Executive Engineer Elect. PWD EMD M-251
O/o EE (E), PWD NES/ M-251, LM Bund Road, Ramesh Park, Delhi-92
RMO Electrical and Mechanical Services at SDM Court Seelampur Delhi. Sub Head- Repairing of Split Type AC and E.I Work in Tin Shed and Toilet.
2021_PWD_201334_1
DB-5/PWD NES ED/M-251/2021/377
Open Tender
Electrical Works
Item Rate
10 days
SDM office Seelam Pur
Please refer Tender documents.
6 documents required · 6 mandatory
₹0
₹10,000
8 Apr 2021
10 Mar 2021
15 Mar 2021
10 Mar 2021
15 Mar 2021
10 Mar 2021
Amount
Dismantling of existing outdoor unit of 1.5/2.0 TR Split Type air conditioners, disconnection of refrigerant pipes and power cable i/c installation of outdoor unit at other location charging of refrigerant connections testing and commissioning etc as required.
Supplying and Charging of R-22/R-410 refrigerant gas in the existing WTAC/STAC/Water Cooler of all sizes i/c necessary copper pipe, capillary, filter, pressure testing and flushing the complete system and gas charging complete as required.
Providing and fixing the copper pipe of 5/8” & 3/8, 3core copper cable including insulation of refrigerant pipe with the1/2” thick nylon insulation pipe covered with2:dia PVC flexible pipe including drain pipe etc complete as reqd
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. " Group C"
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 Way Double door
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
Single pole and neutral
Supplying and Fixing 300 mm dia 900 RPM heavy duty exhaust fan PVC type suitable for operation on 230 volt, ±10%, 50 Hz supply to fixed on wall i/c connection with 1.5 Sq.mm PVC insulated PCV sheathed copper conductor single core cable i/c testing etc as reqd.
Supplying, Installation, Testing and Commissioning on wall/ceiling of 18 to 20 Watt 1200 mm long high efficiency LED liner batten luminaries having extruded aluminium housing and HET diffuser with in built APFC driver having efficiency of driver 85% power factor >0.95, THD <10% with minimum 2.5 KV surge protection etc suitable for operation on 150 to 265 V single phase AC supply, having system efficacy 100 luman per watt and colour temperature of 5500 to 6500 K, CRI>80 including connection with 1.5 Sq.mm PVC insulated copper conductor FRLS cable with the help of two Clamp sleeve complete etc as reqd.
Supplying and fixing of 40 Watt downlighter IP 66 protection suitable for pendant mount application pressure dia cast aluminium alloy housing with corrosing resistance powder coating for operation 220 Volt 50 Hz single phase AC supply having luman efficacy minimum 80 luman per watt i/c hanging arrangement connection, testing etc complete as reqd.
Supplying, Installation, testing and commissioning of 200 watt LED flood light fitting. Made out of pressure dia cast aluminium housing with toughened glass, manufacturer's logo embossed on the housing (printing/stickers not allowed) and with separate compartment of lens and driver to make it IP-66 degree of protection, minimum lumen 25000 lumen LEDs must have lense plates for better throw across and along the road with luminaire efficacy of greater than 120 Lumen/Watt, L70-50000 burning hours colour rendering (CRI) of ≥ 70 and co-related colour temperature (CCT) of 5700K (±300K). The luminary should have 10 KV surge protection, PF≥0.95, and total harmonic distortion of THD≤ 10%, operatable in voltage range of 150-280V. The driver used must be a constant current driver with efficiency of ≥85% and driving current ≤ 700 mA. .The manufacturer should provide LM 80 reports alongwith warrantee of 5 years for luminaires i/c drivers with suitable mounting arrangement complete etc. as required at site.
Supplying and Laying of 3 x 10 Sq.mm size one number PVC insulated and PVC sheathed / XLPE armounrd Aluminum Conductor power cable of 1.1 kV grade on wall surface as required. (clamped with 1mm thick saddle)
Supplying and Laying of 3 x 6 Sq.mm size one number PVC insulated and PVC sheathed / XLPE armounrd Aluminum Conductor power cable of 1.1 kV grade on wall surface as required. (clamped with 1mm thick saddle)
Fabrication supply installation and commissioning of safety cage 35 x 35 x 5 height of outdoor of split AC made out of 40 x 40 x 5 mm angle iron and wiremesh 75 x 25 mm of 7.75 kq/sq.mtr 8 SWG wire front open door with locking arrangement with 1 No pad lock i/c copper grouting , fashner, nut bolt, welding etc as required.
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
DRP Air Conditioning Work
A K Electric Works
Naj Refrigeration & Air Conditioning Works
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .