RequiredExperience with Government
RequiredOEM Authorization Certificate Bid to RA enabled No Door Frame Metal Detector Dfmd Security Metal Detector ( 259 pieces ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Bid Requirement (Allowed Values) TYPE/CAPACITY Type of usage Outdoor Outdoor Detection Zones Single Zone Single Zone Function Detects Ferrous
RequiredNon- Ferrous and alloy metals concealed in the body of a person when passsed through the arch way * 1/8 Number of Horizontal Detection Zones covering full Height Single Zone Single Zone Capacity/throughput rate (person/min) 25 or more * False Alarm rate (%) 3 * DIMENSIONS/WEIGHT Passage Height 2050 * Passage Breadth 720 * Passage Width 570 * Weight of the equipment Not more than 80 Kg * DOOR FRAME CONSTRUCTION Construction of Door Frame (Walk-through Arch) Light weight
Requiredrigid
Requiredlaminated side panels and cross piece with ABS plastic boots for panel protection * Material of Walk- through Arch POLYCARBONATE POLYCARBONATE Provided with base wheels for easy mobility Yes Yes
RequiredNo Provided with a floor panel to attach both side panels to give stability & rigidity to the structure Yes Yes Ramp over the floor panel - Covered with synthetic carpet for long life Yes Yes Water proof Yes Yes Weather proof Yes Yes DETECTION Metals detectable Ferrous
RequiredNon-Ferrous
RequiredFerrite & Alloys * Uniform Detection from top to bottom Yes * Capable of Metal Detection in all orientations Yes * Detect multiple objects of various size
Requiredweight and shape in all the zones simultaneously from head to toe Yes * Capable of Metal Detection in walking speed of interception Yes * 2/8 Performance independent of the speed of person passing through Yes * ALARM/INDICATION DISPLAY Audio-Visual indication on detection at side panels and control panel Yes * Audible Alarm on detection with adjustable volume Yes * Bar Display to indicate Metal location w r t Height on person No Yes
RequiredNo Audio-Visual Low Battery indication Yes * Back-lit Display LCD * SENSITIVITY Operational Frequencies User selectable * Number of User Selectable frequencies 8 * Adjustable Sensitivity Yes * Number of Sensitivity Levels/Steps 15 * Uniform Sensitivity in all zones Yes * Calibration Both manual and Auto Calibration * SECURITY Provision to secure access to the control unit by a pass word protected alpha numeric keypad Yes * Re-setting after alarm condition Re-set itself (auto) within 3 Seconds * Walk/Stop indicator for traffic control Yes * Control Panel Easy accessible control panel
Requiredwith modular design and standard plugs and connectors. Adjustable controls should only be activated on insertion of a removable key and or by password. * User friendly self- testing diagnostics to Yes * 3/8 identify faulty condition INTERFERENCE SUPPRESSION REJECTION Automatic synchronization for DFMDs Do not interfere with adjacent installed DFMDs located close to each other upto a distance of 1 * Static Metal Compensation Not affected by heavily reinforced floors/roof tops/walls Yes * High discrimination between small masses and personal metallic objects Yes * Not affected by external RF transmission and EMI (Electro Magnetic Interference) Yes * Not affected by by interference
Requiredwhich is mains-borne or radiated by external source Yes * Not affected by the operation of radio
RequiredMobile phones
Requiredwalkie- talkie sets
RequiredX-ray monitors etc within a distance of one meter Yes * Not affected by moving metallic items such as trolleys
Requiredopening closing of metallic gate etc
Requiredone meter away from the archway Yes * HEALTH & SAFETY Harmless to wearers of pacemakers
Requireddefibrillators or other vital support systems
Requiredpregnant women and magnetic storage media Yes * Not affected by infrared
Requiredultraviolet
Requiredelectromagnetic or RF radiation Yes * Conform to international security Yes * 4/8 standards of Safety Radiation Harmless to magnetic media
Requiredelectronic devices
RequiredFilm safe and Data safe Yes * ENVIRONMENTAL Operating Temperature Range (Degree C) Minus 10 to Plus 50 Degree C Minus 20 to Plus 55 Degree C
RequiredMinus 10 to Plus 50 Degree C
RequiredMinus 5 to Plus 55 Degree C Operating Humidity - Non condensing (RH) (%) 95 * POWER SUPPLY BATTERY Source of Power Operated by AC mains supply and alternatively by rechargeable battery * Power Supply 220 V +/-10% VAC * Battery Re-chargeable
Requiredmaintenance free
Requiredinternal battery with charger Re-chargeable
Requiredmaintenance free
Requiredinternal battery with charger Battery Back-up in full function (hours) 16 16.0 ACCESSORIES One Standard Test Piecec for each machine for testing during commissioning maintenance Inclusive in the scope of supply * Training tools- Charts
Requiredslides
Requiredtraining brochure
Requiredtraining work model
Requiredblowup diagram
Requiredvideo films on demonstration and use etc Inclusive in the scope of supply * Technical manual giving full description of the item
Requireduser's handbook and literature Yes * Practical training 1 Day 1 Day Availability of Spares for a period of 7 years after the warranty period Yes Yes Ruggedized polypropylene shock proof container No Yes
RequiredNo 5/8 compliant to IP 65 or better for safe transportation of the equipment WARRANTY Warranty (Years) 3 3.0 CERTIFICATION Availability of Test Report from NABL ILAC accredited or Central Government Lab to prove conformity of products to the specification Yes Yes Test Report Number & Date - * Name & address of the Lab - * * Bold specifications are the golden parameters. * Bidders may note that In respect of non-golden Parameters
Requiredthe specifications 'Values' chosen by Buyer will generally be preferred over 'Bid requirement ( allowed Values) by the Buyer.