Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.6 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹20.4 L+₹4.0 L (24.3%)Rejected-Finance HOUSE NO 102 LANE NO 4 C ANAND NAGAR BOHRI JAMMU 180002 J K | JAMMU | JAMMU AND KASHMIR | 180002 | L2 | Rejected-Finance Rejected being other than L1 | |
| 3 | L3₹20.8 L+₹4.3 L (26.3%)Rejected-Finance | L3 | Rejected-Finance Rejected being other than L1 | |
| 4 | L4₹24.9 L+₹8.4 L (51.2%)Rejected-Finance H NO 1346 SECTOR 13 P HISAR 125005 HARYANA | HISAR | HISAR | HARYANA | 125005 | L4 | Rejected-Finance Rejected being other than L1 | |
| 5 | L5₹36.2 L+₹19.8 L (120.2%)Rejected-Finance 403 GH MANSADEVI COMPLEX PANCHKULA 134109 HARYANA | PANCHKULA | HARYANA | 134109 | L5 | Rejected-Finance Rejected being other than L1 |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
8 Jun 2021, 6:00 pmClosed
GE 865 EWS
GE 865 EWS, PIN-913 865 C/o 56 APO
REPAIR MAINT AND FILTRATION OF INSULATING OIL OF TRANSFORMERS SERVO STABILIZER AND ALLIED WORKS UNDER GE 865 EWS
2021_MES_441893_1
865/EWS(NIT-20)/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE 865 EWS
As per tender documents and as per policy in vogue
9 documents required · 9 mandatory
₹500
GE 865 EWS
₹90,000
Yes
20 Jun 2021
10 May 2021
10 Jun 2021
10 May 2021
8 Jun 2021
25 May 2021
Amount
Taking down water heater storage type capacity 25 Ltr of any make Vertical / horizontal type after disconnecting the electric/ water connections and dismantling the heating elements /geyser assy and descaling complete with de scaling solutions and replacement of gaskets suitable for resisting 98 degree temp /nut bolts etc all as directed and testing the safety devices and reinstalling at same location complete all as specified and directed by Engr-in-Charge.
Taking down water heater storage type capacity 50 Ltr of any make Vertical / horizontal type after disconnecting the electric/ water connections and dismantling the heating elements /geyser assy and descaling complete with de scaling solutions and replacement of gaskets suitable for resisting 98 degree temp /nut bolts etc all as directed and testing the safety devices and reinstalling at same location complete all as specified and directed by Engr-in-Charge.
S &F in replacement of water inlet/outlet copper assy suitable for storage water heater of 25/50 Ltrs capacity having provn of housing thermostate, heating element including providing rubber gaskets and holding nut bolts etc complete all as specified and directed by Engr-in-Charge. Make : As per manufacturer recommendation of Havells/Racold/ CG/Bajaj/Venus/Supreme/Usha Lexus/Jaquar/V Guard/Pearl/ Orison
S &F in replacement of thermostate switch for water storage heater suitable for any type 220/240V 50HzAC temperature range 32 - 88 degree centigde ISI marked complete all as specified and directed by Engr-in-Charge. Make : As per manufacturer recommendation of Havells/Racold/ CG/Bajaj/Venus/Supreme/Usha Lexus/Jaquar/V Guard/Pearl/ Orison
S&F in replacement of Heating elements suitable for water storage heater vertical type of any make 220/240 V AC 1500W and making connections and testing complete all as specified and directed by Engr-in-Charge. Make : As per manufacturer recommendation of Havells/Racold/ CG/Bajaj/Venus/Supreme/Usha Lexus/Jaquar/V Guard/Pearl/ Orison
S&F in replacement of heating elements suitable for water storage heater vertical type of any make 220/240 V AC 2000W and making connections and testing complete all as specified and directed by Engr-in-Charge. Make : As per manufacturer recommendation of Havells/Racold/ CG/Bajaj/Venus/Supreme/Usha Lexus/Jaquar/V Guard/Pearl/ Orison
S&F in replacement of heavy duty PVC connections armored type with brass union ,nut, heat resistance type rubber washer for hot water complete all as specified and directed by Engr-in-Charge. Make : Prayag/Polytuf/Supreme/SFMC/Jindal/AKG
S&F in replacement of PVC connections with brass union ,nut, rubber washer for cold water complete all as specified and directed by Engr-in-Charge. Make : Prayag/Polytuf/Supreme/SFMC/Jindal/AKG
S&F in replacement of indicating lamps suitable for storage water heater any type & cap complete all as specified and directed by Engr-in-Charge.
S&F in replacement of PVC insulated and sheathed flexible cable 3 core with copper conductor of size 40/0.0076 all as specified and directed by Engr-in-Charge. Make : L&T/FINOLEX/GRANDPLAY/ANCHOR/POLYCAB
S&F in replacement of GI tubing 15 mm bore medium gde for geyser vent /water connections with required fittings complete fixed to wall /ceilings including making good the disturbed surfaces all as directed. Make : Jindal/TATA/Prakash Surya/BST
S&F in replacement of GI tubing 20 mm bore medium grade for geyser vent /water connections with required fittings complete fixed to wall /ceilings including making good the disturbed surfaces all as directed. Make : Jindal/TATA/Prakash Surya/BST
S&F Stop valve brass CP of size 15 mm dia heavy duty complete all as specified and directed by Engr-in-Charge. MAKE: PARKO/MARC/ESS ESS/CERA
S&F Angle valve brass CP of size 15 mm dia heavy duty complete all as specified and directed by Engr-in-Charge. MAKE: PARKO/MARC/ESS ESS/CERA
S&F Plug Top 15 Amps suitable for working on 230 volts 50 Hz AC supply complete all as specified and directed by Engr-in-Charge. Make : Anchor/Legrand/Crabtree/Cona/C&S
S&F switch socket combination 2 in 1, 3 Pin 5 and 15 Amp flush type universal complete all as specified and directed by Engr-in-Charge. Make : Anchor/Legrand/Crabtree/Cona/C&S
S& replacement of old unsv gang box 2 in 1, 3 pin 5 and 15 Amp flush type universal universal complete all as specified and directedby Engr-in-Charge.
S&F copper tank of 25 ltr capacity geyser as per sample complete all as specified and directed by Engr-in-Charge. Make : As per manufacturer recommendation of Havells/Racold/ CG/Bajaj/Venus/Supreme/Usha Lexus/Jaquar/V Guard/Pearl/ Orison
S&F copper tank of 50 ltr capacity geyser as per sample complete all as specified and directed by Engr-in-Charge. Make : As per manufacturer recommendation of Havells/Racold/ CG/Bajaj/Venus/Supreme/Usha Lexus/Jaquar/V Guard/Pearl/ Orison
Supply & fix new compressor 1/8 HP suitable for refrigerator of capacity 165 to 200 Ltr in replacement of burnt defective compressor. The work includes taking out the defective compressor and testing on completion complete all as specified and directed by Engr-in-Charge. Make : Techumesh/LG/Whirlpool/Samsung/Lloyd/Godrej Note:- Charging of gas R-134a is deemed to be includded in overall rates qutoed against this item.
All as per item No 20 above but 1/6 HP but refrigerator capacity 220 to 320 Ltrs complete all as specified and directed by Engr-in-Charge. Make : Techumesh/LG/Whirlpool/Samsung/Lloyd/Godrej Note:- Charging of gas R-134a is deemed to be includded in overall rates qutoed against this item.
S/F in replacement of evaporator cooling coil of refrigerator 165 to 200 ltrs capacity complete all as specified and directed by Engr-in-Charge. Make : As per manufacturer recommendation of LG/Whirlpool/ Samsung/ Lloyd/Godrej
S/F in replacement of evaporator cooling coil of refrigerator 220 to 320 ltrs capacity complete all as specified and directed by Engr-in-Charge. Make : As per manufacturer recommendation of LG/Whirlpool/ Samsung/ Lloyd/Godrej
S&F in replacement of relay box type/open type suitable for 1/6 to 1/8 HP refrigerator of any make & size complete all as specified and directed by Engr-in-Charge. Make : As per manufacturer recommendation of LG/Whirlpool/ Samsung/ Lloyd/Godrej
S/F in replacement of overload protector suitable for refrigerator of any make & size complete all as specified and as directed by Engr-in-Charge. Make : As per manufacturer recommendation of LG/Whirlpool/ Samsung/ Lloyd/Godrej
Taking out burnt defective compressor 1/3 HP from deep freezer of cap 420/425 ltr & S/F new compressor 1/3 HP capacity suitable for deep freezers 425 ltrs capacity of any make including dehydrating of system and charging of comp oil & refrigerant gas complete all as specified and directed by Engr-in-Charge. Make : As per manufacturer recommendation of LG/Samsung/ Lloyd/Blue Star/Voltas/Godrej/Haier
S&F in replacement of thermostatic switch for refrigerator of any make and 165 to 320 Ltrs Capacity complete all as specified and directed by Engr-in-Charge. Make : As per manufacturer recommendation of LG/Whirlpool/ Samsung/ Lloyd/Godrej
Supply and fix in replacment door gasket suitable for refrigerator of capacity 165/200 ltrs single door complete all as specified and directed by Engr-in-Charge. Make : As per manufacturer recommendation of LG/Whirlpool/ Samsung/ Lloyd/Godrej
Supply and fix in replacment door gasket suitable for refrigerator of capacity 286/300 ltrs single door /double door complete all as specified and directed by Engr-in-Charge. Make : As per manufacturer recommendation of LG/Whirlpool/ Samsung/ Lloyd/Godrej
Supply and charging the refrigerant gas R-134a in refrigerators of capacity 165 to 200 litrs including testing complete all as specified and directed by Engr-in-Charge. Make : As per manufacturer recommendation of LG/Whirlpool/ Samsung/ Lloyd/Godrej
Supply and charging the refrigerant gas R-134a in refrigerators of capacity 200 to 320 litrs including testing complete all as specified and directed by Engr-in-Charge. Make : As per manufacturer recommendation of LG/Whirlpool/ Samsung/ Lloyd/Godrej
Supply and charging the refrigerant gas R-134a in deepfreezers of capacity 200 to 425 litrs including testing complete all as specified and directed by Engr-in-Charge. Make : As per manufacturer recommendation of LG/Samsung/ Lloyd/Blue Star/Voltas/Godrej/Haier
M&L for Servicing of split type AC 1.5/2 TR capacity including oiling greasing of fan motor replacement of synthetic filter & checking of electric circuit for smooth functioning of AC (S&F of unserviceable burnt spare parts of machine shall be measured and paid for separately under respective items) complete all as specified and directed by Engr-in-Charge.
S&F in replacement of capacitor 45+6 mfd suitable for 1.5 capacity AC complete all as specified and directed by Engr-in-Charge. Make : As per manufacturer recommendation of LG/Samsung/ Lloyd/Blue Star/Voltas/Godrej/Haier/Daikin/Hitachi
All as per above Item No 34 but 50+6 Mfd suitable for 2.0 Ton capacity complete all as specified and directed by Engr-in-Charge. Make : As per manufacturer recommendation of LG/Samsung/ Lloyd/Blue Star/Voltas/Godrej/Haier/Daikin/Hitachi
S&F in replacement of wiring kit suitable for 1.5/2 ton capacity split AC complete all as directed by Engr-in-Charge Make : As per manufacturer recommendation of LG/Samsung/ Lloyd/Blue Star/Voltas/Godrej/Haier/Daikin/Hitachi
S&F in replacement of metal clad socket 20 Amp complete all as specified and directed by Engr-in-Charge. Make : Anchor/C&S/Cona/Havells/Legrand/L&T/Crabtree
S&F in replacement of Metal clad plug complete all as specified and directed by Engr-in-Charge. Make : Anchor/C&S/Cona/Havells/Legrand/L&T/Crabtree
Taking out unserviceable fan/blower motor and M&L for rewinding and repairing of fan motor of split type AC 1.5/2.0 TR capacity with supper enameled copper winding wire of existing gauge complete all as specified and directed by Engr-in-Charge.
S&F New rotary type compressor suitable for split type AC of capacity 1.5 TR in replacement to unserviceable compressor of any Make complete all as specified and directed by Engr-in-Charge. Note : Charging of gas R-134a is deemed to be includded in overall rates qutoed against this item.
All as per above item No 40 but capacity 2.0 TR Note : Charging of gas R-134a is deemed to be includded in overall rates qutoed against this item.
S&F New Fan blade for 1.5/2 TR Split AC in replacement of old underviceable fan blade complete all as specified and directed by Engr-in-Charge. Make : As per manufacturer recommendation of LG/Samsung/ Lloyd/Blue Star/Voltas/Godrej/Haier/Daikin/Hitachi
S&F New blower for 1.5/2 TR split AC in replacement of old underviceable blower complete all as specified and directed by Engr-in-Charge. Make : As per manufacturer recommendation of LG/Samsung/ Lloyd/Blue Star/Voltas/Godrej/Haier/Daikin/Hitachi
Supply & charging the refrigerant gas R-134a to window/ split type AC upto 2 Ton capacity including testing complete all as specified and directed by Engr - in-Charge. Make : As per manufacturer recommendation of LG/Samsung/ Lloyd/Blue Star/Voltas/Godrej/Haier/Daikin/Hitachi
S&F in replacement of MCB 20 to 32 Amps Cap 230 volt AC supply complete all as specified and directed by Engr-in-Charge. Make : Legrand/L&T/Schneider/ABB/C&S
S&F in replacement of MCB SPN 40 Amps Cap 230 volt AC supply complete all as specified and directed by Engr-in-Charge. Make : Legrand/L&T/Schneider/ABB/C&S
S&F in replacement of MCB SPN 63 Amps Cap 230 volt AC supply complete all as specified and directed by Engr-in-Charge. Make : Legrand/L&T/Schneider/ABB/C&S
Supply and fix sheet metal single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 amps complete all as specified and directed by Engr-in-Charge. Make : Legrand/L&T/Schneider/ABB/C&S
S&F condensor with copper tubing and aluminium fins suitable for 1.5/2.0 TR split AC in replacement of old underviceable condenser complete all as specified and directed by Engr-in-Charge. Make : As per manufacturer recommendation of LG/Samsung/ Lloyd/Blue Star/Voltas/Godrej/Haier/Daikin/Hitachi
Supply and fix in replacement new PCB card suitable for 1.5/2TR capacity of split AC's complete all as specified and directed by Engr-in-Charge. Make : As per manufacturer recommendation of LG/Samsung/ Lloyd/Blue Star/Voltas/Godrej/Haier/Daikin/Hitachi
Supply and fix in repalcement new swing motor suitable for 1.5/2 TR capacity of window/split AC complete all as specified and directed by Engr-in-Charge. Make : As per manufacturer recommendation of LG/Samsung/ Lloyd/Blue Star/Voltas/Godrej/Haier/Daikin/Hitachi
Supply and fix in repalcement of PVC drain pipe 15 mm dia with fittings and fixing accessories complete all as specified and directed by Engr-in-Charge. Make : Supreme/SFMC/AKG/Kisan/Jindal
Labour only to convert split AC 1.5/2.0 TR from cooling mode to heating mode by heating element/ reverse solenoid valve arrangement wiring interlocking as required complete all as specified and as directed by Engineer-in-charge.
S&F reverse valve suitable for split type AC 1.5/2.0 TR incuding additional copper tubing of any size brazing work, pressure testing, dehydration gas charging upto required level and necessary modification in remote control unit for satisfactory function of unit in heating mode complete all as specified and directed by Engineer in charge. Make : As per manufacturer recommendation of LG/Samsung/ Lloyd/Blue Star/Voltas/Godrej/Haier/Daikin/Hitachi
Supply and replacement electric cable PVC insulated rubber sheathed circular multistranded copper conductor of size 2.5 Sqmm 3 Core complete all as specified and directed by Engr-in-Charge. Make : Polycab/Havells/Anchor/Finolex/L&T/GRANDPLAY
Rewinding of burnt windings of Exhaust fans of size 400-450 mm size including dismantling from loc and removing the burnt out winding , cleaning the stator with CTC solution to remove the burnt slots. Rewinding the same with new super enamelled copper wire same gauge and size /number of turns , varnishing the winding completely and reassembling complete all as specified and directed by Engr-in-Charge. (Spare parts replaced will be measured &paid seperately)
Al as per above item No 56 above but exhaust fan of size up to 300 mm sweep complete all as specified and directed by Engr-in-Charge.
M&L replacement of louvers made out of metal sheets suitable for up to 450 mm sweep exhaust fans complete all as specified and directed by Engr-in-Charge.
supply and fix flexible twin twisted copper wire two core of size 23/0.0076mm upto 1.5 mtr length complete all as specified and directed by Engr-in-Charge. Make : Polycab/Havells/Anchor/Finolex/L&T/GRANDPLAY
Supply and fix Ball bearing suitable for Exhaust fan 400mm - 450mm sweep any make complete all as specified and directed by Engr-in-Charge.
Supply and fix Ball bearing suitable for Exhaust fan up to 300 mm sweep any make complete all as specified and directed by Engr-in-Charge.
Supply and fix Condensor 2.5 MFD 230 V suitable for Exhaust fan of any sweep/size complete all as specified and directed by Engr-in-Charge.
Supply and fix Condensor 4.0 MFD 230 V suitable for Exhaust fan of any sweep/size complete all as specified and directed by Engr-in-Charge.
Supply and fix Gun metal Bushings suitable for Exhaust fan fan up to 300 mm sweep any make complete all as specified and directed by Engr-in-Charge.
Supply and fix Gun metal Bushings suitable for Exhaust fan up to 450mm mm sweep any make complete all as specified and directed by Engr-in-Charge.
Disconnecting and removing HT/LT Cables and other connections and Strip opening of transformer 400 to 500 KVA, 11 KV/433 volts indoor/outdoor type of any make after unsecrewing nuts/bolts screws and connected accessories such as breather, conservator tank, temperature gauge for replacement of defective HT/LT coils,replacement of drain valve,paper insulation strip, breather etc and other defective parts (payment of defective replaced parts shall be measured and paid seperately. Re-assembling after replacing the defective coils parts and replacing the top gasket sheet and other insulating, packing materials and testing complete all as specified and directed by Engr-in-Charge. Note :- The reassembling element covers the assembling of parts not to be changed where as for the rest it shall be the part of the item being replaced.
All as per Srl item No. 66 above but of capacity 200 to 320 KVA.
All as per Srl item No. 66 above but of capacity upto 50 KVA to 160 KVA.
Supply and replacement of HT coils made out of super enamelled HT copper winding wire of transformers suitable to existing gauge and capacity from 63 KVA to 500 KVA all as specified and as directed. Note :- The coil to be replaced shall have same number of truns gauge insulation value matching with manufactures design complete all as specified and directed by Engr-in-Charge.
Supply and replacement HT 11 KV bush suitable for indoor/ outdoor type upto 500 KVA transformers complete with brass stud, 04 Nos brass nuts, brass cup and packing gasket complete all as specified and as directed by Engr-in-Charge. Make : ATLAS / JAIPURIA
All as per Srl item No. 70 above but of capacity 200 to 320 KVA.
All as per Srl item No. 70 above but of capacity upto 50 KVA to 160 KVA.
Supply and replacement brass stud for LT side suitable for Tfrs 400 KVA to 500 KVA complete all as specified and as directed by Engr-in-Charge.
All as per Srl item No.73 above but of capacity 200 to 320 KVA complete all as specified and as directed by Engr-in-Charge.
All as per Srl item No. 73 above but of capacity upto 50 KVA to 160 KVA complete all as specified and as directed by Engr-in-Charge.
Supply and replacement temperature guage 0-1000 degree celsius range dial type complete all as specified and as directed by Engr-in-Charge.
Supply and replacement Insulator and Cup insulator for bush of LT Side suitable for transformers upto 500 KVA complete all as specified and as directed by Engr-in-Charge.
Supply and replacement Insulator and Cup insulator for bush of HT Side suitable for transformers upto 500 KVA complete all as specified and as directed by Engr-in-Charge.
M & L for repair to tapping switch including replacement of copper contact,bakelite plate and operating rod of capacity 400 KVA to 500 KVA Transformer complete all as specified and as directed by Engr-in-Charge.
All as per Srl item No. 79 above but of capacity 200 to 320 KVA Complete all as specified and as directed by Engr-in-Charge.
All as per Srl item No. 79 above but of capacity upto 50 KVA to 160 KVA Complete all as specified and as directed by Engr-in-Charge.
Dehydration and filteration of transformer oil to achieve die-electric strength of 50 KV at 2.5 mm gap and refilling the same after achieving the desired dilectric strength Complete all as specified and as directed by Engr-in-Charge.
Supply and fill up transformer oil as in topping up/ refilling of transformer having dielectric strength not less than 55 KV at 2.5 mm gap conforming to IS Complete all as specified and as directed by Engr-in-Charge. Make : Savita/Power Oil/Trans Oil
Complete removal of existing paint from the transformer of capacity 400 KVA to 500 KVA by scratching/rubbing, cleaning and preparation of surface repainting the transformer by applying two coats of synthetic enameled paint of approved quality of colour over a coat of red oxide primer complete all as specified and as directed.
All as per Srl item No. 84 above but of capacity 200 to 320 KVA.
All as per Srl item No. 84 above but of capacity upto 50 KVA to 160 KVA.
Supply and replace transformer breather complete with silca gel for capacity upto 400 KVA -500 KVA transformer complete all as specified and as directed by Engr-in-Charge.
All as per Srl item No. 87 above but of capacity 200 to 320 KVA.
All as per Srl item No. 87 above but of capacity upto 50 KVA to 160 KVA.
Reconditioning of LT coils of aluminium/copper wound transformer by replacing the old paper tape insulation. Necessary packing / paper insulation, strengthening the entire LT strip coils as per manufacturers design complete all as specified and directed of transformer upto 400 KVA- 500 KVA capacity all as specified and as directed.
All as per Srl item No. 90 above but of capacity 200 to 320 KVA.
All as per Srl item No. 90 above but of capacity upto 50 KVA to 160 KVA.
Supply and fixing Silica Gel(having blue colour)to be filled in transformer breather Complete all as specified and directed by Engr-in-Charge.
Supply and fix Copper Thimble of size 120/150/185/240/300/400 Sq mm complete all as specified and as directed by Engr-in-Charge.
Supply and fix Aluminium Thimble of size 10/16/35/50/70/95 Sq mm complete all as specified and as directed by Engr-in-Charge.
Supply and fix Aluminium Thimble of size 120/150/185/240/300/400 Sq mm complete all as specified and as directed by Engr-in-Charge.
Supply & fix of tubes light grade of size 80 mm bore galvanised with all fittings and fixed complete to walls and ceiling or laid in floors complete all as specified. Make : TATA/JINDAL/Prakash Surya/BST
supply & replacement of cable end termination kit heat shrinkable indoor type suitable for XLPE HT 11000 volts cable of size 95 Sqmm 3 core fixed in replacement complete all as specified and directed by Engr-in-Charge. Make : M-seal/Denson /3M/Raychem
Supply & replacement of cable end termination kit heat shrinkable outdoor type suitable for XLPE HT 11000 volts cable of size 95 Sqmm 3 core fixed in replacement complete all as specified and directed by Engr-in-Charge. Make : M-seal/Denson /3M/Raychem
Supply & replacement of air break switch gang operated (GOD) triple pole with drop out fuses mechanically operated, mounted on insulators 15 Nos & steel frame with operating mechanism & operating rod of GI pipe 25mm & medium grade with necessary clamps to be operated from ground level 11 KV grade working pressures and current upto 200 Amps complete all as specified and directed by Engr-in-Charge. Make : M-seal/Denson /3M/Raychem/BHEL/Jaipuria/Jayshree/ Universal
Disconnecting and removing LT Cables and other connections and Strip opening of Servo stabilizers of up to 100 KVA, 433 volts indoor/outdoor type of any make after unsecrewing nuts/bolts screws and connected accessories such as breather,temperature gauge for replacement of defective LT coils,replacement of drain valve, paper insulation strip, electronic cards of each phase (RYB) etc and other defective parts i.e. servo motor, Out /In terminals. (payment of defective replaced parts shall be measured and paid seperately. Re-assembling after replacing the defective coils parts and replacing the top gasket sheet and other insulating, packing materials and testing complete all as specified and directed. Note :- The reassembling element covers the assembling of parts not to be changed where as for the rest it shall be the part of the item being replaced.
M & L for replacement of servo motor of existing model and capacity incl testing and commissioning after repair complete all as specified and directed.
M & L for replacement of servo electronic card of existing model and size incl testing and commissioning after repair complete all as specified and directed.
Note :- Makes of spare parts to be replaced under this work and mentioend in relevant items in this BOQ here-in-before shall be of approved make and as per the manufacturer's recommendation of Geysers/Refrigerator/Deepfreezer/AC/Trasnformers and other equipments.
SUMEET TRADING CORPORATION
darshan kumar gandhi
Horizon Construction Company
EESSI
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .