Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.2 LAccepted-AOC | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹31.0 L+₹6.5 L (26.4%)Rejected-Finance NO 12 5TH B CROSS SHARADAMBA NAGAR M E S ROAD BANGALORE 560013 | BANGALORE | BANGALORE | KARNATAKA | 560013 | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹38.7 L+₹14.2 L (57.8%)Rejected-Finance | L3 | Rejected-Finance Not Being L1 |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
11 Feb 2023, 6:00 pmClosed
GE CENTRAL BANGALORE
Agram Post Bangalore -560007
MAINT REPAIR REPLACEMENT OF STREET LIGHT TIMER SWITCH CONNECTED CABLES BLOWER MOTOR PANEL MCCBS CABLE AND CONNECTED REPAIR MAINT OF DG SETS UNDER GE CENTRAL BANGALORE
2023_MES_574309_1
8259E
Open Tender
Electrical and Maintenance Works
Item Rate
300 days
GE CENTRAL BANGALORE
Please refer tender documents
7 documents required · 7 mandatory
₹500
GE CENTRAL BANGALORE
₹60,000
Yes
17 Apr 2023
11 Jan 2023
13 Feb 2023
11 Jan 2023
11 Feb 2023
23 Jan 2023
11 Jan 2023 - 21 Jan 2023
Amount
M&L for carrying out regular checking and maintanance of 100 KVA Capacity diesel generating set at 531 Pump house including connected alternator and control panels, and carrying out routine 'A' check of the set complete for smooth functioning all as per manufacturer's instructions and as directed.
All same as per item No 1 here-in-above but 100 KVA capacity at TB-IV (North) pump house -do-
All same as per item No 1 here-in-above but82.5 KVA capacity at FIU Lab
All same as per item No 1 here-in-above but 63 KVA capacity 598 PH
All same as per item No 1 here-in-above but 45 KVA capacity at VIP NO-2 PH Collage.
All same as per item No 1 here-in-above but 40 KVA capacity at AT RECORD Collage
All same as per item No 1 here-in-above but 30 KVA capacity at 100 Map Domlur
All same as per item No 1 here-in-above but 30 KVA capacity at EME WORKSHOP Collage
All same as per item No 1 here-in-above but 30 KVA capacity at Meeret Block
All same as per item No 1 here-in-above but 25 KVA capacity at PH-NO1 Collage
All same as per item No 1 here-in-above but 25 KVA capacity at TB-IV PH (N)
All same as per item No 1 here-in-above but 20 KVA capacity at 70 MAJ Map Ph
All same as per item No 1 here-in-above but 20 KVA capacity at Domlur Pump House
All same as per item No 1 here-in-above but 5 KVA capacity VOC/VNC
All same as per item No 1 here-in-above but 15 KVA capacity BAffle Range NOTES BOQ item Nos 1 to 15 : :- (i) Control switches such as MCCB, Main switch, contactors and multi display meter shall be out of scope of the item of work and the rate quoted shall exlusive of servicing/ maintenance of the above said DG sets/ fittings. (ii) Servicing of DG set alongwith connected alternator RA attached and control panel including 'A' check of the Engine shall be carried out at regular intervels as per manufacturers instuctions & as directed by the Engineer-in-Charge and the contractor shall carry out periodical inspections during the maintenenace period and he shall be responsible for the smooth functioning of the DG set during entire contract period. (iii) The Spare parts required for replacement during the maintenance/ servicing the same shall be measured and paid separately at supply only rates here-in below and the cost of labour for fixing these spares shall be deemed to be inluded in the rate quoted for the respective items. (iv) Cost of all consumablessuch as cotton , grease , lubricants etc required during the maintenance period shall be deemed to be included in the rate quoted for this item. (v) The contractor shall also attend to the breakdown calls and depute necessary technician for repair/maintenence works as and when required with out delay during the maint period. (vi) List of checks to be carriedout under 'A' check is attached as Appendix 'A' to the Particular specifications.
M&L for carrying out scheduled 'B' check of 100 KVA capacity Diesel Generator Sets at FIU lab including connected alternator and carrying out routine servicing of the engine as per manufacturer's instructions including consumables complete for smooth functioning of the set all as specified and as directed. Note for item No. 2 :- (i) Cost of all consumables required during the servicing / maintenance of the DG Set shall be deemed to be included in the rate quoted for this item. (ii) Spare parts, filter elements, engine oil, distilled water and radiator coolant liquid required for replacement during the maintenance period shall be measured and paid seperately at supply only rates and cost of labour for fixing these spares/filling of oils shall be deemed to be included in the rate quoted for this item. (iii) AMF Panel and control switches such as MCCB, Main switch, contactors, multi display meter and engine control unit shall be out of scope of the item of work and the rate quoted shall exlusive of servicing/ maintenance of the above said fittings. (iv) List of checks to be carried out under 'B' check is attached as Appendix 'B' to the Particular specifications. (v) List of checks to be carriedout under 'B' check is attached as Appendix 'B' to the Particular specifications.
All same as per item No 16 here-in-above but 100 KVA capacity at TB-IV (North) pump house.
All same as per item No 16 here-in-above but 82.5 KVA capacity at FIU Lab
All same as per item No 16 here-in-above but 63 KVA capacity 598 PH
All same as per item No 16 here-in-above but 45 KVA capacity at VIP NO-2 PH Collage.
All same as per item No 16 here-in-above but 40 KVA capacity at AT RECORD Collage
30 KVA capacity at 100 Map Domlur
All same as per item No 16 here-in-above but 30 KVA capacity at EME WORKSHOP Collage
All same as per item No 16 here-in-above but 30 KVA capacity at Meeret Block
All same as per item No 16 here-in-above but 25 KVA capacity at PH-NO1 Collage
25 KVA capacity at TB-IV PH (N)
All same as per item No 16 here-in-above but 20 KVA capacity at 70 MAJ Map Ph
All same as per item No 16 here-in-above but 20 KVA capacity at Domlur Pump House
All same as per item No 16 here-in-above but 15 KVA capacity VOC/VNC
All same as per item No 16 here-in-above but 15 KVA capacity BAffle Range Note for BOQ item Nos. 16 to 30 :- (i) Cost of all consumables required during the servicing / maintenance of the DG Set shall be deemed to be included in the rate quoted for this item. (ii) Spare parts, filter elements, engine oil, distilled water and radiator coolant liquid required for replacement during the maintenance period shall be measured and paid seperately at supply only rates and cost of labour for fixing these spares/filling of oils shall be deemed to be included in the rate quoted for this item. (iii) AMF Panel and control switches such as MCCB, Main switch, contactors, multi display meter and engine control unit shall be out of scope of the item of work and the rate quoted shall exlusive of servicing/ maintenance of the above said fittings. (iv) List of checks to be carried out under 'B' check is attached as Appendix 'B' to the Particular specifications.
Supply only fuel filter elements with 'O' Rings for following DG sets:- 100 KVA 85 KVA Capacity DG Set
All same as per item No 31 here-in-above but 63 KVA to 45 KVA capacity -do-
All same as per item No 31 here-in-above but 40 KVA to 30 KVA capacity -do-
All same as per item No 31 here-in-above but 25 KVA to 15 KVA capacity -do-
Supply only lub oil / engine oil filter/catridges as per existing one or as directed for 100 - 85 KVA Capacity DG Set
All same as per item No 35 here-in-above but 63 KVA - 45 KVA Capacity -do-
All same as per item No 35 here-in-above but 40 KVA - 30 KVA Capacity -do-
All same as per item No 35 here-in-above but 25 KVA - 15 KVA Capacity -do-
Supply only Maintaince free battery with PVC body 12 volt 100-130 AH
Supply only the following materials required for maintenance of DG Sets :- Coolant Concentrate
40.01 battery Electrolyte Grade 1250
40.02 Distilled water
40.03 Cotton Waste Superior quality
Supply only fan belts of make as per existing or as approved by Engineer-in-charge for 100 KVA - 85 KVA capacity DG Sets
44.01 DG Set of capacity 45 KVA to 63 KVA
44.02 DG Set of capacity 15 KVA to 40 KVA
M & L for de-scaling of radiator assembly by disconnecting and removing from eingine, opening the top & bottom chambers, descalling the sediments and scales, corrosion etc and cleaning the core pipes with cleaning chemicals (raditor wash) and high pressure water washing and arresting the leakage in core, if any, by brazing / dummy with lead, compressed air cleaning, reassembling the same with new gasket, and fixing to the engine with new hose pipe and clipes as reqd and filling radiator with coolent complete all as directed for 100 KVA - 85 KVA Capacity DG Set Note : The rate qouted shall be inclusive of transporting of the radiator to the workshop and back and all incidental charges. The coolant required for filling will be measured and paid seperately under respective item of this schedule.
All same as per item No 47 here-in-above but 45 KVA - 63 KVA capacity -do-
All same as per item No 47 here-in-above but 15 KVA - 40 KVA capacity -do-
Taking out old unserviceable radiator from the engine and supply and fixing of new radiator of same type ,size and make , connecting coolant hose pipes for inlet and outlet etc and refilling sufficient new coolant as ordered and testing on completion to the entire satisfaction of Engineer-in-charge for 63-45 KVA Kirloskar DG set .
Supply only voltage monitering regulator (UV, OV, SP) of suitable ratings for AMF panels
Dismantling/repairing the cylinder head assy of 45 KVA DG Set Kirloskar by stripping out the head assy from engine and carrying out the machining work such as head surfacing pressure testing, valve seat angle facing, lapping replacing the rusted water plugs and fixing the new brass water plugs etc., and replacing the worn out parts like inlet & exhaust valves, guides, valves seat inserts, head gaskets, stem seal, silicon "O" rings and reassembling the engine after replacing following spares and testing to its full efficiency including transportation all as directed (a) Valve (Inlet & Exhaust) - 6 Pair (b) Valve Guide - 8 Nos. (c) Valve seat - 8 Nos. (d) Stem Seal - 8 Nos. (e) Set of copper washer - 1 set (f) Set of O Ring 1 Set (g) Set of gasket - 1 set (h) Copper head casket - 1 Set
Dismantling/repairing the cylinder head assy of 25 KVA DG Set of Kirloskar make by stripping out the head assy from engine and carrying out the machining work such as head surfacing pressure testing, valve seat angle facing, lapping replacing the rusted water plugs and fixing the new brass water plugs etc., and replacing the worn out parts like inlet & exhaust valves guides , valves seat inserts, head gaskets, stem seal, silicon "O" rings and and reassembling the engine after replacing following spares and testing to its full efficiency including transportation all as directed (a) Valves - 8 Nos (b) Valve Guide - 12 Nos. (c) Valve seat - 12 Nos. (d) Stem Seal - 12 Nos. (e) Set of copper washer - 1 set (f) Set of O Ring - 1 Set (g) Set of gasket - 1 set (h) Copper head casket - 4 Nos.
Supply only Voltage Regulator (AVR) suitable for DG set of capacity 100 KVA to 125 KVA
Supply only Voltage Regulator (AVR) suitable for DG set of capacity 45 to 63 KVA
Supply only Voltage Regulator (AVR) suitable for DG set of capacity 40 to 15 KVA
Supply only Low Oil pressure Switch 12 Volt as per the existing switch
Supply only stopping solenoid 12 Volt suitable for 100 KVA - 85 KVA DG sets
All same as per item No 58 here-in-above but 45 KVA - 63 KVA Cpacity DG Set
All same as per item No 58 here-in-above but 15 KVA - 40 KVA Capacity -do-
Supply only Banjo bolts of suitable sizes
Supply only fuel tank filter
Supply only anti vibration pad
Supply only Radiator hose flexible suitable for 100 - 85 KVA Capacity DG Sets
All same as per item No 64 here-in-above but 45 KVA - 63 KVA capacity -do-
All same as per item No 64 here-in-above but 15 KVA - 40 KVA capacity -do-
Supply only Hose plain for water pump suitable for for 100 - 85 KVA Capacity DG Sets
All same as per item No 67 here-in-above but 45 KVA to 63 KVA -do-
All same as per item No 67 here-in-above but 15 KVA - 40 KVA -do-
Supply only DC Ammeter of Range 0-10 A
Supply only Lube oil pressure gauge of suitable range
Supply only starter motor assembly for 45/25 KVA, 12 Volt DC
Supply only Air Filter elements of DG set 100 KVA - 85 KVA capacity
All same as per item No 73 here-in-above but 45 - 63 KVA -do -
All same as per item No 73 here-in-above but 15 KVA - 40 KVA -do-
All as per item No 76 here-in-above but 100 KVA capacity at TB-IV (North) pump house -do-
All as per item No 76 here-in-above but 82.5 KVA capacity at FIU Lab -do-
All as per item No 76 here-in-above but 63 KVA capacity 598 PH -do-
All as per item No 76 here-in-above but45 KVA capacity at VIP NO-2 PH Collage.-do-
All as per item No 76 here-in-above but 40 KVA capacity at AT RECORD Collage -do-
All as per item No 76 here-in-above but 30 KVA capacity at 100 Map Domlur -do-
All as per item No 76 here-in-above but 30 KVA capacity at EME WORKSHOP Collage -do-
All as per item No 76 here-in-above but 30 KVA capacity at Meeret Block -do-
All as per item No 76 here-in-above but 25 KVA capacity at PH-NO1 Collage -do-
All as per item No 76 here-in-above but 25 KVA capacity at TB-IV PH (N) -do-
All as per item No 76 here-in-above but 20 KVA capacity at 70 MAJ Map Ph -do-
All as per item No 76 here-in-above but 20 KVA capacity at Domlur Pump House -do-
All as per item No 76 here-in-above but 15 KVA capacity BAffle Range -do- Note for Item No. 76 to 89 :- i) The rate deemed to be included all the minor spares such as screws, washers, clips etc and all other spares required will be measured and paid seperately under supply only items. ii) General maint shown above are indicative only, contractor has also to do any other maint task required at site as directed by Engr-in-Charge. iii) The contractor has to attend the breakdown calls and depute technician as and when required without any delay to keep the DG set 100% serviceable all the times as directed by Engr-in-Charge.
Filling only Engine Oil 20W-40 all as directed. Note - Engine oil will be issued under Sch 'B' free for fixing only.
Supply only electronic timer for on delay function 12VDC/240VAC with time range 0.3 Sec to 30 Min. Make: EAPL or equivalent suitable for panel.
Supply only relay 12 V DC 8/11pin. Make : PLA or equivalent suitable for panel.
Supply only HRC fuses of capacity 4-20 Amps.
Supply only HRC fuse cartidge assembly both base and top 20 A rating.
Supply only indicator lamps DC 12V LED type
Supply only indicator lamps AC 230 Volt LED type
Supply only push button with contact element 5 A with NO-NC
Supply only Analog Ammeter as per sample of range -/5A CT Operated for control/AMF panel
Supply only Analog Volt Meter as per sample of Range 0-600 Volts AC.
Supply only Frequency meter vibrating reed of Range 45-55 HZ.as per exisisting make
Supply only Frequency meter Digital type LED type of Range 45 Hz -55 HZ. as per exisisting make
Supply and fix in repairs power contactor 4 Pole Existing type 100/85 KVA AMF Panel including disconnecting and removing existing defective item from electric circuit including necessary connected fastners, burnt cables, accessories etc,. all as per site requirement/existing make/model all as specifed and as directed.
All as per item No 103 here-in-above but power contactor 4 Pole suitable for 40/63KVA for AMF Panel.
All as per item No 103 here-in-above above but power contactor 4 Pole 30/20 KVA DG set
All as per item No 103 here-in-above but Axilary contactor 4 Pole 100/85 KVA DG set
All as per item No 103 here-in-above but type of Axilary contactor 4 Pole suitable for AMF panel of 40/63 KVA DG set
All as per item No 103 here-in-above but type of main contactor 4 Pole suitable for AMF panel of 30/15 KVA DG set
S&F in repairs operating coil for contactor suitable 100 to 85 KVA DG sets
S&F in repairs operating coil for contactor suitable 40 to 63 KVA DG sets
S&F in repairs operating coil for contactor suitable 15 to 30 KVA DG sets
S&F Battery charger SMPS type 12 Volts 18 Amps 240 Volts suitable for AMF Panels/. For Battery charging Make : NHP/equivalent
M&L for repair and servicing of charging alternator / dianamo of DG set of 100/85 KVA DG set after removing from the engine and transporting to an auth service centre, dismantling, removing unsv parts like diode, bush/bearing, carbon brush etc, cleaning reassembling with new parts as required and refitting to the engine and testing complte all as directed.
All as per item No.113 here-in-above but capacity of DG set 40 to 63 KVA
All as per item No.113 here-in-before but capacity of DG set of 15 KVA to 30 KVA
Supply only ignition key suitable for DG set panel/control panel.
M&L for repair / overhauling of self starter assembly 12 Volts of DG Set 100/85 KVA by disconnecting and removing from the engine, cleaning all accessories, replace the wornout parts like bendix drive, brushes, bushes, contact plates, jumping leads and seals, re-varnishing the field coil, armature and reassembling the same, refitting to the engine and testing complete all as directed .
M&L for repair / overhauling of self starter assembly 12 Volts of DG Set of 40 KVA to 63 KVA by disconnecting and removing from the engine, cleaning all accessories, replace the wornout parts like bendix drive, brushes, bushes, contact plates, jumping leads and seals, re-varnishing the field coil, armature and reassembling the same, refitting to the engine and testing complete all as directed .
M&L for repair / overhauling of self starter assembly 12 Volts of DG Set of 15 to 30 KVA by disconnecting and removing from the engine, cleaning all accessories, replace the wornout parts like bendix drive, brushes, bushes, contact plates, jumping leads and seals, re-varnishing the field coil, armature and reassembling the same, refitting to the engine and testing complete all as directed .
Material and labour for repair work to exhaust system including replacing aluminium clading, glass wool wherever necessary and necessary reviting work for 100 KVA - 85 KVA Capacity DG Sets.
All same as per item No 120 here-in-above but 40 - 63 KVA capaacity -do-
All same as per item No 120 here-in-above but 15 KVA to 30 KVA capacity -do-
M&L for cleaning throughly and preparing surface by removing rust, dust and oil, and painting of complete for the following DG Set with including acoustic enclosure two coats of existing colour code including control / AMF panel board complete all as specified and directed by Engr-in-Charge. Note:- (i) Painting should be done with existing colour codes and paint should apply with the help of spary gun using air compressor including writing SM/MES Number on prominent places of DG & Alternators. 45/15 KVA capacity (ii) Quotated rate shall deemed to be inclusive of preparation of old painted surface and applying zinc chrome primer in patches over rusted portion all as directed.
Supply and fix in repairs MCCB 3 pole 25 to100 Amps 16 KA in LT panel boards / feeder pillar boxes including disconnecting and removing existing defective item from electric circuit including necessary connected fastners, burnt cables, accessories etc all as per site requirement/existing make/model all as specifed and as directed.
Supply and fix in repairs MCCB 3 pole 125 Amps 25 KA in LT panel boards / feeder pillar boxes including disconnecting and removing existing defective item from electric circuit including necessary connected fastners, burnt cables, accessories etc all as per site requirement/existing make/model all as specifed and as directed.
Supply and fix in repairs MCCB 3 pole 200 Amps 36 KA in LT panel boards / feeder pillar boxes including disconnecting and removing existing defective item from electric circuit including necessary connected fastners, burnt cables, accessories etc all as per site requirement/existing make/model all as specifed and as directed.
supply and fix in repairs change over switch 4 pole 125 A without enclosure in LT panel boards / feeder pillar boxes including disconnecting and removing existing defective item from electric circuit including necessary connected fastners, burnt cables, accessories etc all as per site requirement/existing make/model all as specifed and as directed. Make: L&T, HAVELLS, STANDARD, INDO ASIAN
Supply and fix in repair change over switch 4 pole 125 A with enclosure. out door type for bypass supply all as per site requirement complete all as specifed and as directed. Make : L&T, HAVELLS, STANDARD, INDO ASIAN
Supply and fix in repair change over switch 4 pole 63 A with enclosure. out door type for bypass supply all as per site requirement& all as specifed and as directed.Make : L&T, HAVEL, STANDARD, INDO ASIAN
Supply only microprocessor based AMF controller unit for AMF Panel flush mounting type all as specified. Make - Deep Sea Electronics or equivalent
Excavation in trenches in hard/dence soil,not exceeding 1.5 Mtr wide and not exceeding 1.5 mtr in depth and geting out in hard/dense soil complete all as directed.
Returning filling in including spreading, leveling, watering and well ramming in layers not exe. 25 cm.
Removing exacavated surplus excavated material to a distance exceeding 50m and depositing where directed at a level not exe. 1.5 m above the starting point.
M & L for river sand cushioning to underground cables in trenches including spreding ,levelling, hand punning and consolidating complete all as specified and directed. Note : Punned thickness shall be considered for measurement purpose
Supply and lay common burnt old size bricks of sub class B laid at right angle on the cable complete in trenches for cable protection complete all as directed by Engr-in-charge.
Supply & laying XLPE insulated, PVC sheathed, strip armoured electric cable with stranded aluminium conductor working voltage upto1100 volt of 10 Sqmm 2-core as per IS 7098 Pt I in trenches, culvert, through pipe etc including connecting both end with proper size of alluminium lugs duly crimped with die press crimping device and cable gland complete all as specified and directed by Eng-in-charge.Note Excavation, earth work, sand cushioning, cable cover, returning/filling will be measured and paid seperately).
All as per item No 136 here-in-above but cable of size 10 Sqmm 4 core.
All as per item No 136 here-in-above but cable of size 16 Sqmm 4 core.
All as per item No 136 here-in-above but cable of size 25 Sqmm 4 core.
Supply and fixing in replacement Mild steel galvanized pipe light grade for protection & passing of LT cable fixed to poles/walls/laid under floor/roads complete including fittings/clamps as required at site all as specified for size of 25 mm bore dia.
S&F in replacement MCB 4 pole 63 Amps, 415 Volts all as directed..Make- Indo asian optium /Havells/siemens
S&F in replacement MCB 4 pole 40 Amps, 415 Volts all as directed..Make- Indo asian optium /Havells/siemens
S&F in replacement MCCB 4 pole 63 Amps, 415 Volts, 25 KA breaking capacity, with adjustable thermal and fixed magnetic release all as directed..Make- Indo asian optium /Havells/siemens
S&F in replacement MCCB 4 pole 100 Amps, 415 Volts, 25 KA breaking capacity, with adjustable thermal and fixed magnetic release all as directed..Make- Indo asian optium /Havells/siemens
S&F in replacement MCCB 3 pole 160 Amps, 415 Volts, 25 KA breaking capacity, with adjustable thermal and fixed magnetic release all as directed..Make- Indo asian optium /Havells/siemens
Trimming/cutting of the tree branches/bushes which falls within a clear distance of 3 meter from all sides from the HT/LT over head conductor & within line of conductors, and shifting waste to nearby waste depot & cleaning area complete . Note : Horizontal distance of tree touching to the over head lines shall be measured for the purpose of payment.
Fabricate, install and testing in replacement factory made, pole mounted canopy headed single door outdoor type, weather proof totally enclosed street light controlling panel of size 55cm x 50cm x 40cm suitable for 3 phase 4 wire 440 volts made out of 3 mm thick CRCA sheet, cubical type, powder coated paint inside and outside, having front hinged door with neoprene rubber gasket including danger notice board/plate earth terminal point, bottom detachable gland plate with holes for incomming and outgoing cables provision fixing arrangement with clamps made out of Mild Steel flat iron 40X5mm including bolts & nuts, including internal connection by using suitable size copper conductor cable complete with the following accessories:- (a) MCCB, 4 pole, 415 volts, 25 kA, 63 Amps Capacity with thermal load release relay- 1 No (for incoming) (b) Astro type time switch 110-240 volts suitable for 24 hours operation of street light. Make : - L&T/ Legrand/Havells/ABBB (c) Contactor three pole 40 Amps 415 volts coil operating voltage 230 volts. Make L&T MNX 40 or equivalent of Legrand/Havells/ABB (d) Auto manual switch 10 Amps - 02 Nos. Make : - L&T/Legrand/ABB (e) MCB TPN 32 Amps, 10 KA, 'C' curve - 02 Nos
Supply, fabrication, installation and testing of LT out door type factory made(CPRI Approved ), junction box of size 900mm(H)X700mm(B)X400mm(W) (over all dimension ) made out of 3.0mm thick CRCA sheet dully supported with mild steel angle iron of size 40X40X5 mm frame, 04 Nos aluminium bus bar of of capacity 250 Amps with drilled hole for incoming/outgoing cable connection with necessary aluminium lungs, GI nuts bolts and washer including 08 Nos bridge insulator DMC , heavy duty, suitable for 3 Phase 4 wire system, one danger notice plate of 1.6mm thick mild steel sheet, vitreous enameled white with letters, figures and conventional skull & bones in signal red colour and fixed in front door size and PCC (1:3:6) type C-1 foundation 0.30m above normal ground level & 0.30m below ground level with necessary exacavation and earth work and painting to internal and external steel surface with powder coated (Siemence grey) RL-35 after neccesary preparation of surfaces including providing indicating lamp LED type 240V 50 Hz AC -one set of 3 Make: L&T/Legrand/ ABB/Siemens/Havells complete all as directed.
S&F New generation, post-top,lattern landscape luminaire 15 watts, energy saving, powder coated aluminium die cast and spun aluminium body with clear/opel diffuser ,environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium with high power LEDs as light source, IP -65 all as directed.Make: Havells cat No RUBYMIMIPT15WLED830PSYMTOPC or equivalent make of Phillips/CG/Bajaj .
M&L for PCC 1:3:6 type C2 using 40 mm graded stone aggregate for mass filling in pole pit, coping and foundation etc, complete all as specified and directed.
Supply and fix LED street/building light fitting, 1x45 watts with highly effective and efficient luminaire rubust design IP-66 fixed on walls with all fixing accessories such bend pipe, square/round blocks, clamps/screws, etc and connecting up with three core round flexible copper conductor cable of size 1.5 sqmm complete all as specified and directed. Make Havells/Phillips/Surya
Supply and fix LED street/building light fitting, 1x60 watts with highly effective and efficient luminaire rubust design IP-66 fixed on walls with all fixing accessories such bend pipe, square/round blocks, clamps/screws, etc complete all as specified and directed. Make Havells/Phillips/Surya
S&F energy saving environmental friendly long life, with highly effective and efficient luminaire robust design LED street/building security light 1x 70 Watt LED pressure die-cast aluminium, heat resistant, toughened glass diffuser, IP65/66 and wired with all accessories and connection up with 3 core flexible copper conductor cable 4/20 mm size, 1.5m long and testing on installation all as specified and directed. Make: Havell's Cat No. ENDURACITYLINERNEOSL70WLED757PASYBOTG or equivelant of make Bajaj/CG/Shakti/Wipro
S&F energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium iP65 flood light with high power leds as light source, suitable for highlighting architectural facade highmast and general purpose lighting of 120 watt lamp with all accessories for fixing on pole/wall and electrical connection. Make Havells/Phillips/Surya
M&L for GI tubing Bracket 40mm medium grade 1.5 mtr lenth,bent to 120° shape including grouting/fixing 2-Nos clamps required size,including bolts for fixing street light complete.
Supply & fix in repair FRP junction box (weather proof) of size 240 x 130 x 110mm including four pole connector arrangement alongwith suitable clamps including MCB SP.6 Amps 10 KA rating,fixing with flat iron clamps, nuts and bolts complete all as specified and directed. Make : Sintex or equivalent
Supply and fix, in repair PVC insulated three core,1.5 Sqmm cables with copper conductor copper flexible cable with earth conductor complete all as specified and directed.Make : poly cab/Havells/finolex
Supply and fix in repair Rigid Non-metallic PVC conduit pipe exclusive of junction boxes but inclusive of all Tees,bends elbows,reducers, bell mouth tube end and fixing acessories such as couplers, lock nuts,saddles pipe hooks etc and fixing to poles etc of size 20 mm external dia. etc all as specified.
Taking down old unserviceable light fitting HPSV/LED street light fitting of any make and type complete with accessories opening and checking defective/unserviceable accesssories/spare parts and replacing the same with new one as per existing after cleaning dust from internally & externally surfaces of light fittings including cleaning of acrylic cover cover, refixing the light fitting in same position including testing on completion to the satisfaction of Engineer-in-charge complete all as directed. Note : (i) Spare required to make the light fitting functional shall be measured and paid seperately as "Fixing only" under respective items here-in below. (ii) The quoted rate is deemed to be inclusive of fixing any spares in said item , please note that no seperate shall be paid for labour. (iii) The cost of bolt, nut & washers etc required if any shall be deemed to the included in quoted rate of respective item.
Fixing only Sodium vapour lamp 150 watts, 230 volts of make as approved.
Fixing only Ballast any type suitable for 150 watts HPSV street light fittings
Fixing only capacitor 20MFD suitable for 150 watts HPSV street light fittings
Fixing only Ignitor suitable for Street/security light fittings HPSV type 150 watts
Fixing only LED Driver 240 Volt 200 Watt for street light / Flood light as per existing make / model complete all as directed.
Fixing only LED Driver 240 Volt 60/80 Watt for street light as per existing make / model complete all as directed.
Fixing only LED Driver 240 Volt 25 /45 Watt for street light as per existing make / model complete all as directed.
Cleaning/desludging of raw sewage in under ground sump well up to the depth of 5 Mtr inclduing screening chamber and various sewage pumping installation by closing main incoming manhole and pumping out raw sewage to neat drain by using portabale non clog pump set, cleaning of raw sewage sump by manually or mechanically using (spl T&P such as movable sewage cleaning tanker) scrapping inside wall and bottom by steel wire bush to remove raw material and transport it to outside cantonment area for disposal at low lying area up to the distance of 10 Kms at his own arrangment where the sanitary hazard do not take place and as per guidelines of civil authority all as directed for disposal. Thereafter cleaning/washing of interior surface of UG sump using high grade bleaching powder and lime mixed water incl painting with two coat of cement based paint.
Supply & replacement of Air blower oil.
S&F in repair for Butterfly valve, non-rising type conforming to IS-14846, sutiable for 150 mm bore pipe consisting of SS spindle as per IS 6603, Cast iron Body, Dome & Wedge as per IS 210, greasy jute type gland packing, fasteners as per IS 1367, Natural rubber gasket, CI manual hand wheel etc complete double end flanged and drilled, of Class PN-1.0 ( ISI marked) including all jointing materials such as rubber gasket insertion sheet nut ,bolts and washers etc complete all as specified and directed. Make : Kirloskar / Venus / Shakti / Upadhyaya
All as per Item No 115 here-in-above but of 100 mm dia complete. Make : Kirloskar / Venus / Shakti / Upadhyaya/BIR
All as per Item No 115 here-in-above but but of 80 mm dia complete. Make : Kirloskar / Venus / Shakti / Upadhyaya/BIR
S&F in repair Cl swing check NRV conforming to IS-5312, sutiable for 150 mm bore pipe consisting Cast iron Body, door as per IS 210, Bronze body ring as per IS 318, natural rubber door face, hinge pin SS ASTM A276 type 410, fasteners as per IS 1367, Natural rubber gasket, etc complete double end flanged and drilled, of Class PN-1.6 ( ISI marked) including all jointing materials such as rubber gasket insertion sheet nut ,bolts and washers etc complete all as specified and directed. Make : Kirloskar / Venus / Shakti / Upadhyaya/BIR
All as per Item No 118 here-in-above but but of 80 mm dia complete Make : Kirloskar / Venus / Shakti / Upadhyaya/BIR
All as per Item No 118 here-in-above but of 100 mm dia complete Make : Kirloskar / Venus / Shakti / Upadhyaya/BIR
M & L for painting after scraping of old dull paints from the steel surface by scretching by wire brushes over any width or girth of MS pipes, CI pipe, valve, motor, pump dozer etc and applying two coats of synthetic enamel paint by brush application as per colour code as per exixting or as ordered by by Engineer-in Charge and finally writing MES/SM No at location where directed on the following items :-(i) Pipe lines of size 80 mm to 200 mm dia including stairs,Gate and GI railing - 30RM (ii) LT Panel Board- 05 No (iii) Non clog submersibale pump/Centrifugal pump set with accessories etc - 04 No
M & L preparing and cleaning the joints of RCC pipe after removing existing treatment and applying sufficient qty of leak proof cement compound (Dr Fixit) as per manufacturers instructions or as ordered to stop the leakage RCC pipe upto 600mm dia including testing on completion & finally apply a coat of cement base adhesive paint complete all as directed. (Note : Quoted rate is deemend to be inclusive of leak proof compound & cement base adhesiive painting)
Testing of sewage effluent at the (inlet of raw sewage sump and equalization tank and out let of chlorine mixing tank) sampling and analysis to be carried out by NABL accredited authorized LAB per IS - 3025 for essential parameters such as BOD/COD Note: Sample of raw sewage & post treatment sewage water to be collected by contractor in presence JE E/M and submitted result of the test . (Note :(i) Quoted rate is deemed to be inclusive of testing . (ii) Please note that payment for the said item shall be entertained only after receipt of satisfactory test results).
Repair/dechoking of choked sewage lines at sewage treatement plant with the aid of clearing rod,Brush and heavy duty submersible pump of any Cap and testing the entire STP sewage line for choking for minimum period of 8 Hours and rectifying the defects noticed all as per directed and specified by Eng-in-Charge.(Note : Quoted rates is deemed to be inclusive of dismantling of any elbow,sluice valve and pipe line if found necessary for dechoking of pipe line and also assembling the same complete and necessary Items,dewatering of sewage ,cleaning etc)
M&L for replacement of existing of high quality Mild steel mesh for raw sewage well of suitable size as required and specified by Engr-in-Charge
Repairs to leakage with antitoxic chamical solvent to stop water leakage ( of approval company i.e pidilite after removing by mechanically scarifying the the surface for receiving the epoxy. The leakage surface shall completely be removed preferebly with brush before laying of coating alongwith scaffolding and labours safety arrangement complete all as specified and directed.
Supply only stable Calcium hypochloride Grade I,availabilty Chlorine 34 % min,Stability 1/15 Max,moisture 0.3% max etc all as per IS Make: Lion/ Shriram (DCM) or equivalent as approved by GE
Removing old filter media complete (Quartz sand gravel and activated carbon in granular form) of size 1200 mm to 1800mm sizes complete in layers or as specified by OEM and incl scraping the internal surfaces of sludge drying beds with wire brush,and cleaning with bleaching powder slurry, cleaning with fresh water including applying one coat of white wash on external surface of sludge drying bed and re-filling up with new filter media in layers all as per manufacturers recommendations/ existing incl testing and commissioning etc complete all as directed. Note: New filter media will be measured and paid separately under relevant SCh A item.
Supply only filter media complete Quartz sand gravel and activated carbon in granular form) of size 1200mmto 1800mm or as specified by OEM complete in layers as per existing
Servicing of 200/300 ltr capacity solar water heater with eelctric back up system after disconnecting the existing water supply/electrical connections from any height of the building , including stripping out the hot water vessel by taking out the outer cover insulating materials heating element cleaning the same materials with anti bacterical descalling and anticorrision spray painting where ever necessary and continous brazing of the inner container for arresting leakages including repalcement of defective / worn out spare parts and re-assembling the system and re- installed at the same laoction connecting up water/ electrical connections and testing to the satisfaction of Engineer-in-charge complete all as specfied and as directed.
All as per item No 130 here-in-above but 500 Ltrs capacity sloar water with electric back up system Note for item No 130 & 131 :- Serving of flat plate collector shall be measured and paid seperately under respective items of this shedule.
Servicing/cleaning of 200/300 ltrs capacity Solar flat plate collector box after disconnecting the existing water supply from any height of the buliding dismanting the box cleaning and serving the aluminium channels /sheets /angels and solar glass panel including repalcement of defective/worn out components and re-assembling the box connecting up water connections copper header/riser pipes nozeels etc cleaning the same materials with anti bacterical descaling and anti corrrision spray painting where ever necessary and testing for satisfactory performance complete all as specfied and as directed.
All as per item number above but 500 ltrs capacity solar flat plate collector box Note for item No 132 & 133 : (i) Replacement of solar glass panel if required shall be measured and paid separately under respective items of this schedule.
S & F heating element for solar water heater up to 500 litres with rubber gasket threaded push any type 230 V , 3KW fixied in repairs all as specified and as directed
S & F thermostat suitable of solar water heater up to 500 litres capacity and the range 0 to 80 degree centigrade fixed in repair all as specified and as a directed make Theeta/Racold/Philips ISI market
S & F 25mm thick bonded mineral wool pre-formed “SNAP ON” pipe sections of density 144 kg/cum conformining to IS 9842, Lagged around to hot water pipeline of 20mm bore fixed in repairs suitable for existing make all as specified and as directed
S&F 5mm thick toughned plain glass panels suitable for solar water heater plate colltor box , fixed in repairs suitable for existing make all as specified and as directed .
Supply & replacement of back up kit of solar water heater 3 KW including temprature gauge complete all as specified and as directed.
Supply and replacement of solar collector panel of 200ltr capacity for solar water heater complete all as specified and directed.
Supply and replacement of solar collector panel 300 to 500ltr capacity for solar water heater complete all as specified and directed.
Taking down wornout / unservicable GI pipe fixed in any description and provide new 40 mm bore steel water tubing medium grade (ISI marked) with fittings all new (ISI marked) fixed to wall and ceiling or laid in floors complete all as directed.
All same as per item No 195 here-in-above but 25 mm bore of pipe -do-
All same as per item No 195 here-in-above but 20 mm bore of pipe -do-
All same as per item No 195 here-in-above but 15 mm bore of pipe -do-
S&F in repair Gun metal gate or gate valves with iron wheel head screwed box and both ends for iron pipe for 40 mm bore of pipe or union complete all as directed.
All same as per item No 199 here-in-above but 25 mm size -do-
All same as per item No 199 here-in-above but 20 mm size -do-
All same as per item No 199 here-in-above but 15 mm size -do-
S&F in repair 20mm dia. cast copper alloy chromium plated Stop valves, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as directed.
S&F closing tap cast copper alloy chromium plated screwed for iron pipes of size 15mm dia including taking down old complete all as specified and directed
Taking down any type & capacity of water storage tank fixed in any description & supply & fix new 500 litres capacity rotational moulded polythene water storage tank, triple layer (cylindrical vertical with close top) Marked) including PVC float valve high pressure suitable for 25 mm bore of pipe with polythene float & flynut , fixture hoisted and fixed in position where ordered and making necessary connection and testing complete all as directed.
Supply and fixing in repair 1100 volts grade heay duty cable PVC insulated solid conductor 10Sqmm served with inner sheathing of PVC tape and over all PVC sheathed in service connections suspended by insulating hangers not more than 1 mtr apart including 4mm suspensions wire , one twin core cable flkat or circular.
S&F sheet metal enclosure SPN with two pole and earth metal plug and socket 20 Amps 240 Volts including provisions of one single pole MCB 20 Amps fixed in repairs complete all as specified and directed.
Servicing of any pump set 3 to 7.5 HP capacity including replacing of impeller, guide rings, neck rings, IP bush, bolts & nuts and lathe work etc complete all as directed. Note : (a) Rewinding of motor if required will be measured and paid separately.(b) Quoted rate shall deemed to be included the cost of removing and refixing of motor before and after rewinding/servicing.
M&L for dismantling the defective induction motor of any capacity/make/class of insulation from foundation bed, duly coupled with pump/compressor, trasnporting to workshop removing burnt out winding from stator/rotor, rewinding with suitable gauge of super enamelled copper wire of approved make and replacing DE /NDE bearings, insulation materials, varnishing , heating, complet painting of motor etc complete, re-assembling, testing and commissioning of 3 to 7KW capacity motors all as directed.
Supply and replace pressure gauge 0-10 kg/cm² ,4" dia internal glycerin filled including stop cock etc complete with necessary fittings incl disamntling old one all as directed. Make:- H-GURU /FIE BIG
Supply and replace pressure gauge 0-50 kg/cm² ,4" dia internal glycerin filled including stop cock etc complete with necessary fittings incl disamntling old one all as directed. Make:- H-GURU /FIE BIG
Supply on Flat copper cable 3 core 16 Sqmm multistranded conductor for submersible pump fixed in repairs and testing complete. Make - FINILUX
Shanthi Construction
Chandana Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .