| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.5 LAccepted-AOC 17 1A BALLYGUNGE CIRCULAR ROAD KOLKATA 700 019 | KOLKATA | WEST BENGAL | 700019 | L1 | Accepted-AOC Quoted Lowest Rates | |
| 2 | L2₹15.0 L+₹25,080 (1.71%)Rejected-Finance 72 A ABINASH CHANDRA BANERJEE LANE KOLKATA 700010 | KOLKATA | WEST BENGAL | 700010 | L2 | Rejected-Finance Quoted Higher Rates |
Tender Value
₹15.1 L
EMD Value
₹30,200
Closing Date
3 Feb 2020, 6:00 pmClosed
MAJ WABLE NARESH DEVRAM GE I CG P KOLKATA
DAMODAR COMPLEX GARDEN REACH ROAD KOLKATA 23
REPAIR / REPLACEMENT OF EXTERNAL ELECTRIC SUPPLY, ALLIED WORKS AND DG SETS AND EQUIPMENTS INSTALLED AT DIFFERENT LOCATIONS AT INS NETAJI SUBHAS UNDER GE (I) (CGP) KOLKATA
2020_MES_312591_1
8820/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
KOLKATA
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE I CG P KOLKATA
₹30,200
Yes
2 May 2020
7 Jan 2020
5 Feb 2020
7 Jan 2020
3 Feb 2020
21 Jan 2020
Amount
Repair to lead acid battery 12V of DG sets including replacement all brass terminal end, connecting assembly, replacing distilled water, cleaning, charging testing complete all as specified and directed.
S&F Asbestos rope 10 mm dia for suitable for exhaust pipe of DG Set complete including taking down old unserviceable one complete all as specified and directed .
S&F MS exhaust pipe of size 100mm dia with coupling and flange (approx length 2.5m) suitable for DG Set including welding and grinding work incl taking down old one complete all as specified and as directed.
M&L wiring for Diesel Engine set,(30 KVA to 125 KVA capacity) by 6.0sqmm (Nominal area) single core PVC insulated stranded unsheathed FRLS copper conductor cable 1100 V grade (total approx length of wire 30mtr) drawn through appropiate sleev/cover and proper size of copper lug/themble complete fixed to proper clamping complete all as specified and directed.
M&L tank cleaning for Diesel Engine set,(30 KVA to 125 KVA capacity) and reassembling the same and reconnection to the fuel supply pipe line, testing after reconnection complete all as specified and directed. (NOTE :- cost of reqd item involved shall be deemed to be included in the unit rate quoted).
Repair / overhauling and servicing of Diesel Engine set for fire fighting pump / Generator set of capacity 110KVA/125KVA/ 90BHP AC 3 phase 415 Volts 50 HZ 0.8 PF 1500 RPM Make : Kirloskar by (a) Dismantling and shifting of Diesel Engine from existing position and re-installing and commissioning in the same position after repair.(b) Dismantling the complete Diesel Engine part by part and cleaning thoroughly by degreasing and de-carbonising all the rotary and static parts. (c) De sludging de-carbonising & degreasing of all the parts / components such as PT Pump, Hydraulic Governer, Terbocharger, Water pump etc and also checking of all rotary and stationery parts of DG set for smooth functioning of engine, adjusting the pressure regulate valve settings and carryingout calibration by complete checking, aligning with fuel pump control system and re-assembling after repair / replacement of unserviceable parts including greasing as required and testing complete all as as specified and directed. (Note:- Spare required Shall be measured and paid as supply only under respective items in this schedule)
Supply only hose set suitable for engine of capacity 110KVA/125KVA/ 90BHP, AC 3 phase 415 Volts 50 HZ 0.8 PF 1800 RPM
Supply only valve set(12 Nos) suitable for engine of capacity 110KVA/125KVA/ 90BHP AC 3 phase 415 Volts 50 HZ 0.8 PF 1500 RPM
Supply only valve guide(12 Nos) suitable for engine of capacity 110KVA/125KVA/ 90BHP AC 3 phase 415 Volts 50 HZ 0.8 PF 1500 RPM
Supply only valve clamp with 'O' ring set suitable for engine of capacity 110KVA/125KVA/ 90BHP AC 3 phase 415 Volts 50 HZ 0.8 PF 1500 RPM
Supply only head gasket suitable for engine of capacity 110KVA/125KVA/ 90BHP AC 3 phase 415 Volts 50 HZ 0.8 PF 1500 RPM
Supply only lub oil & water jacket rubber 'O' ring set suitable for engine of capacity 110KVA/125KVA/ 90BHP AC 3 phase 415 Volts 50 HZ 0.8 PF 1500 RPM
Supply only valve spring(12 Nos) suitable for engine of capacity 110KVA/125KVA/ 90BHP AC 3 phase 415 Volts 50 HZ 0.8 PF 1500 RPM
Supply only piston ring(6Nos) set suitable for engine of capacity 110KVA/125KVA/ 90BHP AC 3 phase 415 Volts 50 HZ 0.8 PF 1500 RPM
Supply only begeam bearing(C.R. Bearing) set suitable for engine of capacity 110KVA/125KVA/ 90BHP AC 3 phase 415 Volts 50 HZ 0.8 PF 1500 RPM
Supply only main bearing(as per sample) set suitable for engine of capacity 110KVA/125KVA/ 90BHP AC 3 phase 415 Volts 50 HZ 0.8 PF 1500 RPM
Supply only gasket joint(as per sample) set suitable for engine of capacity 110KVA/125KVA/ 90BHP AC 3 phase 415 Volts 50 HZ 0.8 PF 1500 RPM
Supply only fan belt(B-45) suitable for engine of capacity 110KVA/125KVA/ 90BHP AC 3 phase 415 Volts 50 HZ 0.8 PF 1500 RPM
Supply only stop slownait suitable for engine of capacity 110KVA/125KVA/ 90BHP AC 3 phase 415 Volts 50 HZ 0.8 PF 1500 RPM
Supply only lube oil pressure sencer suitable for engine of capacity 110KVA/125KVA/ 90BHP AC 3 phase 415 Volts 50 HZ 0.8 PF 1500 RPM
Supply only fuel pipe(as per sample) suitable for engine of capacity 110KVA/125KVA/ 90BHP AC 3 phase 415 Volts 50 HZ 0.8 PF 1500 RPM
Supply only front oil set suitable for engine of capacity 110KVA/125KVA/ 90BHP AC 3 phase 415 Volts 50 HZ 0.8 PF 1500 RPM
Supply only rear oil set suitable for engine of capacity 110KVA/125KVA/ 90BHP AC 3 phase 415 Volts 50 HZ 0.8 PF 1500 RPM
Supply only lub oil filter suitable for engine of capacity 110KVA/125KVA/ 90BHP AC 3 phase 415 Volts 50 HZ 0.8 PF 1500 RPM
Supply only fuel filter element set suitable for engine of capacity 110KVA/125KVA/ 90BHP AC 3 phase 415 Volts 50 HZ 0.8 PF 1500 RPM
Supply only nozzel suitable for engine of capacity 110KVA/125KVA/ 90BHP AC 3 phase 415 Volts 50 HZ 0.8 PF 1500 RPM
Supply only mobil oil(20W-40) suitable for engine of capacity 30KVA to 110KVA AC 3 phase 415 Volts 50 HZ 0.8 PF 1500 RPM
Supply only Coolent 1 litre pack for capacity 30KVA to 110KVA AC 3 phase 415 Volts 50 HZ 0.8 PF 1500 RPM complete all as as specified and directed.
Repairing of 110KVA/125KVA/ 90BHP Fire Fighting / Generator Engine head incl grinding, machine shop finish, polishing and pressure testing etc complete all as as specified and directed.
Repair / overhauling and servicing readiator for 110KVA/125KVA/ 90BHP Fire fighting /Generator Engine Set by (a) Dismantling and shifting from existing position and re-installing and commissioning in the same position after repair.(b) after dismantling the complete readiator part by part and cleaning thoroughly by acid with water and de-scaling all the sludge. (c) blazing all the leacking points after cleaning and must be leake proof incl machine shop for grinding & pressure test etc as required and testing complete all as as specified and directed. (Note:- Any small item required Shall be deemed included in the quoted rate)
Repair/ overhauling/ servicing/cleaning & calibration of fuel pump suitable for engine of capacity 110KVA/125KVA/ 90BHP AC 3 phase 415 Volts 50 HZ 0.8 PF 1500 RPM (Note:- Any small item required Shall be deemed included in the quoted rate)
Repair/ overhauling/ servicing / cleaning & calibration of self starter suitable for 110KVA/125KVA/ 90BHP Fire fighting Diesel Engine Set complete all as specified and directed. (Note:- Any small item required Shall be deemed included in the quoted rate).
M & L for spray painting with synthetic enamel paint of Diesel driven Gen Set / Pump motor incl fuel tank, capacity 30 KVA to 125 KVA, 415 Volts incl cleaning of oil / gerease / moisture etc and lettering SM, MES NO in white enemal paint complete all as specified and directed.
Supply only battery charger (trickel and bost, automatic type), input 220-250 Volts AC and output range upto 12 Volts DC incl 2 nos proper size of flexible cord(length not less then 1.5mtr) with good quality clamp for charging battery of make Standard radio & Winding house pvt ltd, Item code No (SB-2B10) or equivalant in sen & pandit etc complete all as specified and as directed.
Supply only battery charger (trickel and bost, automatic type), input 220-250 Volts AC and output range upto 24 Volts DC incl 2 nos proper size of flexible cord(length not less then 1.5mtr) with good quality clamp for charging battery of make Standard radio &Winding house pvt ltd, Item code No (SB-4B10) or equivalant in sen & pandit etc complete all as specified and as directed.
Supply and fixing in repair battery connecting lead, PVC insulated (Red/Black)copper cable multistanderd of size 35sqmm, 1100 volts,1mtr long with proper size of heavy duty brass connector in one side and other end to be fixed coper lug for 12volt, 180 Amps battery complete all as specified and as directed.
Supply and fixing battery 12 volt, 180 AH including taking down unserviceable battary complete all as specified and as directed. (Make - Exide Cat No MHD 1600 Express or equivalent in Amron / SF)
M&L for Heat vernising(1st quality) of the 60 KVA to 125 KVA Alternator by checking complete windings by proper magering instrument (before & after vernising), replacement of minor spares parts like sleepings, lugs etc and complete cleaning in/out side before reassembling the same and reconnection to the electric & Mechanical part, testing properly after complete work all as specified and as directed .
Repair / overhauling and servicing of Diesel Engine set for fire fighting pump / Generator Gen Set of capacity 40KVA/ 60 KVA/ 75KVA, AC 3 phase, 415 Volts, 50 HZ, 0.8 PF, 1500 RPM, Make : Kirloskar / Ashok layland (a) Dismantling and shifting of DG set from existing position and re-installing and commissioning in the same position after repair.(b) Dismantling the complete DG set part by part and cleaning thoroughly by degreasing and de-carbonising all the rotary and static parts. (c) De sludging de-carbonising & degreasing of all the parts / components such as PT Pump, Hydraulic Governer, Terbocharger, Water pump and also checking of all rotary and stationery parts of DG set for smooth functioning of engine, adjusting the pressure regulate valve settings and carrying out calibration by complete checking, aligning with fuel pump control system duly providing necessary gaskets, belts, and re-assembling after repair / replacement of unserviceable parts including greasing as required and testing complete all as specified and directed. (Note:- Spare required Shall be measured and paid as supply and fixing under respective items in this schedule)
Supply only lube oil filter element suitable for DG Set of capacity 40KVA/ 60 KVA/ 75KVA, AC 3 phase, 415 Volts, 50 HZ, 0.8 PF, 1500 RPM.
Supply only diesel filter assembly suitable for DG Set of capacity 40KVA/ 60 KVA/ 75KVA, AC 3 phase, 415 Volts, 50 HZ, 0.8 PF, 1500 RPM.
Supply only corrosion filter assembly suitable for DG Set of capacity 40KVA/ 60 KVA/ 75KVA, AC 3 phase, 415 Volts, 50 HZ, 0.8 PF, 1500 RPM.
Supply only lube oil cooler pipe suitable for DG Set of capacity 40KVA/ 60 KVA/ 75KVA, AC 3 phase, 415 Volts, 50 HZ, 0.8 PF, 1500 RPM.
Supply only super bypass mobil filter suitable for DG Set of capacity 40KVA/ 60 KVA/ 75KVA, AC 3 phase, 415 Volts, 50 HZ, 0.8 PF, 1500 RPM.
Supply only readiator cap suitable for DG Set of capacity 40KVA/ 60 KVA/ 75KVA, AC 3 phase, 415 Volts, 50 HZ, 0.8 PF, 1500 RPM.
Supply only air cleaner filter element suitable for DG Set of capacity 40KVA/ 60 KVA/ 75KVA, AC 3 phase, 415 Volts, 50 HZ, 0.8 PF, 1500 RPM.
Supply only tube oil filter big element suitable for DG Set of capacity 40KVA/ 60 KVA/ 75KVA, AC 3 phase, 415 Volts, 50 HZ, 0.8 PF, 1500 RPM.
M&L for PCC 1:3:6 type C2 (using 40mm graded stone aggregate) as in foundation and mass concrete etc all as specified and as directed.
S & F in repairs Water temp meter suitable for DG Set of capacity DG Set of capacity 40 to 125 KVA, AC 3 phase, 415 Volts, 50 HZ, 0.8 PF, 1500 RPM all as specified and as directed.
S & F in repairs Volt meter(0 - 500 V) suitable for DG Set of capacity 40 to 125 KVA, AC 3 phase, 415 Volts, 50 HZ, 0.8 PF, 1500 RPM all as specified and as directed.
S & F in repairs RPM meter suitable for DG Set of capacity 40 to 125 KVA, AC 3 phase, 415 Volts, 50 HZ, 0.8 PF, 1500 RPM all as specified and as directed.
Supply & pouring distrilled water in 5 ltr jar complete all as specified and as directed.
M&L for earthing with galvanised earth plate electrode 600 x 600 x 6 mm thick burried directly in ground vertically to a depth of not less than 2.25 mtr below ground level connected to galvanised iron strip 32×6mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or mild steel and 40 mm dia GI pipe "light grade" for protection of earth lead strip(up to 7.5 RM) and connected to control board or pannel or as directed by Engr -in-Charge including earthing pit in PCC (1:3:6) type C1 pre-cast cover RCC cover slab of size 300 x 300 x 50 mm with one handle made out of 8 mm dia round bar 20 mm dia GI pipe light grade for watering funnels , wire mesh and provision of charcoal or coke in alternative layers of 15 cm including necessary earth work complete all as shown in electrical plate No 5 and tesing complete all as specified and directed by Engr-In-Charge.
Excavating in trenches n. exc. 1.5 m. wide and n. exc. 1.5 m. in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pire holes, etc. n. exc. 10 sqm on plan and not exc. 1.5 m. in depth and getting out in soft/loose soil complete all as specified and as directed.
Returning filling including spreading levelling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil complete all as specified and as directed.
Removing excavated soil not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point in soil complete all as specified and as directed.
M&L for sand cushioning for protection of cables (below, above and around the cable laid in trenches) complete using clean, dry sand complete all as specified and as directed.
Supply and laying well burnt bricks sub class 'B' laid breadth wise along length of cable in trenches after sand cushioning laid for underground cable protection complete all as specified and as directed
Laying well burnt bricks sub class 'B' laid breadth wise along length of cable in trenches after sand cushioning laid for underground cable protection complete all as specified and as directed
Taking up or down 50 mm bore steel tubing and connections trenches / pole etc including cleaning for refixing or removal complete all as specified and directed.
Supply and laying tubes 50 mm dia steel water tube light grade galvanised with all fittings laid in trenches complete all as specified and as directed.
Taking out old unserviceable LT cables of cross sectional area upto 120 sqmm including bricks or pre-cast concrete cable cover etc of any description from trenches / walls / poles by disconnecting the cable from pole /feeder /panel board etc. and keep serviceable bricks or pre-cast concrete cover, cable, pipe etc. in safe custody for re-use and unserviceable materials removing from site all as specified and as directed. Note : (i) Excavation and earth work shall be measured and paid separately.
Supply and laying in trenches or fixing or passing through pipes or fixed to wall/pole 1100 volts grade PVC/ XLPE insulated armoured heavy duty electric cables (conforming to IS :1554(Part- I) / IS 7098 (Part- I)with aluminium conductor of cross sectional area 6 Sqmm 2 core complete all as specified and as directed.
Supply and laying in trenches or fixing or passing through pipes or fixed to wall/pole 1100 volts grade PVC/ XLPE insulated armoured heavy duty electric cables (conforming to IS :1554(Part- I) / IS 7098 (Part- I)with aluminium conductor of cross sectional area 95 Sqmm 3.5 core complete all as specified and as directed.
Laying/Fixing only Serviceable LT UG armoured PVC/XLPE cable of the size of Size 10 - 95 Sqmm, 3.5 Core to be fixed on wall with M.S. Saddles with Base made out of 50 x 6 mm MS Flat, Bolts, Nuts etc spaced evenly @ 0.5 RM c/c complete all as specified and as directed. (Note : MS saddles , bolts etc should be deemded to included in quoted rate)
Supply and laying in trenches or fixing or passing through pipes or fixed to wall/pole 1100 volts grade PVC/ XLPE insulated armoured heavy duty electric cables (conforming to IS :1554(Part- I) / IS 7098 (Part- I)with aluminium conductor of cross sectional area 35 Sqmm 3.5 core complete all as specified and as directed.
Supply and laying in trenches or fixing or passing through pipes or fixed to wall/pole 1100 volts grade PVC/ XLPE insulated armoured heavy duty electric cables (conforming to IS :1554(Part- I) / IS 7098 (Part- I)with aluminium conductor of cross sectional area 50 Sqmm 3.5 core complete all as specified and as directed.
Supply and laying in trenches or fixing or passing through pipes or fixed to wall/pole 1100 volts grade PVC/ XLPE insulated armoured heavy duty electric cables (conforming to IS :1554(Part- I) / IS 7098 (Part- I)with aluminium conductor of cross sectional area 25 Sqmm 3.5 core complete all as specified and as directed.
Repair/ maintenance of HT Oil Isolating switch(VLE) unit of 200 Amps capacity, 3 phase manually operated fixed/draw out ID type oil isolating switch 11KV/200A, MEI make at Teesta building by removing the breaker from panel discmantling carefully its parts/accessories. Cleaning the dust/impurities and accumulations etc blowering/brushing cleaning properly with CRC-26 spray to remove rust including supply of gasket, oil seal, nut & bolts, washers, reassembles, the parts /accessories and fix in same position and connection, testing for satisfactory operation all as directed. (Note: (i) Maintenance /repairs shall be carried out by trained technicians/mechanic . (ii) All repairs shall be carried out at site only. Necessary testing,/measuring instrument shall be brought at site by the contractor at the time of work and all cost on this account should be included in the quoted rate. (iii) Major parts/accessoreis for HT Oil Isolating switch(VLE) unit shall be meausured and paid separately under respective items in this schedule.
M & L Cable jointing kit for 1100 V (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 16 sqmm to 120 sqmm incl cutting of old jointing material including taking down old one complete all as specified and as directed. (Make of Kit - M-seal / Denson / Raychem)
Repair/maintannces of transformer of any make 6 KV/440V step down type & capacity for 300 KVA & below by disconnecting electric supply draining out transformer oil and stocking for re-use opening up top cover, checking / cleaning the core by hanging up the Tr. core/winding, HT/LT winding , tank conservator, connections etc removing sludge/scaling etc deposited. Opening the HT/LT terminal boxes, checking / changing /cleaning the bushes oil seals, gaskets nuts & bolts etc as required number checking & replacement of top cover gasket, breather & vent pipe gasket, reassembling testing & commissioning complete all as specified and as directed. (Note : (i) Maintenance /repairs of transforerms shall be carried out by trained technicians/mechanic under super vison of qualified electrical technician. (ii) All repairs shall be carried out at site only. Necessary testing,/measuring instrument shall be brought at site by the contractor at the time of work and all cost on this account should be included in the quoted rate (iii) Major parts/accessoreis for transformer shall be meausured and paid separately under respective items in this schedule.
Supply only oil seal for LT bushing of transformer of 6 KV/440V step down type & capacity for 200KVA & below complete all as specified and directed
Supply only LT(415V) sides brass studs incl buses, porceline, brass nuts, bolts, washers etc complete set/kit for 200 KVA transformer(as per sample) complete all as specified and as directed.
Supply only silica gel and taking out old one complete all as specified and directed.
Dehydration & filteration of transformer oil for various type transformer / VCB / VLE as retrieved in above items by heating of oil, testing dielectric strength of oil not less than 40KV in 2.5mm sparking gap complete all as specified and as directed.
Supply & filling only Transformer Oil for topping up the level with grade as per IS : 335 and charging the transformer to the supply voltage complete all as specified and directed. (Make- Power Oil / IOC/Gulf). (Note : Dielectric strength of the oil shall be ensured not less than 40 KV before filling)
S & F thermometer with brass stiff necessary sensing device of range 0-120degC for indoor type transformer complete all as specified and as directed including taking down old one complete all as specified and directed.
Removing existing old paint by scraping from transformer of capacity 200KVA, fins and conservator tank, and applying two coats of synthetic enamel paint (1st quality) by spraying including writing SM/MES No, capacity in white paint complete all as specified and directed.
Repair/maintannce/overhauling of 6 KV HT VCB of capacity for 630 Amps by disconnecting electric supply connection and opening cover by checking / inspection / cleaning part by part after come out the enter system(spring action lever), connections etc removing sludge/scaling etc deposited. Opening the HT terminal boxes, checking / cleaning the all fiexd/moving parts, changing the cable glands, thembles/lugs of HT cable, nuts & bolts etc as required number, reassembling testing & commissioning after repair complete all as specified and as directed. (Note : (i) Maintenance /repairs of HT VCB shall be carried out by trained technicians/mechanics. (ii) All repairs shall be carried out at site only. Necessary testing,/measuring instrument shall be brought at site by the contractor at the time of work and all cost on this account should be included in the quoted rate (iii) Major parts/accessories for HT VCB shall be meausured and paid separately under respective items in this schedule.
Supply only spring action leaver(as per sample) for 6 KV HT VCB of capacity for 630 Amps complete all as specified and directed.
Supply only RYB indicator lamp LED pilot lamp with BA 9S lamp filament bulb for input voltage 240V and output volt 6V AC complete all as specified and directed. (Cat - SIL[][][][][] of Make- L&T or equivalent Make of C&S/ABB)
Supply only LED 3Ph Voltmeter Class 1, Input voltage measurement range 0-500 VAC (P-P), Flush mounting 96 x 96 mm, complete all as specified and directed. (Make- L&T Cat No WL131010OOOO orequivalent in C&S/HPL/ABB)
Supply only LED 3Ph Ammeter, Class 1, 0-150 A, Flush mounting 96 x 96 mm, complete all as specified and directed. (Make- L&T Cat No WL131020OOOO orequivalent in C&S/HPL/ABB)
S&F MCCB 400 Amps, 4 Pole, 36 KA breaking capacity, 415V thermal magnetic release. Type - DPX 630 including taking out old one complete all as specified and directed. (Cat-4220-07 of Make- Legrand or L&T/Schneider )
S&F MCCB 250 Amps, 4 Pole, 36 KA breaking capacity, 415V thermal magnetic release. Type - DPX 250 including taking out old one complete all as specified and directed. ( Cat -4202 49 of Make- Legrand or L&T/Schneider)
S&F MCCB 100 Amps, 3 Pole,16 KA breaking capacity, 415V thermal magnetic release. Type - DPX 160 including taking out old one complete all as specified and directed.(Cat -4200 05 of Make- Legrand or L&T/Schneider)
S&F MCCB 63 Amps, 3 Pole,16 KA breaking capacity, 415V thermal magnetic release. Type - DPX 160 including taking out old one complete all as specified and directed.(Cat -4200 03 of Make- Legrand or L&T/Schneider )
S&F Onload Changeover switch cubical type I-O-II for 400 Amps, 4 POLE, Fr 4, type C04-400, Open execution, including taking out old one complete all as specified and directed. (Cat - CO44000OOOO of Make -L&T or equiv in C&S/GE)
Attending team of electrician, helper with tools and necessary accessories for emergency breakdown to check defective APFC panel at own arrangement as and when directed during currency of contract. (Note - The item shall be operated maximum 2 times in entire period of contract in the same installations ( measured separtely each time))
Disconnecting, repair and maintenance of APFC panel and replacement of internal wiring by using different size of new copper cable single core 1100V with necessary crimping, washer nuts & bolts of different size with necessary colour coding, checking and taking out defective unserviceable parts and replaced the same to make serviceable connection, testing etc. as directed. (Note: (i) Maintenance / repairs shall be carried out by trained technicians / mechanic . (ii) All repairs shall be carried out at site only. (iii) Spare / parts shall be measured and paid seperately as ''supply only''
Supply only 5 KVAR capacitor, box series type-LTXL-Ultra heavy duty, 440V, complete all as specified and directed. (Make- L&T /BCH/ABB)
Supply only 15 KVAR capacitor, box series type-LTXL-Ultra heavy duty, 440V, complete all as specified and directed. (Make- L&T /BCH/ABB)
Supply only 20 KVAR capacitor, box series type-LTXL-Ultra heavy duty, 440V, complete all as specified and directed. (Make- L&T /BCH/ABB)
Supply only 20 KVAR rating reactor,heavy duty, lower operating losses, 440V, 50Hz, complete all as specified and directed. (Cat No LTFR0720B2 of Make- L&T or equivalent in BCH/ABB)
Supply only 15 KVAR rating reactor,heavy duty, lower operating losses, 440V, 50Hz, complete all as specified and directed. (Cat No LTFR0715B2 of Make- L&T or equivalent in BCH/ABB)
Supply only APFC Relay meter (8 Staps) complete all as specified and directed, (Make L&T of model etaCON L8, Cat No : ERPML08D500 or equivalent Make of BCH/ABB).
Supply only capacitor duty contractors of 20kvar rating, type MO C20, size Fr 1 complete all as specified and directed, (Make L&T of Cat No : CS90021 or equivalent Make of BCH/ABB).
Supply only capacitor duty contractors of 15kvar rating, type MO C15, size Fr 1 complete all as specified and directed, (Make L&T of Cat No : CS90019 or equivalent Make of BCH/ABB).
Supply only MCB TP 63A, 415 Volt, 10 KA, (Make L&T Cat No : BB30630C of or equivalent Make of BCH/ABB).
Supply only MCB SP 6A, 240 Volt, 10 KA, (Make L&T Cat No : BB10060C of or equivalent Make of BCH/ABB.)
Supply only cooling fan of size 4"(100mm), 2400 rpm, 230V, PVC blade complete all as specified and directed.
Taking up Earth continuity conductor any size from any location incl cutting wall/floor, excavating soil or from surface complete all as directed
M&L for GI strip 32 mm x 6mm as earth continuity conductor fixed to wall/burried in ground/drawn through conduit or pipe or fixed to pole for loop earthing complete all as specified and directed.
S&F breather unit fot transformer indoor type (as per sample)including taking down old one complete all as specified and directed.
S&F Aluminium strip 25 x 3.15mm with porceline insulator and fixing screws etc. as roof conductors and down conductors above ground floor for the lightening arrester complete all as specified and directed including taking out old one.
M&L Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm burried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr below ground level connected to galvanised iron or steel earth lead MS flat 25 x 4 mm by means of nuts, bolts, check nuts and washers of galvanised iron or steel, earth wire protected by galvanised iron pipe 50 mm dia (light grade) and connected to main switch board or main control panel as directed and as specified including concrete pit in PCC (1:3:6) type C1 pre-cast RCC cover slab 5 cm thick of size as shown reinforced with 8 mm dia TMT / deformed bars 100 mm c/c both ways including one handle made of 12 mm dia MS bars of length 500 mm, funnel, wiremesh 20 mm bore galvanised iron pipe medium grade for watering, charcoal and salt in alternate layers including necessary earth work complete all as shown in elect plate No. 3 of SSR Part I, all as directed.
M&L for LED avaiation light luminaires integral LED avaiation light comprising of aluminium housing with polycarbonate enclosure, 302 nos LED are provided including necessary fixing arrangement, electric connection with insulated three core flexible copper conductor of suitable size complete all as specified and directed incl taking down old one. (Make -Bajaj Cat No BGAV302 LED or equivalent in Philips/CG).
Supply & fix Air termination single pointed aluminum rod 12 mm dia and 300 mm long including taking down old unserviceable one complete all as specified and as directed.
Supply & fix Test point terminal block made of gunmetal or phosphorus bronze of size 75 x 75 x 25 mm, drilled and screwed including 3 nos 8 mm dia 25 mm long hex head screw complete all as specified and as directed including taking down old unserviceable one.
M&L for Decorative post top lantern for 360 degree , 40Watt, indirect light suitable for pipe 50mm dia including connection from connector to switch including taking down old one complete all as specified and as directed. Make - CG cat No LPTO-40-CDL or equivalent in Bajaj/Philips
S&F bollard LED luminaries,10 watt with IP 65 protection,including suitable size of wire from joint box to connector including taking down old unserviceable fitting complete all specified and directed.(Make : CG Cat no LBLSN-10-CDL or equivalent in PHILIPS/ Bajaj/ HAVELLS)
M&L for road lighting luminaire with pinnacle plus led street light made of pressure die cast aluminium housing with integrated polycarbonate lens 70 watt with IP 66 protection ideal for road width upto 15 mtr,including connection complete including taking down old unserviceable fitting all as specified and directed. (Make : CG Cat no LST-70-CDL or equivalent in PHILIPS/Bajaj/HAVELLS)
MS HORIZEN
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .