| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.7 LAccepted-AOC AT ITI CHHAK PO TALCHER DIST ANGUL PIN 759100 | ANUGUL | ODISHA | 759100 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹3.5 L+₹75,879.56 (27.8%)Rejected-Finance AK PO GHANTAPADA TALCHER ANGUL ODISHA | TALCHER | ANGUL | ODISHA | L2 | Rejected-Finance Rejected being L2 | |
| 3 | L3₹3.8 L+₹1.1 L (38.9%)Rejected-Finance AT PO HANUMANPUR DIST ANGUL ODISHA 759117 | ANUGUL | ODISHA | 759117 | L3 | Rejected-Finance Rejected being L3 |
Tender Value
₹5.1 L
EMD Value
₹6,300
Closing Date
6 Sept 2024, 5:00 pmClosed
BD Behera, Staff Officer (EnM)
BISWODHAR BEHERA, STAFF OFFICER (E AND M), OFFICE OF THE GENERAL MANAGER, MCL, TALCHER AREA, P.O. - DERA COLLIERY, DIST- ANGUL (ODISHA), PIN - 759103 PHONE. NO. 06760-269463 MOB- 9438879866 MAHANADI COALFIELDS LIMITED, TALCHER AREA
Reformation and Renovation of Colony Sub Station No.07 for Installation of One additional Transformer for Separate power Supply to the Auditorium of Talcher Colliery.
2024_MCL_315708_1
GM(TA)/SO(EnM)/e-13,Date 22.08.2024
Open Tender
Electrical and Maintenance Works
Item Rate
45 days
Talcher Colliery
Please refer Tender documents.
4 documents required · 4 mandatory
₹6,300
26 Oct 2024
27 Aug 2024
9 Sept 2024
28 Aug 2024
6 Sept 2024
28 Aug 2024
28 Aug 2024 - 2 Sept 2024
Amount
PART-A Providing fixing of One GOAB switch 11 KV grade Horizontal Type double break 800 Amps with all accessories as required.
Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminum conductor cable of 11 KV grade as required: 120 Sqmm
Providing & fixing of One H.G Fuse Set 11 KV grade Two Post Insulator Horizontal Type 800 Amps with all accessories as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. Up to 120 Sqmm
Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Providing & Fixing 25 mm X 5 mm G.I. strip on Ground over recess for connection etc. as required.
Providing & fixing following rating and breaking capacity and pole of MCCB with thermo magnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel making connections etc. as required 630A, 50KA FP MCCB.
PART-B Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. all kinds of soil.
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
Brick work with Fly Ash Brick (230x115x75 mm size) bricks of class designation 10 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand)
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Providing and fixing precoated galvanized iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester topcoat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length up to 12 meter or as desired by Engineer- in-charge. The sheet shall be fixed using self-drilling /self-tapping screws of size (5.5x 55 mm) with EPDM seal, complete up to any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Providing and fixing precoated galvanized steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester topcoat 15-18 microns using self-drilling/ self-tapping screws complete Ridges plain (500 - 600mm)
Extra for providing and fixing wind ties of 40x 6 mm flat iron section.
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
Finishing of 12 mm Cement plaster of mix 1:6 (1 cement: 6 coarse sand)
Total impact of GST plus Labour Cess [@ 1 % (BOCW Cess to be deducted from the RA bill as per the value of the work progress)] for the purpose of CTC
SANJAY KUMAR SINGH
ART ENGINEERING
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .