electrical connector must be provided surge protection min.>=5Kinternal and 10KV external 80W onword humidity 10% to 90% RH working temp-20C to 50 c . LED luminaire specification life expectancy equal or more then 50000 buring hrs with minimum 70% lumen maintenance. manufactures word mark name engraved /embossed on die cast housing to allow traceability/ authenticity till life of fixtures shall be CE complained.
High power LED flood light 350 Watts (Group-I)
High power LED flood light 160 Watts (Group-I)
Plate Earthing as per IS:3043 with G.I Earth plate of size 600mm x 600mm x 6.0mm by embodying 3 to 4 mtr. below the ground level with 25 mm dia. G.I. 'B' class watering Pipe including all accessories like nut, bolts, reducer, nipple ,wire meshed funnel, and C.C. finished chamber covered with hinged type with locking arrangement C.I. Cover, C.I. Frame of size 300mm x 300mm complete with alternate layers of salt and coke/charcoal, testing of earth resistance as required.
S & Laying following size earth wire/strip in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection etc. as required. A)20mm x 3mm G.I (Hot dipped)strip
P/Laying P.V.C. / XLPE insulated & P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor of IS:1554 P-I / IS :7098 P - I of Group 1 of approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, IInd class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size. Armoured.
25.0 Sq.mm 3.5 core
10 sqmm 2 core
16 Sqmm 4 core
35 sqmm 3.5 core
16 Sqmm 2 core
25 Sqmm 4 core
Supplying and making end termination with heavy aluminium lugs ( Pin / ring type ) duly crimped with crimping tool, PVC tape etc of following size. a)35.0 Sq.mm
Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor ISI marked (IS:694) of 1.1 kV grade and approved make in existing surface or recessed conduit/casing capping including making connections etc. as required. Group II
2 x 2.50 Sqmm
4 Sqmm 2 core
P&F of removable Voltage surge protection device (surge arrester) for protection against transient over voltage (8/20 micro -seconds) and to run current waves to ground, making connection, testing etc. as required. ( Imax=40 kA, Up= 1.2kV, Uc=275 volts ) (LEGRAND/L&T/GE/ABB/SCHNEIDER/SIEMENS) a) Triple pole & neutral
P&F 240/415 V AC MCB with positive isolation of breaking capacity not less than 10 KA (B/C/D Tripping characteristics) ISI marked IS-8828(1996)/Confirming to IEC 60898 in existing board including making connection etc as required Four Pole MCB 40 A to 63 A Group I
SITC of wall/Free standard floor mounted dust and vermin proof compartmentalised cubical panel made out of CRAC sheet required hardware duly treated for derusting in 7 tank process with dephosphating and with power coating on both side of panel in desired shade. The panel having PU/Neoprene rubber gasket not less the 3 mm thickness ,separate detachable gland plate MS base channel, hinged door with locking arrangement for equipment/switch gear thickness of sheet shall not be less than 1.6 mm up to 600 mm length/width of any compartment and be of 2.00 mm above 600 mm. Load bearing structure shall be of 2.0 mm. Thick sheet supported by base MS channel if required. Side wall and cable alley compartment having bolted type doors with/without detachable extension type structure. Group II
SITC of quick make and quick break four pole current limiting MCCB having following current rating short circuit breaking capacity at 440/415 V, 50 HZ O/L and S/C setting and confirming to IS:60947-2/IEC 60947-2, with front face and centralised adjustable line load interchangability having positive isolation capability provision for UVR, shunt trip earth fault trip, push to trip including making connection with lugs and spreaders as required :with thermal magnetic release upto 100 Amp, 25 KA, adjustable O/L and fixed S/C setting Lcs=100 % ICU
P&F mechanical/digital time switch having following day/weak programme and minimum 100 Hrs reserve and AC I Rating of 16-20 Amp including making connections, programming etc as required : one day weak reserve digital type
P&F of AC operated heavy duty 230/440 V power contactor confirming to IS:13947-4-1/IEC:947-4-1 having provision of mechanical interlocking, auxiliary contact, Din rail mounting type including making connection pasting etc required: 4 pole power contactor with AC I rating 100 Amp
Cement concrete for plain/reinforced concrete in open foundation as per drawing and technical specification. [MoRTH Specification : Section 1700(N)&1500(N)]. Using Batching Plant, Transit Mixture, and Concrete Pump. P.C.C.M-15 grade
Octagonal MS Poles made of S-355JO grade steel sheet, folded lengthwise to obtained octagonal shape, having single longitudinal seam weld and hot dipped galvanised internally & externally in accordance with IS 2629. (See Table E - 10 for specs.):
Supply, Erection and fixing of hot dipped galvanised Overhang (48.3 x 3.25 mm) with cap (400 x 88.9 / 114.3 x 3.25 mm) over the existing poles: Single Arm overhang
Single Arm Overhang
Double Arm overhang
P & F 240/415 V isolator conforming to IS: 13947-III/IEC 60947-3 on existing board / sheet including making connections, testing etc. as required:
Four pole Isolator 63 A rating
Double pole Isolator 63 A rating
P & F 240/415 V AC MCB with positive isolation of breaking capacity not less than 10 KA (B/C / D tripping characteristic) ISI marked IS 8828 (1996)] / conforming to IEC 60898 in existing board / Sheets including making connections, testing etc. as required: 6 A to 32 A rating
4 pole Power contactors with following AC 1 rating: 200 /250 Amp
SITC of quick make and quick break 4 Pole current limiting MCCB having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings and conforming to IS 60947-2/IEC 60947-2 with front face and centralised adjustable, line load interchangeability, having positive isolation capability, provision for UVR, shunt trip, earth fault trip, push (test) to trip, including making connections with lugs & spreaders, etc as required : Upto 200 Amp, 25/35 kA, adjustable O/L & fixing S/C setting, Ics = 100% Icu
Supply, installation, Testing and Commissioning of IP-65/ROHS/CE compliant Integrated Solar Street Light fixture having die cast Aluminium body with integrated monocrystaline solar PV panel with lithiumILiFeP04) ferro Phosphate battery and compliant to MNRE specification s / BIS approved .luminaire specification s / BIS approved .luminaire minimum 40000 hrs. rated Lamp life with LED's brand of Philips/0sram/Nichi a/CreelSeoul and driver efficiency should be > 850/o , CRI Microcontroller based high efficiency controller cum driver designed with automatic dimming function with PIR motion sensor t full power lighting motion sensor t full power lighting when a human move in the sensor when a human move in the sensor range and only 300/o lighting when a human move out ) , Dusk to Down operation, working temperature t-l 10oC to [+) 55oC, with adjustable clamp 10oC to [+) 55oC, with adjustable clamp suitable for pole/wall mounting complete in all respect with protection like short circuit, overload, reverse like short circuit, overload, reverse coverage must be 1,20 Degree or greater complete as required. Compact Solar LED Street Light-60 Wpfmono)l9v /12.8 V 27 AH/40 w
Providing/Laying of Epoxy concrete aggregate (1:1.5:4), one part Epoxy Mix (Dobeckot 505C+EH 411 ), 1.5 part quartz sand no10 and 4 part of aggregate of 20 to 10 mm size by weight in a lift of 10 to 15 cm thick.
Providing laying XLPE insulated IS:7098/II/85 of group 1 of approved make H.T. Cable for working voltage 11 KV Earthed direct in ground including excavation of 30 cm x 100 cm size trench, 25 cm layer of sand, II nd class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc as required of size 3 core 300 Sq mm
Providing and making heat shrinkable type outdoor/indoor through terminations/joints kit of group 1 and approved make suitable for XLPE insulated 11/33 KV cable, with required components, preparation of cable ends, testing etc as required of following size : 11KV End termination kit outdoor type 3 core 240/300 Sq mm
Maintenance free gel earthing with pipe in pipe/pipe in strip technology filled with anti corrosive conductive compound (CPRI Tested) below the ground in 150-200 mm dia earth pit and surrounding filled with required mineral filling compound (MFC should be hygroscopic property to retain the moisture for long time to create low resistance zone) and CC finished chamber covered with hinged type with locking arrangement CI cover, CI frame of size 300 mm x 300 mm complete testing of earth resistance as required of following sizes: GI pipe 3000 mm long 80/40 mm, terminal 14 mm GI strip
S&L following size earth/wire strip in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connections etc as required : 25 mm x 5 mm copper strip.
Providing laying P.V.C./XLPE insulated and P.V.C. sheathed cable of 1.1 Kv grade with copper conductor of IS: 1554 P-1/IS:7098 P-1 of group 1 of approved make in ground as per IS:1255 including excavation of 30 cm x 75 cm size trench, 25 cm thick under layer of sand, II nd class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc as required.
Armoured Cable 35 Sqmm 4 core
Armoured Cable 25 Sqmm 4 core
Armoured Cable 10 Sqmm 4 core
Armoured Cable 4 Sqmm 4 core
Armoured Cable 2.5 Sqmm 2 core
Armoured Cable 2.5 Sqmm 10 core
Armoured Cable 2.5 Sqmm 3 core
Providing laying P.V.C./XLPE insulated and P.V.C. sheathed cable of 1.1 Kv grade with aluminium conductor of IS: 1554 P-1/IS:7098 P-1 of group 1 of approved make in ground as per IS:1255 including excavation of 30 cm x 75 cm size trench, 25 cm thick under layer of sand, II nd class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc as required. 185 sqmm 3.50 Core 185 sqmm 3.50 Core
P&F of AC operated heavy duty 230/440 Volts power contactor confirming to IS:13947-4-1/IEC:947-4-1 having provisions of mechanical interlocking, auxiliary contacts, Din Rail mounting type including making connections, testing etc as required: 4 pole power contactors with following AC 1 rating of 160 Amp
SITC of copper wound transformer conforming to IS:2026 & losses as per Discom's CTL (CTL test certificate to be attached) of rating 11/0.433 Kv delta star connected, vector group Dyn 11, standard accessories like conservator, silica gel breather, radiators, fins, HT brushing and LT cable boxes, of - LTC(+/- 5% in steps of 2.50 %) winding temperature rise of 50/55 C, ISI marked drain valve, dial type temperature gauge, first fill of oil, epoxy based paint, including carrying of pre commission testing & charging of transformer (see table - 08 for CTL losses) : 63 KVA
Providing and fixing of Pre-cast concrete interlocking blocks og 60 mm thick manufactured from fully computerized automatic stationary hydraulic vibro pressed machine and full computerized automatic batching plant of class as per IS:15658-2006.The CC interlocking paving blocks be laid on average 50 mm thick bed of course sand and the joint is to be filled with fine sand. Laying procedure on compacted sub base as defined. The work includes earth work in cutting of B/T road, cutting of WBM road and disposable of unserviceable material with all lead and lift and stacking of serviceable material complete job is to be executed as per the instruction of Engineer-in-charge. The rates are inclusive of all lead, lift and taxes. General specification of blocks: 60 mm thick, light traffic category, M35 grade designation block.
Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches by sandla/loi
Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade including all scaffolding :Two or more coats on new work including preparation of base and primer, putty, lippy etc complete in all respect
Painting steel work with deluxe multi surface paint to give an even shade two or more coat applied @0.90 lit./10 sqm over and under coat of primer applied @ 0.80 lit/10 sqm of approved brand or manufacture.
French spirit polishing :One or more coats on old work.
Providing and fixing 1st quality Vitrified porcelain Polished tiles on floor, skirting and steps etc in different sizes (Thickness to be specified by manufacturer) with water absorption less than or equal to 0.08% confirming to IS : 15622 of approved make in all colour and shade laid with 20mm thick CM 1:4 including grouting the joints with white cement and matching pigment etc complete Size 600mm x 600mm
Finishing walls with Acrylic Smooth exterior paint of required shade including all scaffolding : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/ 10 sqm).
Stone tile work for wall lining upto 10 m height with special adhesive 8mm thick (mirror polished and machine cut edge) Granite stone of any colour and shade. over 12mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement with an admixture of pigment to match the stone shade.
Laying of lawns including ploughing levelling breaking of clods manuring & removal of stones etc. (Cost of manure of extra good earth to be paid separately) Maintenance of lawns for 30 days of more till the grass forms a thick lawns free from weeds & fit for. In rows 15 Cms. apart in either direction
Supplying and stacking good earth at site complete including loading unloading & transportation etc.
Supply and planting following in poly bags / earthen pots well branched, well established & free from disease of 600 mm min. eight shurbs at site in 0.45 m dia holes, 0.45 m deep dug in the ground, mixing the soil with decayed farm yard/sludge manure, backfilling the hole watering etc as required. Phonenix sylvertris ( Date Palm)
Providing and laying in position cement concrete including curing, compaction etc complete in specified grade excluding the cost of centering and shuttering - All work upto plinth level M-10 Grade nominal mix aggregate 20 mm.
P&F energy efficient direct fit (retrofit) LED tube system with integral deiver, on existing fixtures. Power consumption of 18 W/36 W 1500-3000 lumen, system lumen efficiency 80 lm/watt output, life time of 50000 burning hours with 70 % initial lumen maintained. CCT 3000 K.4000 K and 6000 K 4' LED tube shape fixture 18 W
Providing and fixing of uPVC casement fully open-able windows (outward / inward) manufactured in ISO 9001:2000 & 14001:2004 certified company. Frame : Made from the Extruded uPVC Window Profile Section of size 60 x 60mm having outer wall thickness of 2.25mm (+/- 0.2mm) and 3 box multi-chamber construction, White in finish, duly reinforced with 1.2mm thick G/J/U/O TYPE GI section. All the four corners shall be mitered cut & thermal welded so as to form window frame. Frame shall be milled with drain and air equalizer hole in order to be water tight and for drainage of accumulated water, if any, to outer side. Fix Mullion made of 76 x 60mm uPVC Profile Section with steel reinforcement shall be provided in windows having 2 or more openable shutters, as per the requirement. Frame shall have ‘O’ type EPDM gasket fitted in in-built groove of frame profile for proper air & sound insulation of the shutter. Shutter : The shutter of outward openable window shall be made of size 78 x 60mm and shutter of inward openable window shall be made of size 73 x 60mm Extruded 3 box multi-chamber uPVC Window Profile Section of white colour having outer wall thickness of 2.25mm (+/- 0.2mm) provided with reinforcement of 1.2mm thick G/J/U/O TYPE GI section duly mitered cut & thermal welded at all corners and fitted with uPVC glazing bead of size 34 x 20mm with ‘K’ & ‘O’ type inner and outer EPDM weather seal gaskets alongwith 5mm thick ISI make plain float glass. All welding joints of frame and shutter shall be cleaned and milled with the CNC mechanism to provide uniform grooved finish on all visible joints. Hardware : Window shutters are fixed with frame on 2.5mm thick SS301 Grade Friction Hinge System to keep the window opened at desired angle. Friction Hinge also enables easy cleaning of glass on both side from the inside of building. Locking of windows is provided with multi-point transmission gear (ESPAG) with white finish powder-coated handle. Installation at Site : Complete window is to be installed on site with 10 x 100mm fastners with white cap in existing pre-finished wall cut-out cemented to glass level plane at all height & width and silicon glue is applied to fill up the crevices between wall and window frame. Complete in all respect as per the drawing and specifications and direction of engineer-in-charge.
P&F white vitreous china double syphonic European WC (IS:2556 Mark) with mounted WVC flushing cistern (IS: 2556 Mark) of 10 liters capacity complete with all necessary internal fittings including cutting and making good the wall and floors (ISI Marked with superior quality of approved make)
Providing and fixing external grade boards ,solid core single leaf flush door sutters IS : 2202-67 marked using phenol formal dehydreresin glue both sides with approved steel fittings complete as per annexure 'A' 35 mm thick commercial veneer both side .
P & L in position cement concrete including curing , compaction etc. complete in specified grade excluding the cost of centering and shuttering -All work in superstructure . 1 : 1.5 : 3(1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
P&F PVC storage tank confirming to (IS : 12701 marked indicating BIS license no.) standards of approved make with cover ,25 mm dia 1 mm long GI overflow pipe & 25 cm. long wash out pipe with plug & socket ,including making connection etc. complete of approved design , 500 litre capacity
Providing and fixing Granite stone slab mirror polished and machine edge cut in walls, pillars, steps, Shelves, Sills Counters, Floors etc. laid on 12mm (Av.) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) jointing with white cement mortar 1:2 (1white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete. Green/Black up to 1500 Sq cm.
P&F early steamer emission type lightening arrester on GI mast with air terminal configured as spheroid which is comprised of separate electrically isolated 4 panels surrounding an earthed centralfinial, the terminal shall be tested by CPRI for impulse current of 45 KA (8/20 Sec)with 5 positive and 5 negative impulse, the arrester having following protection radius at level 1 : 60-79 m
S& laying of down conductor of 70 Sqmm single core insulated flexible copper cable with accessories as required.
Contactor Block ML-2, 32 Ampere, AC-3, 415 Volts, 50 HZ, ISI-3947, EC60947-4-1 for gallery.
Providing and installing ON/OFF switch of control panel of radial gates.
Providing and installing BCH thermal relay MC 305, ANN-3N series A-22-0, 30 Ampere for gallery
Providing and installing Chavi switch of control panel of radial gates.
Providing and installing limit switch housing roller level 3SE100E of siemens or equivalent make for radial gate.
Providing and installing magnet coil 415 V - 440V, 50 ampere, 4 wires
Providing and installing magnet coil 415 V - 440V, 50 ampere, 2 wires
Providing and installing HT fuse wire
Providing and installing HRC fuse 63 ampere
Providing and installing timer coil 2 wire
Providing and installing timer coil 4 wire
Providing and installing Magnet Brake coil for radial gates 440 Volts 40 Amp
Providing and installing rotary switch AMP meter type 14 S 39 A for gallery
Providing and installing Amperemeter range 60/5A size 4"
P&F two pin energy efficient compact fluorescent lamp in existing holders /fixtures as required : 36 watts 4 pin
Providing and installing BCH thermal relay MC 305, ANN-3N series A-22-0, 30 Ampere for gallery
Providing and fixing leather washer of diameter 6"
Providing and installing Diesel Filter for generator
Providing and installing air Filter for generator
Providing and installing rotary switch 440V for generator
Providing and installing rotary switch AMP meter type 14 S 39 A for gallery
Providing and installing Timer set complete for gallery
Providing and installing Shut down Valve for generator
Providing and installing BCH Thermal relay 0-30 Ampere for generator
Providing and installing BCH 32 ampere contactor coil 440 V for generator
Providing and installing temperature switch
Providing and installing limit switch 220 Volts Siemens' or equivalent make
Providing and installing main switch 100 Ampere 440 Volts
P/Laying P.V.C. / XLPE insulated & P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor of IS:1554 P-I / IS :7098 P - I of Group 1 of approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, IInd class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size. (RALLISON/DELTON/HAVELLS/KEI/TEREXAL/PLAZA/POLYCAB/RAJSAFE) 10 Sqmm 4 Core
P & F IP-65 / IP-66 protected LED street light luminaire on existing bracket. Fixture made from powder coated single piece pressure die cast aluminium housing with Heat dissipation fins on housing with High Power LEDs of CREE / NICHIA / OSRAM / PHILIPS make. Diffuser / Glass cover for ensuring IP65 protection for Lamp & control gear compartment, System Lumen output of 1500 - 8500 High Power LED. Integrated Driver shall be high efficiency having efficiency > 85% and in compliance to IEC standards System life of 25,000 Burning Hours with 70% of initial Lumens maintained. Fixture shall be in CE Compliance. IP - 65 Protected LED Street Light Luminaire LED Street Light fixture 80-90 Watt
VUB ENGINEERING PVT.LTD.
MANDA DEVELOPERS AND BUILDERS PVT LTD
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid