Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.3 LAccepted-AOC B 3 105 PASCHIM VIHAR NEW DELHI 110063 | WEST | DELHI | 110063 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹29.3 L+₹2.5 L (9.33%)Rejected-Finance RZ A2 2 CHANAKYA PLACE PART I OPP C 1A BLOCK JANAK PURI NEW DELHI 110059 | NEW DELHI | WEST DELHI | DELHI | 110059 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹29.9 L+₹3.1 L (11.7%)Rejected-Finance 19 62 1ST FLOOR WEST MOTI BAGH SARAI ROHILLA NEW DELHI 110035 | NEW DELHI | NEW DELHI | DELHI | 110035 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹30.1 L+₹3.3 L (12.2%)Rejected-Finance RZ 18 260 WEST SAGARPUR NEAR MCD SCHOOL NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹34.3 L+₹7.5 L (27.9%)Rejected-Finance WZ 409 0 B 1ST FLOOR PLOT NO 12 JANAK PARK HARI NAGAR NEW DELHI 110064 | NEW DELHI | WEST DELHI | DELHI | 110064 | L5 | Rejected-Finance Other than lowest |
Tender Value
Refer Docs
EMD Value
₹65,040
Closing Date
20 Nov 2020, 6:00 pmClosed
GE UTILITY PLANT AND MACHINERY DELHI CANTT-10
GE UTILITY PLANT AND MACHINERY KIRBY PLACE DELHI CANTT-10
REPAIR/ MAINT OF COOLING APPLIANCES AND VOLTAGE STABILIZER OF 274 TRANSIT CAMP, 1 AHQ, 1 CBPO, 3/5 GR, 35 INF BDE SIG COY, PMO ACCCS, CAMS, DGIS, WARDEC, 1 AHQ SIG REGT, DIGIT CAMS, 60 INF BDE ETC UNDER GE UTILITY PLANT AND MACHINERY, DELHI CANTT-10.
2020_MES_387333_1
GE(U)/PM/D-57/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
DELHI CANTT
MES contractor enlisted under class D category c(i) having deposited standing security of Rs 100000 with department. Contractor not enlisted in MES should meet the MES enlistment criteria corresponding to appropriate class and category
6 documents required · 6 mandatory
₹500
Yes
GE UTILITY PLANT AND MACHINERY DELHI CANTT-10
₹65,040
Yes
15 Dec 2020
17 Oct 2020
23 Nov 2020
17 Oct 2020
20 Nov 2020
6 Nov 2020
Amount
Taking down for servicing of split type AC 1.5/2 TR Capacity including cleaning of cooling coil, air filters/plasma filters etc, (Indoor unit), condenser, compressors, fan motor etc,(Out door unit) with vacuum cleaner OR cleaning solution including checking the serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, Remote control unit including PCB, fan, blower, etc., changing connections from heating mode to cooling mode or vice-versa and keeping the AC unit in satisfactory working condition after necessary servicing/ repair/ replacement of defective spares as required and refixing the same in existing position complete all specified and as directed by Engineer-in-Charge.
Taking down for servicing of Window type AC 1.5/2 TR Capacity including cleaning of cooling coil, air filters , condenser, compressors, fan motor etc with vacuum cleaner OR cleaning solution including checking the serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, remote control unit including PCB, fan, blower, etc, changing connections from heating mode to cooling mode or vice-versa and keeping the AC unit in satisfactory working condition after necessary servicing/ repair/ replacement of defective spares as required and refixing the same in existing position complete all specified and as directed by Engineer-in-Charge. Notes for Ser Item No 1 & 2 :- (i) Replacement of defective spares for making the AC units in satisfactory working condition will be measured & paid separately under relevant items and Labour charges for taking out old spares & refixing of new spares shall deemed to be included in unit quoted rate. (ii) Penalty will be charged for not attending complaint from 12 Hours to 24 hours Rs. 500/- each complaint. Further if complaint not attended and rectified within 24 hours after intimation (Intimation will be given by message/whats app/mail by mentioning time of complaint, for that contractor has to submit his authorised reps details for receiving complaint) of complaint, failing which same will be got rectified through spot quotation by job order by any other agency and double of the job order amount to be deducted from contractors dues.
Supply only Running capacitor 36+6 MFD. (Make:- Epcos/ Usha/ Keltron.)
Supply only Running capacitor 45+5 MFD. (Make:- Epcos/ Usha/ Keltron.)
Supply only Running capacitor 50+6 MFD. (Make:- Epcos/ Usha/ Keltron.)
Supply only Starting capacitor 80-100 MFD. (Make:- Epcos/ Usha/ Keltron.)
Supply only Starting capacitor 100-120 MFD. (Make:- Epcos/ Usha/ Keltron.)
Supply only Starting Relay 1622. (Make:- Hytech/ Renutrol/ Sri Ram/Microtech.)
Supply only Starting Relay 2000. (Make:- Hytech/ Renutrol/ Sri Ram/Microtech.)
Supply only Overload Relay. (Make:- Hytech/ Renutrol/ Sri Ram/Microtech.)
Supply only Thermostat switch 2059/2064/2054. ( Make :- Indfos/ Renutrol).
Supply only Condenser fan blade for Window type A.C of Capacity 1.5/2 TR made of Plastic. (Make:- As per Sample)
Supply only Condenser fan blade for spilt Type A.C of Capacity 1.5/2 TR made of Plastic. (Make:- As per Sample)
Supply only Wiring kit for Window/split type AC of Capacity 1.5/2 TR. (Make:- As per Sample)
Supply only remote control including battery for split AC Cap 1.5/2 TR of make as per site requirement and replace of old one complete all as directed by Engr-in-Charge. (Make- As per sample)
Supply only main printed circuit board (PCB) with electric accessories and sensors suitable for split/Tower AC of capacity 1.5/2/4 TR as directed by Engr-in-Charge.(Make:- As per Sample)
Supply only main printed circuit board (PCB) with electric accessories and sensors suitable for window AC of capacity 1.5/2 TR as directed by Engr-in-Charge. (Make:- As per Sample) Note for item Nos 3 to 17:- Materials of item Nos 3 to 17 to be incorporated in item Nos 1 & 2 here-in-before.
Supply & fixing in repairs plastic louvers (Front panel) for Window AC 1.5/2 TR complete all as directed by Engr-in-Charge. (Make:- As per Sample)
Supply & fixing in repairs of suction and discharge valve set of size 15mm (5/8''), 6mm (1/4'') and 12mm (1/2'') for Split AC 1.5/2 TR capacity complete all as directed by Engr-in-Charge. (Make:- LG/ Voltas/ Blue Star/ Hitachi). {Note:- (i) 15mm (5/8'') or 6mm (1/4'') and 12mm (1/2'') made one set (ii) Supply & filling of refrigerant gas shall be measured and paid under relevent item.}
Supply & fixing in repairs of capillary tube for Split/ Window type AC of capacity 1.5/2 TR complete all as directed by Engr-in-Charge. (Make:- As per Sample)
Supply & fixing in repairs of capillary filter for Split/ Window type AC of capacity 1.5/2 TR complete all as directed by Engr-in-Charge.(Make:- As per Sample)
Disconnecting the unserviceable PCB compatible from existing Window/ Split type AC of capacity 1.5/ 2/ 4TR and refixing after necessary repair for satisfactory functioning of the AC unit complete all as specified and directed by Engineer-in-charge.
Taking down unserviceable reversible valve for split/ window type AC of capacity 1.5TR and supply & fixing new reversible valve with solenoid coil including required copper pipe complete all as specified and directed by Engr-in-charge. (Make:- As per sample) (Note:- Supply & filling of refrigerant gas shall be measured and paid under relevent item.)
-ditto- all as per item No. 23 above but spilt/window type Air Conditioner of capacity 2 TR.
Disconnecting from mains and taking out existing unserviceable sealed compressor unit from the window type Air Conditioner of Cap 2 Ton, of any make any type from any location and Supply , Installing and testing of new sealed unit compressor alongwith test certificate from manufacturer including cleaning and removing dust/dirt from the cooling coil condenser coil with necessary modification capillary tube etc & Charging of Gas R-22/R-410a/R-32 and commissioning complete all as specified & directed by Engg-in-Charge. (Make:- Emerson /Tecumseh/ LG) Note :- Transportation Charges from site to trade workshop and back to original location after repair shall be deemed to be included in unit rate quoted above.
-ditto- all as per item No. 25 above but window type Air Conditioner of Capacity1.5 TR. (Make:- Emerson /Tecumseh/ LG)
-ditto- all as per item No. 25 above but spilt type Air Conditioner of Capacity 2 TR. (Make:- Emerson /Tecumseh/ LG)
-ditto- all as per item No. 25 above but spilt type Air Conditioner of Capacity 1.5 TR. (Make:- Emerson /Tecumseh/ LG)
Supply & fixing in repairs of Window A/C air blower motor copper wounded for 1.5 TR & 2 TR capacity AC complete all as specified & as directed. (Make-AUE/Crompton Greaves/Cool Master.)
Supply & fixing in repairs of Indoor Air blower motor for Split 1.5 TR & 2 TR capacity complete all as specified & as directed. (Make-AUE/Crompton Greaves/SPEED KING/Cool Master.)
Supply & fixing in repairs of copper wounded motor for Split type AC of 1.5 TR & 2 TR capacity complete all as specified & as directed. (Make-AUE/Crompton Greaves/Cool Master.)
Disconnecting the mains and taking out the unserviceable condenser coil of window type AC of capacity 1.5/ 2TR of any make from any location and supply, fixing and testing new condenser coil as per existing size & patterns for complete all as specified & as directed. (Make:- Voltas/Carrier/LG)
-ditto- all as per item No. 32 above but spilt type Air Conditioner Capacity 1.5/ 2 TR. (Make:- Voltas/Carrier/LG)
Supply & fixing in repairs of evaporator/cooling coil for window type Air Conditioner of capacity 1.5/ 2TR of existing make and size complete all as specified & as directed by Engr-in-Charge. (Make:- As per Sample)
-ditto- all as per item No. 34 above but spilt type Air Conditioner Capacity 1.5/ 2 TR.
Supply and fixing in repairs of 1.5TR capacity split type Air Conditioner outdoor kit including condenser coil, blower motor, chasis, base plate complete set except compressor complete all as specified & as directed by Engr-in-Charge. (Make:- Nepoleon/ Commander/Camipro/Skoda.)
-ditto- all as per item No. 36 above but spilt type Air Conditioner of capacity 2 TR. (Make:- Nepoleon/ Commander/Camipro/ Skoda.)
Taking down unserviceable indoor unit of split type AC of any make and supply & fixing new indoor unit complete set suitable for 1.5 TR capacity complete all as directed by Engr-in-Charge. (Make:- LG/Carrier/Voltas.)
-ditto- all as per item No. 38 above but spilt type Air Conditioner of capacity 2 TR. (Make:- LG/Carrier/Voltas.)
Supply & fixing heavy duty copper pipe 12mm (1/2") dia/ bore complete including insulation brazing, welding, nuts, bolts and screws of required size including taking down old unserviceable one complete all as specified and directed by Engr-in-Charge. (Make:- Malaysia/Cemipro or equivalent)
-ditto- all as per item No. 40 above but copper pipe 6mm (1/4") dia/ bore.
-ditto- all as per item No. 40 above but copper pipe 15mm (5/8") dia/ bore.
-ditto- all as per item No. 40 above but copper pipe 10mm (3/8") dia/ bore.
Taking down unserviceable insulation for copper pipe, supply and fixing new insulation for copper pipes suitabale for Split AC of capacity from 1.5 to 4.0 TR all as specified and directed by Engineer-in-charge.
Taking down unserviceable PVC drain pipe and supply & fixing new PVC drain pipe 15 mm dia for Split/window AC all as specified and directed by Engineer-in-charge. (Make:- Prayag/ Supreme/ Prince.)
Supply and filling refrigerant gas R-22/R-410a in window type /Split Type AC unit of capacity 1.5/2/3/4 TR including detecting the leakage of gas at any location and rectifying the defect to stop the leakage by gas welding or by any other means including cutting & brazing of copper tubes testing and commissioning complete in satisfactory working condition all as specified and as directed. (Make : Mefron/Floron/ Refron.)
Taking down unserviceable contactor and supply and fixing new contactor single phase suitable for Split AC 1.5 to 4.0 TR all as specified as directed by Engineer in-charge.(Make:- L & T/ Siemens/ ABB/ Legrand)
Dismantling and removing defective burnt blower unit motor of any capacity and make of 1.5/2 TR capacity window type AC and rewinding the motor with enamel copper winding wire of existing guage and size including replacement of worn out motor bearing etc, refixing and testing all as directed.
Dismantling and removing defective burnt blower unit motor of any capacity and make of indoor units of split/tower type AC of capacity 1.5/2/3/4 TR capacity rewinding the motor with enamel copper winding wire of existing guage and size including replacement of worn out motor bearing etc, refixing the same in existing position and testing complete all as specified and as directed.
Dismantling and removing defective burnt outdoor unit motor of any capacity and make of indoor units of split/tower type AC of capacity 1.5/2/4 TR capacity rewinding the motor with enamel copper winding wire of existing guage and size including replacement of worn out motor bearing etc, refixing the same in existing position and testing complete all as specified and as directed.
Dismantling the existing broken blower fan blade of the indoor units of the split type AC of Capacity 1.5/2 TR and supply and fixing in repairs new blower fan blade complete all as specified and directed.
Supply only 1.5 TR capacity window type AC kit including condenser coil, cooling coil, front grill blower motor, chasis, base plate complete set except compressor. Make:- Nepoleon/ Commander/ Speed.
Material and labour for sub main wiring with two runs of single core 6 Sqmm (nominal area) PVC insulated copper conductor FRLS (conforming to IS-694), multistranded, unsheathed 1100 volts grade in PVC casing capping (heavy grade) of suitable size with all fittings and casing caping accessories of surface type including one run 6 Sqmm single core unsheathed multistranded copper conductor cable FRLS (conforming to IS-694) as earth wire including taking down old unserviceable sub main wiring complete all as specified and as directed.
Material and labour for sub main wiring with two runs of single core 4 Sqmm (nominal area) PVC insulated copper conductor FRLS (conforming to IS-694), multistranded, unsheathed 1100 volts grade in PVC casing capping (heavy grade) of suitable size with all fittings and casing caping accessories of surface type including one run 4 Sqmm single core unsheathed multistranded copper conductor cable FRLS (conforming to IS-694) as earth wire including taking down old unserviceable sub main wiring complete all as specified and as directed. (Make of cable:- NICCO / FINOLEX / RR KABEL/ HAVELL'S/ POLYCAB / KEI INDUSTRIES LTD and make of Casing caping:- FINOLEX / PAYAL/KALINGA/ PRESTO PLAST.)} {Notes for item No.53 & 54 :-(i) Two runs of cable with one runs earth wire and PVC casing capping shall be measured as one unit length. (ii) Extra length of cable required for connection to DBs shall be deemed to be included in the unit quoted rate and shall not be measured separately. (iii) Earth wire shall run inside the casing capping. (iv) Suitable color code of wire must be ensure for phase/ neutral/ earth.}
Supply and fixing in repairs of metal clad socket outlet with single pole and neutral enclosure with two pin and earth plug socket complete with one single pole MCB 32 Amps including taking down old unservisible metal clad socket complete all as specified and as directed. (Make:- Schneider/ Legrand/ ABB/ Siemens/ L & T)
Supply and fixing in repairs of MCB SP 240 volts 6 to 32 Amps, 10 kA, 'C' curve complete all as specified and as directed. (Make:- Schneider/ Legrand/ ABB/ Siemens/ L & T)
Supply & fixing in repair metal clad socket of 20 Amps complete all as specified & as directed. (Make:- Schneider/ Legrand/ ABB/ Siemens/ L & T)
Supply & fixing in repairs metal clad plug with two pin of capacity 20 Amps complete all as specified & as directed. (Make:- Schneider/ Legrand/ ABB/ Siemens/ L & T)
Collecting of unserviceable voltage stabilizer of capacity 4 & 5 KVA from the MES store yard of AGE AC(OTBH) or dismantling the same from site and transporting to contractors workshop for locating the fault including checking the serviceability of electrical/electronic circuits relays and replacement of defective spare parts , reassembling after making connections, testing by applying low and high voltage input to get the 230 volts correct output and transporting back the same to MES store yard complete all as specified and directed by Engr-in-charge Note :- 1. Replacement of defective spares and rewinding of transformer of voltage stabilizer will be measured & paid separately under relevant items and Labour charges for taking out old spares & fixing of new spares shall deemed to be included in unit rate quoted.
Supply only Voltmeter (Analog) 0 to 300 volts any type shape single phase 50 Hz AC supply. (Make:- AE/ MIECO/ Rishabh)
Supply only Digital type Voltmeter 0 to 300 volts any type shape single phase 50 Hz AC supply, (Make:- AE/ MECO/ Rishabh)
Supply only Printer circuit control card suitable for 4 to 5 KVA.
Supply only Input/output switch (Make:- AE/Rishabh/Meco)
Supply only Push on switch (Make:- AE/Rishabh/Meco)
Supply only Indicator light complete with neon bulbs (Make:- AE/L & T/ C & S/ Renutrol/ Technomac)
Supply only Trigger Transformer for 4 & 5 KVA.
Supply only Relay for 3 to 5 KVA voltage stabilizer. Make:- Renutrol/ Technomac
Supply only Time delay and high/ low voltage cutoff circuit with relay suitable for 4KVA to 5 KVA. (Make:- Renutrol/ Technomac). Note for item no 60 to 68:- Material of item no 60 to 68 to be incorporated in item no 59 here-in-before
Taking out the burnt winding of transformer of voltage stabilizer and preparing core after cleaning by suitable cleaning agent and rewinding the transformer of voltage stabilizer with super enameld copper wire of existing gauge including varnishing, heating and refiting of capacity 3 KVA voltage stabilizer, complete all as specified & directed by Engr-in-Charge.
-ditto- all as per item No. 69 here-in-before but 4 KVA.
-ditto- all as per item No. 69 here-in-before but 5 KVA.
Disconnecting from mains and taking down for servicing of Water Cooler of Capacity 40/80, 60/120, Ltrs including cleaning of cooling coil, air filters , condenser, compressors, fan motor etc with vacuum cleaner or cleaning solution including checking the serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, fan and blower, etc., and keeping the Water cooler unit in satisfactory working condition after necessary servicing/ repair/ replacement of defective spares as required and installation in same location complete all as specified and as directed by Engineer-in-Charge. Note :- 1. Replacement of defective spares for making the water cooler units in satisfactory working condition will be measured & paid separately under relevant items and Transportation & labour charges for taking down old spares and fixing of new spares shall deemed to be included in unit rate quoted above.
Supply only over load protector relay suitable for 40/80 Ltrs capacity water coolers. (Make : Renutrol/Sri Ram/Microtech)
Supply only thermostat suitable for 40/80/120/150 Ltr capacity water coolers. (Make : Indfos/Renutrol)
Supply only condenser motor fan blade suitable for 40/80/120/150 Ltr capacity water coolers.
PVC flexible drain Hose Pipe 40 mm. (Make:- Prayag/ Polituff)
Waste water tray complete suitable for 40/80, 60/120, 150/150 Ltr capacity water coolers all as directed. ( Suitable for Voltas/Sidwal/Blue Star make water coolers).
Supply only chromium plated push taps suitable for 40/80/120/150 Ltr capacity water coolers all as directed. Make : Usha/Prayag/Cera/Essco.
Supply only PVC float valve of size 15mm dia complete suitable for 40/80/120/150 Ltr capacity water coolers including GI socket of same size all as directed.
Supply only Starting Capacitor 25 MFD. (Make :- Usha/Epcos/Keltron)
Supply only running Capacitor 10 MFD.(Make :- Usha/Epcos/Keltron)
Supply only Starting relay suitable for 40/80, 60/120, 150/150 Ltr. Make : Renutrol/Sri Ram/Microtech. Note for item No 73 to 82:- Material of item No 73 to 82 to be incorporated in item No 72 here-in-before.
Disconnecting the electric mains and taking out unserviceable condenser fan motor 1/16 HP from water cooler cap.60/120, 150/150 Ltr and supply and replace with new motor single phase AC 220 V of same capacity including reconnecting the electric connections and testing complete all as directed by Engr-in-Charge. (Make : AUE, Crompton Greaves / Cool Master)
All as per item No.83 above but 1/32 HP Water cooler of Capacity 40/80 Ltrs.
Dismantling and removing defective compressor and supply and fixing (in repairs) new sealed compressor of approved make obtained from authorised dealers submitting Warranty certificate & test certificates from manufacturer/authorised dealers including charging of refrigerent gas R-22/134A, commissioning and testing Water Coolers of 40/80 Ltrs capacity complete all as specified and directed. (Make :- Emerson /Tecumseh/LG.)
Dismantling and removing defective compressor and supply and fixing (in repairs) new sealed compressor of approved make obtained from authorised dealers submitting Warranty certificate & test certificates from manufacturer/authorised dealers including charging of refrigerent gas R-22/134A, commissioning and testing Water Coolers of 60/120 Ltrs capacity complete all as specified and directed. (Make :- Emerson /Tecumseh/LG.)
Dismantling and removing defective compressor and supply and fixing (in repairs) new sealed compressor of approved make obtained from authorised dealers submitting Warranty certificate & test certificates from manufacturer/authorised dealers including charging of refrigerent gas R-22/134A, commissioning and testing Water Coolers of 150/150 Ltrs capacity complete all as specified and directed. (Make :- Emerson /Tecumseh/LG.)
Disconnecting the mains and taking out the unserviceable condenser coil and S&F new condenser coil as per existing size & patterns for Water Coolers of capacity 60/120, 150/150 Ltrs complete all as specified & as directed.
Disconnecting the mains and taking out the unserviceable condenser coil and S&F new condenser coil as per existing size & patterns for Water/Coolers of capacity 40/80 Ltrs complete all as specified & as directed.
Dismantling the evaporator/cooling coil of water cooler capacity 150/150, 60/120 & 40/80 Ltrs, checking the leakages of gas and rectify the leakages by brazing or any other manner complete all as specified & as directed by Engr-in-Charge. (Make:- As per sample)
Taking down unserviceable PVC connection pipe and Supply and Fixing of PVC connections 15 mm dia bore with PTMT nuts of length 900 mm complete all as specified & as directed. (Make:- Prayag/ Polytuff)
Dismantling and removing defective compressor and supply and fixing (in repairs) new sealed compressor of approved make obtained from authorised dealers submitting Warranty certificate & test certificates from manufacturer/authorised dealers including charging of refrigerent gas R-22/134A, commissioning and testing refrigerators of 165 to 210 Ltrs capacity complete all as specified and directed. (Make :- Emerson /Tecumseh/LG.)
Dismantling and removing defective compressor and supply and fixing (in repairs) new sealed compressor of approved make obtained from authorised dealers submitting Warranty certificate & test certificates from manufacturer/authorised dealers including charging of refrigerent gas R-22/134A, commissioning and testing refrigerators of 280 to 310 Ltrs capacity complete all as specified and directed. (Make :- Emerson /Tecumseh/LG.) Note :- (i) The rates quoted by the contractor shall deemed to include the transportation cost from site of installation to contractor's repair workshop and back.
Disconnecting from mains and taking down for servicing of Refrigerator of Capacity 165/180/195/250/310 and 330 Ltrs including detecting the leakage of gas and refilling of refrigerant , cleaning of cooling coil, condenser, compressors, with vacuum cleaner or cleaning solution including checking the serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, etc., and keeping the Refrigerator unit in satisfactory working condition after necessary servicing/ repair/ replacement of defective spares as required complete all as specified and as directed by Engineer-in-Charge. Note :- 1. Replacement of defective spares for making the Refrigerator units in satisfactory working condition will be measured & paid separately under relevant items and Labour charges for taking out old spares and fixing of new spares shall deemed to be included in unit rate quoted.
Supply and filling refrigerant gas R-134a in Refrigerators/ Deep freezers/ Water coolers of any capacity, model and make including detecting the leakage of gas at any location and rectifying the defect to stop the leakage by gas welding or by any other means including cutting and brazing of copper tubes testing and commissioning complete in satisfactory working condition . (Make:- Mefron/ Floron/ Refron).
Supply and filling refrigerant gas R-32 in Window/ Split Type ACs of any capacity, model and make including detecting the leakage of gas at any location and rectifying the defect to stop the leakage by gas welding or by any other means including cutting and brazing of copper tubes testing and commissioning complete in satisfactory working condition . (Make:- Mefron/ Floron/ Refron).
Supply and fixing capillary tube of existing size including necessary brazing suitable for 165/300 ltrs capacity refrigerator all as specified and directed.
Supply only overload protector relay suitable for 165/300/310 ltrs capacity refrigerator all as directed. Make:- Renutrol/ Sri Ram/ Microtech
Supply only thermostat suitable for 165/300/310 ltrs capacity refrigerators all as directed. Make:- indfas
Supply only freezer door with spring of refregierators of any capacity all as directed.
Supply only vegetable basket with glass suitable for 165/300/310 ltrs capacity refrigerators all as directed.
Supply only PVC defrost tray as per sample suitable for 165/300/310 ltrs capacity refrigerators.
Supply only door gasket for refrigerators of capacity upto 250 Ltrs complete all as specified and directed.
Supply only door gasket for refrigerators of capacity more than 250 Ltrs but upto 310 ltrs complete all as specified and directed. Note for item No 97 to 104:- Material of item No 97 to 104 to be incorporated in item No 94 here-in-before.
Disconnecting from mains and taking down for servicing of Deep freezer of Capacity 165/180/195/310/330/450 and 500 Ltrs including detecting the leakage of gas and refilling of refrigerant , cleaning of cooling coil, condenser, compressors, with vacuum cleaner or cleaning solution including checking the serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, etc., and keeping the Refrigerator unit in satisfactory working condition after necessary servicing/ repair/ replacement of defective spares as required complete all as specified and as directed by Engineer-in-Charge. Note :- 1. Replacement of defective spares for making the Deep Freezer units in satisfactory working condition will be measured & paid separately under relevant items and Labour charges for taking out old spares and fixing of new spares shall deemed to be included in unit rate quoted.
Supply only starting relay 1/6 HP open with OLP all as specified and directed. Make :- Renutrol/Sri Ram/Microtech
Supply only starting relay for 1/8 HP open type with OLP all as specified and directed. (Make : Renutrol/Sri Ram/Microtech)
Supply only over load protector suitable for upto 500 Ltrs capacity deep freezer all as specified and directed. (Make : Renutrol/Sri Ram/Microtech)
Supply only running capacitor for upto 500 Ltrs capacity deep freezer all as specified. (Make : Epcos/Usha/ Keltron)
Supply only thermostat suitable for upto 500 Ltrs capacity deep freezer all as specified and directed. ( Make :- Indfos/ Renutrol).
Supply only starting capacitor for upto 500 Ltrs capacity deep freezer all as specified and directed. (Make : Epcos/Usha/ Keltron)
Supply only Axial Fan for deep freezers complete all as specified and directed. Note for item No 106 to 112:- Material of item No 106 to 112 to be incorporated in item No 105 here-in-before.
Taking down defective compressor of deep freezer of capacity Upto 300 Ltrs and any make and supplying and fixing new sealed unit compressor as specified here under including brazing and with necessary nuts and bolts, copper filter, capilary and supply & charging of refrigerant gas Non CFC based or equivalent to Non CFC gas in required qty and testing complete all as specified and directed by Engineer-in-Charge. (Make :- Emerson /Tecumseh/LG.)
All as per item No 113 above but of capacity above 300 Ltrs but upto 500 Litres deep freezer compressors. (Make :- Emerson /Tecumseh/LG.)
M&L for taking down desert cooler of any type/size/model from any height / floor for servicing like changing of wood wool pads, kit motor, submersible pump, fan blade, front grill, wiring, capacitor, cleaning or any other repair work as specified and re-fixing to existing place after repair work/overhauling complete all as specified and directed. Note :- (i) The rates quoted by the contractor shall deemed to include the cost of T&P. (ii) The items required to be replaced shall be measured and paid separately under relevant items.
Supply only wood wool pad of suitable size for 24” sweep desert cooler complete all as specified and directed 01 Set comprising of 3 Nos of pads approximate weight 800-900 Gms As per sample.
All as per item No 116 above but 20” sweep approximate weight 700 -800 Gms. As per sample.
Supply only submersible pump motor 230 Volts, single phase, AC suitable for Plastic body/Steel body Desert cooler complete all as specified & as directed. (Make- Bajaj/ Crompton Greaves/ Khaitan.)
Supply only front grill for desert cooler of approved make suitable for fixing 5 Amp switch, three speed regulator and indicating lamp all as specified and directed.
Supply only running capacitor of 4 MFD capacity for water cooler complete all as directed. (Make- USHA/EPCOS/KELTRON)
supply only running capacitor of 6 MFD capacity for water cooler complete all as directed. (Make- USHA/EPCOS/KELTRON)
Supply only wire mesh for desert cooler pad (Set of Three) including taking down old one.
Supply only PVC pipe for connecting pump and water distributor of size 15 mm dia including PVC elbows all as directed. (Make:- Prayag/ Supreme/ Prince).
Supply only PVC elbow for desert cooler of suitable size complete all as specified & as directed.
Supply only PVC 4 Way distribution cross for desert cooler complete all as specified & as directed. Note for item No 116 to 125:- Material of item No 116 to 125 to be incorporated in item No 115 here-in-before.
Supply and fixing in repairs of desert cooler kit fan motor, single speed, 230 V, 50 Hz of capacity 90 Watt 1450 RPM, copper wounded including nuts bolts for fixing complete all as specified and directed. (Make : Crompton Greaves/Usha/Khaitan)
Supply and fixing Desert cooler exhaust fan motor, single speed, 230 V, 50 Hz of capacity 150 Watt 1400 RPM, copper wounded including nuts bolts for fixing including taking down old unserviceable one complete all as specified and directed. (Make : Havells/Crompton Greaves/Almonard)
S&F in repairs flexible copper conductor cable, 3 core PVC insulated & PVC sheathed of size 1.5sqmm complete all as specified and directed. ( Make -Polycab/Kalinga Premium/Plaza).
Supply only desert coolers fan blade of 18" (inch) sweep made out of Aluminium complete all as specified.
Supply only desert coolers fan blade of 20" (inch) sweep made out of Aluminium complete all as specified.
Supply only side panel of desert cooler of 20" (inch) sweep made out of 20 SWG, GI sheet suitable for fixing with the existing desert coolers, duly painted with synthetic enameled paint over a coat of red oxide primer complete all as specified and directed.
Supply only switch piano flush type single pole one way 5Amp 230 V for desert cooler all as directed. (Make-Anchor/Kinjal/Havells)
Supply only 3 pin plug top 15 Amp for desert cooler complete all as specified and directed. (Make-Anchor/Kinjal/Havells)
All as per item No. 133 above but 5 Amps. (Make-Anchor/Kinjal/Havells) Note for item No 129 to 134:- Material of item No 129 to 134 to be incorporated in item No 115 here-in-before.
Supply and fixing in repairs cooler fan motor bracket sets made up as existing including painting complete all as specified and directed.
Preparation for old painted surface of desert cooler of any capacity and any make on inner surface & outer surface. Repainting the complete desert coolers ie side panel, bracket, body & desert cooler stand with two coats of synthetic enameled paint (1st grade quality) including two coats of black water proof paint on reserve water tank & marking with “ GE(U) P&M (MES)” letter size of 50mm height at stencil in black/white including servicing and greasing of fan motor/pump and replacement of PVC pipe worn out nut, bolts and washers complete all as per site requirement. (Make of paint and primer:- ASIAN/ BERGER/ JHONSON & NICHOLSON/ SHALIMAR.)
S&F in repairs desert cooler body of size 25 inch x 25 inch x 36 inch (height) with side panels (03 Nos) fabricated out of 20 SWG PGI Sheet alongwith PVC front grill, distribution switch, 5 Amp piano switch and tank of depth 11 inch. Painting the complete desert cooler i.e, side panel, bracket body with two coat of synthetic enamel paint (Ist grade quality) over a coat of red oxide zinc chrome primer and two coat of black water proof paint on reserve tank and marking with "GE (U) P&M (MES)" letter size of 50mm height in stencil in black/white all as specified and directed by Engr-in-Charge. (Make of paint and primer:- ASIAN/ BERGER/ JHONSON & NICHOLSON/ SHALIMAR.)
Supply and fixing in repairs new PCB for indoor/ outdoor units suitable for LG (Dual Inverter)/ Hitachi/ Voltas/ panasonic make inverter ACs of capacity 2.5/ 2.0TR complete all as specified and directed.
M&L for disconnecting the unserviceable PCBs from indoor/ outdoor units of existing LG (Dual Inverter)/ Hitachi/ Voltas/ panasonic make inverter ACs of capacity 2.5/ 2.0TR and re-fixing the same after necessary repairs for satisfactory functioning of AC unit complete all as specified and directed.
Supply and fixing in repairs of DC condensor fan motor of out door unit suitable for LG (Dual Inverter)/ Hitachi/ Voltas/ panasonic make inverter ACs of capacity 2.5/ 2.0TR complete all as specified and directed.
Supply and fixing in repairs of DC blower fan motor of indoor unit suitable for LG (Dual Inverter)/ Hitachi/ Voltas/ panasonic make inverter ACs of capacity 2.5/ 2.0TR complete all as specified and directed.
RUCHIKA ENGG.WORKS
SNOWY ENGINEERING INC
P S TRADERS
Flint India
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .