Financial Eligibility Criteria: (Ref: RB letter No. 2022/CE- I/CT/GCC2022/POLICY : Advance Correction Slip No.-1 dt 14.07.2022) The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-I, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
The intending tenderers should possess a valid electrical contractor license at the time of opening of tender, issued by any state government & same should be submitted along with tender documents by all bidders including working contractors of this unit otherwise offer shall be summarily rejected....... IT SHOULD BE NOTED BY THE TENDERER THAT ELECTRICAL LICENSE UNDER RENEWAL AT THE TIME OF TENDER OPENING WILL NOT BE CONSIDERED AND OFFER WILL BE SUMMARILY REJECTED. IT IS THE RESPONSIBILITY OF TENDERER TO UPLOAD VALID ELECTRICAL CONTRACTOR LICENSE ON THE DATE OF TENDER OPENING.
All requisite documents mentioned in clause 3.7 of the tender document attached pertaining to constitution of firm/concern. (As applicable).
36 conditions · 4 needing a document upload
The rate to be quoted by tenderer shall be inclusive of all state/central taxes including GST. THE TENDERER SHOULD UPLOAD VALID GST REGISTRATION CERTIFICATE ALONG WITH THE OFFER.
The tender shall comply with General Condition of contract (GCC),2022 of Indian Railways (file attached). and its latest amendment, if any. The tenderer shall submit the offer after duly satisfying himself/herself with the GCC,2022 in general.
Tenderers are required to upload the Bank details as per Annexure-XII (Real Time Gross Saving (RTGS)/National Electronic Fund Transfer (NEFT) Model Mandate Form)of tender document.
Tenderers are required to upload requisite details as per Annexure-VIIB (DETAILS OF CONTRACTUAL PAYMENT RECEIVED IN LAST THREE FINANCIAL YEARS AND CURRENT FINANCIAL YEAR) without which the offer is liable to be rejected.
Tenderers are compulsorily required to upload Affidavit as per Annexure-XXIV along with tender document, without which the offer will be considered incomplete and will be rejected summarily.
All requisite documents/credentials mentioned in clause 3.5 of the tender document attached pertaining to his/their technical and financial eligibility. (As applicable).
All requisite documents mentioned in clause 3.7 of the tender document attached pertaining to constitution of firm/concern. (As applicable).
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
No post tender correspondence for submission of additional documents shall be entertained after opening of the Technical & Commercial offers. Even suo-moto post tender letters of the tenderer/s shall be treated as Null & Void.
This tender complies with Public Procurement Policy (Make in India) Order 2017, dated 15/06/2017, issued by Department of Industrial Promotion and Policy, Ministry of Commerce, circulated vide Railway Board letter no. 2015/RS(G)/779/5 dated 03/08/2017 and 27/12/2017.
IF ANY DISCREPANCY IS FOUND IN THE TENDER DOCUMENT, NAMELY SOR ITEM DESCRIPTION, SPECIAL TENDER CONDITION ETC., CLARIFICATION CAN BE SOUGHT FROM THE OFFICE OF SRDEE/G/DLI, DRM OFFICE, STATE ENTRY ROAD, NEW DELHI.
This tender complies with Railway Board instructions for Startups (recognized by Department of Industrial Policy and Promotion, Ministry of Commerce and Industry) for exemption from payment of Bid Security as detailed in GCC 2022 as amended from time to time. Such Startup firms may note that no other exemption is applicable to them in this particular tender.
On account payment, contractor shall submitted indemnity bond with validity up to the completion/extended period in the prescribed format (please refer Annexure-XXVIII) at the contractor's cost, vesting the ownership of such material with the railways.
This tender shall also complies with "Indian Railways Standard General Conditions of Contract, April 2022 (Advance Correction Slip No. 11)" vide Railway Board letter No. 2022/CE-I/CT/GCC- 2022/POLICY/Pt.I (E-3320424), dated: 13.03.2026 (attached)
The rate to be quoted by tenderer shall be inclusive of all state/central taxes including GST. tenderer shall submit GST certificate along with the offer.
All disputes or differences of any kind whatsoever arising out of or in connection with this contract, whether during its execution or after completion, termination, or breach thereof, shall be subject to the exclusive jurisdiction of the competent courts at New Delhi only.
The issues not covered under the tender document shall be governed by General conditions of Contract (GCC) 2022 or its latest amendments if any during entire period of contract. If any contradiction in Tender Document and GCC is observed then GCC shall prevail.
Defective parts shall only be replaced with OEM's spares. Proper invoices/delivery challan /warranty certificate etc. shall be provided by the firm to prove genuineness of spare parts.
Electrical work in connection with, (i) Provision of Pit-line for the maintenance of NMG rakes at TKD Yard. (ii) Setting up of Bio Toilet Testing Lab in coaching depot at JHI.
82-SRDEE-G-DLI-2026-27
82-SRDEE-G-DLI-2026-27
Open
Works - General
12 Months
Delhi, Delhi
₹0
₹2.6 L
8 Jun 2026
15 May 2026
25 May 2026
63 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | Above/ Below/P ar | ||
| Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLSH/HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required conforming to CPWD General Specifications for Electrical Works Part-I Internal - 2023 and CPWD DSR (E&M) 2025 & IS 732:2019 (reviewed 2024) & as per explanatory note. Group C | — | 110.00 | — | — | |
| Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLSH/HFFR PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required of reputed make as per IS, IE rules and site requirement and conforming to CPWD General Specifications for Electrical Works Part-I Internal - 2023, CPWD DSR (E&M) 2025 & as per explanatory note. Size : 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire | — | 600.00 | — | — | |
| Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLSH/HFFR PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required of reputed make as per IS, IE rules and site requirement and conforming to CPWD General Specifications for Electrical Works Part-I Internal - 2023, CPWD DSR (E&M) 2025 & as per explanatory note. Size : 2 x 4 sq. mm + 1 x 4 sq. mm earth wire | — | 400.00 | — | — | |
| Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLSH/HFFR PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required of reputed make as per IS, IE rules and site requirement and conforming to CPWD General Specifications for Electrical Works Part-I Internal - 2023, CPWD DSR (E&M) 2025 & as per explanatory note. Size : 2 x 6 sq. mm + 1 x 6 sq. mm earth wire | — | 200.00 | — | — | |
| Supply of ceiling rose, 3 pin conforming to IS : 371-1999 (or latest) & installation on the junction box of laid conduit including connections, testing & commissioning as per site requirement and conforming to CPWD General Specifications for Electrical Works Part-I Internal - 2023 and CPWD DSR (E&M) 2022 or latest & as per explanatory note. | — | 80.00 | — | — | |
| Supply and recessing/fixing of PVC conduit pipe of 25 mm dia conforming to IS. 9537 Part-III 1983 (or Latest version) with accessories junction box, bends etc. including making chase, plastering/clamping etc. as per site requirement & as per explanatory note. | — | 200.00 | — | — | |
| Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required and conforming to IS 3854:2023/ IEC 60669-1, IS 14772:2020 & CPWD General Specifications for Electrical Works Part-I Internal - 2023 and CPWD DSR (E&M) 2022 or latest & as per explanatory note. | — | 45.00 | — | — | |
| Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required and conforming to IS 3854:2023, IS 14772:2020 or latest & CPWD General Specifications for Electrical Works Part-I Internal - 2023 and CPWD DSR (E&M) 2022 or latest & as per explanatory note. | — | 35.00 | — | — | |
| Supply, Fixing, testing & commissioning of following sizes FRLSH PVC insulated multi stranded copper (annealed) conductor single core cable conforming to IS 694 (or Latest Version) , and drawing in Laid (recessed /surface) PVC conduit pipe for wiring of point wiring / circuit wiring / sub main / main as required including connections, testing and commissioning & as per explanatory note. Size 1x2.5 sq.mm | — | 500.00 | — | — | |
| Supply, Fixing, testing & commissioning of following sizes FRLSH PVC insulated multi stranded copper (annealed) conductor single core cable conforming to IS 694 (or Latest Version) , and drawing in Laid (recessed /surface) PVC conduit pipe for wiring of point wiring / circuit wiring / sub main / main as required including connections, testing and commissioning & as per explanatory note. Size 1x4.0 sq.mm | — | 300.00 | — | — | |
| Supply, Fixing, testing & commissioning of following sizes FRLSH PVC insulated multi stranded copper (annealed) conductor single core cable conforming to IS 694 (or Latest Version) , and drawing in Laid (recessed /surface) PVC conduit pipe for wiring of point wiring / circuit wiring / sub main / main as required including connections, testing and commissioning & as per explanatory note. Size 1x6.0sq.mm | — | 100.00 | — | — | |
| Supply, fixing, testing and commissioning of following modules, GI box alongwith modular base and cover plate for modular switches/ sockets in recess etc as required as per IS, IE rules and site requirement complete and conforming to CPWD General Specifications for Electrical Works Part-I Internal - 2023 conforming to IS 3854 or latest & as per explanatory note. Size= 6 Module | — | 15.00 | — | — | |
| Supply, fixing, testing and commissioning of following modules, GI box alongwith modular base and cover plate for modular switches/ sockets in recess etc. as required as per IS, IE rules and site requirement complete and conforming to CPWD General Specifications for Electrical Works Part-I Internal - 2023 conforming to IS 3854 or latest & as per explanatory note. Size= 8 Module | — | 10.00 | — | — | |
| Supplying and fixing following modular switch /socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required as per IS 3854 or latest, IE rules and site requirement complete and conforming to CPWD General Specifications for Electrical Works Part-I Internal - 2023 & as per explanatory note. 6 Amp switch | — | 30.00 | — | — | |
| Supplying and fixing following modular switch /socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required as per IS 3854 or latest, IE rules and site requirement complete and conforming to CPWD General Specifications for Electrical Works Part-I Internal - 2023 & as per explanatory note. 16 Amp switch | — | 30.00 | — | — | |
| Supplying and fixing following modular switch /socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required as per IS 3854 or latest, IE rules and site requirement complete and conforming to CPWD General Specifications for Electrical Works Part-I Internal - 2023 & as per explanatory note. 3 pin 5/6 A socket outlet | — | 40.00 | — | — | |
| Supplying and fixing following modular switch /socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required as per IS 3854 or latest, IE rules and site requirement complete and conforming to CPWD General Specifications for Electrical Works Part-I Internal - 2023 & as per explanatory note. 6 pin 15/16 A socket outlet | — | 40.00 | — | — | |
| Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required as per IS 11037 (latest version) and conforming to CPWD General Specifications for Electrical Works Part-I Internal - 2023 and CPWD DSR (E&M) 2022 or latest & as per explanatory note. | — | 25.00 | — | — | |
| Supply, fixing, Testing and Commissioning of 400 mm sweep BLDC wall mounted fan as per relevant IS complete & as per explanatory note. | — | 10.00 | — | — | |
| Supply, fixing, testing and commissioning of energy efficient 230V, 50Hz a.c. ceiling fan size of 1400 mm sweep, 5 star rating, having wattage of 35/40W, range of voltage operation at various speed - 120 to 260V AC, speed of 270 to 290 RPM with 5 speed control electronic regulator, copper winding complete as per IS : 374 - 1979 or latest, IE rule & site requirement. Make-Atomberg, Usha, Orient, Havells, Crompton, Bajaj or equivalent. It shall also include the scope of supply and installation of safety cord of SS as per IS:302 Part 2 Sec-80. Dia & length of such cord shall be as per recommendation of OEM of fan and same shall be approved by railways & as per explanatory note. | — | 25.00 | — | — | |
| Supply, fixing, testing & commissioning of 250mm sweep fresh air fan complete conforming to IS 2312 & IS 302 or latest and other relevant IS/IEC standards & as per explanatory note. Make: Bajaj, Usha, Havells, Orient or equivalent. | — | 10.00 | — | — | |
| Supply, installation, testing and commissioning of single phase propeller type exhaust fans sweep size 300 mm etc. including grounting of MS nuts, bolts and connection complete as per relevant IS & IE rules & site requirement and as per explanatory note. Make Bajaj, Usha, Havells, Orient or equivalent | — | 5.00 | — | — | |
| Supply, fixing, testing and commissioning of 380mm sweep, 1400 rpm (approx) propeller type exhaust fan complete in all respect as per specification and as per site requirement, including grouting of nut, bolts, washer and with the suitable fasteners conforming to IS 2312 or latest & IS 302 or latest and other relevant IS/IEC standards and as per explanatory note. Make Bajaj, Usha, Havells, Orient or equivalent | — | 8.00 | — | — | |
| Supply, fixing, testing and commissioning of LED light luminaire, having system wattage 1x18-20 watt. LED tube and inbuilt LED driver, CRCA body powder coated, complete with all mounting arrangement, accessories. CRI >= 80, SDCM (standard deviation color matching) <3, The LED based 4 ft. tube light (lamp) shall be conforming to confirming to CEE/NR's spec. No. CEE/NR/121-Elect/PS/2018 (Rev- '3') or latest at Tech Spec-I attached & PCEE/NR's spec. No. PCEE/NR/121-Elect/PS/2019 (Rev- '4') at Tech Spec-II attached or latest and as per explanatory note. | — | 80.00 | — | — | |
| Supply, fixing, testing and commissioning of LED light luminaire, having system wattage 2x18-20 watt. LED tube and inbuilt LED driver, CRCA body powder coated, complete with all mounting arrangement, accessories. CRI >= 80, SDCM (standard deviation color matching) <3, The LED based 4 ft. tube light (lamp) shall be conforming to confirming to CEE/NR's spec. No. CEE/NR/121-Elect/PS/2018 (Rev- '3') or latest at Tech Spec-I attached & PCEE/NR's spec. No. PCEE/NR/121-Elect/PS/2019 (Rev- '4') at Tech Spec-II attached or latest and as per explanatory note. | — | 20.00 | — | — | |
| Supply, fixing, testing and commissioning of Recessed/ on surface LED light luminaries 595x595 mm size, Tile type, having system wattage less than or equal to 48 Watt, CRCA body powder coated, high efficiency milky white PMMA diffuser with no bright spot visible, complete with all mounting arrangement, accessories of make Phillips, Bajaj, Havells or similar confirming to CEE/NR's spec. No. CEE/NR/121-Elect/PS/2018 (Rev- '3') or latest at Tech Spec-I attached & PCEE/NR's spec. No. PCEE/NR/121-Elect/PS/2019 (Rev'4') at Tech Spec-II attached or latest and as per site requirement & as per explanatory note. | — | 15.00 | — | — | |
| Supply of LED based focus light having wattage less than or equal to 10W (approx.) complete with driver as per relevant IS, IE rules, site requirement and prior approval of sample conforming to CEE/NR's spec. No. CEE/NR/121-Elect/PS/2018 (Rev- '3') or latest at Tech Spec-I attached & PCEE/NR's spec. No. PCEE/NR/121-Elect/PS/2019 (Rev'4') at Tech Spec-II attached or latest & as per explanatory note. | — | 5.00 | — | — | |
| Supply of LED down lighter, housing aluminum die cast, white powder coated and PMMA diffuser having system wattage less than or equal to 15-18 Watt complete with all mounting arrangement, accessories complete confirming to CEE/NR's spec. No. CEE/NR/121-Elect/PS/2018 (Rev- '3') or latest at Tech Spec-I attached & PCEE/NR's spec. No. PCEE/NR/121-Elect/PS/2019 (Rev- '4') at Tech Spec-II attached or latest & as per explanatory note. | — | 5.00 | — | — | |
| Supply, fixing, testing and commissioning of 4-feet long surface mounting 36-Watt, 5700K,CRI>80, LED Luminaire as per relevant IS 10322 (Part 1):2014 Reviewed In : 2025, IE rules and site requirement. Fitting shall be environmentally friendly, long life, corrosion resistant, impact proof IP 66 with PC housing & opal finish cover suitable for wet location similar to Make - Havells Model No. MAGNUM NEO or equivalent. Fitting shall be suitable for operation on single phase 240Volt, 50 Hz AC supply and conforming to CEE/NR's spec. No. CEE/NR/121 Elect/PS/2018 (Rev- '3') or latest at Tech Spec-I attached & PCEE/NR's spec. No. PCEE/NR/121 Elect/PS/2019 (Rev- '4') at Tech Spec-II attached or latest & as per explanatory note. | — | 12.00 | — | — | |
| Supply, fixing, testing and commissioning of 45-50 watt LED based street light luminary with CRI >= 70, SDCM (standard deviation color matching) <5 ,single housing, side entry, high pressure aluminum die cast/extruded aluminum, IP 66 or better having system complete conforming to CEE/NR's spec. No. CEE/NR/121-Elect/PS/2018 (Rev- '3') or latest at Tech Spec-I attached & PCEE/NR's spec. No. PCEE/NR/121-Elect/PS/2019 (Rev- '4') at Tech Spec-II attached or latest & as per explanatory note. | — | 130.00 | — | — | |
| Supply, fixing, testing and commissioning of 150-155 W LED LED based flood light luminary with CRI >= 70, SDCM (standard deviation color matching) <5, single housing, side entry, high pressure aluminum die cast/extruded aluminum, IP 66 or better having system complete conforming to CEE/NR's spec. No. CEE/NR/121-Elect/PS/2018 (Rev- '3') or latest at Tech Spec-I attached & PCEE/NR's spec. No. PCEE/NR/121-Elect/PS/2019 (Rev- '4') at Tech Spec-II attached or latest & as per explanatory note. | — | 54.00 | — | — | |
| Supply & erection of hot dip galvanized octagonal pole 5 Mtrs. long Double Arms, confirming to IS 2629/BSEN ISO 1461 latest version with top 70 mm and bottom 130 mm around face made of 3 mm thick, steel base plate size 200 x 200 x 12 mm complete with appropriate sleeve at the top of the pole for mounting arm bracket 300 mm long (or as per site requirement) suitable for LED street light fittings including casting, muffing with cement concrete foundation (1:2:4) painting, earthing and foundation GI nut, bolts with washer and smart pack junction box with 1A single pole MCB and terminals. Pole junction box shall be sealed with water proof tape and display of danger sticker. Note- Wiring in between pole junction box to fitting shall be done through 3 cores 1.5 sq. mm double insulated weather proof cables confirming to IS 456 or latest & other relevant IS/IEC standards & as per explanatory note. | — | 60.00 | — | — | |
| Fabrication, supply and erection of Fencing around the high mast in square shape size 2M x 2M and height 1.5M from ground level fabricated from MS angle size 40x40x6mm, MS Flat size 40x6mm and wire mesh made of 8SWG wire and 1M wide hinged type lockable door as per drawing approved by Railway including grouting, CC platform around the high mast above 0.30M above ground level and painting, danger plate etc. complete as per site requirement & as per explanatory note. | — | 6.00 | — | — | |
| Supply, errection, testing and commissioning of 16 meter high mast system suitable for 9 Nos. LED flood light luminaries with the help of suitable equipment including accessories control panel for high mast system as per IS 875, IS 800, IS 10322, IS 2062 or other relevant IS/IE rules for provision of RCBO in place of MCB from I/C side. Each high mast shall also have one twin dome aviation obstruction light with 2 nos. LED lamp & as per explanatory note. Make BAJAJ, Osram, PHILIPS, GE or equivalent. | — | 6.00 | — | — | |
| Supply, fixing, testing and commissioning of astronomical timer based control panel for High Mast tower lighting suitable for 25A 4 P contactor as per model No. Alpha Rex3 D21, 1 channel Cat Part 412654 of Legrand or equivalent. Panel should be double door weather proof type complete of IP 65 rating & as per explanatory note. | — | 6.00 | — | — | |
| Supply, fixing, testing and commissioning of 48V, 50 Hz LED based bulk head/catwalk/pathway light luminary with IP-67 protection, impact resistance IK10 having system wattage less than or equal to 22 watt complete with anti theft mounting arrangement, mounting arrangement made out of 2 mm thick CRCA sheet with anticorrosive treatment and suitable mounting as per site requirement of make Phillips, Bajaj, Havells or similar conforming to CEE/NR's spec. No. CEE/NR/121 Elect/PS/2018 (Rev- '3') or latest at Tech Spec-I attached & PCEE/NR's spec. No. PCEE/NR/121 Elect/PS/2019 (Rev- '4') at Tech Spec-II attached or latest & as per explanatory note. | — | 200.00 | — | — | |
| Supply, fixing, testing and commissioning of 48V, 50 Hz LED based pit light luminary with IP-67 protection, impact resistance IK10 having system wattage 22 watt complete with anti theft mounting arrangement made out of 2 mm thick CRCA sheet with anti corrosive treatment and suitable mounting as per site requirement of make Phillips, Bajaj, Havells or similar conforming to CEE/NR's spec. No. CEE/NR/121 Elect/PS/2018 (Rev- '3') or latest at Tech Spec-I attached & PCEE/NR's spec. No. PCEE/NR/121 Elect/PS/2019 (Rev- '4') at Tech Spec-II attached or latest & as per explanatory note. | — | 200.00 | — | — | |
| Supply, fixing, testing & commissioning of Step down single phase transformer 230V/110V or 48 V AC of 5 KVA capacity, double wound winding, input, output voltage meter, Voltage regulation 95% or above, Aluminum/ copper connector suitable for connection with 16/25/35 sq.mm aluminum cable, MCB complete with fixing arrangement, made out of 2 mm thick CRCA sheet with anti corrosive treatment, weather proof enclosure IP 65, indication lamp, foundation arrangement and anti theft arrangement as per site requirement & as per explanatory note. | — | 25.00 | — | — | |
| Supply, fixing, testing & commissioning of Thermoplastic PC-GFS Polycarbonate weatherproof junction box IP-67 (size 205 x 255 x 112 MM) weather proof UV resistant, rain waterproof, temperature resistant, flame retardant suitable for termination of 4C X 16/25/35 SQMM cable with earth terminal as well as loop-in / loop-out of cable. The junction box shall fulfill the following standards IEC 6067-22: Particular requirements for connecting boxes and enclosures. IEC 60695-2-11 : Flame - retardant & Self-extinguishing. Glow Wire tested at minimum 960 degree C. IEC 60529: IP 66 / IP 67 / IP 69 degree protection as per site requirement & as per explanatory note. | — | 200.00 | — | — | |
| Design, supply, fixing, testing and commissioning of floor mounted doubledoor distribution board outdoor type having IP-65 protection and made of thermoplastic polycarbonate (300x600x170mm), and polyurethane gasket (MCCB - Incoming & MCB- Outgoing) comprising with the following MCCB's and MCB's fixed in it of make ABB, Siemens, L&T, Schneider, Legrand or equivalent confirming IEC 606952-11, 60439-1, 60529 or latest, and as per IS, IE rules and site requirement. It should be rodant entry proof and also include well dressed and with circuit identification by using suitable ferrules & as per explanatory note. 4P MCCB 63Amps 36kA with adjustable thermal & fixed magnetic release = 01 No.(Incoming) MCB 63 Amps 5 pin industrial Socket IP67 along with plug complete for welding point= 01 Nos. (Outgoing) MCB16-20 Amps 5 pin industrial Socket IP 67 along with plug complete for welding point = 01Nos. (Outgoing). | — | 24.00 | — | — | |
| Supply, fixing, testing and commissioning of LT distribution board surface/recessed mounting double door out door type made up of CRCA sheet sheet with anti corrosion treatment and suitable, IP 43 phosphatised powder painted complete with neutral link, earth point, Din rail and prewired confirming to IEC 60947 or latest of make ABB, Siemens, L&T, Schneider, Legrand, or equivalent with following items of matching make to be fixed in distribution board, confirming to IEC 61439 or latest, IE rules and site requirement. It should be rodent entry proof. It should also include well dressing and coding of circuit & as per explanatory note. 63A 4P RCBO 30/100mA=01 No. (Incoming). 6-32A MCB SP 'C' series = 18 Nos. (Outgoing). It should be rodent entry proof. It should also include well dressing and coding of circuit IP2X terminal , reversible door with 180 degree opening, cement spill protection, detachable gland at top and bottom and short link for MCBs. It should also include proper tagging on electrical wires/cables which clearly indicate the incoming point or source and outgoing point of wires/cables. | — | 3.00 | — | — | |
| Design, Supply, fixing, testing and commissioning of front operated double door type weather proof feeder pillar body made of CRCA sheet sheet with anti corrosion treatment and suitable having IP 65 protection (MCCB - Incoming & MCCB - Outgoing) comprising with the following MCCB's fixed in it of make: Siemens, L&T, Schneider, Legrand or equivalent conforming to IEC 60947 or latest with digital measuring instrument & Al. bus-bar arrangement conforming to IS/IEC 61439 or latest and as per IS, IE rules and site requirement. It should be dust proof and vermin proof and powder coating and also provide polyamide cable gland with IP 68 protection & should suit the number, type and size of power cables & as per explanatory note. 4P MCCB 250Amps 36 kA with adjustable thermal & fixed magnetic release = 01 No. (Incoming) 4P MCCB 125Amps 36 kA with adjustable thermal & fixed magnetic release = 02 No. (outgoing) 4P MCCB 63Amps 36 kA with adjustable thermal & fixed magnetic release = 04 No. (outgoing) It should be rodent entry proof with proper entry and exit provision of cable so as to prevent entry of rodents and other unwanted material. | — | 3.00 | — | — | |
| Design, Supply, fixing, testing and commissioning of front operated double door type weather proof feeder pillar body made of CRCA sheet sheet with anti corrosion treatment and suitable having IP 65 protection (MCCB - Incoming & MCCB - Outgoing) comprising with the following MCCB's fixed in it of make: Siemens, L&T, Schneider, Legrand or equivalent conforming to IEC 60947-2 or latest with digital measuring instrument & Al bus-bar arrangement conforming to IS/IEC 61439 or latest and as per IS, IE rules and site requirement. It should be dust proof and vermin proof, and powder coating and also provide polyamide cable gland with IP 68 protection & should suit the number, type and size of power cables & as per explanatory note. a) 4P MCCB 400Amps 36 kA with adjustable thermal & fixed magnetic release =01 Nos. (Incoming). b) 4P 400 Amps on load change over switch (COS)=01 No. c) 4P MCCB 250Amps 36 kA with adjustable thermal & fixed magnetic release =04 Nos. (Outgoing). d) 4P MCCB 125Amps 36 kA with adjustable thermal & fixed magnetic release =04Nos. (Outgoing). It should be rodent entry proof with proper entry and exit provision of cable so as to prevent entry of rodents and other unwanted material | — | 4.00 | — | — | |
| Design, Supply, fixing, testing and commissioning of LT panel (ACB - Incoming & MCCB - Outgoing) comprising with the following ACB and MCCBs fixed in it of make ABB, Siemens, L&T, Schneider, Legrand or equivalent conforming to IEC 60947-2 or latest with digital measuring instrument & bus-bar arrangement confirming to IS/IEC 61439 or latest, IE rules and site requirement & as per explanatory note. a) 4P ACB 630 AMPs ACB with microprocessor release, display with trip data and RS 485 inbuilt port , neutral protection, Ics=Icu=50KA, Icw=1sec, MDO type =01 No. (Incoming). b) 4P MCCB 400Amps 36kA with adjustable thermal & fixed magnetic release =04Nos. c) 4P MCCB 250Amps 36 kA with adjustable thermal & fixed magnetic release =04 Nos. (Outgoing). d) 4P MCCB 125Amps 36kA with adjustable thermal & fixed magnetic release =04 Nos. (Outgoing). It should be dust proof and vermin proof, and powder coating and should suit the number, type and size of power cables. | — | 1.00 | — | — | |
| Earthing with 40 mm dia GI pipe class 'B' 4.5 meter long earth electrode as per IS:3043 (or latest version) including construction of masonry enclosures with hinged cover plate of cast iron with locking arrangement (approx. size 400 mm x 400 mm) on top, and water pipe etc with charcoal/coke and salt as required and provision of earth plate, connections from earth electrode to switch gear/pole as per drawing & as per explanatory note. | — | 39.00 | — | — | |
| Supplying and laying 25 mm X 5 mm G.I strip confirming to relevant IS as per IS:3043 (or Latest version), fixing on surface or as per site condition, clamping or fixing with suitable arrangement as per site requirement, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required & as per explanatory note. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50 mm) | — | 195.00 | — | — | |
| Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required & as per explanatory note. | — | 30.00 | — | — | |
| Fabrication of MS stand/cabinets or any other MS structure of approved drawing for precooling points/battery charger/ covering of electrical structure. The work includes cutting, welding , riveting, nut bolts of the MS structure including applying a primary coat of steel primer and one coat of paint of approved shade & as per explanatory note. | — | 100.00 | — | — | |
| Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground as per IS 1255 (Reviewed in 2016) or latest including excavation, sand cushioning, protective covering and refilling the trench [size width- not less than 35 cm and depth-(75-100) cm] etc. as required as per detail drawing approved by competent authority and conforming to CPWD General Specifications for Electrical Works Part-II External - 2023 and CPWD DSR (E&M) 2022 or latest & as per explanatory note. Upto 35 sq. mm | — | 600.00 | — | — | |
| Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground as per IS 1255 (Reviewed in 2016) or latest including excavation, sand cushioning, protective covering and refilling the trench [size width- not less than 35 cm and depth-(75-100) cm] etc. as required as per detail drawing approved by competent authority and conforming to CPWD General Specifications for Electrical Works Part-II External - 2023 and CPWD DSR (E&M) 2022 or latest & as per explanatory note. Above 35 sq. mm and upto 95 sq. mm | — | 600.00 | — | — | |
| Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground as per IS 1255 (Reviewed in 2016) or latest including excavation, sand cushioning, protective covering and refilling the trench [size width- not less than 35 cm and depth-(75-100) cm] etc. as required as per detail drawing approved by competent authority and conforming to CPWD General Specifications for Electrical Works Part-II External - 2023 and CPWD DSR (E&M) 2022 or latest & as per explanatory note. Above 95 sq. mm and upto 185 sq. mm | — | 800.00 | — | — | |
| Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground as per IS 1255 (Reviewed in 2016) or latest including excavation, sand cushioning, protective covering and refilling the trench [size width- not less than 35 cm and depth-(75-100) cm] etc. as required as per detail drawing approved by competent authority and conforming to CPWD General Specifications for Electrical Works Part-II External - 2023 and CPWD DSR (E&M) 2022 or latest & as per explanatory note. Above 185 sq. mm and upto 400 sq. mm | — | 180.00 | — | — | |
| Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground as per IS 1255 (Reviewed in 2016) or latest in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench [size width- not less than 55 cm and depth-(75-100) cm] etc as required as per detail drawing approved by competent authority and conforming to CPWD General Specifications for Electrical Works Part-II External - 2023 and CPWD DSR (E&M) 2022 or latest & as per explanatory note. Upto 35 sq. mm | — | 400.00 | — | — | |
| Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground as per IS 1255 (Reviewed in 2016) or latest in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench [size width- not less than 55 cm and depth-(75-100) cm] etc as required as per detail drawing approved by competent authority and conforming to CPWD General Specifications for Electrical Works Part-II External - 2023 and CPWD DSR (E&M) 2022 or latest & as per explanatory note. Above 35 sq. mm and upto 95 sq. mm | — | 200.00 | — | — | |
| Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground as per IS 1255 (Reviewed in 2016) or latest in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench [size width- not less than 55 cm and depth-(75-100) cm] etc as required as per detail drawing approved by competent authority and conforming to CPWD General Specifications for Electrical Works Part-II External - 2023 and CPWD DSR (E&M) 2022 or latest & as per explanatory note. Above 95 sq. mm and upto 185 sq. mm | — | 300.00 | — | — | |
| Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground as per IS 1255 (Reviewed in 2016) or latest in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench [size width- not less than 55 cm and depth-(75-100) cm] etc as required as per detail drawing approved by competent authority and conforming to CPWD General Specifications for Electrical Works Part-II External - 2023 and CPWD DSR (E&M) 2022 or latest & as per explanatory note. Above 185 sq. mm and upto 400 sq. mm | — | 60.00 | — | — | |
| Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. In case of any demolition of PCC, RCC, road, wall surface etc. the contractor should ensure repairing of the same on own expenses as per site requirement and satisfaction of railway representative conforming to IS 1255 (Reviewed in 2016) or latest and conforming to CPWD General Specifications for Electrical Works Part-II External - 2023 and CPWD DSR (E&M) 2022 or latest & as per explanatory note. Upto 35 sq. mm (clamped with 1mm thick saddle) | — | 2500.00 | — | — | |
| Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. In case of any demolition of PCC, RCC, road, wall surface etc. the contractor should ensure repairing of the same on own expenses as per site requirement and satisfaction of railway representative conforming to IS 1255 (Reviewed in 2016) or latest and conforming to CPWD General Specifications for Electrical Works Part-II External - 2023 and CPWD DSR (E&M) 2022 or latest & as per explanatory note. Above 35 sq. mm and upto 95 sq.mm (clamped with 25x3mm MS flat clamp) | — | 200.00 | — | — | |
| Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. In case of any demolition of PCC, RCC, road, wall surface etc. the contractor should ensure repairing of the same on own expenses as per site requirement and satisfaction of railway representative conforming to IS 1255 (Reviewed in 2016) or latest and conforming to CPWD General Specifications for Electrical Works Part-II External - 2023 and CPWD DSR (E&M) 2022 or latest & as per explanatory note. Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp) | — | 300.00 | — | — | |
| Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. In case of any demolition of PCC, RCC, road, wall surface etc. the contractor should ensure repairing of the same on own expenses as per site requirement and satisfaction of railway representative conforming to IS 1255 (Reviewed in 2016) or latest and conforming to CPWD General Specifications for Electrical Works Part-II External - 2023 and CPWD DSR (E&M) 2022 or latest & as per explanatory note. Above 185 sq. mm and upto 400 sq. mm (clamped with 25/40x3mm MS flat clamp) | — | 60.00 | — | — | |
| Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. as per IS/IEC 61537: 2024 or latest and conforming to CPWD General Specifications for Electrical Works Part-II External - 2023 and CPWD DSR (E&M) 2022 or latest & as per explanatory note. 150 mm width X 50 mm depth X 1.6 mm thickness | — | 600.00 | — | — | |
| Supply, laying, testing & commissioning of 160 mm dia HDPE pipe (PE-100, PN-6) conforming to IS:4984 or latest, for cable laying by trenchless Horizontal Directional Drilling (HDD) method as per IS:1255, IE Rules, CPWD and Indian Railways specifications, including detailed route survey, marking of alignment, pilot drilling, reaming, supply and laying of pipe by pull-back method with butt fusion/electrofusion jointing, use of suitable drilling fluid, and maintaining required depth and alignment (generally 1.5 m to 3.5 m or as directed). The work shall include preparation and submission of complete HDD report comprising route alignment drawings with chainage and coordinates of entry/exit points, section-wise details of HDD lengths, depth profile graphs (depth vs chainage), HDD logs, and photographic records, as per site requirements. The item also includes testing, quality assurance, protection of existing utilities, disposal of slurry, restoration of site, and all incidental works complete in all respects as directed by Engineer-in-Charge & as per explanatory note. | — | 100.00 | — | — |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
ExplanatoryNote.pdf
ATTACHMENT
TenderDocument.pdf
ATTACHMENT
SpecialConditionsofContract.pdf
ATTACHMENT
GCC-2022-ACS10_merged.pdf
ATTACHMENT
GCCAdvanceCorrectionSlipNo.11.pdf GCC ACS No 11
ATTACHMENT
TECHSPEC-I.pdf
ATTACHMENT
TECHSPEC-II.pdf
ATTACHMENT
GCCAdvanceCorrectionSlipNo.11.pdf
ATTACHMENT
ModifiedExplanatoryNote_1.pdf
CORRIGENDUM
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .