Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.7 CrAdmitted-Finance | ₹9.7 Cr | L1 | Admitted-Finance |
| 2 | L2₹11.2 CrAdmitted-Finance MANATHA ENCLAVE 3RD FLOOR OLIMUGAL KAKKANAD P O KOCHI 682 030 KERALA | ERNAKULAM | KERALA | 682030 | ₹11.2 Cr | L2 | Admitted-Finance |
| 3 | Rejected-Technical | - | - | Rejected-Technical Adverse remarks in WLR |
| Sl No | Description | Qty | Unit | SUNDER BUILDERS L1 | Mecone Construction Contractors L2 |
|---|---|---|---|---|---|
| 1.00GENERAL SUMMARY ( PHASE-I) NOTE: Schedule ‘A’ Part - I to XIII are prepriced by MES under Ser No. 2.00 to 14.00. Bidders shall insert their lumpsum amount in the Green coloured field under Col-7 only. | |||||
| 2.00 | Lumpsum price worked out by the contractor for “BUILDINGS / STRUCTURES ” as listed in Schedule ‘A’ Part - I , | 1 | Lumpsum | 4,88,00,000 ₹4.9 Cr | 5,48,50,000 ₹5.5 Cr |
| 3.00 | Lumpsum price worked out by the tenderer for "SITE CLEARANCE / SITE DEVELOPMENT/ EARTH WORK/ EXCAVATION" as listed in Schedule ‘A’ Part-II | 1 | Lumpsum | 7,00,001 ₹7.0 L | 7,75,000 ₹7.8 L |
| 4.00 | Lumpsum price worked out by the tenderer for "DEMOLITION / DISMANTLING" as listed in Schedule ‘A’ Part-III | 1 | Lumpsum | 4,00,000 ₹4 L | 4,30,000 ₹4.3 L |
| 5.00 | Lumpsum price worked out by the tenderer for "INTERNAL ELECTRIFICATION" as listed in Schedule ‘A’ Part-IV | 1 | Lumpsum | 12,00,000 ₹12 L | 13,28,000 ₹13.3 L |
| 6.00 | Lumpsum price worked out by the tenderer for "INTERNAL WATER SUPPLY " as listed in Schedule ‘A’ Part-V | 1 | Lumpsum | 25,000 ₹25,000 | 40,000 ₹40,000 |
| 7.00 | Lumpsum price worked out by the tenderer for "ROAD/PATH/HARD STANDING/CULVERT " as listed in Schedule ‘A’ Part-VI | 1 | Lumpsum | 25,50,000 ₹25.5 L | 28,40,000 ₹28.4 L |
| 8.00 | Lumpsum price worked out by the tenderer for "SEWAGE DISPOSAL " as listed in Schedule ‘A’ Part-VII | 1 | Lumpsum | 1,50,000 ₹1.5 L | 1,75,000 ₹1.8 L |
| 9.00 | Lumpsum price worked out by the tenderer for "EXTERNAL WATER SUPPLY " as listed in Schedule ‘A’ Part-VIII | 1 | Lumpsum | 2,00,000 ₹2 L | 2,40,000 ₹2.4 L |
| 10.00 | Lumpsum price worked out by the tenderer for " EXTERNAL ELECTRIFICATION " as listed in Schedule ‘A’ Part-IX | 1 | Lumpsum | 7,25,000 ₹7.3 L | 8,10,000 ₹8.1 L |
Updated dates
Tender Value
₹9.0 Cr
EMD Value
₹7.8 L
Closing Date
19 Feb 2026, 6:00 pmClosed
CWE NAVY CHENNAI
Commander Works Engineers Navy Military Engineer Services Fort St George Rajaji Salai Chennai600 009
82691 PROVISION OF DEFICIENT BULK STORE HOUSE AT NSD CHENNAI UNDER GE NAVY CHENNAI
2025_MES_746526_1
CWE/NAVY/CHN/82691/E8 OF 2025-26
Open Tender
Civil Works
540 days
Chennai
As per NIT
9 documents required · 9 mandatory
₹3,000
GE Navy Chennai
₹7.8 L
Yes
5 Mar 2026
30 Dec 2025
21 Feb 2026
30 Dec 2025
19 Feb 2026
31 Jan 2026
30 Dec 2025 - 5 Jan 2026
GENERAL SUMMARY ( PHASE-I) NOTE: Schedule ‘A’ Part - I to XIII are prepriced by MES under Ser No. 2.00 to 14.00. Bidders shall insert their lumpsum amount in the Green coloured field under Col-7 only.
Lumpsum price worked out by the contractor for “BUILDINGS / STRUCTURES ” as listed in Schedule ‘A’ Part - I ,
Lumpsum price worked out by the tenderer for "SITE CLEARANCE / SITE DEVELOPMENT/ EARTH WORK/ EXCAVATION" as listed in Schedule ‘A’ Part-II
Lumpsum price worked out by the tenderer for "DEMOLITION / DISMANTLING" as listed in Schedule ‘A’ Part-III
Lumpsum price worked out by the tenderer for "INTERNAL ELECTRIFICATION" as listed in Schedule ‘A’ Part-IV
Lumpsum price worked out by the tenderer for "INTERNAL WATER SUPPLY " as listed in Schedule ‘A’ Part-V
Lumpsum price worked out by the tenderer for "ROAD/PATH/HARD STANDING/CULVERT " as listed in Schedule ‘A’ Part-VI
Lumpsum price worked out by the tenderer for "SEWAGE DISPOSAL " as listed in Schedule ‘A’ Part-VII
Lumpsum price worked out by the tenderer for "EXTERNAL WATER SUPPLY " as listed in Schedule ‘A’ Part-VIII
Lumpsum price worked out by the tenderer for " EXTERNAL ELECTRIFICATION " as listed in Schedule ‘A’ Part-IX
Lumpsum price worked out by the tenderer for " FIRE FIGHTING " as listed in Schedule ‘A’ Part-X
Lumpsum price worked out by the tenderer for " LIGHTENING PROTECTION " as listed in Schedule ‘A’ Part-XI
Lumpsum price worked out by the tenderer for " LIFT" as listed in Schedule ‘A’ Part-XII
Lumpsum price worked out by the tenderer for " PILE FOUNDATION " as listed in Schedule ‘A’ Part-XIII
SCHEDULE "A" PART - XIV MISCELLANEOUS ITEMS NOTE: Schedule ‘A’ Part - XIV is not prepriced by MES and prepriced rate indicated as 0.00 under Col.5 signifies this fact only. Bidder shall insert their rates in Green colour filled under Col-7.
Taking down old sub main wiring any type as specified and directed.
Taking down old fan and depositing to MES store yard all as directed.
Taking down pipe line of any size all as directed.
Point wiring with 1.5 sqmm FRLSH PVC insulated and unsheathed copper conductor multistranded 1100 volts grade, ISI marking drawn thorugh and inculding non metallic PVC rigid concealed conduit and conduit accessories, medium grade, ISI marking, concealed including one run of 1.5 sqmm PVC insulated unsheathed copper cable for earth continuity, connected to earth duly complete all as specified and directed for the following:
One light point controlled by one switch
One bell point controlled by one regulator/switch
One fan (Ceiling/Wall/Exhaust fan) point controlled by one switch
All as per item No. 19 above but for One 3 pin socket outlet 5 amps socket on independent board with 2.5 sqmm FRLS PVC wire and one run of 2.5 sqmm copper cable for earth continuty.
All as per item No. 19 above but for One 3 pin socket outlet 15 amps socket on independent board with 4.0 sqmm FRLS PVC wire and one run of 4.0 sqmm copper cable for earth continuty.
Supply & fix Modular Metal flush Box 8 Module complete all as specified and directed.
Material and labour for Sub main wiring with four runs single core 10 sqmm FRLSH multi stranded copper conductor PVC insulated unsheathed cable 1100 volts grade and two runs of 10 sqmm multi stranded copper conductor cable as earth continuity conductor drawn into and including non-metalic rigid PVC conduit, 32 mm dia and conduit accessories concealed/surface of wall/roof/ceiling etc complete all as specified and directed. Note: Four runs of 10sqmm for phase & neutral and two runs of 10 sqmm cable for earth continuity and one run of 32 mm dia conduit shall be measured as one unit length.
Material and labour for Sub main wiring with four runs single core 6 sqmm FRLSH multi stranded copper conductor PVC insulated unsheathed cable 1100 volts grade and two run of 6 sqmm multi stranded copper conductor cable as earth continuity conductor drawn into and including non-metallic rigid PVC conduit 32 mm dia/PVC casing capping 32 mm including conduit accessories all as specified and directed. Note: Four runs of 6 sqmm for phase & neutral and two runs of 6 sqmm cable for earth continuity and one run of 32 mm dia conduit shall be measured as one unit length.
Material and labour for Sub main wiring with two runs single core 6 sqmm FRLSH multi stranded copper conductor PVC insulated unsheathed cable 1100 volts grade and one run of 6 sq mm multi stranded copper conductor cable as earth continuity conductor drawn into and including non-metallic rigid PVC conduit 25 mm dia including conduit accessories all as specified and directed. Note: Three runs of 6 Sqmm cable and one run of 25 mm conduit will be measured as one unit length.
Material and labour for Sub main wiring with two runs single core 4 sqmm FRLSH multi stranded copper conductor PVC insulated unsheathed cable 1100 volts grade and one run of 4 sq mm multi stranded copper conductor cable as earth continuity conductor drawn into and including non-metallic rigid PVC conduit 20 mm dia including conduit accessories all as specified and directed. Note: Three runs of 4 Sqmm cable and one run of 20 mm conduit will be measured as one unit length.
Material and labour for Sub main wiring with two runs single core 2.5 sqmm FRLSH multi stranded copper conductor PVC insulated unsheathed cable 1100 volts grade and one run of 2.5 sq mm multi stranded copper conductor cable as earth continuity conductor drawn into and including non-metallic rigid PVC conduit 20 mm dia including conduit accessories all as specified and directed. Note: Three runs of 2.5 Sqmm cable and one run of 20 mm conduit will be measured as one unit length.
Material and labour for Sub main wiring with two runs single core 1.5 sqmm FRLSH multi stranded copper conductor PVC insulated unsheathed cable 1100 volts grade and one run of 1.5 sq mm multi stranded copper conductor cable as earth continuity conductor drawn into and including non-metallic rigid PVC conduit 20 mm dia including conduit accessories all as specified and directed. Note: Three runs of 1.5 Sqmm cable and one run of 20 mm conduit will be measured as one unit length.
Supply and fix sheet metal enclosure powder coated double door for Distribution Board, VTPN 4 way DB suitable for MCCB incomer with IP 43 - IK 09 complete all as specified and as directed.
Supply and fix sheet metal enclosure powder coated double door for Distribution Board, VTPN 6 way DB suitable for MCB incomer with IP 43 - IK 09 complete all as specified and as directed.
Supply and fix sheet metal enclosure powder coated double door for Distribution Board, VTPN 4 way DB suitable for MCB incomer with IP 43 - IK 09 complete all as specified and as directed.
Supply and fix MCCB 4 pole 415 volts , 125 Amps, with rupturing capacity 16 KA complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix MCCB 4 pole 415 volts , 63 Amps, with rupturing capacity 16 KA complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix Heavy Duty Wall Mounting Air Circulator fan 450 mm (18 ") , Air Delivery (CMM) - 150 , Power Consumption - 100 W, Speed 1440 RPM complete all as specified and directed by Engg - in - Charge
S & F GI bracket made out of 32 mm dia GI pipe length 1.50m, bent to an angle of 30 degree and fixed with 40mm x 6mm flat iron, including suitable 02 set of clamps with nut , bolts ,and washers for fixing of light to pole complete all as specified and as directed.
M & L for earthing complete with GI earth plate electrode 60cm×60cm× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to 32x6 mm galvanised iron strip as earthing lead by means of bolts, nuts, check nuts and washers of copper all as shown in electrical plate No.3 in SSR part 1 (2010 edition) connected to earthing test point,including 20 mm GI pipe (Medium grade) for watering and 40 mm GI pipe (Medium grade) for protection of earth strip etc.. including testing on completion ,PCC chambers in PCC1:3:6 type C1, RCC M25 cover slab 50mm thick with 8mm dia TMT HCR/CRS steel bars at 140mm C/C both way and lifting handle GI funnel & wiremesh ,funnel,lugs and charcoal,salt etc all as applicable complete all as specified and as directed by the Engineer-in-Charge. Note:-(i) The rates quoted is inclusive of 32x6mm galvanised iron strip earth conductor upto a length of 7.5m from the earth pit.
M & L for earthing complete with GI earth plate electrode 60cm×60cm× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to 4.0 mm galvanised iron wire as earthing lead by means of bolts, nuts, check nuts and washers of copper all as shown in electrical plate No.3 in SSR part 1 (2010 edition) connected to earthing test point,including 20 mm GI pipe (Medium grade) for watering and 15 mm GI pipe (Medium grade) for protection of earth wire and etc.. including testing on completion ,PCC chambers in PCC1:3:6 type C1, RCC M25 cover slab 50mm thick with 8mm dia TMT HCR/CRS steel bars at 140mm C/C both way and lifting handle GI funnel & wiremesh ,funnel,lugs and charcoal,salt etc all as applicable complete all as specified and as directed by the Engineer-in-Charge. Note:-(i) The rates quoted is inclusive of 4.0mm galvanised iron wire earth conductor upto a length of 7.5m from the earth pit.
Supply and fix rigid non-metalic concealed PVC conduit inclusive of tees, bend etc and fixing all accessories of 20 mm dia concealed in walls/roof etc.
Supply and fix PVC junction box concealed complete of 1 to 4 way size 20mm dia all as directed.
Supply and fix Tele sockets of suitable type complete all as specified and directed .
Supply and fix ball/foot valve 200 mm dia with flanged end with strainer, Body-Cast Iron ,Ball-Nitrile Rubber Coated ,Seat Ring-Nitrile, Fastener-Carbon Steel CL4, Adaptor-Cast Iron, Pressure rating 25 - 100NB PN 6 complete all as specified and directed .
Supply and fix ball/foot valve 80 mm dia with flanged end with strainer., Body-Cast Iron ,Ball-Nitrile Rubber Coated ,Seat Ring-Nitrile, Fastener-Carbon Steel CL4, Adaptor-Cast Iron, Pressure rating 25 - 100NB PN 6 complete all as specified and directed .
Supply and fix ball/foot valve 25 mm dia with flanged end with strainer, Body-Cast Iron ,Ball-Nitrile Rubber Coated ,Seat Ring-Nitrile, Fastener-Carbon Steel CL4, Adaptor-Cast Iron, Pressure rating 25 - 100NB PN 6 complete all as specified and directed .
Supply and fix Y- Strainer 200 mm ,Ductile Iron body, 300 psi, Flanged ends ANSI, UL Listed, complete all as specified and directed .
Supply and fix Y- Strainer 80 mm dia, Ductile Iron body, 300 psi, Flanged ends ANSI, UL Listed complete all as specified and directed .
Supply and fix Air release valve dia 40 mm /25 mm, dia of gunmetal body complete all as specified and as directed by the Engineer-in- Charge.
Supply and fix Self priming pump 0.5 HP , Single Phase , Suction & Deilvery size - 25 mm, Discharge- 2439 LPH, Head - upto 34 m including foundation and making necessary pipe connection at suction and delivery side complete all as specified and as directed by the Engineer-in-Charge.
S&F control panel. 60HP, to automatic and manual controlling of following pumps : Electrial driven hydrant main motor (01 No.), & Jockey pump Electrical driven (01 Nos ) and diesel Engine (01 No.) , Priming Pump Electrical driven (01 No.) complete all as specified and as directed by the Engineer-in-Charge. Note : 1. The system shall be designed for operation automatically so that as and when water is drawn from the system through any hydrant / sprinkler , the pumps will operate automatically and feed water in to the system. However once a fire pump starts working, it will be stopped only manually (except jockey pump). 2. The control system shall be designed to provide the following sequence of operation: i) The Pressurization Pump shall maintain pressure in the system and shall operate only on account of slow pressure loss. In case of sudden pressure loss the Pressurization Pump shall not operate. The pump shall start when the water pressure in the system falls to a pre-set value (about 0.35 kgf/cm2 below normal system pressure) and shut down when the system pressure reaches the set value. Both limits shall be adjustable. ii) Main Electric Fire Pump / Sprinkler pump shall operate on account of sudden pressure loss. So long as Main Electric Fire Pump is working, other Fire Pumps will not operate. The pump shall start when the water pressure falls to a pre-set value in the system (about 1 kgf/cm2).In case, Normal Electric Supply fails while the Main Electric Fire Pump is running, the DG Set for essential supply will start within 5 seconds.
Item No.47 Conte… iii) The Diesel Fire Pump will start on sudden pressure loss, only in case supply to Main Electric Fire Pump is not available or within a pre-set time the Main Electric Fire Pump fails to start or fails during operation. No other pump will be working when Diesel Engine Fire Pump is in operation. Audio-Visual Alarm shall be available to indicate failure of Main Electric Fire Pump. iv) A three attempts starting facility will be provided for diesel pump. v) If within a pre-set time, the standby pump also fails to start or fails to develop pressure, the standby pump shall also be shut down and locked out. An audio visual alarm indication shall be given at the control panel. vi) In case sprinkler pump is also provided : a) Sprinkler pump will start on pressure loss (about 1 kgf/cm2) in the sprinkler header. b) If sprinkler pump does not start in preset time or fails during operation, the main electric fire pump shall start and feed water to sprinkler system. c) Diesel pump will start and feed water only in case supply to main electric pump is not available or within a preset time the main electric pump fails to start or fails during operation. No other pump will be working when diesel pump is in operation. Audio-visual alarm shall be available to indicate failure of both sprinkler and main electric pump. viii) Only one pump will be working at a time. In manual mode more than one pump can be started. An audio-visual alarm shall be given at the control panel.
M& L for painting MS Pipe with a coat of primer of red oxide paint and finished with two coats of synthetic enamel paint,complete all as specified and as directed.
M & L for wrapping 4 mm thick PYPKOTE Pipe Wrapping Coating for Corrosion protection conforming to the requirement of IS : 10221 and applying a final coat of bitumastic paints for anti rust protection for GI pipe laid in trench.Holiday Testing for wrapping and coating is essential. Holiday testing may preferably be carried by flexible and detachable ring probe, which will enable the entire 360 degree of the surface of the pipe to be scanned. Note : Before application of corrosion protection tape all foreign matter on pipe shall be removed with the help of wire brush and suitable primer shall be applied over the pipe thereafter. The primer shall be allowed to dry until the solvent evaporates and the surface becomes tacky. Both primer and tape shall be furnished by the same manufacturer. Corrosion protection tape shall then be wound around the pipe in spiral fashion and bounded completely to the pipe. There shall be no air pocket or bubble beneath the tape. The overlaps shall be 15 mm and 250 mm shall be left uncoated on either end of pipe to permit installation and welding. This area shall be coated insitu after the pipe line is installed. The tapes shall be wrapped in accordance with the manufacturer’s recommendations.
Supply and fix Pressure reducing device to control pressure not to exceed 7 kgf/ cm2 Bib Nose type ,Made of Gunmetal, Having 3” Flanged inlet & 2.1/2” female instantaneous bib nose type outlet as per BS: 336, Spindle made of brass, & C.I hand wheel, Complete with ABS blank cap & SS chain, Flange dimensions as per ANSI # 150 class FM Approved Complete all as directed
Supply and fix hose, reinforced rubber lined (RRL) all synthetic fiber circular woven jacketed, EPDM synthetic rubber lining fire hose, working pressure 14kg/cm2, proof pressure 22kg/cm2, burst pressure 38kg/cm2, bearing IS: 636-2018 Type-1, in 30mtr length, 63mm dia., duly bound with SS-304 Coupling, 63mm size, pair of male & female parts, inst. type, bearing IS: 903 mark – SS wire binding Complete all as directed
Supply and fix Zonal Control Assembly 80mm consisting of one no. each following items : (1) Butterfly Valve 3" (Wafer Type) with Micro Switch & Position indicator; 300PSI Rating. UL Listed & FM Approved. , (2) Water Flow Detector 3"- Flow Switch (UL/FM), (3) Pressure Relief Valve , Factory rated at 175 PSI. Size 1/2 inch, UL Listed & FM Approved, (4) Test and Drain Valve, 1 inch NPT, UL & FM Approved, (5) Pressure Gauge , 1/4 inch BSPT, 0-300PSI, 3.5 inch Dial, UL & FM Approved with ball valve, (6) Manifold - C.S. and (7) Hose Assembly - Stainless steel braided and connecting to Sprinker pipe system , wetriser pipe and drain pipeline complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix Fire alarm control panel complying with BS EN 54 2 loop panel with 99 detectors & 99 modules & upto 200 detectors and modules (per each loop). The addressable Fire Alarm Control Panel (FACP) shall function as a network panel & also as a fully stand alone panel.Note : The FACP should have integrated power distribution module and fixed cabling done internally to guarantee a clear and tidy cable feed (c) The panel should have an LCD display with minimum 300 characters and keypad. The Display should enable a flexible design of the operating menu with variable keys and message windows fixed keys should be used for standard operating steps e.g. for fire alarm securities supervisory trouble and other events. The current status of the system should be displayed by LED's interfaces (RS232) enable the connection to a PC.FACP switches shall allow authorized personnel to accomplish the following, independent of the central console. (a) Acknowledge a general alarm condition. (b) Silence the local audible alarm. (c) It shall be possible to silence the alarm indicating devices (hooters). (d) Reset all zones (logical Point Group) / points, after all initiating devices have returned to normal. (e) Perform a complete operational test of the memory with a visual indication.(f) Test all panel LED's for proper operation without causing a change in the condition of any zone (Logical Point Group). (g) Walk test –The system shall provide both a basic and advanced walk test for testing the entire fire alarm system including testing of all devices, detectors module etc. in the complete system.
Power supply unit of FACP shall have following characters: (a) The main power supply shall be 230V AC ±10% 50Hz ± 3% and shall in turn provide all necessary power of FACP. (b) It shall provide a separate battery control module with charger. The battery should last for 24 hours minimum in normal operation upon power failure & 30 minutes in alarm condition. (c) For ease of service, all wiring terminal blocks shall be plug-in type. (d) The fire alarm panels shall have a possibility of being interlinked by direct connectivity or an optical cable link between the various locations and should further have connectivity to the main control center.
Supply and fix Mild Steel Annunciation Panel (LED display) with zone identification facility & both audio and visual alarm complied with EN54-2 & EN54-4 Standards and making necessary control connections . Note : In the event of operation of sprinkler(s) in an affected area,( Water flow switches shall be installed in main distribution pipes which shall be wired to sprinkler annunciation panel.)the annunciation panel shall give audio-visual alarm and indicate the affected zone. This arrangement will be independent of fire alarm system.
Supply and fix Analogue Addressable Fire Alarm Repeater Panel and shall duplicate the alarm indications (audio as well as visual) of the Main Fire alarm panel. Operating Voltage 24VDC, UL listed (9th Edition), 32 bit processor, Construction: 18 Gauge (1.22 mm) CRCA sheet with powder‐coated Finish, RS 485 : Baud rate 19200. Connector RS 485 Cable Length 1200m (Twisted pair cable recommended) Fire Relays : Type Form C, No of Relays 1, Relay contact rating 2A @ 30 VDC, 0.5A @ 125 VAC with following features :- Touch Keypad., 160 (40X4) character LCD Display, 2000 Event with Real Time Clock, RS 485 communication for Network / Repeater, One form C relay for fire, Extensive built in transient protection, Lamp test facility. Common fire, supervisory, fault LED indication complete all as specified and as directed by the Engineer-in-Charge.
M&L for 2 core of 1.5 Sq.mm. Fire Survival Armoured Cable 600/1000 Volts Grade, Circular Stranded Plain Annealed Bare Copper Conductor, Two Layers Of Glass Mica Tapes Wrapped, XLPE Insulation, Cores Laid Up Together, Extruded LSZH Inner Sheathed, Galvanised Steel Round Wire Armoured, Extruded LSZH Compound .Outer sheath colour: Red , drawn through steel conduit heavy duty including mounting with all accessories complete all as specified and as directed by the Engineer-in-Charge.
S&F Powder Fire Extinguisher (Stored Pressure type) Capacity 06 Kg duly ISI marked conforming to IS: 15683:2018, HLD (Helium Leak Detection) Tested, with UL Listed MAP 90% ABC powder complete with squeeze grip release valve, discharge pipe, locking arrangement, pressure gauge, operation manual and bracket. Operating Temperature: -30 degree C to + 60 degree C. complete all as specified and as directed by the Engineer-in-Charge.
S&F CO2 type Fire Extinguisher ISI marked conforming to IS: 15683. Capacity 4.5 Kg. complete with delivery hose horn, wheel type release valve, locking arrangement, operation manual and bracket. Operating Temperature: - 30 degree C to +60 degree C. complete all as specified and as directed by the Engineer-in-Charge.
S&F Water Fire Extinguisher Stored pressure type ISI marked conforming to IS: 15683. Capacity 9 litre. complete with delivery hose, squeeze grip release valve, locking arrangement, pressure gauge, operation manual and bracket. Operating Temperature: +5 degree C to + 60 degree C. complete all as specified and as directed by the Engineer-in-Charge.
Supply and installation LT Electric control panel , cubical type, for outdoor use floor mounted made out of CRCA outer sheet of 3.15 mm thick and inner sheet of 2 mm thick and angle iron legs of size 50mmx50mmx5mm having front and rear open hinged doors with front openable shutters for each MCCB with spreader with fully enclosed bus bar chamber, having insulated bas bar made out of aluminium strips of rating 200 amps for 3 phase, 415 volts, 50 C/S 4 wire system, with cable entry provision, with suitable lugs gland, voltmeter , Ammeter,CTs and phase indicator complete, duly painted with two coats of stove enameled powder coated paint over a coat of red oxide primer complete and nut,bolt,washers for connection of cable, including necessary PCC work of height 45 cm from ground level and white washing to the platform all as specified and equipped with the following items :- INCOMER I.MCCB, 4pole, 80 Amps , rupturing capacity 16 KA - 01 Nos. II. Multifunction meter - 01 No III. LED Indicator lamp in three colour RYB - 03 Nos (L&T) OUT GOING I.MCCB, 4 pole, 16-63 Amps , rupturing capacity 16 KA - 04 Nos II. DOL Starter 3 phase upto 7.5 HP Pump - 02 No . (For operation of Terrace Pump. One to be erected at terrace and other one at Ground level )
Supply and fix Photoluminescence Emergency Glow signage, With Acrylic Base Single Side as specified and directed by Engineer in Charge
Supply and fix Photoluminescence Emergency Glow signage, With Acrylic Base double Side as specified and directed by Engineer in Charge
Supply and fix brass double compression cable gland with bright nickel plated finish , weather proof , with sealing ring made of Neoprene/Nitrile/Natural Rubber, IP 67 , size of the gland suitable for cable size 3 C x 70 sqmm (54-61 mm dia) complete
Supply and fix brass double compression cable gland with bright nickel plated finish , weather proof , with sealing ring made of Neoprene/Nitrile/Natural Rubber, IP 67 , size of the gland suitable for cable size 3 C x 25 sqmm (46-52 mm) dia complete
Supply and fix brass double compression cable gland with bright nickel plated finish , weather proof , with sealing ring made of Neoprene/Nitrile/Natural Rubber, IP 67 , size of the gland suitable for cable size 2 C x 4 sqmm (6-12 mm) dia complete
Supply, installation,commissioning of Water cooler fully stainless steel, electric driven single phase having approx storage and nominal cooling capacity 40/80 Ltrs as specified and directed by Engineer in Charge
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 150 V to 280 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 1.0 KVA as specified and directed by Engineer in Charge
Supply , install , commissioning and testing of Air Cooled Packaged Air Conditioners, comprising of Hermetic/Semi - Hermetically sealed Reciprocating or Hermetically sealed Scroll Compressors with microprocessor based control, including copper refirgerant piping, electrtical interconnection between indoor and outdoor units , suitable for operation on R - 22/R - 407c/R - 410a refrigerants and of nominal capacity 3 x 16.5TR (2W+1s) as specified and directed by Engineer in Charge
Supply , assembly and erection of GI sheet withTDF flange rectangular/square duct made out of 'L' shaped hollow profile, duly factory boxed, incl all accessories such as Corner, Cleat, Carriage bolt, Gasket and appropriate sealant on longitudinal joints etc complete of size 22 Gauge as specified and directed by Engineer in Charge
M&L for duct insulation with resin bonded fibre glass wool roll of density 24 kg/Cum, with factory laminated aluminium vapour barrier, thickness of insulation not less than 25 mm and including the following:- (a) M&L for cleaning the duct surface (to be insulated ) by scrapping carefully with wire brush etc. to make the surface completely free of millscale, dirt dust, grease and other foreign materials, taking special care so that all duct joints are sealed against any leakage. (b) M&L for applying rubber based adhesive CPRX compound. (c) M&L for sealing of all longitudinal joints and circular overlaps with and including Aluminium foil tape 50 mm wide, to make the insulation leakproof. (d) M & L for securing the insulation with and including mechanically fastened nylon/ steel straps of size 12 mm/50 mm at maximum intervals of 1.2 mtr.
Supply and installation LT Electric control panel , cubical type, for indoor use floor mounted made out of CRCA outer sheet of 3 mm thick and inner sheet of 2 mm thick and angle iron legs of size 50mmx50mmx5mm having front and rear open hinged doors with front openable shutters for each MCCB with spreader with fully enclosed bus bar chamber, having insulated bas bar made out of aluminium strips of rating 400 amps for 3 phase, 415 volts, 50 C/S 4 wire system, with cable entry provision, with suitable lugs gland, voltmeter , Ammeter,CTs and phase indicator complete, duly painted with two coats of stove enameled powder coated paint over a coat of red oxide primer complete and nut,bolt,washers for connection of cable, including necessary PCC work of height 45 cm from ground level and white washing to the platform all as specified and equipped with the following items :- (AC plant Panel, Loc :Plant Room). INCOMER: I.MCCB, 4pole, 160 Amps , rupturing capacity 36 KA - 01 Nos. II. Multifunction meter Make : L&T Cat part No: WL441010OOOO - 01 No III. LED Indicator lamp in three colour RYB - 03 Nos (L&T) OUTGOING: I.MCCB, 4pole, 63 Amps ,with breaking capacity 16 KA - 05 Nos
Supply , Installation , testing and commmisioning of outdoor type 11 KV Compact Sub Station comprising of 1 way , 11 KV ,630 Amps VCB in SF6 insulated stainless steel enclosure,HT Cable/Bus bar ,1 No transformer 315 KVA,11KV/433 CRT dry type & 4 Pole ,630 A, ACB , 415 V , Manual drawout type , including foundation as recommended by OEM complete all as specified and directed. The detailed specification are mentioned below.HT Section : VCB-Non-Extensible 1 way, 11KV, 1 SF6 circuit breaker along with connected accessories etc. Type: - Free Standing, Metal Clad, SF6 insulated Ringmaster with 01 no. Direct Cable Module & 01 no. 630A Fixed Manual SF6 Circuit breaker a. Self Powered Relay, Type IDMT b. Ring Switches and T OFF SF6 circuit breaker with Integrated Earthing Switches c. Live Cable Indicator for Ring Switches d. Padlocking facility e. Shunt trip coil rating – 230V AC f. Padlocking facility Transformer Section : 315 KVA, 11/0.433 KV, Copper Wound Dry Type Cast Resin Step Down Transformer having 5 Position Off Circuit Tap Links of +5% to -5% in steps of 2.5% each with all standard fittings & accessories including Digital Type WTI with Alarm& trip contacts & RTD Sensors as per IS-2026 (Part-11)/IS : 11171. Total Losses @50% Load –2000W,Total Losses @100% Load –5040W
Item No.72 cont.... LT Section : LT Panel comprising of LV Side Incomer- 01 No. - 630 Amp 4 Pole 415V 35KA Fixed type ACB , manual drawout ,microprocessor based release with O/L, S/C & E/F Protection. RYB Indication Lamp,Ammeter , 630A/5A LTCT Cl:1.0, Voltmeter Enclosure: Space Heater with ON/OFF Switch and Thermostat, Single phase switch with socket, LT Cubical illumination Lamp with Door Limit switch and MCB’s for AC / DC Control , MS Steel Sheet enclosure suitable for Outdoor Installation with MS base channel and PCC foundation , Provision for receiving Incoming cables through Bottom entry and out going through Bus bar to Trf panel, ,Provision for receiving Incoming through bus duct by bus bar and Outgoing through cable box bottom entry . Bus Bar – Aluminium , Earth Bus – Aluminium , Paint shade: Siemens Grey ( RAL 7032)
Supply and fix Drop out fuse , 11 kV ,H.T. Pole Operated, Outdoor type, vertical mounted Expulsion type, DROP OUT FUSE each pole consist of M.S. Base, Original Porcelain type Insulators & Fiber glass fuse carrier Confirming to ISS 9385/1985 Or BSS 2692/1956(without fuse element) , Current Carrying Capacity 200 Amps complete all as specified and as directed by Engr in charge.
M&L for Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 70 to 120 Sqmm complete all as specified and as directed by Engr in charge.
Supply and fix cable jointing kit for 11 KV grade cable for indoor termination, heat shrink type, joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Aluminium conductor cable of size 70 to 120 sq mm complete all as specified and as directed by Engr in charge.
Spreading, levelling, compacting of riddled earth obtained from trenches for cable cushioning on top and bottom of cable for cable protection complete all as specified and directed. (Note: Only punned thickness of riddled earth shall be measured)
M & L for laying double walled corrugated HDPE pipe inner plain 750 N with RR & NPF nominal dia 90 mm complete all as specified and directed.
M & L for laying double walled corrugated HDPE pipe inner plain 750 N with RR & NPF nominal dia 75 mm complete all as specified and directed.
M & L for laying double walled corrugated HDPE pipe inner plain 750 N with RR & NPF nominal dia 63 mm complete all as specified and directed.
Supply and fix brass double compression cable gland with bright nickel plated finish , weather proof , with sealing ring made of Neoprene/Nitrile/Natural Rubber, IP 67 , size of the gland suitable for cable size 3.5 C x 120 sqmm (37-41 mm dia) complete all as specified and directed.
Supply and fix brass double compression cable gland with bright nickel plated finish , weather proof , with sealing ring made of Neoprene/Nitrile/Natural Rubber, IP 67 , size of the gland suitable for cable size 3.5 C x 70 sqmm (30-33 mm) dia complete
Supply and fix brass double compression cable gland with bright nickel plated finish , weather proof , with sealing ring made of Neoprene/Nitrile/Natural Rubber, IP 67 , size of the gland suitable for cable size 3.5 C x 35 sqmm (23-26 mm) dia complete
Supply and fix brass double compression cable gland with bright nickel plated finish , weather proof , with sealing ring made of Neoprene/Nitrile/Natural Rubber, IP 67 , size of the gland suitable for cable size 4C x 16 sqmm (20-23 mm) dia complete
Supply , installation, testing and commissioning LT Electric control panel , cubical type, for indoor use floor mounted made out of CRCA outer sheet of 3 mm thick and inner sheet of 2 mm thick and angle iron legs of size 50mmx50mmx5mm having front and rear open hinged doors with front openable shutters for each MCCB with spreader with fully enclosed bus bar chamber, having insulated bas bar made out of aluminium strips of rating 1000 amps for 3 phase, 415 volts, 50 C/S 4 wire system, with cable entry provision, with suitable lugs gland, voltmeter , Ammeter,CTs and phase indicator complete, duly painted with two coats of stove enameled powder coated paint over as coat of red oxide primer complete and nut,bolt,washers for connection of cable, including necessary PCC work of height 45 cm from ground level and white washing to the platform all as specified and equipped with the following items :- (Main LT Panel, Loc : Sub Station). INCOMER I.ACB 4 Pole, 415 V, Manual Drawout type with microprocessor release of capacity 630 Amps- 01 Nos. II. Multifunction meter Make : L&T Cat part No: WL441010OOOO - 01 No III. LED Indicator lamp in three colour RYB - 03 Nos (L&T) OUT GOING I. MCCB 4 Pole, 415 V, Adjustable type, 350 Amps with breaking capacity 36 KA - 01 Nos. II.MCCB, 4pole, 100 Amps ,with breaking capacity 16 KA - 02 Nos. III.MCCB, 4pole, 63 Amps ,with breaking capacity 16 KA - 03 Nos.
Supply, installation , testing and commissioning of bus bar trunking sandwich type with Aluminium Conductor of rating 630 Amps IP 66 Ingress protection including following items:- (a) 630A Sandwich Type Busduct [ Type Tested ] for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply with metal clad enclosure having IP-66 Ingress Protection enclosure made of 1.6mm thick steel sheet duly powder coated in convenient sections with External Metal Canopy [ MIN 1.2 MM Sheet duly powder coated] for Outdoor complete with 4 Nos aluminium bus bars with 40KA short time current withstand capacity for 1 sec for three Phase fault including 90 deg elbow, Flanged End, Adopter Box, Cu braided Flexibles with continuous earthing with 2 Nos aluminium strip of suitable size (one on each side) including MS support structure to Install Busduct in outdoor at height around 4 mtrs . (b) Straight Run Feeder IP-66 Protection (c)90 Deg Elbow (d) Flange End (e) Phase Inversion Element (f) Adopter Box (g) Cu Braided Flexibles (h) External Canopy (j) MS Support Structure (with corrosion resistance painting ) upto 2000Kg. Note : Supply only rate for the item sl no (88) to (93) mentioned herewith shall be measured and paid seperately
Supply only 90 Deg Elbow for the busbar trunking system complete
Supply only Flange End for the busbar trunking system complete
Supply only Phase Inversion Element for the busbar trunking system complete
Supply only Adopter Box for the busbar trunking system complete
Supply only Cu Braided Flexibles for the busbar trunking system complete
Supply only External Canopy for the busbar trunking system complete
Supply only MS Support Structure for the busbar trunking system complete
Supply , installation testing and commissioning LT Electric control panel, cubical type, for out door use floor mounted made out of CRCA outer sheet of 3.15 mm thick and inner sheet of 2 mm thick and angle iron legs of size 50mmx50mmx5mm having front and rear open hinged doors with front openable shutters for each MCCB with spreader with fully enclosed bus bar chamber, having insulated bas bar made out of aluminium strips of rating 800 amps for 3 phase, 415 volts, 50 C/S 4 wire system, with cable entry provision, with suitable lugs gland, voltmeter , Ammeter,CTs and phase indicator complete, duly painted with two coats of stove enameled powder coated paint over a coat of red oxide primer complete and nut,bolt,washers for connection of cable, including necessary PCC work of height 45 cm from ground level and white washing to the platform all as specified and equipped with the following items :- (For DG Set Loc : Near AMF). INCOMER: I.MCCB, 4pole, 250 Amps , rupturing capacity 36 KA magnetic thermal release - 01 Nos. II. Multifunction meter Make : L&T Cat part No: WL441010OOOO - 01 No III. LED Indicator lamp in three colour RYB - 03 Nos (L&T) OUTGOING: I. MCCB, 4pole, 160 Amps , rupturing capacity 36 KA - 02 Nos.(AC/spare) II. MCCB, 4pole, 100 Amps , rupturing capacity 16 KA - 03 Nos.(Lift/ Pump House/spare) III.MCCB, 4pole, 63 Amps , rupturing capacity 16 KA - 02 No.( security light/ charging)
S & F Pumping sets, centrifugal, electric driven of capacity 2 HP , Suction Size (in mm) - 65 mm, Delivery Size (in mm) - 50 mm , 415 V, Head - 11 to 16 m , Discharge - 4 to 9.4 LPS , inclusive of PCC foundation complete all as specifed and directed.(02 nos 1W+1S)
Supply and fix Foot Valve flanged type conforming to IS 4038, 65 mm dia with necessary bolts, nuts, washer etc of suitable size complete all as specified and as directed
Supply, installation, testing and commissioning LT Electric control panel , cubical type, for indoor use floor mounted made out of CRCA outer sheet of 3 mm thick and inner sheet of 2 mm thick and angle iron legs of size 50mmx50mmx5mm having front and rear open hinged doors with front openable shutters for each MCCB with spreader with fully enclosed bus bar chamber, having insulated bas bar madeout of aluminium strips of rating 200 amps for 3 phase, 415 volts, 50 C/S 4 wire system, with cable entry provision, with suitable lugs gland, voltmeter , Ammeter,CTs and phase indicator complete, duly painted with two coats of stove enameled powder coated paint over a coat of red oxide primer complete and nut,bolt,washers for connection of cable, including necessary PCC work of height 45 cm from ground level and white washing to the platform all as specified and equipped with the following items :- ( Loc : Pump House). INCOMER I.MCCB, 4pole, 100 Amps , rupturing capacity 16 KA - 01 Nos. II. Multifunction meter Make : L&T Cat part No: WL441010OOOO - 01 No III. LED Indicator lamp in three colour RYB - 03 Nos (L&T) OUT GOING I.MCCB, 4 pole, 16-63 Amps , rupturing capacity 16 KA - 04 Nos II. DOL Starter 3 phase upto 10 HP Pump - 02 No
Material and labour for brick masonry valve chamber of size 900x900x900 mm (internal size) by providing PCC 1:2:4 type B-2 foundation 100mm thick and brick work in CM 1:4 plastering 10mm thick in CM 1:4 internal surfaces and external surfaces completely and at external surfaces upto 150mm below GL, 75mm thick PCC 1:2:4 type B-2 as in coping for valve chamber cover made up of 40x40x5mm thick angle iron frame and 3 mm thick MS sheet cover complete with locking arrangements and handle including painting all steel surfaces with two coat of synthetic enamel paint over a coat of red oxide primer and removing debris away from the premises incl necessary earth work complete all as specified and as directed.
M&L for Shifting of existing Centrifugal pump 5HP to New pump house and installation of same all as specified and directed by Engineer-in-charge.
Supply , installation,testing and commisioning of silent Diesel Engine driven generating set of capacity 160 kVA , CPCB IV+ Emission Compliant , 415 volts at 1500 RPM ,0.8 lagging power factor at 415 V suitable for 50 Hz, 3 phase 4 wire, engine as per IS:10001/ 10002 and Alternator as per IS: 13364 complete with foundation (as per OEM design), standard control panel with necessary meter and sound proof canopy and for 0.85 Load Factor and consisting of the followings: Diesel Engine: Diesel engine 4 stroke water cooled, electric start, of suitable BHP at 1500 RPM suitable for above output of alternator at 40 Degree C, 50% RH & at 1000 Meter MSL and conforming to BS 5514, BS 649, IS 10000, capable of taking 10% over loading for one hour after 12 hours of continuous operation. The engine will be fitted complete with all the required accessories. Engine mounted Instrument Panel fitted with and having digital display for following: (i) Start-stop switch with key, ii) Water temperature indication (iii) Lubrication oil pressure indication (iv) Lubrication oil temperature indication (v) Battery charging indication (vi) RPM indication
Item No. 100 contd.... (vii) Over speed indication (viii) Low lub. Oil trip indication (ix) Engine Hours indication Alternator : Synchronous alternator rated at 160 KVA, 415 volts at 1500 RPM, 3 phase 50 Hz, AC supply with 0.8 lagging power factor at 40 Degree C, 50% RH & at 1000 Meter MSL. The alternator shall be having SPDP enclosure, brushless, continuous duty, self-excited and self-regulated through AVR conforming to IS: 4722/BS 2613 suitable for tropical conditions and with class- F/H insulation. Base Frame & Foundation: Both the engine and alternator shall be mounted on suitable base frame made of MS channel with necessary reinforcement which shall be installed on suitable cement concrete foundation and vibration isolation arrangement as per recommendations of manufacturer. Fuel Tank: Daily service fuel tank of 400 liters capacity fabricated out of 3 mm thick M.S. sheet complete with all standard accessories and fuel piping between fuel tank and diesel engine with MS class ‘C’ pipes of suitable dia. Complete with valves, level indicatiors & accessories all as specified and directed.
Item No. 100 contd.... Exhaust System: 1) Dry exhaust mainfold with hospital exhaust silencer and catalytic convertor. 2) Exhaust gas piping of suitable dia. welded black MS, B Class pipe conforming to IS:3589 cut to required lengths and installed with necessary bends, supports and clamps, anti-vibration mountings, insulation of exhaust system with mineral wool/Rockwool, 50 mm thick wiremesh & aluminium cladding etc., as required & as directed by Engineer in Charge . Starting System: 12V/24V DC starting system comprising of starter motors: voltage regulator and arrangement for initial exitation complete with suitable nos. of batteries as required as per specifications. Accoustic and weather proof enclosure with arrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air in to the atmosphere all as specified and directed.
Design, supply, install, testing & commissioning goods lift ,with capacity of 2000 Kg ,speed 0.5 metre/sec with single speed motor, 415 volts, 3 phase AC 50 Hz supply, conforming to IS-14665 and as amended, suitable to serve G+02 upper floors with AC Variable Voltage & Variable Frequency Drive (VVVF drive) complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendant, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, automatic rescue device (ARD) system, 3D infra red sensor in full height of door & built in announcing system without hand set (03 Nos, one each in car, Machine room & near Ground floor landing door)and all civil works required with erection of lift incl auto fan, LED lights, emergency lights all as specified .The lift shall be provided with and including the following:- (a)alarm speaker for alarm system to be fixed),stop button in car with rechargeable arrangement for battery, (b) four sleek circular LED lights fitting in false ceiling, (c) overload warning indicator both audio and visual type with tripping system having relay etc. (d) set of three nos limit switches at the bottom and top most position of lift.(e) display indicating panel, power control cables (f) testing of govt approved lift inspector (h) Marking on lift's pit and lift room (i) Mirror of 6mm thickness of suitable size on one wall inside the car
(k) Battery operated emergency light (LED ceiling fitting), alarm (speaker for emergency alarm system to be fixed on all the floors) and stop button in car with rechargeable arrangement for battery (l) Aluminium chequered plate (3mm thick) as flooring (m) Car size shall be conforming with IS-3534-1976 and body to be stainless steel of 16 gauge mirror finish with stainless steel hand rail (n) Front door, operations with a minimum time of 10 seconds and upto a maximum timeof 30 seconds. (o) Hand rail (o) Specification plate (p) Wire rope/belt as per specification of adequate size as per relevant IS and as per manufacturer specification (q) Suitable earthing pit earthing of lift as per IS and as required technically (r) One sleek circular PVC heavy duty fan in false ceiling.(s) Fire man switch (t) Automatic rescue device during power failure with capacity of battery designed for 45 minutes including manual operation provision (u) Other standard fixtures and fittings like guide rails, sheaves, counter weight with guard, buffers, gears, brakes, control panel, motor, locks, governor,car operational panel, power control and trailing cables complete. Note :- The rate quoted shall be Including the rate for comperhensive maintenance period for two years after completion of the work.
Note (i) Contractor shall provide comprehensive maintenance services including routine (Weekly, monthly, Bimonthly , Every three / six months, Annually), preventive, and breakdown corrective maintenance for the lifts as per OEM guidelines and statutory compliance inclusive all materials, spares, labour, testing instrument, Transportation of Materials & Parts, etc. as required and rate quoted by the tenderer includes the above.Contractor shall ensure trouble free operation of lift, which are required to be on continuous operation round the clock.Services shall cover all lift components (including electrical, mechanical, and control systems) supplied and installed by the original equipment manufacturer (OEM) or their authorized representatives. Comprehensive maintenance check list is attached in Appx -A. (ii) All parts and components fitted by contractor will be original parts or components from OEM. If original parts or components are not available, the parts or components fitted will be of equal quality and functionality of reputed brands/makes with ISI mark only, shall be used after the approval of Engr - in- Charge. Contractor will keep sufficient Nos. of spares required for replacement during day-to-day maintenance and Breakdown/ Corrective Maintenance to avoid delay. (iii) Contractor must provide sufficient manpower including qualified technicians, supervisor(s) and helpers for carrying out the routine (Weekly, Monthly, Bimonthly , Every three / six months, Annually maintainance ), preventive, and breakdown corrective maintenance for the lifts as per OEM guidelines , all of them shall carry identification badges during duty. (iv) Only OEM-trained or certified technicians with proper safety gear shall perform maintenance services.All maintenance, repair, and replacement activities must adhere to highest standards of workmanship and cleanliness.
Supply , installation, testing and commissioning of indoor panel CPRI Approved ,IP 42 made out of CRCA sheet 2 mm thick vermin proof factory made with 40 x 40 x6 mm MS angle/channel duly painted with two coats of synthetic enamel powder coated paint over a coat of metal primer with bus bar chamber comprising of high conductivity aluminium bus bar of capacity 200 Amps three phase and half the capacity for neutral including internal wiring with 6 sqmm copper conductor (FRLS) including PCC foundatoin suitable to accommodate the following as specified and as directed.: INCOMING: (a) MCCB 415 V,100 A, 4 pole thermal release with over load , short circuit and earth fault protection with earth module breaking capacity 16 KA- 01 Nos. (b)Digital Panel Meter Multifunctional type for Amps, Volts, KWH, Power Factor and other parameters flush mounting with LED indication lamp complete and all as per standard pratice ---1 Job OUT GOING (a) MCCB 63 A, 415V , 4 pole thermal release ,over load short circuit protection, breaking capacity 16 KA electronic release- 03 Nos (b) MCCB 40 A, 415V , 4 pole with Electronic Earth leakage module ,over load short circuit protection, breaking capacity 16 KA electronic release - 02No Note :-(i) All MCCBs / instruments / MCBs /Bus Bar shall be housed in a separate housing with on- off latches in the housing and Digital Panel Meter Multifunctional type for Amps, Volts, KWH, Power Factor and other parameters flush mounting with LED indication lamp for each outgoing complete and all as per standard practice.
Boring for bored cast-in-situ piles 600mm dia in soft soil and getting out and disposal of spoil outside MD land using hydraulic system of boring method complete all as specified and directed.
M & L for carrying out initial load test on 600mm dia pile as per IS-2911 part-IV complete all as specified and as directed.
M & L for carrying out routine load test on 600mm dia pile as per IS-2911 part-IV complete all as specified and as directed.
M & L for carrying out low strain integrity test on cast in situ piles 600mm dia including analysing the result as per ASTM D 5882 complete all as specified and as directed.
M & L for carrying out lateral load test on cast in situ piles 600mm dia pile as per IS complete all as specified and as directed.
M & L for carrying out pull out test on cast in situ piles 600mm dia pile as per IS complete all as specified and as directed.
Sch A Part-XV PHASE-II (FIRST YEAR COMPREHENSIVE MAINTENANCE OF GOODS LIFT AS PROVIDED UNDER THIS CONTRACT AS PER SERIAL ITEM No. 102 AFTER EXPIRY OF DEFECT LIABILTY PERIOD.)
Comprehensive maintenance of Electrically Operated Goods lifts (01 No) to serve G+2 upper floors including ARD all as mentioned vide SI No. 102 of BOQ during 1st year after expiry of defects liability period complete all as specified and directed
Sch A Part-XVI PHASE-III (SECOND YEAR COMPREHENSIVE MAINTENANCE OF GOODS LIFT AS PROVIDED UNDER THIS CONTRACT AS PER SERIAL ITEM No. 102 AFTER EXPIRY OF DEFECT LIABILTY PERIOD.)
Comprehensive maintenance of Electrically Operated Goods lifts (01 No) to serve G+2 upper floors including ARD all as mentioned vide SI No. 102 of BOQ during 2nd year after expiry of defects liability period and After completion of first year Comprehensive Maintenance.complete all as specified and directed
Sch A Part-XVII PHASE-IV (THIRD YEAR COMPREHENSIVE MAINTENANCE OF GOODS LIFT AS PROVIDED UNDER THIS CONTRACT AS PER SERIAL ITEM No. 102 AFTER EXPIRY OF DEFECT LIABILTY PERIOD.)
Comprehensive maintenance of Electrically Operated Goods lifts (01 No) to serve G+2 upper floors including ARD all as mentioned vide SI No. 102 of BOQ during 3rd year after expiry of defects liability period and After completion of second year Comprehensive Maintenance all as specified and directed
Note for SL No: 111 to 113:- (i) Contractor shall provide comprehensive maintenance services including routine (Weekly, monthly, Bimonthly , Every three / six months, Annually), preventive, and breakdown corrective maintenance for the lifts as per OEM guidelines and statutory compliance inclusive all materials, spares, labour, testing instrument, Transportation of Materials & Parts, etc. as required and rate quoted by the tenderer includes the above.Contractor shall ensure trouble free operation of lift, which are required to be on continuous operation round the clock.Services shall cover all lift components (including electrical, mechanical, and control systems) supplied and installed by the original equipment manufacturer (OEM) or their authorized representatives. Comprehensive maintenance check list is attached in Appx -A. (ii) All parts and components fitted by contractor will be original parts or components from OEM. If original parts or components are not available, the parts or components fitted will be of equal quality and functionality of reputed brands/makes with ISI mark only, shall be used after the approval of Engr - in- Charge. Contractor will keep sufficient Nos. of spares required for replacement during day-to-day maintenance and Breakdown/ Corrective Maintenance to avoid delay. (iii) Contractor must provide sufficient manpower including qualified technicians, supervisor(s) and helpers for carrying out the routine (Weekly, Monthly, Bimonthly , Every three / six months, Annually maintainance ), preventive, and breakdown corrective maintenance for the lifts as per OEM guidelines , all of them shall carry identification badges during duty. (iv) Only OEM-trained or certified technicians with proper safety gear shall perform maintenance services.All maintenance, repair, and replacement activities must adhere to highest standards of workmanship and cleanliness.
Schedule of credit amount brought back from Ser Page No. 86 - Rs. 1,00,196.05 will be deducted from the above quoted amount to derive the contract sum. SIGNATURE OF CONTRACTOR
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.18 MB
82691GENERALPAGES.pdf
Tender Documents • 0.42 MB
82691PS.pdf
Additional Documents • 1.18 MB
82691Schedules.pdf
Additional Documents • 0.15 MB
Drawing1.rar
Additional Documents • 21.75 MB
Drawing2.rar
Additional Documents • 21.61 MB
BOQ_835934.xls
BOQ • 0.49 MB
Download all tender documents and submit your bid