| 1 | L1₹9.8 LAccepted-AOC | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹9.9 L+₹7,869 (0.80%)Rejected-Finance NO 6 BAJANAI KOIL CROSS STREET CHATHIRAM PATTABIRAM CHENNAI 600 072 | CHENNAI | CHENNAI | TAMIL NADU | 600072 | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹12.7 L+₹2.9 L (29.9%)Rejected-Finance | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹12.8 L+₹3.0 L (30.2%)Rejected-Finance OLD NO 191 NEW NO 616 M T H ROAD PATTABIRAM CHENNAI 600 072 | CHENNAI | CHENNAI | TAMIL NADU | 600072 | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹13.6 L+₹3.8 L (38.3%)Rejected-Finance PLOT NO 1A INDIRA NAGAR AGARAM ROAD SELAIYUR CHENNAI 600073 | CHENNAI | CHENGALPATTU | TAMIL NADU | 600073 | L5 | Rejected-Finance Not Lowest |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
23 Dec 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE I RD AVADI
AGE I RD AVADI pin 600054
CLEANING AND MAINTENANCE OF SEWAGE SYSTEM IN RESIDENTIAL AREA AT CVRDE AVADI
2023_MES_629002_1
8607/E8
Open Tender
Civil Works
Item Rate
330 days
AVADI
As per Tender Documents
8 documents required · 8 mandatory
₹500
AGE I RD AVADI
₹30,000
Yes
19 Jan 2024
20 Nov 2023
25 Dec 2023
20 Nov 2023
23 Dec 2023
4 Dec 2023
Amount
Carry out the rectifications of blockage/soakage etc in sewage system such as sewage line, septic tank, Manholes GT anfd FT etc by using suitable manual/mechanical devices in liquid and foul position as on demand received/directed by Engineer in charge with sufficient manpower and keep entire sewage system free from blockage/ soakage complete all as directed The brief scope of work consists of following:-
Note for item No 1
Cleaning of blocked / soaked manholes of any depth including removal of obstructed particles/dirt etc., and washing wall/floors surfaces with fresh water including removing and re-fixing the existing manhole cover slab/ inlet and outlet pipes without damage etc. The quoted rate deems to include for working in foul condition.
Roding the existing blocked/soaked sewage pipe line of any diameter between manholes/septic tank etc and removing all foreign materials and sludge completely from the pipe line and making serviceable for free flow of sewage system.
Cleaning of blocked / soaked gully trap, Nahani trap and Floor trap etc including removal of sludge and washing with fresh water and refixing the existing lid of the trap without any damage.
The blockage/soakage shall be rectified on priority on receipt of complaints on same day. If any delay in completion, penalty will be effected at Rs 100/- each complaint.
The man engaged should be capable for attending minor defects/rectification. Necessary tools should be provided by the contractor without any extra cost as deemed fit. Necessary safety devices such as mask, cloves etc to be provided to the labour while working.
Necessary weekly off shall be provided by the contractor to each service provider as per labour Act at his own arrangements. Nothing extra shall admissible in this regard
All safety measures shall be arranged by the contractor as per law followed by State/ Central Govt.
Pumping out sludge including water from the soak pit / septic tank/Manholes depth not covered above Item No.1.etc. mechanically by using tipper with tanker and non clog sewage pump set arrangement including foot valve, necessary draining out pipe etc and removing all foreign materials, sludge, water including cleaning the soak pit/ septic tank/ manholes etc complete all as specified and directed by Engineer-in-Charge.
Note : (a) The sludge removed shall be taken outside MD land for disposal and disposed as agreed by local body ie, Municipality etc, and when removed from the soak pit/septic tank/manholes. The cost of disposal shall be inclusive of the unit rate quoted by the tenderers under this item. No extra cost on this account is admissible. (b) Pumping shall be carried out in the presence of MES representative. (c) The quoted rate deems to include for working in foul condition.
Cutting down plants/trees of girth n.exc 15cm from roof tops/sides external walls of bldgs chajjas wall junctions incl taking out possible quantities of roots entered in wall/slab surfaces and making good the surfaces and cleaning the roof surface. shall be carried out using PCC (1:2:4) type'B' or cement mortar 1:2) all as specified and as directed by Engineer-In-Charge.
Demolition and breaking of drain pipes of internal dia 100/150/200mm/400mm (SGSW) or CI set in cement mortar all as specified and as directed by Engineer-In-Charge.
S&F DWC ID Pipes SN 4 pipe (HDPE Black) drain pipes laid in trenches and jointed in Cement solvent int dia 100 mm all as specified and as directed by Engineer-In-Charge.
S&F DWC ID Pipes SN 4 pipe (HDPE Black) drain pipes laid in trenches and jointed in Cement solvent int dia 150 mm all as specified and as directed by Engineer-In-Charge.
S&F Salt-glazed stone ware drain pipes laid in treanches and jointed in CM (1:1) of internal dia 100 mm all as specified and as directed by Engineer-In-Charge.
M&L for salt glazed stone (SGSW) ware drain pipes laid in trenches and jointed as specified dia of pipe 150mm all as specified and as directed by Engineer-In-Charge.
M&L for Reinforced cement concrete hume pipes, class NP3, 200mm dia bore laid and jointed complete with collars and tested Complete all as specified and as directed by Engineer-in-Charge.
M&L for Reinforced cement concrete hume pipes, class NP3, 400mm dia bore laid and jointed complete with collars and tested Complete all as specified and as directed by Engineer-in-Charge.
M&L for Cement concrete Type C-2 (1:3:6) concrete bed to drain pipe for 100 mm bore of pipe including packing under and hunching against the sides of pipe after they are laid and tested in all as specified and as directed by Engineer-In-Charge.
M&L for Cement concrete C-2 (1:3:6) concrete bed to drain pipe for 150 mm bore of pipe including packing under and hunching against the sides of pipe after they are laid and tested in all as specified and as directed by Engineer-In-Charge.
M&L for Cement concrete Type D-2 (1:4:8) concrete bed to drain pipe for 200 mm bore of pipe including packing under and hunching against the sides of pipe after they are laid and tested in all as specified and as directed by Engineer-In-Charge.
Cutting into existing manholes/soak well for connecting new drains, making good to pipe and rendering, cuting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required all as specified and as directed by Engineer-In-Charge.
Demolition of Reniforced Cement concrete (reinforeced) of any description and in any position not otherwise specifically provided for inculing cutting of reniforcement to facilate demolition all as specified and as directed by Engineer-In-Charge.
M&L for precast re-inforced cement concrete type B1, 1:2:4 (using 20mm graded agg in RCC manholes cover all as specified and as directed by Engineer-In-Charge.
M&L for TMT bars 8mm dia and over cut to length bend to shape reqd incl crancking and incl mild steel wire (annealed) not less than 0.9mm dia all as specified and as directed by Engineer-In-Charge.
Demolition of brick work built in cement mortar in existing manholes, septic tank etc all as specified and as directed by Engineer-In-Charge.
M&L for Brick works built in CM 1:4 with sub class `B' Bricks straight or curved on plain complete for Manholes all as specified and as directed by Engineer-In-Charge.
M&L for Brickwork with sub class ‘B’ bricks in one brick thick honey comb walling, built in CM 1:4 all as specified and as directed by Engineer-In-Charge.
M&L for Rendering in CM 1:4, 15mm thick on fair faces of brick work or cement concrete surfaces and finished even and smooth without using extra cement all as specified and as directed by Engineer-In-Charge.
M& L for PCC Type C-1, (1:3:6)(using 20 mm graded aggregate) as coping all as specified and as directed by Engineer-In-Charge.
Supply only Integral waterproofing compound all as specified and as directed by Engineer-In-Charge.
S&F PVC SWR pipe single socketed (Bore of pipe in 75 mm.) in any length with rubber ring joints fixed to wall for soil waste incl taking down of old pipe all as specified and as directed by Engineer-In-Charge.
S&F PVC SWR pipe single socketed (Bore of pipe in 110 mm.) in any length with rubber ring joints fixed to wall for soil waste incl taking down of old pipe all as specified and as directed by Engineer-In-Charge.
M&L PVC(SWR) bends in 75mm dia any radius all as specified and as directed by Engineer-In-Charge.
S&F PVC (SWR) junction single, (Single T) equal or unequal for Bore of pipe in 75 mm all as specified and as directed by Engineer-In-Charge.
S&F PVC (SWR) junction single, (Single T) equal or unequal for Bore of pipe in 110 mm all as specified and as directed by Engineer-In-Charge.
M&L for excavation in trenches in hard/dense soil not exceeding 1.5 m wide and not exc 1.5 m in depth for foundation of man holes or shafts etc not exc 10 Sqm on plan & n.exc 1.5 m depth and getting out in hard/ dense soil all as specified and as directed by Engineer-In-Charge.
-Ditto- All as per ser Item No 29 here in before but for each additional 1.5m or part thereof in depth beyond the first 1.5 m all as specified and as directed by Engineer-In-Charge.
Returning fiflling hard and dence soil in incl spreading levelling watering and well ramming in layers n exe 25 cm complete all as directed by Engr -in -charge.
Removing excavated material not exc 500 M and dipositing where directed at a level not exc 1.5m above the starting point etc complete all as specified and as directed by Engr -in -charge.
Demolition of cement concrete of any description and in any position not otherwise specifically provided for all as specified and as directed by Engineer-In-Charge.
M&L for broken stone Hardcore of gauge n.exc 63mm, deposited, spread and levelled in layers n.exc 15cm thick, watered and rammed to a true surface all as specified and as directed by Engineer-In-Charge.
M & L for 150 mm thick PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as in sub base including use and waste of form work all as specified and as directed by Engineer-In-Charge.
M&L for 150mm thick PCC 1:2:4 (using 40mm graded stone aggregates) as in paving /hardstanding/road cutting including necessary use and waste of form work and finish surfaces with spike rolling to surfaces or making impression of expanded metal whilst concrete is in green positionall all as specified and as directed by Engineer-In-Charge.
SHRI BALAJI CONSTRUCTIONS
silambarasan
SUBAMAGENCYANDCONSTRUCTION
SHREECHAKRACONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .