Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹10.5 LAccepted-AOC H NO 2 ADARSH NAGAR ARJUN NAGAR NEAR MITTAL NURSING HOME AGRA 282001 | AGRA | AGRA | UTTAR PRADESH | 282001 | L-1 | Accepted-AOC Being L-1 | |
| 2 | L-2₹10.9 L+₹5,040 (0.46%)Rejected-Finance 37 A 19 3 B MADHU NAGAR AGRA UP | AGRA | AGRA | UTTAR PRADESH | 282001 | L-2 | Rejected-Finance Being other than lowest. |
Tender Value
₹16 L
EMD Value
₹32,000
Closing Date
22 Feb 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GEAFADMAREAAGRA
GEAFADMAREAAGRA
REPAIR MAINT OF SUMMER COOLING APPLIANCES AND ALLIED WORKS UNDER GE AF ADM AREA AGRA
2021_MES_418459_1
8000-1862/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GEAFADMAREAAGRA
Class E Cat c (i) and for un enlisted firm docus as per NIT
8 documents required · 8 mandatory
₹500
GEAFADMAREAAGRA
₹32,000
Yes
1 Mar 2021
3 Feb 2021
24 Feb 2021
3 Feb 2021
22 Feb 2021
10 Feb 2021
60 days
Amount
Supply & replacement to fins and tube type air cooled condenser suitable for split type AC cap of 1.5/ 2 Ton of any make complete all as specified and directed.
Supply & replacement of new fan motor for outside condenser unit of split AC of capacity 1.5 / 2 TR (Make- American Universal/ Khaitan/ Usha) complete all as specified and directed.
Supply and laying in replacement copper tube 1/4 inches dia for cooling unit to condensing unit for split A/C complete all as specified and directed.
Supply and laying in replacement copper tube 5/8 inches dia for cooling unit to condensing unit for split A/C complete all as specified and directed.
Supply and laying in replacement copper tube 1/2 inches dia for cooling unit to condensing unit for split A/C complete all as specified and directed.
S & F PVC pipe 20 mm bore heavy duty transparent flexible for drainage water system of split A/C complete all as specified and directed.
Supply and replacement of new blower fan motor of any type for cooling unit suitable for split A/C of capacity 1.5/ 2.0 TR of Make : Voltas/ Carrier/ American Universal / Usha / Khaitan complete all as specified and directed.
M&L for gas charging the system split type with correct quantity of R-134 gas for split A/C of 1.5 TR capacity for proper cooling i.e. 60 degree F with current rating of 09 to 12 Amps (Gas to be charged after carryout vaccum and pressure test for 24hrs including necessary brazing/soldering to prevent leakage ) including fixing the same in position and testing and commissioning complete all as specified and directed.
M&L for gas charging the system split type with correct quantity of R-134 gas for split A/C of 2/3 TR capacity for proper cooling i.e. 60 degree F with current rating of 11 to 13 Amps (Gas to be charged after carryout vaccum and pressure test for 24hrs including necessary brazing/soldering to prevent leakage ) including fixing the same in position and testing and commissioning complete all as specified and directed.
Servicing of both the indoor/outdoor units of split type A/C 1.5/2 TR capacity by cleaning filters removing internal dust by using vaccum cleaners, oiling greasing wherever required, checking for proper cooling complete including replacement of old u/s insulating material to the copper tubing (Foam covering) complete all as specified and directed.
Supply and replacing of U/S starting capacitor for blower motor 4 / 6 MFD for split A/C 1.5 TR / 2 TR capacity complete all as specified and directed. Make-Tesla/ Asian/ Keltron/ Sarda
Supply & fix starting capacitor 80/100 MFD suitable for reciprocating type compressor 1.5 TR/2 TR split A/C at site and making connection using PVC insulated copper wire and thimbles complete all as specified and directed. Make-Tesla/Asian/ Keltron/Sarada/Unistar.
Supply & fix running capacitor 36/45 MFD suitable for reciprocating type compressor 1.5 TR/2 TR split A/C and window AC at site and making connection using PVC insulated copper wire and thimbles complete all as specified. Make-Tesla/Asian/ Keltron/Sarada/Unistar.
Supply & fix running capacitor 50/60 MFD suitable for rotary type compressor 1.5 TR/2 TR split A/C and window AC at site and making connection using PVC insulated copper wire and thimbles complete all as specified and directed. Make-Tesla/Asian/ Keltron/Sarada/Unistar.
Supply and replacement of compressor for split type AC of capacity 1.5 TR reciprocating type of the existing make of Kirloskar or equivalent in LG/ Voltas/ Samsung
M&L for replacing of reverse cycle valve of cap 1.5 TR to 3 TR capacity of air conditioner functioning on refrigerant gas with electronic heating thermostat for cut off, overload protector and all necessary connecting work required for replacement in window/split type air conditioners for winter heating complete all as specified and directed.
Shifting of Split A/C cap 1.5/2TR including following works at site as directed by Engr in Charge :- (a) Dismantling the Split A/C (b) Fixing only cooling unit(indoor) & with grouting of suitable size of nut, olts and washers in side the wall (c) Fixing only condensing unit (out door) unit on suitable size of PCC plinth. (d) Supply and laying of copper tube of appropriate size from condensing unit to cooling unit including cutting chasses and concealed in wall as required. (e) Insulating copper tube 1/8" thick foam covering . (f) Charging the R-22 gas as required qty after welding ,brazing work and vaccum pressure, testing. (g) M&L for extension of water pipe by providing heavy duty pipe size 20mm/25mm.
Supply and replacing electronically controlled remote control with electronic PCB of 1.5/2/3 TR cap split AC of any make & any type (cordless or with cord) for smooth functioning of air conditioners through remote control complete all as specified and directed.
Carrying out the general servicing of window type A/C off sizes by cleaning the inner side of air conditioners with the help of air blower taking out the blower motor and refitting it back after washing with kerosene oil and oiling replacement of the unserviceable bushes cleaning the condenser thoroughly with water/cleaning chemical with help of brush replacement of the air filter.
Supply and replacement of compressor for split type AC of capacity 2 .00 TR reciprocating type of the existing make of Kirloskar or equivalent in LG/ Voltas/ Samsung Kirloskar or equivalent in LG/ Voltas/ Samsung
Taking down the old unserviceable front grills and supply and fixing new front grills of window type A/C 1.5 TR/2 TR capacity of any make as per site requirement to meet the existing complete all as specified and directed.
M & L for gas charging of window type A/C 1.5 TR/2TR with corrects quantity of R-22 gas so that grill temperature achieved to 60 degree F including vaccum pressure test to with stand for a period of 24 Hrs complete as specified and directed.
Supply and replacement of fins and tube type air cooled condenser suitable for window type A/C of capacity 1.5 TR/ 2 TR as of existing make complete as specified and directed.
Supply and replacement blower motor of any type 1/6 or 1/5 HP RPM 900 double soft suitable for any type of window A/C 1.5 TR/2 TR Make- American Universal / Cool Master/ Khaitan/ Usha.
Supply and replacement of propeller fan /impeller fan blade Assy (AL/PVC) of size as per existing fan and make for window A/C of any capacity.
Supply and replacement of Air sweep louver with motor complete set suitable for window type A/C of capacity 1.5 TR/2 TR.
Supply and replacement of Thermostat switch of window type A/C 1.5 TR/2 TR capacity including connection with appropriate size of PVC copper cables thimbles sleeves etc complete all as specified and directed. Make-Renutrol/Indofoss.
Removing burnt blower motor, off sizes from condensing/cooling unit of window/split type air conditioners 1.5 TR/2TR from the machines at site taking it to workshop dismantling & rewinding with super enameled copper wire using best quality winding materials bushes reassembling the motor replacing the bushes/bearing, starting, condenser, re-fixing the blower motor at site after testing and making connection complete all as specified and directed (Motor of ACs shall be of two speed).
Supply and replacement of compressor for split type AC of capacity 1.5 TR rotary type of the existing make suitable for Split type ac make - Hitachi or equivalent in LG/ Voltas/ Samsung
Supply and replace starting relays including connections complete for 1.5 TR or 2 TR capacity compressor of window type A/C all as specified and directed. Make – Ranutrol / Shri Ram.
Supply and replacement of compressor1.5 TR for Windo AC Reciprocating Tecumseh Model AW 1500/Emerson 1.5 TR Model CR 22 K 6M-PF1
M & L for supplying cutting and fixing waterproof ply wood 3 mm thick and making good the disturbed surface all as directed.
Shifting of window type AC of any capacity including cutting of suitable size space to accommodate the air conditioner at new position including necessary fixing material and making good the opening to match with the existing surface complete all as specified and directed.
Collection of the unserviceable refrigerator of capacity from site transportation it to AGE E/M Yard testing at AGE E/M Yard than transportation to local trade market to the authorized dealer/workshop replacement of u/s component/part testing for efficient cooling and shifting the refrigerator to its original position of following capacity :- Note :- Replacement of component/part/compressor and gas charging will be paid measured and paid separately. (a) 165 to 175 Ltrs Capacity
(b) 280/310 Ltrs
(c) 315/330 Ltrs double door
Supply & replacement of refrigerator compressors of following model including cutting compressor gas line welding/breezing, charging of gas with correct qt of R-12/R-134a gas to achieve the efficient cooling and smooth functioning at specified and directed :- (a) KCE 334 LAG model of Kirloskar or equivalent in LG/Hitachi for single door refrigerator of 165 to 175 Ltrs Capacity.
(b) KCN 349 LAG model of Kirloskar or equivalent in LG/Hitachi for single door refrigerator of 280/310 Ltr Cap
(c) KCN 372 LAG Model of Kirloskar or equivalent in LG/Hitachi for D/D refrigerator of 280/330 Ltrs Capacity.
Supply and replacement of thermostat switch for refrigerator of any capacity of best quality. Make-Renutrol/IND FOSS/LG.
Supply and replacement of box type relay for refrigerator of any capacity of best quality . Make-Renutrol / INDFOSS / LG.
M&L for charging the system with correct quantity of R-134 (a) gas for refrigerator of 165/286/310 Ltrs capacity for proper cooling (Gas to be charged after carrying out vaccum and pressure test for 24 hrs) complete all as specified.
Supply and fixing PVC stand for OFF sizes of refrigerators all as directed.
Supply and replacement of compressor for split type AC of capacity 2TR rotary type of the existing make Rotary Compressor suitable for Split AC 2 TR Make : Hitachi or equivalent in LG/ Voltas/ Samsung
Dismantling of water cooler, storage tank by unscrewing the outer body taking out the storage tank, carrying to local work shop and making it leak proof by means of breezing/soldering and assembling the water cooler after providing proper insulating material and breezing inlet and outlet wash out and over flow connections and testing complete for any leakage complete all as specified and directed.
Supply and fixing in replacement starting relayes for water cooler of capacity from 60 to 150 Litres all as specified. Make- RANUTROL/SHRI RAM/IND FOSS.
Supply and replacing thermostat switch of water cooler complete with connection using appropriate size of PVC copper cable sleeves thimbles etc complete all as directed for water coolers of capacity from 60 to 150 Litres.Make- RANUTROL /IND FOSS.
Removing the burnt condenser fan motor of water cooler of any capacity upto 150 Litre from the machine at site taking it to workshop, dismantling, rewinding with super enameled copper winding wire of appropriate size and best quality winding materials, replacing the worn out bearings, bushes, re-assembling the motor, replacing the starting condenser, refixing the blower motor in water cooler at site making connections complete and testing all as directed.
Supply and replacing condenser fan motor1/35 HP with blade 230V 50 Hz 1350 RPM suitable for water cooler from 40 ltrs capacity. Make:- KHETAN/USHA.
All as per item No 45.00 here-in-before but 1/10 suitable for 60 Ltrs capacity water cooler.
All as per item No 45.00 here-in-before but 1/5 suitable for 120 to 150 Ltrs capacity water cooler.
M&L for charging the system with correct quantity of R-134(A) Refrigerant Gas to water cooler so that required cooling of water is achieved for water coolers upto 150 Ltrs capacity (gas to be charged after carrying out vaccum and pressure test for 24 hours) complete all as directed.
Supply and replacement of new fins and tube type air cooled condenser suitable for any make of upto150 Ltrs capacity water coolers.
S&F ball polythene valves ISI marked high pressure with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed of size 15 mm complete all as specified and directed.
Supply and fixing in replacement of US compressor with new one suitable for water cooler of Capacity upto 150 ltrs including removing the old US compressor to MES store yard complete all as specified and directed by Engineer-in-charge Make : Tecumseh/kirloskar/LG/VOLTAS.
M&L Aluminium blade for condensing blower motor of water cooler any model/size ISI Marked as per site requirement.
M&L for cleaning and painting complete surface of desert cooler off size and applying one coat of red oxide primer internally and one coat of synthetic enamel paint on external surface of desert cooler of any make /size and capacity including writing of MES No not less than 25mm high and 2mm thick complete all as specified and directed.
Supply and fixing in replacement of the exhaust fan regulator for desert cooler of any size capacity including wiring complete all as specified and directed. Make-ANCHOR/KEY/CONA.
Supply and replacement of wood wool pads, PVC water pipe distribution and PVC pipe connection pieces for water distribution for desert cooler complete all as specified and directed.
Removing of existing burnt/unserviceable desert cooler pump from the desert cooler at site and replacement by supply and fixing new desert cooler pump submersible type heavy duty single phase including testing and commissioning complete all as specified and directed. Make Everest/Shakti/Crompton Greaves.
M&L for rewinding of desert cooler fan/exhaust fan electric motor of any make and capacity using existing gauge of super enameled copper wire including insulating material varnishing and connecting up complete all as specified and directed. Rate of fitting fixture deemed to be included in above rates.
Supply and replacement of detachable type perforated side panel 20 gauge of GI sheet including wood pads of desert coolers of all sizes as approved by Engineer-in-Charge.
Supply and replacement of front grills of desert cooler including Exhaust/Cooler fan regulator and piano type switch of size 18” x 18” each as per sample matching with the existing one.
S&F desert cooler body only complete with three side detachable type perforated panel leak proof water tank without any joint plastic distribution pipe system suitable for 1/3” dia PVC pipe to run water over pads made out of 20 gauge galvanized iron sheet duly painted with two coats of synthetic enamel paint over one coat of red oxide and overall dimension of desert cooler should not be less than size 65 cm x 65 cm x 75 cm with all accessories and front grills but without fan kit & pump motor and fan motor. (Water tank depth shall not be less than 20 Cm.)
Supply and fixing water proof wooden ply size 6mm thick cutting of ply wood in required sizes fixed on wall/cooler opening complete all as specified and directed.
Supply and fix MCB C series single pole & neutral 40 to 63 Amp 240 V Make- Havells / C & S/Legrand.
All as per item No 62.00 here-in-before but single pole 20 to 40 Amps 240 Volt.
M&L for sub main wiring drawing in and including PVC concealed conduit not less than 20mm dia medium grade with PVC cable 4 Sqmm nominal area 2 single core PVC insulated unsheathed cable with stranded copper conductor incl 4 Sqmm size PVC cable stranded copper conductor as earth continuity wire and connected to earth dolly all as specified and directed. Plaza/Kalinga/Havells/Finolex.
M&L for sub main wiring drawing in and including PVC concealed conduit not less than 20mm dia medium grade with PVC cable 6 Sqmm nominal area 2 single core PVC insulated unsheathed cable with stranded copper conductor incl 6 Sqmm size PVC cable stranded copper conductor as earth continuity wire and connected to earth dolly all as specified and directed. Make:- Plaza/Kalinga/Havells/Finolex.
Disconnecting of the existing voltage stablizers 1 KVA from the site/AGE E/M Yard to workshop for repair in the local market and refixing at the original position all as specified. Note :- Rewinding & replacement of parts/spares for stablizers shall be measured and paid under respective items.
S&F Sheet metal enclosure(AC BOX) with a two pin and earth plug socket and MCB SP 20 A complete all as specified and directed. Make : legrand/ABB/L&T.
Supply and fixing printed Circuit board of stabilizer 1KVA complete all as specified and directed.
Supply and replacement of MCB SP 40 Amp for stabilizer complete all as specified and directed.
Supply only capacitor 2.5 MFD, 230V AC complete all as specified and directed.
Servicing of assembly and erection of GI sheet of 22 gauge thick with TDF flange rectangular / square duct made out of 'L' shaped, hollow profile, duly factory boxed, including all accessories such as corner, cleat, carriage bolt, gasket, strengthening angle iron of suitable size & Length for supporting duct, air deliver controlled fins, suitable size of each air deliver duct complete all as specified and directed.
Servicing of heavy duty plastic body ductable table Air coolers (Which cools on the priciple of water evaporation) having option of air discharge from the top or bottom 200 liters water storage capacity exial fan with 1.1 KW, 3 phase, 50Hz Ac motor and 10000 CFM air flow capable to cool 1000 Sqft area with standard height of 10 feet. All sides of cooling cabinet shell be provided with 100 mm thick paper based honeycomb structure cooling media.complete all as specified and directed.
Repair / Replacement of heavy duty plastic body ductable table Air coolers Motor capacity exial fan with 1.1 KW, 3 phase, 50Hz Ac motor and 10000 CFM air flow capable to cool 1000 Sqft area with standard height of 10 feet. including fixing the same in position and testing and commissioning complete all as specified and directed.
Repair / Replacement of Submersible pump ( heavy duty Air Coolers ) including fixing the same in position and testing and commissioning complete all as specified and directed.
M/S J J ENTERPRISES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .