Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.6 LAccepted-AOC | ₹29.6 L | L1 | Accepted-AOC BEING LOWEST |
| 2 | L2₹30.0 LRejected-Finance | ₹30.0 L | L2 | Rejected-Finance NOT BEING LOWEST |
| 3 | L3₹31.7 LRejected-Finance | ₹31.7 L | L3 | Rejected-Finance NOT BEING LOWEST |
| 4 | L4₹32.3 LRejected-Finance | ₹32.3 L | L4 | Rejected-Finance NOT BEING LOWEST |
| 5 | L5₹32.3 LRejected-Finance | ₹32.3 L | L5 | Rejected-Finance NOT BEING LOWEST |
| Sl No | Description | Qty | Unit | Sagar Builders L8 | S G Enterprises L3 | M/S P D TUPE L1 | agarwal and company L6 | Mehta and Co. L4 | Vikrant Deepak Mate L2 | M/S OMSAI ENTERPRISES L7 | M/S Divyani Aadhar Patil L5 | M/S CDRATHOD INFRATECH PRIVATE LIMITED L9 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | B/R PORTION
Excavating in post holes in any type of soil (or similar hoels) each n exc 0.5 cum getting out, returining, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance n exc 50 mtr complete all as specified and as directed. | 18 | EACH | 300 ₹5,400 | 150 ₹2,700 | 100 ₹1,800 | 180 ₹3,240 | 200 ₹3,600 | 200 ₹3,600 | 200 ₹3,600 | 500 ₹9,000 | 50 ₹900 |
| 2.00 | M&L plain cement concrete in foundation type C 2, 1:3:6 (40 mm grade stone aggregate) as in filling and mass concrete complete all as specified and as directed. | 2.19 | CUM | 4,400 ₹9,622.80 | 3,500 ₹7,654.50 | 3,500 ₹7,654.50 | 5,004 ₹10,943.75 | 3,000 ₹6,561 | 3,200 ₹6,998.40 | 5,000 ₹10,935 | 6,000 ₹13,122 | 4,000 ₹8,748 |
| 3.00 | S&F structural steel work in plates, girder, channels square cut or notched (ordinary and colour sunk) forming holes, without any attachment conf to Fe 410-W (Gde E-250) quality 'A' complete all as specified and as directed. | 250 | KG | 110 ₹27,500 | 165 ₹41,250 | 100 ₹25,000 | 117 ₹29,250 | 120 ₹30,000 | 110 ₹27,500 | 125 ₹31,250 | 150 ₹37,500 | 100 ₹25,000 |
| 4.00 | S&F sturctural steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes confrming to IS 1161-1979 grade St-240 Complete all as specified and as directed. | 5,500 | KG | 135 ₹7.4 L | 125 ₹6.9 L | 95 ₹5.2 L | 108 ₹5.9 L | 110 ₹6.0 L | 110 ₹6.0 L | 125 ₹6.9 L | 160 ₹8.8 L | 110 ₹6.0 L |
| 5.00 | M&L applying two coats of synthetic enamel paint over a coat of red oxide or zinc chromate primer including preparation of new steel or iron surfaces exc 10 cm width or girth, complete all as specified and directed. | 130 | SQM | 65 ₹8,450 | 85 ₹11,050 | 60 ₹7,800 | 45 ₹5,850 | 100 ₹13,000 | 65 ₹8,450 | 125 ₹16,250 | 125 ₹16,250 | 60 ₹7,800 |
| 6.00 | S&F Pre-painted galvalume aluminium zinc coated GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 mpa as in roof covering /cladding to wall fixed with self tapping screws complete all as specified and directed. | 650 | SQM | 950 ₹6.2 L | 750 ₹4.9 L | 650 ₹4.2 L | 720 ₹4.7 L | 650 ₹4.2 L | 750 ₹4.9 L | 750 ₹4.9 L | 450 ₹2.9 L | 900 ₹5.8 L |
| 7.00 | M&L for false ceiling with powder coated exposed G.I. grid suspension system (E-Grid T-2430 or equivalent load carrying capacity with mid span deflection not exceeding 1/360 span with hanger spacing of 1200 mm c/c) consisting of Main Runner 3600 mm long, Cross Tee 1200mm/600mm long and Wall Angle. The Wall Angle shall be fixed on PVC Dash Fasteners on the perimeter of the wall by steel screws with distance 300 mm c/c. The Main Runners to be placed @ 1200mm, The Cross Tee 1200mm will be inserted in the pre-cut slots of Main Runner at a regular interval of 600 mm to form a modular grid of 1200mm x 600mm. Additional Cross Tees of 600 mm shall be placed perpendicular to the Cross Tee 1200 mm long to finally form a grid of 600mm x 600mm. Grid of module size 600mm x 600mm shall be supported by 6 mm dia G.I. wire from purlins/soffit. 4mm thick High Pressure Steam Cured Non Asbestos Fibre Cement Designer Ceiling Board (Density>1200 Kg/m3, Modulus of Rupture(M.O.R)-15.85 MPa, Thermal Conductivity(K)-0.0872 W/mK) of size 595mm x 595mm, confirming IS 14862 & Type B Category III of ISO 8336:1993, (Reaction to fire-A2-s1-d0) tested as per EN13501 Part-I & BS-476 Part 4,5,6&7, should be placed in the Grid module to form a False Ceiling complete all as specified and as directed. | 300 | SQM | 1,580 ₹4.7 L | 1,050 ₹3.1 L | 1,150 ₹3.5 L | 900 ₹2.7 L | 1,500 ₹4.5 L | 1,100 ₹3.3 L | 850 ₹2.5 L | 950 ₹2.9 L | 1,800 ₹5.4 L |
| 8.00 | M & L for granite 18-20 mm thick black/red colour (of any type) work (table rubbed, and polished) in staircase steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite incl Screed bed or bedding layer of mortar 15 mm thick in cm (1:6) for laying floor finishes complete all as specified and as directed. | 20 | SQM | 4,200 ₹84,000 | 3,200 ₹64,000 | 2,650 ₹53,000 | 3,600 ₹72,000 | 3,000 ₹60,000 | 3,600 ₹72,000 | 3,000 ₹60,000 | 3,800 ₹76,000 | 2,500 ₹50,000 |
| 9.00 | Racking out joints/pointing to random rubble or polygonal rubble uncoursed or brought up to courses buit in cement or cement lime mortar complete all as specified and as directed. | 21 | TEN SQM | 350 ₹7,350 | 300 ₹6,300 | 1,000 ₹21,000 | 900 ₹18,900 | 500 ₹10,500 | 300 ₹6,300 | 200 ₹4,200 | 300 ₹6,300 | 500 ₹10,500 |
| 10.00 | M&L for keyed pointing to random or polygonal rubble uncoursed or brought upto courses in cement mortar 1:4 complete all as specified and as directed. | 21 | TEN SQM | 1,350 ₹28,350 | 1,200 ₹25,200 | 1,000 ₹21,000 | 1,800 ₹37,800 | 500 ₹10,500 | 900 ₹18,900 | 1,500 ₹31,500 | 800 ₹16,800 | 2,000 ₹42,000 |
Updated dates
Tender Value
₹42.5 L
EMD Value
₹81,500
Closing Date
10 Dec 2025, 6:00 pmClosed
GE I R AND D GIRINAGAR PUNE 25
GE I R AND D GIRINAGAR PUNE 25
PROVN OF THREE COVERED SHED FOR SEDIMENTATION TANKS AND CERTAIN MISC BR AND EM WORKS AT WATER TREATMENT PLANT AT MILIT GIRINAGAR PUNE 25
2025_MES_738843_1
GE I R AND D GNR TOKEN 72 OF 2025-2026 (8935)
Open Tender
Civil Works
180 days
GE I R AND D GIRINAGAR PUNE 25
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE I R AND D GIRINAGAR PUNE 25
₹81,500
Yes
4 Feb 2026
7 Nov 2025
12 Dec 2025
7 Nov 2025
10 Dec 2025
26 Nov 2025
7 Nov 2025 - 15 Nov 2025
Amount
B/R PORTION Excavating in post holes in any type of soil (or similar hoels) each n exc 0.5 cum getting out, returining, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance n exc 50 mtr complete all as specified and as directed.
M&L plain cement concrete in foundation type C 2, 1:3:6 (40 mm grade stone aggregate) as in filling and mass concrete complete all as specified and as directed.
S&F structural steel work in plates, girder, channels square cut or notched (ordinary and colour sunk) forming holes, without any attachment conf to Fe 410-W (Gde E-250) quality 'A' complete all as specified and as directed.
S&F sturctural steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes confrming to IS 1161-1979 grade St-240 Complete all as specified and as directed.
M&L applying two coats of synthetic enamel paint over a coat of red oxide or zinc chromate primer including preparation of new steel or iron surfaces exc 10 cm width or girth, complete all as specified and directed.
S&F Pre-painted galvalume aluminium zinc coated GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 mpa as in roof covering /cladding to wall fixed with self tapping screws complete all as specified and directed.
M&L for false ceiling with powder coated exposed G.I. grid suspension system (E-Grid T-2430 or equivalent load carrying capacity with mid span deflection not exceeding 1/360 span with hanger spacing of 1200 mm c/c) consisting of Main Runner 3600 mm long, Cross Tee 1200mm/600mm long and Wall Angle. The Wall Angle shall be fixed on PVC Dash Fasteners on the perimeter of the wall by steel screws with distance 300 mm c/c. The Main Runners to be placed @ 1200mm, The Cross Tee 1200mm will be inserted in the pre-cut slots of Main Runner at a regular interval of 600 mm to form a modular grid of 1200mm x 600mm. Additional Cross Tees of 600 mm shall be placed perpendicular to the Cross Tee 1200 mm long to finally form a grid of 600mm x 600mm. Grid of module size 600mm x 600mm shall be supported by 6 mm dia G.I. wire from purlins/soffit. 4mm thick High Pressure Steam Cured Non Asbestos Fibre Cement Designer Ceiling Board (Density>1200 Kg/m3, Modulus of Rupture(M.O.R)-15.85 MPa, Thermal Conductivity(K)-0.0872 W/mK) of size 595mm x 595mm, confirming IS 14862 & Type B Category III of ISO 8336:1993, (Reaction to fire-A2-s1-d0) tested as per EN13501 Part-I & BS-476 Part 4,5,6&7, should be placed in the Grid module to form a False Ceiling complete all as specified and as directed.
M & L for granite 18-20 mm thick black/red colour (of any type) work (table rubbed, and polished) in staircase steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite incl Screed bed or bedding layer of mortar 15 mm thick in cm (1:6) for laying floor finishes complete all as specified and as directed.
Racking out joints/pointing to random rubble or polygonal rubble uncoursed or brought up to courses buit in cement or cement lime mortar complete all as specified and as directed.
M&L for keyed pointing to random or polygonal rubble uncoursed or brought upto courses in cement mortar 1:4 complete all as specified and as directed.
Taking down cement plaster, any description on brick, concrete or stone walls or ceiling including racking out joints, hacking for key, scrubbing down with water etc and removal of rubbish off outside MD land complete all as specified and as directed.
M & L rendering 15mm thick on stone masonry surface or concrete surface finished even and smooth without using extra cement in cement mortar 1:4 complete all as specified and directed.
S&F, glazed ceramic tiles coloured/highlighter 450mm x 350mmx 7 mm thick in wall/dado etc, set & jointed in neat cement slurry & pointed in white or coloured cement to match rendering over 15 mm thick in CM 1:6 on stone masonry surfaces or surfaces other than fair face of brick work/ concrete surfaces complete all as specified and directed.
M&L for mirror polished Kota stone slab 20-25mm thick in Tread of steps in single pieces incl two numbers of grooves of size 3mmx3mm and rounding to edge, laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab incl rubbing and mirror polishing with and incl 10mm thick screed in CM (1:4) complete all as specified and as directed.
S & F Machine cut cuddappa stone slab one side polished 20 to 25mm thick, set and jointed in neat cement slurry and pointed in coloured cement to match, laid over and including 20mm screed bed in cement mortar (1:6) complete all as specified and as directed.
Demolition of cement concrete (unreinforced) in ground floors and pavings n. exc. 15 cm thickness (below or above ground level) and removing from site, complete all as specified and directed.
M&L for Hardcore of gauge n exc 63mm, deposited, spread and levelled in layers in not exc 15cm thick water and rammed to a true surface complete all as specified and directed.
M&L plain cement concrete 1:4:8 type D-2 (using 40mm graded aggregate) as in subbase 75mm thick complete all as specified and directed.
M&L for Providing and laying 60mm thick factory made chamfered edge cement concrete coloured, glossy finish paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and as directed.
S&F for glossy finished chequered cement concrete tiles 30cmx30cmx30mm /20 cm x 20cm x 25 mm (as approved) thick set jointed with grey cement and pigment and pointed in neat cement slurry with and including 15 mm thick screed bed of CM(1:6) in floors complete all as specified and as directed.
M&L for plain cement concrete Type B1 (1:2:4) in kerb or mud stop rounded or champhered on edge incld necessary formwork complete all as specified and directed.
E/M PORTION Supply, laying and testing cable LT XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of following size :- (a) 25sqmm X 4 core
(b) 10 sqmm 4 core
Supply and installation of LED Street Light fitting pressure die cast aluminium housing, heat resistant glass, IP 65 ptotection, better optics for uniform distribution of 70 Watts capacity suitable for mounting on 6 meter single arms swan neck type pole with including testing on complete all as specified and as directed.
S & F in Thermoplastic cable junction box of size 205 mm x 255 mm x 112 mm, IP 69, halogen free and weather proof with locking arrangement and necessary mounting arrangement on pole with MS clamp, nut, bolt, washer, for out door installation complete with connector terminal for connecting cable, knockouts for cable entry up to the size of 25 Sqmm x 4 core, by providing suitable size cable lugs complete all as specified and as directed.
S&F in repair street light bracket in replacement of length 1.20 meter made of GI pipe medium grade suitable size/ bore bent to shape to fixed on LT poles/street light including MS clamps nuts bolts etc complete all as specified and as directed.
Supply and fixing LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP 66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and as directed.
M & L for submain wiring alongwith earth wire with the following sizes of FRLSH PVC insulated copper conductor single core cable , multistranded Cutting chases, pinning in. making good to facings Concealed and including suitable size of Concealed conduit with its all accessories all as specified and directed by Engr-in -charge for the following: (a) 2x6 sq mm and 1x6 sq mm as earth wire
(b) 2x2.5sqmm and 1x2.5 sqmm as earth wire
(c) 2x1.5 sqmm and 1x1.5sqmm as earth wire
S & Fix sheet metal enclosure distribution board SPN, 4 ways 240 volts, with suitable capacity amps rated bus bar, with IP 43 protection and double door, suitable for mounting MCBs all as specified and as directed including taking down old MCB DB complete all as specified and as directed.
S & Fix of MCB single pole and neutral, 240 volts, 6 to 40 Ampere, rupturing capacity 10 KA, ‘C’ series complete all as specified and directed.
S & Fix of MCB single pole, 240 volts, 6 to 40 Ampere, rupturing capacity 10 KA, ‘C’ series complete all as specified and directed.
Supply and fixing Mini LED flood light 35/36 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and as directed.
Earthing complete with galvanised steel earth plate electrode 60cm × 60cm × 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion complete all as specified and as directed. Note : On completion of the work/Job, the contractor is to perform earth resistance test to each earthing job in the presence of the Engr-in-Charge of his rep and submit Test Certificate duly signed and certified. If the test result are not satisfactory or not within the permissible limit of relevant standards/IS, then the job is to be redone without any extra cost to the Dept till the result are satisfactory.
All as per item hereinabove but using 32 x 6 mm galvanized MS strip and MS galvanized plate of size 600 x 600 x 6 mm as earth electrode complete all as specified and as directed.
Supplying and laying of following size DWC pipe ISI marked along with all accessories etc confirming to IS 14930, part II complete with fitting and cutting, jointing etc. in trench/open, for LT UG cable protection complete all as specified & directed by Engr-in-charge of size 40 mm bore complete all as specified and as directed.
Supply and fixing GI tubing (ISI Marked), light grade for cable protection with all necessary fittings as required, laid in trenches, under road/floors or on electric poles complete all as specified and directed of size 25 mm bore.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m wide and not exceeding 1.5 m depth and getting out soft / loose soil for laying cables / pipes / erection of poles etc complete all as specified and directed
Removing excavated material (soil) not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed.
Returning filling in soil including spreading levelling watering well ramming in layers not exceeding 25 cm each complete all as specified and as directed.
M&L for road cutting upto 45 cms width and depth 60 to 75 cm for laying GI pipe light grade/ hume pipe for cable protection including returning filling in and making good the disturbed portion to match with the existing roads by cement/ bitumen complete all as specified and as directed. Note : If any existing services are damaged during execution of work, it shall be the responsibility of the contractor to rectify them.
Vikrant Deepak Mate (BID ID -3493813)
S G Enterprises (BID ID -3488258)
Mehta and Co. (BID ID -3488592)
M/S Divyani Aadhar Patil (BID ID -3493683)
agarwal and company (BID ID -3488335)
M/S OMSAI ENTERPRISES (BID ID -3494545)
Sagar Builders (BID ID -3487573)
M/S CDRATHOD INFRATECH PRIVATE LIMITED (BID ID -3488312)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.33 MB
TENDER.pdf
Tender Documents • 1.41 MB
BOQ_827300.xls
BOQ • 0.43 MB
Download all tender documents and submit your bid