| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.6 LAccepted-AOC COOCH BEHAR | COOCH BEHAR | COOCH BEHAR | WEST BENGAL | 736101 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹22.4 L+₹3.3 L (17.6%)Rejected-Finance 01 BALIA BALIA SAGARDIGHI MURSHIDABAD WEST BENGAL 742237 | MURSHIDABAD | WEST BENGAL | 742237 | L2 | Rejected-Finance L2 | |
| 3 | L3₹24.0 L+₹5.0 L (26.0%)Rejected-Finance 1087 LASKARHAT H 8A NASKARHAT TAGORE PARK KOLKATA KOLKATA KOLKATA 700039 | KOLKATA | WEST BENGAL | 700039 | L3 | Rejected-Finance L3 |
Tender Value
Refer Docs
EMD Value
₹45,000
Closing Date
9 Nov 2020, 1:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE, CED, COB, SUNITY ROAD
Executive Engineer, PWD Cooch Behar Electrical Division
WBPWD/EE/CED/e-NIQ07/20-21
2020_WBPWD_295685_1
WBPWD/EE/CED/e-NIQ-07/2020-21
Open Tender
ELECTRICAL WORKS ORG
Item Rate
25 days
ALIPURDUAR
Please refer tender documents
5 documents required · 5 mandatory
₹45,000
Yes
16 Mar 2021
9 Sept 2020
11 Nov 2020
9 Sept 2020
9 Nov 2020
9 Sept 2020
120 days
Amount
Supply, delivery Installation , Testing & Commissioning of 62.5 KVA, 415V, 50Hz, 3Ø silent DG Set(Make- Caterpiller /Jackson/Kirloskar) having Efficiency not less than 90% comprising of Engine, alternator, separate AMF panel, Base frame, Fuel tank, Battery, CPCB ii approved Acoustic Enclosure having following specifications :- A) ENGINE a) Make -Caterpiller, Cummins b) BHP - Minimum 126 BHP. c) Engine ambient temperature - 50°C. d) Aspiration - Turbo Charged After cooled e) No of Stroke / Cylinder - 4 Stroke / 6 Cylinder inline Diesel Engine f) RPM - 1500.g) Battery - Lead Acid, Low Maintenance or SMF and conforming to relevant IS Specification with Low/High Battery Voltage and Weak Battery warning Make: Exide / Cummins pulse lite . h) Type of Cooling - Radiator cooled with engine water pump and coolant . i) Air Intake System - Air intake manifold with dry type air filter system and vaccum indicator . j) Exhaust System - Provided with turbo charger & residential exhaust silencer with flexible bellow and companion flanges inside the acoustic enclosure. k) Coupling & Fly Wheels - Befitting coupling, Fly wheel & Fly wheel housing. l) Lubricating System - Provided with Oil pan, engine mounted lube oil pump and lube oil filter along with first fill of lube oil. m) Fuel System - Comprising of fuel pump with electronic governor, 12V/ 24V solenoid coil and replaceable fuel filter. n) Starting System - 12V/ 24V DC starting system complete with starter motor, charging alternator with rectifier and Cutout.
B) ALTERNATOR Make - Stamford/ LEROY SOMER/Kirloskar Green/Crompton); Rating - 415 V., 3Ph. 50 Hz., 82.5 KVA, 1500 rpm;Type of Alternator - Brushless, self excited & self-regulated; Voltage Regulation - ± 1% (max.) in static condition; Overload - Permissible overload of 10% for 1 hour in 12 hours of operation; Protection - screenprotected drip proof with Min. IP-23 class; Insulation - Class H; RPM - 1500; Winding connection - Star with Neutral; Short Circuit withstand capability - At least 3 Sec. for 3 Phase Fault; Total Harmonic distortion in output waveform - 3% as per IS-4722.C) Genset Controller: Microprocessor based integrated genset monitoring, metering, protection and control system having following features at minimum Display - LED backlit LCD display with tactile switches & generator set status LED lamps.• Digital AVR for shunt or PMG excitation with torque matching. • Digital electronic governing with temperature ompensation and smart starting.• Remote start-stop.• Engine metering - Oil pressure, Coolant temperature, Battery voltage, Engine speed • AC Alternator metering - L-L Voltage and L-N Voltage, Current (1 and 3 phase), Volt-Amperes (phase and total) and Frequency.• Engine protection - Low lube oil pressure, High/Low coolant temperature, Over speed, Battery Over/Under/Weak Volts, Fail to crank/start, Sensor failure.• AC Alternator protection - Over/Under voltage, Over/Under frequency, Over current, Short circuit and Loss of AC sensing.• Data loggin g - Engine hours, Control hours, Engines
S & F exhaust pipe of 100 mm. dia MS black pipe (Thickness 4 mm) including connection with the existing silencer attached with the flexible coupler and S&F flange, nuts, bolts & washers etc. & necessary fixing materials etc. as required from DG set to nearest building (Horizontal Run) with suitable high temperature painting
S&F exhaust pipe of 150 mm. black pipe (thickness 4 mm.) including S&F flange, nuts, bolts & washers etc. as required from the nearest building wall to top of the building roof. (Vertical run) with suitable high temperature painting.
S&F special type MS angle iron bracket support made of 40x40x6 mm. MS angle with flat iron clamp with nuts, bolts & washers etc. for 150/100 mm. dia (Vertical Run)
S & F compression type metal gland for 150/200 mm dia flexible pipe
Making insulation by 2" glass wool including netting arrangement and covered with aluminium clading as per direction of the EIC. a) 150 mm. dia exhaust pipe
Supply and Fixing rain protection canopy
Supply & Laying of 10 core 1.5 sq.mm. PVC insulated armoured copper cable for control line connection between DG & AMF and connecting the same as per requirement after proper socketing
Making connection of LT power cables, earthing etc. as required.
Earthing with 65 mm. dia GI pipe (ISI Medium) x 6.0 mtr. Long 1 no. 50 x 6 mm. galvanized (Hot dip) sheet strip (4 mtrs. Long) 12 mm. dia x 125 mm. long GI nuts, bolts etc.
Earthing with 50 mm. dia GI pipe (ISI Medium) x 6.0 mtr. Long for equipment body earth as per GS
Extra for treatment of soil by using salt & charcoal or coke for pipe electrode for neutral earth. 2.0
Extra connecting the neutral of DG to earth electrode including S&F 50mmx6mm Galvanized(Hot Dip) steel strip on wall/floor with GI saddles & insulating the same by one layer of PVC strip over one layer of ampere tape
Hiring charges for scaffolding by bamboo, coir rope by square type arrangement for smooth working and lifting of MS black pipe for vertical installation including dismantling after completion of work
S&F MS angle iron structure made of 50x50x6mm MS angle for shade structure & to support 100mm dia MS pipe. Incl necessary arrangement.
Making CC & Brick foundation (10inch brick work) bellow 1mt from GL & 450mm above GL. Of size. 3mt x 1.5mt incl. 3mm thick neat cement finish on all four sides & top.
Supply of 3.5C 70sqmm PVC insulated PVC sheathed / XLPE power cable of 1.1 KV grade as required
Laying of one No. cable above 50 sqmm in underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed.
Laying of cable as below after cutting floor/pavement/wall and making holes incl, embedding the cable at an avg. Depth as below and mending good damages to original finish incl. Removing the rubbish
0 Supplying and making end termination with brass compression glands and aluminium lugs for following sizes of PVC insulated and PVC shethed cable of 1.1 KV grade as required. a) 3 1/2 x 70 sq. mm
Finishing of the XLPE/PVC insulated armoured cable ends by soldering with cable sockets and insulated tapes etc., including supplying sockets, soldering materials, tapes etc. and making connection to switch, BDB and BBC etc.
Shade for silent DG, roof by GI colour sheet (Mk:- TATA/ISI) @ pillar by hollow iron rod (Mk:- TATA/ISI). 4mtr x 3mt
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection . A) 50mm dia
Cost of submission of following documents:- 1) cable root drawing(4 copies) duly signed by the agency and its authorized supervisor. 2) Photograph of during works 3) Test certificates as per IEE regulation & IS 732-1989 and IE rule duly signed by the agency and authorized supervisor as mentioned for the following tests. a) Insulation resistance to earth. b)Insulation resistance between conductor. c) Resistance of metal conduit/sheath d) earth continuity test. e) Leakage current at full connected load, f) earth resistance(g) Load balancing.
Supply of 2.0 Ton capacity (23960 BTU ) having COP 3.29 Split Air Conditioning Machine filled with rotary compressor having cooling capacity 7020 Watt, Air flow volume 636 CFM, suitable for 230V, 50 Hz single phase power supply with plug top of 20 amp capacity. ( Make- Hitachi / Daikin / Mitsubishi/General/Zamil )
Installation charges of 2 Ton Split R.A.C. Machine incl. making arrangement for out door unit by suitable size angle iron frame as per direction of E.I.C.
Supply & Drawing 3/8” and 5/8” Copper pipe with 12.5 mm thick nitrile rubber insulation over it along with other accessories on wall. (make to be approved by EIC)
Supply & Laying of flexible Drain pipe for condensed water. Make approved by EIC
Supply & Laying of PVC Drain pipe for condensed water dia 32 mm make Finolex/Supreme
Designing, Fabrication, Supply, Installation, Testing & Commissioning of Outdoor LED Signage (Approximate Size 12'Length X 4' Height) in English (letters given and approved by concerned department) for letters with following specifications. (a) The box for the signage will be fabricated in Aluminum Square tube of size 25 mm. X 25 mm. of 16 gauge complete with necessary priming and painting. The front of the box will be covered with 3 mm. thick Aluminium Composite Panel (ACP) sheets of the entire board. The board to be fixed in front of canopy by providing required support and Angle Bracing. The complete installation will be water, vermin and dust insulated and protected. (b) Letter Description: Approx 9" x 5" size of letters made of Aclrylic Sheet with male female attachment, on router cut ACP Sheet of front incl. all accessories as required. (c) LED Illumination:High Bright, High Wave length closed type waterproof white LED modules (0.72 W or Higher) mounted on interior side of female part of letter with power wire running back to a central power area with 12 Volt LED Power Transformer to adequately drive the whole LED modules without Flicker.(f)Internal Electrical Wiring will be done by Halogen Free Flame Retardent HRFR compound insulated (Unsheathed) 1.5 Sq.mm. copper flexible cable through interior conduit and Electrical Raceway.
M/S DAS ENTERPRISE
MITRA ENTERPRISE
stage.html
html • 0.05 MB
technical_551275.pdf
PDF • 0.19 MB
techsummary_551275.pdf
PDF • 0.04 MB
finance_551275.pdf
PDF • 0.16 MB
BOQ Comparative Chart
xlsx • 0.01 MB
finsummary_551275.pdf
PDF • 0.04 MB
NIQ07AOC.pdf
PDF • 0.25 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .