Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹20.9 LAccepted-AOC | 1 | Accepted-AOC accepted being L1 | |
| 2 | 2₹25.2 L+₹2.5 L (11.1%)Rejected-Finance WZ 1000 B NANGAL RAYA PANKHA ROAD NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | 2 | Rejected-Finance Rejected being not L1 | |
| 3 | 3₹25.7 L+₹3.0 L (13.1%)Rejected-Finance | 3 | Rejected-Finance Rejected being not L1 | |
| 4 | 4₹26.6 L+₹3.9 L (17.2%)Rejected-Finance 1 225 5 6 SADAR BAZAR DELHI CANTT 110010 | DELHI CANTT | NEW DELHI | DELHI | 110010 | 4 | Rejected-Finance Rejected being not L1 | |
| 5 | 5₹30.1 L+₹7.3 L (32.3%)Rejected-Finance NO 9 BYRAVESHWARA INDUSTRIAL ESTATE ANDRAHALLI MAIN ROAD NEAR PEENYA 2ND STAGE BENGALURU 560 091 | BENGALURU URBAN | KARNATAKA | 560091 | 5 | Rejected-Finance Rejected being not L1 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
25 Sept 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE UTILITY ELEC SUPPLY
GE UTILITY ELEC SUPPLY DELHI CANTT
REPAIR MAINTENANCE AND REROUTING OF LT CABLES AND CONNECTED ITEMS AT 105 TA 1 WEC EETSU DAS POLO GROUND TODAPUR KHANDHAR LINE EME WORKSHOP LORRY ROAD PUMP HOUSE RR COLONY BARAR SQUARE WEE WKSP NODAL PUMP HOUSE I 19 PF BD COY AND ADJOINING
2024_MES_671359_1
GE ELEC/D-48/2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE UTILITY ELEC SUPPLY
AS PER TENDER DOCUMENT
7 documents required · 7 mandatory
₹500
GE UTILITY ELEC SUPPLY
₹90,000
Yes
30 Oct 2024
4 Sept 2024
26 Sept 2024
4 Sept 2024
25 Sept 2024
18 Sept 2024
Amount
Excavation in trenches not exc. 1.5 m wide and not exc 1.5 mtr deep in soft loose soil for laying / taking up/ taking down of cables and getting out and levelling of bottom suface to required level complete all as specified and directed by Engineer- in- Charge.
Returning filling in,. Including spreading, levelling,. Watering and well ramming soil in layers not exceeding 25 cm thick complete all as specified and directed by Engineer- in- Charge.
Removing excavated material (ie soil) from site to a distance n. exc 50 mtrs away and depositing where directed at a level n. exc. 1.5 mtr above the starting point complete all as specified and directed by Engineer- in- Charge.
Material and labour for river washed and screened, dry sand for filling in trenches below and around underground cables for cushioning of cables etc,complete all as specified and directed by Engineer- in- Charge.
Supply & laying sub class B bricks having minimum compressive strength 75 Kg/ Sqcm laid in trenches for cable protection etc complete all as directed by Engineer-in-Charge.
All as per srl item No 5 here-in-before but using old bricks obtained under srl item No 1.00 here in before complete all as specified and directed by Engineer- in- Charge.
Supplying, laying, jointing testing and connecting in replacement XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with multistranded aluminum conductors, IS 7098 marked, suitable for LT 1100 Volt system, laid in trenches fixed to pole, including jointing & testing complete all as specified and directed of following sizes:- Note :- Excavation, earth work ,cable protection , sand fillings , cable joint shall be measured and paid separately under respective items of schedule.
16 Sqmm 4 core
25 Sqmm 3.5 core
35 Sq mm 3.5 core.
50 Sq mm 3.5 core.
70 Sqmm 3.5 core
95 Sqmm 3.5 core
120 Sqmm 3.5 core
185 Sqmm 3.5 core
240 Sqmm 3.5 core
300 Sqmm 3.5 core
400 Sqmm single core
Boring of hole under road/pavement/hard standing or any other situation by mannual means and suitable for passing of GI pipe 40 to 100 mm bore and making good both ends complete all as specified and directed by Engineer- in- Charge.
Supply & Fixing in replacement GI Pipe (light grade) with necessary accessories/ fittings for cable protections/pole for crossing of culverts/nallah of following bore sizes complete all as specified and directed by Engineer- in- Charge.
Supply, fixing and testing straight through joint heat shrinkable type with jointing kit suitable for cable PVC/XLPE insulated armoured heavy duty aluminium conductor 1100 Volts grade complete all as directed for the following sizes :-
25-50 Sqmm x 3.5 core/ 4 core
70-150 Sqmm x 3.5 core
185 -240 Sqmm x 3.5 core
Supply and fixing in renewal of Analog Time switch , 240 Volt AC , 50 Hz , mounted on any type/description LT panel/feeder pillar/wall after taking down old existing un serviceable time switch complete all as specified and directed by Engineer- in- Charge.
Taking down unservicable RCC/ steel tubular poles of any type and supply & installing steel tubular swaged poles type 410 SP-31 (9 mtr long) of approx wt.147 kg conforming to IS 2713 (Part-II) including excavation, earth work, PCC foundation, base plate,PCC coping,GI pipe for cable protection etc. and GI bracket for fitting mounting,inclusing two runs of PVC insulated 1100V multi-stranded copper wire of size 2.5 Sqmm from the junction box to the fitting complete all as per manufacturer's instructions and complete all as specified and directed by Engineer- in- Charge. NOTE:- The unit rate in this item is deemed to be included the cost of exacavation and earth work in any type of soil,PCC foundation 1:4:8 type D-2 , PCC coping 1:2:4 type B-1 as in steel tubular pole and GI bracket made of GI pipe medium grade 40 mm bore, 1.5 mtr long for fixing of street light fitings . The steel pole shall be painted by bituminious paint total length inside and up to planting depth outside and remaining portion of pole painted with two coat of aluminium paint over a coat of red oxide complete all as specified and directed.
Earthing in replacement complete with galvanized steel earth plate electrode of size 60cmx60cmx6 mm thick, buried directly in ground (earth pit not less than 2.10 m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level, connected to galvanized iron strip 32x6mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel as shown in electrical plate No 3 of SSR Part I, connected to earth test point and the equipment on the other nuts and washers of galvanised ironside complete all as specified, including testing and commissioning complete all as directed. Note : (a) The unit rates quoted against this item shall be deemed to include the cost of excavation and earth work in any type of soil, common salt & charcoal dust in alternate layers, PCC 1:3:6 as in pit, precast RCC 1:2:4 type B-1 with necessary reinforcement as in cover & frame for pit, funnel, watering pipe 20 mm bore GI pipe light grade, protection pipe 40 mm bore GI pipe medium grade etc. (b) The quoted rates shall also deemed to include the cost of earth test point and earth strip/GI lead wire and protection pipe upto 7.5 meter beyond the earth plates electrode.
Supply, installing, testing and commissioning in replacement of factory made and tested (including CPRI type tested certified panel) LT Panel board ,cubical compartmentalized , out door type double door , mounted on angle iron legs 50x50x6mm thick, suitable for 415 volts, 3 phase, 4 wire, 50 HZ AC supply system accomodated with 01 No ACB 4 pole, 800 Amp, 50 KA, 415 Volt AC Horizontal draw out type motorized, front operated with Micro processor based LCD protection release for adjustable over current, short circuit and earth fault protection fitted with aluminium bus bar link 1200 Amps for incomming and outgoing cable connection. The panel shall be dust and vermin proof. IP-65 class protection and shell be made of 3.15 mm CRCA MS sheet, and 50x50x6mm thick MS angle iron frame work, powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coats of red oxide primer, front and rear opening type, with apron for cable entry closing locking arrangement . including excavation, earth work and platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed sotne aggregate on top and grouting bolts etc for panel. The platform shall be such that it is of a height 45 cm above the nearest road level.
S&F in replacement KIOSK box wheather proof including made out of one piece mounted SMC base and door pole mounted hinged door size 333x233x120mm out side and 300x200x105mm inside dimensions comprising of aluminium bus bar 4 strips for 3 phase and neutral 63 Amps including embossing/painting of danger notice of size not less than 10cm x 7.5cm with letters, figures and conventional skull and bones in signal red colour on front face of KIOSK box body complete all as specified and directed by Engineer- in- Charge. Incluiding MS clamp of size 25x3 mm with suitable size nut,bolts & washer.
Material and labour for re-painting of LT Panels/feeder pillars of approx size 2 to 4 Sqm with 2 coats of super enamal paint over a coat of red-oxide with sparygun including writing of feeder pillar numbers in appropriate size of letters complete all as specified and directed by Engineer- in- Charge.
All as per item No 16.00 above but of approx size upto 1.90 Sqm complete all as specified and directed by Engineer- in- Charge.
MMaterial and labour for re-painting of LT Steel tubular poles of any sizes with apply of 2 coats of aluminium paint including rubbing with wire brush/emery paper & writing pole Nos in appropriate size of letters including making yellow and black strips upto height of 1.5 mtr above from ground level complete all as specified and directed by Engineer- in- Charge.
Taking down unservicable RCC/ steel tubular poles of any type and supply & installing steel tubular swan neck pole type 410 SP-31 (9 mtr long) complete with mild steel base plate, finial taper plug, bolts, nuts and screws including two coats of aluminium painting over a coat of primer for exposed surfaces and two coats of bituminous black paint over a coat of primer to the surfaces in contact with concrete inclusing two runs of PVC insulated 1100V multi-stranded copper wire of size 2.5 Sqmm from the junction box to the fitting complete all as specified and directed by Engineer- in- Charge. Note :- The unit rate in this item is deemed to be included the cost oif exacavation and earth work in any type of soil,PCC foundation 1:4:8 type D-2 , PCC coping 1:2:4 type B-1 as in steel tubular pole and GI bracket made of GI pipe medium grade 40 mm bore, 1.5 mtr long for fixing of street light fitings . The steel pole shall be painted by bituminious paint total lenth inside and up to planting depth outside
Supply and fixing in replacement of outdoor type wall mounted bus bar chamber having 04 pole bus bar of rating 63 Amps fitted with MCCB 63 Amps 4 Pole, 16 KA, 50 HZ as incomer inclding suitable hole in bus bar for outgoing cable connection including suitable size nut bolt and fastener complete all as specified and directed by Engineer- in- Charge.
Supply & Fixing of stranded aluminium conductor cable PVC sheathed unarmoured , 1100 Volts , flat twin core of following sizes:-
Supply and fixing in replacement of LED street light fittings capacity 60 Watt LED street light complete all as specified and directed by Engineer- in- Charge.
Supply & Fixing On load change over switchopen execution of capacity 250 Amps , 4 pole , 415 volt , 50 Hz mounted on wall with fastner and suitable size of nut and bolts after taking down old existing un serviceable MCCB/SDFU etc complete all as specified and directed by Engineer- in- Charge.
Supply & Fixing in replacement of UNSV /Burnt MCCBs of capacity 630 Amps, FP, 50 KA, 415 Volts 50 Hz, AC, with thermal and magnetic release fixed in any type of existing LT panel/Feeder piller including taking out old existing unserviceable MCCB from panels etc complete all as specified and directed by Engineer- in- Charge.
Description all as per sel item No 24.00, above but rating of MCCB 63 Amp,FP, 25 KA complete all as specified and directed by Engineer- in- Charge.
Material & labour in replacement for Retro Reflective installation sign board of size 12 Feet x 4 Feet using 3 mm ACP sheet duly riveted / fixed on fabricated stainless steel 304 grade finished hollow section of size 25mm x 50mm with supporting ss strips in base at a height of 7.5 meter above ground level on stainless steel 304 grade pipe of size 80mm embedded 90 CM in PCC 1:2:4 type B 1 block of size 45cmx45cmx90cm including necessary excavation and earth work . The board shall be machine printed and the front of the ACP shall be overall sheathed with blue colour base adhesive tape. The writing matter shall be in English language on both side using reflective adhesive Painter tapes as directed. The size and letters and matter to be printed shall be finalized by Engr-in-Charge.
Material & Labour for cutting and removing grass, vegetation bushes etc from surrounding of installation/LT Panel/LT ACB panel and removing all rubbish to a distance not exceeding 50 m complete all as specified and directed by Engineer- in- Charge.
Supplying and fixing in replacement LED flood light fitting of following size complete all as specified and directed by Engr-in-charge :-
Supply only Hexa frame complete all as specified and directed by Engr-in-charge.
Supply only Hexa blade of suitable size complete all as specified and directed by Engineer- in- Charge.
Supply only thiner for cleaning of panels /bus bar/ timer panel etc complete all as specified and directed by Engineer- in- Charge.
Supply only duster cloth for cleaning of panels /bus bar chamber / timer panel/transformer etc complete all as specified and directed by Engineer- in- Charge.
Supply only Rubber/cotton Hand gloves electricals having insulation upto 33 KV complete all as specified and directed by Engineer- in- Charge.
Supply & Fixing in replacement bracket for street light fitting complete with 2.2 mtr long 50mm dia GI pipe medium grade and including necessary mild steel clamp , nuts,bolts and wahsers and painting on steel surfaces with two coats of aluminium paint complete all as specified and directed by Engineer- in- Charge.
Supply and Installation of LT CT operated Trivector Meter with the following specifications:- (a) Meter Type: LT 3 Phase 4 Wire Electronic Tri vector Meter (b) Standard: IS 13779:1999 / CBIP 88 (c) Accuracy: Class 0.5 (d) Voltage and Current rating:- (i) Reference Voltage - 3x240 V (ii) Basic Current (Ib) - 5 A (iii) Maximum continuous current (Imax) - 10 A (e) Rated Frequency (variation) - 50Hz (±5%) (f) Power consumption:- (i) Voltage circuit: Less than 1.5 W and 10 VA per Phase at reference voltage, reference temperature and reference frequency (ii) Current circuit: Less than 1 VA per phase at basic current, reference frequency and reference temperature (g) Display type: 8 digit 7 segment backlit LCD display, not less than10 mm character height (h) Display in the event of Power Failure: Internal battery back-up for LCD display (j)Communication port: (i) Galvanically isolated Optical Communication port for data transfer through either CMRI or remote device or both is provided (ii) RS 485 for DLMS protocol (iii) Energy recording - Unidirectional
Supply only in replacement of old unserviceable Blower having volumetric flow rate 4 to 5 cum/min, 230 Volt , 50 Hz, complete all as specified and directed by Engineer- in- Charge.
Supply & Fixing in replacement MS angle iron, flat,Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers,welding, bending cold or hot,drilling holes for bolts, in any shape or size as indicated or complete all as specified and directed by Engineer- in- Charge.
Supply & Fixing in replacement 3.15mm dia MS wire 75x75mm mesh , made up into mattress or cages appx 2.00 mtr height and fixed with flate iron /angle by welding in position complete all as specified and directed by Engineer- in- Charge.
Material & Labour for 2 coat of synthetic enamel painting over a coat of red oxide to MS wire fencing including preparation of old surface complete all as specified and directed by Engineer- in- Charge.
Note : contractor should procure and provide 50 % of the material as listed above within 15 days of the placing of work order and shall be verified by the Engr-in-charge
mayur enterprises (BID ID -3102325)
Rajindera Enterprises (BID ID -3109922)
M P TYAGI ENGINEERS AND CONTRACTORS (BID ID -3110379)
Vijay Electricals (BID ID -3110669)
Ridhi engineers and builders (BID ID -3112491)
MV Engineers And Contractors (BID ID -3103700)
DS CONSTRUCTION (BID ID -3109435)
Microsys Controls India (BID ID -3112856)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .