| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.3 LAccepted-AOC FLAT NO 10 S NO 98 PLAT NO 78 SAI SAYAJI PARK A RIGHT BHUSARI COLONY KOTHRUD PUNE 411 038 | PUNE | MAHARASHTRA | 411038 | L1 | Accepted-AOC L1 | |
| 2 | L2₹15.4 L+₹10,830 (0.71%)Rejected-Finance GALI BAWARI WALI NOHARIA BAZAAR SIRSA 125055 HARYANA | SIRSA | HARYANA | 125055 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹15.7 L+₹45,181.60 (2.96%)Rejected-Finance CC III 28A JANTA BHAWAN ROAD SIRSA HARYANA 125055 | SIRSA | HARYANA | 125055 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹16.0 L+₹70,242 (4.60%)Rejected-Finance H NO 2049 HANUMAN COLONY NEAR TCP 3 HISAR CANTT PIN 125006 HARYANA | HISAR | HARYANA | 125006 | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹18.8 L+₹3.5 L (23.0%)Rejected-Finance | L5 | Rejected-Finance Other than L1 |
Tender Value
₹16 L
EMD Value
₹32,000
Closing Date
19 Jun 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Sirsa
GE (AF) Sirsa-125055
Repair and Cleaning of Sewage Line, Septic Tank, Soakage Well Manholes in Pocket-01 and 02 of Domestic Area at AF Stn Sirsa
2023_MES_598136_1
GE/SRA/T-08/2023-24
Open Tender
Miscellaneous Works
Item Rate
210 days
GE (AF) Sirsa
Please Refer Tender Documents
8 documents required · 8 mandatory
₹500
GE (AF) Sirsa
₹32,000
Yes
22 Jul 2023
27 May 2023
20 Jun 2023
27 May 2023
19 Jun 2023
6 Jun 2023
29 May 2023 - 1 Jun 2023
Amount
M&L Removing Complaint of Blockage (viz Blockage in Bath, Kitchen, WC & Drainage in Traps/Line from Trap to 1st Manhole, Cleaning of Manhole) by deploying Trades Mens as per Stipulated Time Frame from 9.00 AM to 5.00 PM and maintaining proper Records of COMPLETED and PENDING Complaints including updating status of Complaints through SMS/Manually for DOMESTIC AREA and ZHOPRA COMPLEX of AF STATION SIRSA, complete all as specified and as directed. NOTE : (a) If the Complaint is not attended/removed within a Day the Recovery will be levied on the Contractor for non-complelion of the Complaint at the Rate of Recovery included in Tender Document here-in-after. (b) It is mandatory on the Part of Contractor to deploy minimum 02 No. of Safaiwala/Mazdoor with requisite T&P throughout the Entire Contract Period. However required manpower and T&P, if required more to meet the requirement as mentioned in BOQ Item is also to be arranged by the Contractor at his own Arrangements and Cost. Quoted Rates shall be deemed to include this factor and nothing Extra will be admissible on this account other than Quoted Rates for BOQ Item. In case of any dispute on this factor, the decision of Accepting Officer shall be final, conclusive and binding.
M&L for Cleaning of Choked Sewer Lines of size 100mm Dia but not exc 150mm dia at any depth, Manually and Making Sewer Line Functional complete including Working Under Foul Condition and depositing the sludge, rubbish, etc. off the Premises outside the MOD/AF Land or Sewage Treatment Plant, complete all as specified and as directed. NOTE : (a) If the Complaint is not attended within a Day the Recovery will be levied on the Contractor for non-complelion of the Complaint at the rate of recovery included in Tender document here-in-after. (b) It is mandatory on the Part of Contractor to deploy minimum 6 No. of Safaiwala/Mazdoor with requisite T&P throughout the Entire Contract Period. However required manpower and T & P, if required more to meet the requirement as mentioned in Item is also to be arranged by the Contractor at his own Arrangements and Cost. Quoted Rates shall be deemed to include this factor and nothing Extra will be admissible on this account other than Quoted Rates for Item. In case of any dispute on this factor, the decision of Accepting Officer shall be final, conclusive and binding.
All as per Item No. 02 above but for cleaning of sewage line of size 200 mm dia but not exc 250 mm dia
M&L Removing Manhole Cover and Desludging/Desilting/ Cleaning of existing Manholes of depth exc 1.00M but not exc 3.00M filled with Sludge by means of Mechanical Appliances complete, Working Under Foul Condition and resetting the Manholes Cover in same Position and depositing and removal of Sludge, Rubbish, etc. off the Premises Outside Defence Land, complete all as specified and as directed.
Cleaning of Manhole chamber of any size, upto depth 1.0 metre each, manually, removing muck/sludge/silt/mud, liquid etc under any position including foul condition and cleaning the inlet and outlet with water, placing back the manhole cover in position and disposing off the sludge/debris out of MOD land complete all as specified and directed.
M&L Dewatering Sludge from Soakage Wells by Pumping out as required to keep the Complete Sewage System in order and as to avoid any Over flowing of Sewage Water including removing of Soak Well water pumped out as such out side of Defence Land by means of Pumps and Tankers (Capacity of Water Tanker shall be 5000 Litres) as required including Operating and Supervisory Staff(s) so as to keep the whole Station area Pollution Free, complete all as specified and as directed. NOTE : In/out register for tanker should be updated at the Guard Room by the contractor and signature of securtiy Guard and contractor are mandatory for payment of the item.
M&L Desilting/Cleaning of Septic Tank and the like including Sludge Water and Solids Mechanically by HCV Mounted Suction Discharge Machine having Blow Back Facility with Sludge Tank and disposal of the same to Outside of MD/AF Land, complete all as specified and as directed. NOTE : Disilting/Cleaning of Septic Tanks shall be done for TWICE in the entire Contract Period.
Demolition Cement Concrete (reinforced) of any description (above or below Ground Level) and removing debris, etc. to Outside of MD/AF Land, complete all as specified and as directed.
M&L Reinforced Cement Concrete 1:2:4 (20mm graded stone aggregate) in Bands, etc., finished Even and Smooth without using Extra Cement, complete all as specified and as directed. NOTE : Formwork & Reinforcement will be Measured and Paid separately under relevant Items.
M&L Reinforced Cement Concrete 1:2:4 (20mm graded stone aggregate) in Slabs supported on Walls, etc., finished Even and Smooth without using Extra Cement, complete all as specified and as directed. NOTE : Formwork & Reinforcement will be Measured and Paid separately under relevant Items.
M&L for Use and Waste of Formwork to Soffits of Suspended Slab and similar work not exc. 200mm thick, Fair Finished surfaces, complete all as specified and as directed.
M&L Use and Waste of Formwork in Curve to edges of Concrete, Sides of RCC/PCC Bands in Walls, horizontal or sloping, and similar work, complete all as specified and as directed.
M&L Pre-cast Reinforced Cement Concrete 1:2:4 (20mm graded stone aggregate) in Slabs, Manhole Cover Slabs, etc., set in Cement Mortar 1:4, with necessary formwork including dismantling and removal of damaged precast slabs etc complete all as specified and as directed. NOTE : Reinforcement will be Measured and Paid separately under relevant Item.
M&L TMT Bars 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for Columns, hooking Ends and binding with and including Mild Steel Wire (annealed) not less than 0.90 mm dia, complete all as specified and as directed.
M&L TMT Bars 6.0mm to 8.0mm dia, cut to length, bent to shape required including cranking, bending spirally for hooping for Columns, hooking Ends and binding with and including Mild Steel Wire (annealed) not less than 0.90 mm dia, complete all as specified and as directed.
Demolition Brick work built in Cement Mortar and in any Position including all Quoins, Arches and Pillars, etc. And removal of debris from site complete all as specified and as directed.
M&L for Brick Work with Fly-Ash Bricks (Old Size Bricks), Straight or Curved on Plan exc. 6.0 Metre mean Radius, built in Cement Mortar 1:6, complete all as specified and as directed.
Taking down Cement Plaster including Raking out Joints, Hacking for Key, Scrubbing down with Water and removing debris, etc. to Outside of MD/AF Land, complete all as specified and as directed.
M&L for 15 mm thick plastering in two layers, 10 mm + 5 mm in cement mortar 1:4, top layer of 5 mm thickness mixed with with water proofing compound (as per manufacturer's instructions) on brick/stone walls or concrete surfaces finished even and fair (upto any height) for external surfaces complete all as specified and directed. Note : Water Proofing compound shall be measured and paid seperately as "Supply only".
Supply only Integral Water Proofing compound, conforming to IS and as approved, complete all as specified.
Demolition & breaking up Drain Pipe 150mm dia (Salt Glazed Ware, AC or Reinforced Concrete) set in Cement Mortar, complete all as specified and as directed.
Supply and laying Reinforced Concrete Pipes 150mm (internal dia), Class NP-3, laid in Trenches on Concrete Bed, to required Slope, jointed with jute & cement mortar 1:1, complete with collars all specified and as directed.
M&L Cement Concrete 1:3:6 (40mm graded stone aggregate) as in Concrete Bed to Drain Pipes of 150mm bore (dia), including packing under, and haunching against the sides of pipes after they are laid and tested complete all as specified and as directed.
M&L Cement Concrete 1:3:6 (40mm graded stone aggregate) as in Bed to Drain Pipes of 150mm bore (dia), including Packing Under and Completely Surrounding Pipes with Concrete after they are laid and tested; complete all as specified and as directed.
Excavating Over Areas not exc. 1.50 Metre deep and getting out in Soft/Loose Soil, complete all as specified and as directed.
Excavating Over Areas exc. 1.50 Metre but not exc. 3.00 Metre deep and getting out in Soft/Loose Soil, complete all as specified and as directed.
Excavating Over Areas exc. 3.00 Metre but not exc. 4.50 Metre deep and getting out in Soft/Loose Soil, complete all as specified and as directed.
Excavating in Trenches, not exc. 1.50 Metre wide and not exc. 1.50 Metre in depth; for Foundation, etc. or for Shafts, Wells, Cesspits, Manholes, Pier Holes, etc. not exc. 10 Sqm on Plan and not exc. 1.50 Metre in depth and getting out in Soft/Loose Soil, complete all as specified and as directed.
Returning, filling in approved Soft/Loose Soil including spreading leveling, watering and well ramming in layers not exc. 25 Cm thick, complete all as specified and as directed.
Removing Excavated Materials (Soils) not exc. 50.00 Metre and depositing where directed at a level not exc. 1.50 Metre above the Starting Point including spreading over ground, complete all as specified and as directed.
M&L Loose Filling with Aggregates of gauge 80mm to 150mm (Broken Bricks) in Soakage Pits, Soakage Wells, etc., complete all as specified and as directed.
S&F PVC (SWR) 75mm bore (dia) Soil, Waste and Ventilating Pipe, single socketed, in any length with PVC Joints, with or without Ears, fixed to Walls, and fixed-in-repairs Complete all as specified and as directed.
S&F PVC (SWR) 110mm bore (dia) Soil, Waste and Ventilating Pipe, single socketed, in any length with PVC Joints, with or without Ears, fixed to Walls and fixed-in-repairs complete all as specified and as directed.
S&F PVC (SWR) Bends (any radius), Diminishing Pieces or Tapers (larger bore measured) Fittings for PVC (SWR) Pipe 75mm bore (dia), jointing with Solvent Cement and fixed, complete all as specified and as directed.
S&F PVC (SWR) Bends (any radius), Diminishing Pieces or Tapers (larger bore measured) Fittings for PVC (SWR) Pipe 110mm bore (dia), jointing with Solvent Cement and fixed, complete all as specified and as directed.
M&L Stack Clamp for Pipe 75mm/110mm/150mm bore (dia), made out of Flat Iron 50x5mm and 16mm dia Round Iron Stay including Bolts and Nuts and securing Ends of Stays to Wall or Roof and Fixed-in-repairs, complete all as specified and as directed.
M&L Cutting into existing Manholes for Connecting New Drain Pipes of 150mm (Internal dia), Making Good to Pipe and rendering, cutting out existing Benching for and forming Branch Channel (½ Round or ¾ Section) in Cement Concrete 1:2:4 (20mm graded stone aggregate), Smooth Finished and Reforming Benching as required, complete all as specified and as directed.
Desilting/Taking out Brick Bats, Pebbles, Silts, Muds, Clay etc from bottom of Drains including Cleaning Grasses, Vegitation, etc, depth upto 3.00 Metre including removing excavated materials from the sides of Drain including removing RCC drain cover and refixing after cleaning of drain and removing debris to outside MD/AF Land where directed, complete all as specified and as directed.
YESH BUILDERS
M/s Satguru Traders
STAR CONSTRUCTIONS
YOGINDER KUMAR GUPTA AND COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .