Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.5 CrAccepted-AOC | ₹3.5 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹3.9 Cr+₹36.8 L (10.5%)Rejected-Finance | ₹3.9 Cr+₹36.8 L (10.5%) | L2 | Rejected-Finance L2 |
| 3 | L3₹4.0 Cr+₹52.6 L (15.0%)Rejected-Finance | ₹4.0 Cr+₹52.6 L (15.0%) | L3 | Rejected-Finance L3 |
| 4 | L4₹4.2 Cr+₹70.2 L (20.1%)Rejected-Finance E 4 92 2ND FLOOR SECTOR 16 ROHINI N DELHI 85 | DELHI | ₹4.2 Cr+₹70.2 L (20.1%) | L4 | Rejected-Finance L4 |
| 5 | L5₹4.3 Cr+₹76.5 L (21.8%)Rejected-Finance | ₹4.3 Cr+₹76.5 L (21.8%) | L5 | Rejected-Finance L5 |
Tender Value
₹4.8 Cr
EMD Value
₹9.5 L
Closing Date
5 May 2025, 5:00 pmClosed
JITENDER KHURANA
Gurugram University Gurugram
Construction of Construction and Maintainance Office Building (G plus 2) in GUG Sec-87 Gurugram
2025_HRY_441903_1
20252BFAA055 C1E6 4FCD 8541 72F45707D02C1857GGU
Open Tender
Civil Works
Works
487 days
Manesar
2 documents required · 2 mandatory
₹15,000
₹9.5 L
Yes
23 Jul 2025
22 Apr 2025
6 May 2025
22 Apr 2025
5 May 2025
22 Apr 2025
Amount
Providing and fixing of Wooden fire rated doors as per BS:476 Part- 20 and 22 and IS 3614 part-1 and part-2 for stability, integrity and thermal insulation. 03 Criteria Wooden door confirming to IS 277 with the following specification. Recommended fire door shall have doors tested at CBRI for maximum rating of 2hrs tested either with or without vision panel. Individual Test certificates should be available for glass used in vision lites confirming the required fire ratings.Any deviation in specification other than what is mentioned in the test certificates are not allowed. Proper label confirming the type of door and the hourly rating is mandatory. Approved manufacturer Navair International Ltd or equivalent subject to architect’s approval. And should be ISO Certified company. Door leaf shall be minimum 50mm thick fully flush door with or without vision lite. 50mm thick shutter, comprising of 75mm x 44mm hardwood internal timber frame work, with infill of 48 kg/m3, ceramic fiber blankets, coated with VIPER FR intumuscent coating on both sides for insulation. The coated insulation shall be sandwiched between maximum 12mm thick HILUX Make Calcium Silicate Boards on both sides (edge to edge on internal Hardwood frame) having a maximum density of 900 Kgs/ Cum, cladded with 3mm ply commercial ply on both faces. (The same can be pasted with 1mm thick laminate (as per approved shade) or replaced with 4mm thick teak ply as per clients requirement at an extra cost) on both sides of the shutter, with 50mm x 10mm hard wood lipping all round the shutter. r. The rebate shall be of 20mm x 54mm in the Door Frame to accommodate the shutter. Both frame and shutter shall be fitted with intumescent Fire seal strips, The shutter fitted with 20x4mm Fire seal and Frame with 2 no. Fire seal of size 10x4mm on all the three sides of the except bottom. The pasting of the ply/veneer/laminate should be done using automatic machine and should be free from any nails or perforations. (electrical room Doors). Navair, Kutty Make with the prior approval of engineer-in-charge.
Supply and fixing the door frame will be made out of Hardwood of maximum section 120 x 70mm and coated with VIPER Fire reatrdent Primer. Navair, Kutty Make with the prior approval of engineer-in-charge
Supply and fixing SS Ball Bearing Hinges of size 100 x 75 x 3mm complet with SS Screws of BB1953 e ( 4 Nos per panel ) (Required For All Doors). Becker F.S -MS. Navair, Kutty Make with the prior approval of engineer-in-charge
Supply and fixing Panic Bar Double leaf panic exit devicesPEL 346 . (Required For Fire Staircase Location Doors Only). (Main Hall Doors) Becker F.S. Navair, Kutty Make with the prior approval of engineer-in-charge
Supply and fixing PEL905 Becker F.S. Make Panic Trim For Operation From The Other Side Of The Panic Bar. (Required For Fire Staircase Location Doors Only).Navair, Kutty Make with the prior approval of engineer-in-charge
Supply and fixing Mortise Dead Lock with 80mm cylinder body both side key DL7260 Becker F.S. Dead Lock Required For Shaft Door Location). Navair, Kutty Make with the prior approval of engineer-in-charge
Supply and fixing SS D Type Pull Handle of size 300mm mm Long of PHD2230.Navair, Kutty Make with the prior approval of engineer-in-charge
Supply and fixing Door closers of BLC-604 (Required For All Fire Doors Except Shaft Door). Make - Becker F.S or equivalent with the prior approval of engineer-in-charge
Supply and fixing Stainless Steel 304 grade 300mm Long Tower Bolt of with necessary screws as required Make - Becker F.S or equivalent with the prior approval of engineer-in-charge
Supply and fixing Anchor fastners of of maximum 120mm length. Make - HILTI, FISHER or equivalent with the prior approval of engineer-in-charge.
Supply and fixing IS-1212 S88 UL 1784-01 Smoke tested adhesive seal Make Smoke seal batwing type on all side of frame. Make - LORIENT/ Becker FS / PEMKO with the prior approval of engineer-in-charge.
Supply and fixing 5 MM thick clear Non wire 2 Hr Fire Vision glass 300x300mm. Make - Saint gobain or Equivalent with the prior approval of engineer-in-charge.
Providing and Fixing SS ball bearing hinge (4 x 3 x 3mm) - Isuzul/Godrej/Hettich or equivalent make as per prior approval of Engineer-in-Charge.
Providing and Fixing Tower bolt 12` Aluminium - Godrej/ Ebco/ Hafele make as per prior approval of Engineer-in-Charge.
Providing and Fixing SS finish door stopper - Model Godrej/ Ebco/ Hafele make as per prior approval of Engineer-in-Charge.
Providing and Fixing SS back stopper - Model Godrej/ Ebco/ Hafele or equivalent make as per prior approval of Engineer-in-Charge.
Providing and Fixing Pull handle 240 mm - Model Godrej/ Ebco/ Hafele or equivalent make as per prior approval of Engineer-in-Charge.
Providing and Fixing Ebco Euro window handle for Outward Opening Window - Model E-WH1 Ebco/ Hafele/Godrej or equivalent make as per prior approval of Engineer-in-Charge.
Providing and Fixing Ebco Euro window handle with hook for Inward Opening Window - AWH-H1R ( HB ) Ebco/ Hafele/Godrej or equivalent make as per prior approval of Engineer-in-Charge.
Providing and Fixing Door Closer 60 kg Tto 90 kg of Ebco, Godrez make as per prior approval of Engineer-in-Charge.
Providing and Fixing Mortise lock and latch with both side handle and keyed cylinder. 5991 NEH-16, 200mm of Ebco, Godrez make as per prior approval of Engineer-in-Charge.
Providing and Fixing Patch fittings with 90 kg Floor spring and of Ebco, Godrez make as per prior approval of Engineer-in-Charge.
Providing and Fixing H Handle SS 304 , 750 mm hole to hole of Ebco, Godrez make on both side of door as per prior approval of Engineer-in-Charge.
Providing and Fixing ALDROP 16*200mm stainless steal complete in all respect of Godrej/ Ebco/ Hafele or equivalent make as per prior approval of Engineer-in-Charge.
Providing and Fixing Sliding roller with necessary screws etc. complete as per direction of engineer in-charge (used in windows/doors) Make:(EBCO,Dorma, hafle) Complete in all respect with the prior approval of enginer. Incharge.(For sliding Windows)
Providing and Fixing Sliding lock 1925(Manul) model no. -P-SWL-IM of Ebco make with necessary screws etc. Make:Hindware,ozone,dorma Complete in all respect with the prior approval of enginer in Incharge.
Providing and fixing stainless steel grade 304 corner lock, strike plate and Euro Profile Cylinder of approved make in glass door shutters etc with necessary accessories/screws etc. complete as per the directions of Engineer-in-charge.(Dorma,Godrej or EBCO)
Providing and fixing solid laminated flush door shutters having uniform thickness of 37mm with smooth finish and moisture content 10 to 12% with water absorption of 2%, climate stable, warp and bend free as certified by IS-2202 with 1mm HPL conforming to IS - 2046 including , screws chocks/cleats and stops etc. (excluding the cost of any fittings other than specified above, but including labour for fixing the same in position).(Greenlam, century make, duro)
Providing and laying smooth stone texture paint in colors shade and texture as per approval applied by a coat applied by a spray gun in the desired shade of approved make including sand papering the existing surface of putty, to give it a base for applying primer coat. It also includes scaffolding charges complete in all respect (FOR EXTERIOR FACADE) (N.S.ITEM). of Heritage Paints or Equivalent make as per prior approval of Engineer-in-Charge.
Providing and fixing FRAMELESS GLASS INTERNAL PARTITIONS with 12mm clear tougnened glass with glass division of 1.8m c/c/ of approved make as per elevation drawings with fixing clips including filling up necessary gaps at junction, at top, bottom and sides with required weather silicon (Grade-995), and the sides shall be sealed with backer rod inserted in between aluminium channel and glass as well as both inside and outside around the periphery of the glass to make the glazing air and water tight as per design drawings complete with all respect and direction of Engineer in charge. saint gobain or equivalent
Providing, supply and installation of Flux polycarbonate multi-layered, Multicell Connectible modular panel system for, a complete assembly of coextruded UV protected polycarbonate panels incorporated into a complete system. Standing seam polycarbonate panel system.of minimum 16 mm thick (Min.) Panels with bigger width will be preferred for reducing number of joints in the roof. Panels shall be with grip lock double tooth locking mechanism with interlocking connectible connectors running lengthwise at both sides of the panel. Panels shall be fixed on Purlins of MS structure (will be paid Separately) with 3 numbers of self-drilling screws to ensure a pull-out load of min. 7000 N (7KN) tested as per ISO 6892:1998 and IS 1608: 2005. Panels shall be in biolocur combination whihc is half upper body in reflective colour to reflect heat and bottom half of the panel in Ice colour for better diffusion and cool light with all fixing accessories to ensure best performance for wind uplift, vibration, oil canning and visual appearance. Panel to achieve angular daylighting effect to avoid sunglight and heat. U value shall not be more than 2.1 Watt/m2K as per EN ISO 1077-2:2018 and respective third Party test certificate shall be produced before procurement. Panels shall have an X cell strucutre also called truss bracing design to have more strenght and flexibility simulatneously. Panels must satisfy Dart drop impact test as per IS 14443-97 shall show no sign of breakage on Polycarbonate sheets which have been exposed to UV for a min. of 500 Hours as per ASTM G 155. Panels shall not have Yellowness Index as per ASTM D2244 (standard D65 illuminant, CIELAB) not more than 1 unit when tested on a sample exposed to UV/weathering test for 2500 Hours as per ASTM D4329. The panel shall be with additional sealing / breathing tape, Aluminum U profile for ends, screws etc. as per standard accessories as required. Panel shall be fixed conforming to the detailed methodology and guideline as per the manufacturer. Trained and factory authorized labor shall be used with supervision to complete the entire panel installation as per drawing and direction of the engineering in charge ( LOCATION: TERRACE and PARKING SHED ) ( MAKE: DPI DAY LIGHTING, GE, LEXAN )
Providing and fixing Hand shower (Health faucet) with 1.0m long easy flex tube in chrome finish and wall hook (model no. ALD-565) Jaquar or equivalent with prior approval of Engineerin charge.
Providing and fixing in position two way Bib cock for and hand shower (model CON-041KN) of Jaquar make o or equivalent with prior approval of Engineerin charge
Providing and fixing in position Angle Valve (model No.CON-059KN) of Jaquar make or approved by Engineer-in-Charge
Providing and fixing in position Central hole basin mixer without popup waste system with 450mm having long braided hoses (model (No Suggestions)) of Jaquar make or equivalent with prior approval of Engineerin charge.
Providing and fixing in position 15 mm i/d wall mounted sink cock with swinging casted round shape spout (Model No.CON-347KN) of Jaquar make or equivalent as per prior approval of Engineer-in-Charge
Providing and fixing under counter Basin (model No. CNS-WHT-705) of Jaquar make or equivalent as per prior approval of Engineer-in-Charge., complete in all respect.
Providing and fixing in position Geyser of 25 liters capacity (Model-ELM-WHT-V025) of Jaquar make or equivalent with prior approval of Engineerin charge.
Providing and fixing in position Bottle trap (model no.ALD-769L300x190) with internal partition 32mm size with 300mm and 190mm Long wall connections pipes and wall flange and waste coupling(model no.ALD-705L130) 32mm size full thread with 130mm Height of of Jaquar make or equivalent with prior approval of Engineerin charge
Providing and fixing Pillar Cock long neck with 450mm long braided Hose (model No. CQT -23021B) of Jaquar make or equivalent as per prior approval of Engineer-in-Charge.
Providing and fixing Wall Hung Basin (model No. CNS-WHT-801) with fixing accessories set size (550x410x195mm) of Jaquar make or equivalent as per prior approval of Engineer-in-Charge
Providing and Fixing SWR Fittings (supreme make) for type B pipes 110mm dia including fixing jointing and testing etc. Supreme make or equivalent as per prior approval of Engineer-in-Charge FLOOR TRAP WITH TOP TILE and STAINER(125mm)
Providing and Fixing SWR Fittings (supreme make) for type B pipes 110mm dia including fixing jointing and testing etc. Supreme make or equivalent as per prior approval of Engineer-in-Charge. DOOR TEE
Providing and Fixing SWR Fittings (supreme make) for type B pipes 110mm dia including fixing jointing and testing etc. Supreme make or equivalent as per prior approval of Engineer-in-Charge. DOOR BEND (TS)
Providing and Fixing SWR Fittings (supreme make) for type B pipes 110mm dia including fixing jointing and testing etc. Supreme make or equivalent as per prior approval of Engineer-in-Charge BEND 87.5 °
Providing and Fixing SWR Fittings (supreme make) for type B pipes 110mm dia including fixing jointing and testing etc. Supreme make or equivalent as per prior approval of Engineer-in-Charge. DOOR CROSS TEE
Providing and Fixing SWR Fittings (supreme make) for type B pipes 110mm dia including fixing jointing and testing etc. Supreme make or equivalent as per prior approval of Engineer-in-Charge COUPLER
Providing and Fixing SWR Fittings (supreme make) for type B pipes 110mm dia including fixing jointing and testing etc. Supreme make or equivalent as per prior approval of Engineer-in-Charge. DOOR CAP
Providing and Fixing SWR Fittings (supreme make) for type B pipes 110mm dia including fixing jointing and testing etc. Supreme make or equivalent as per prior approval of Engineer-in-Charge VENT COWL
Providing and Fixing SWR Fittings (supreme make) for type B pipes 110mm dia including fixing jointing and testing etc. Supreme make or equivalent as per prior approval of Engineer-in-Charge CLEANOUT
Providing and Fixing SWR Fittings (supreme make) for type B pipes 160mm dia including fixing jointing and testing etc. Supreme make or equivalent as per prior approval of Engineer-in-Charge. DOOR TEE
Providing and Fixing SWR Fittings (supreme make) for type B pipes 160mm dia including fixing jointing and testing etc. Supreme make or equivalent as per prior approval of Engineer-in-Charge. COUPLER (RIB TYPE)
Providing and Fixing SWR Fittings (supreme make) for type B pipes 160mm dia including fixing jointing and testing etc. Supreme make or equivalent as per prior approval of Engineer-in-Charge. VENT COWL
Providing and Fixing SWR Fittings (supreme make) for type B pipes 160mm dia including fixing jointing and testing etc. Supreme make or equivalent as per prior approval of Engineer-in-Charge. DOOR ELBOW
Providing and Fixing SWR Fittings (supreme make) for type B pipes 160mm dia including fixing jointing and testing etc. Supreme make or equivalent as per prior approval of Engineer-in-Charge. CLEANOUT
Providing and fixing of 1 No. U-shaped rail with wall mounting of (Size: 600x100mm) at fixed height for handicap toilet complete as required. (Make-CERA, Model-2501) (Hindware, Cera, Parryware) (Used in Handicapped toilet) complete in all respect With the prior approval of enginer Incharge
Providing and fixing of 1 No. Wall Mounted Grab Bar of (Size: 500mm) at fixed height for handicap toilet complete as required. (Make-CERA, Model-2504) (Hindware, Cera, Parryware) (Used in Handicapped toilet) Complete in all respect With the prior approval of enginer Incharge
Providing and fixing Centralized R.O system with chillar plant of the capacity - 200 litres / hr and storage SS water tank of 1000 litres complete including fixing in position ( All pumps working with standby provision). (TERRACE) (MAKE:Aquagard,ionchange or equivalent ISI Mark) (Used at Terrace) With the prior approval of enginer Incharge
Providing and Fixing automatic `NO-Touch ` electric hand-driers complete with all accessories and fittings. (Make: Jaquar Model No. HDR-SAP-M99ACS) (Jaquar, Euronics and Kingston) (Used in Toilets) With the prior approval of enginer incharge)
Providing and executing modular harvesting pit of recycled polyprpylene material with crush load capacity of 20-25 tons per square metre and load bearing strength of 40 tons. The pit shall be wrapped with geotextile faabric material to prevent soil insertion and effective insertion of sorrounding water. The Geotextile material shall be UV resistant and conforming to ASTM 154/EN 12224.he cost shall be inclusive of all necessary excavation in all kind of soils, boring upto 30 mtr, refilling and disposal of surplus earth with in the site or away from site as directed with out any extra cost including required nos. 750 x 750 mm, Medium Duty , Wt : 125 kg, Ductile Iron cover with frame for Filter chamber. (All sizes are clear internal sizes). Depth shall be as per actual site condition and invert level. With the prior approval of enginer incharge) Size- 3 mtr. X 3 mtr. X 2.25 mtr. water depth WD
Supply, installation , testing and commissioning of UPVC (Class III) of pressure rating 6 bar for waste pipe connection for washbasin/urinals/sinks conforming to IS:4985 cut to required lengths including all necessary fittings and specials. Fixing at wall/ceiling level all type of supported by MS hot dipped galvanised angle support for vertical and horizontal pipe fixing with GI u clamp and hangers etc. Cutting chases/holes in floors/walls/slab etc. Supreme or equivalent make as per prior approval of Engineer-in-Charge. 40 mm dia (6 bar pressure rated)
Supply, installation , testing and commissioning of UPVC (Class III) of pressure rating 6 bar for waste pipe connection for washbasin/urinals/sinks conforming to IS:4985 cut to required lengths including all necessary fittings and specials. Fixing at wall/ceiling level all type of supported by MS hot dipped galvanised angle support for vertical and horizontal pipe fixing with GI u clamp and hangers etc. Cutting chases/holes in floors/walls/slab etc. Supreme or equivalent make as per prior approval of Engineer-in-Charge. 50 mm dia (6 bar pressure rated)
LT PANEL:Supply, unloading, installation, testing and commissioning of the following cubical type panels made of 2.0 CRCA structure, base channe lSMC, doors and sheet metal partitions complete with, Moulded Case Circuit Breakers, meters, indicating lamps, current transformer, control MCB etc. Complete in all respects, insulated bus bars with heat shrinkable PVC sleeve, supported on FRP/ SMC supports in suitable bus chambers, interconnection, small wiring, name plate, danger plate, earth bus etc. and comprising of compartments with hinged door for each feeder and its accessories, cable alley with hinged doors, bus chamber with bolted door etc. The panel being of dust and vermin proof construction with rubber gasket, attractively powder coated with Approved Paint shade. The panel shall be free standing type/ wall mounted type as per relavant drawing and comprising with foundation and Masonary works including ducting. Note:- Breaking Capacity of all MCCB`s are Ics Service Breaking Capacity. MCCB`s upto 250A shall be with Adjustable thermal-magnetic and above 250A Microprocessor based adjustable release. All MCCB`s shall be Front door operating handle, Phase Spreaders and Phase Barriers. TPN MCCB Shall mean 3Pole MCCB with Adequate size of separate neutral link. Metering CTs burden shall be 15VA and accuracy class 1.0. CTs shall be `CAST RESIN` type. All indication lights shall be LED type. All meters shall be `DIGITAL` type. Degree of Protection for Indoor panels shall be IP-55 with canopy and double for Outdoor Panels, cable entry from bottom only. Panel space heaters with control MCB and Thermostat, covered CFL lamp controlled by door switch for each panel bay. Gland plates shall be 2mm thick for LT. Panels upto 400A Incomer and 3 mm thick for LT. Panel with 630A and above incomer. Panel Manufacturer should have Type Test Certificates for Short Time withstand current test of 50kA for 1.0 Sec from CPRI Bhopal/ Bangalore. `ON` Indicating lamp shall be provided for all 3 phase MCCB out going feeders unless otherwise specified. Control SP MCB`s of 2/4A Rating shall be provided for each metering circuit. Building Panel : Incoming - 1 Set of 400 Amps. 415 Volts, FP MCCB of 25 KA with overload, O/V, O/C and earth fault protection. Incoming for Solar- 1 Set of 100 Amps. 415 Volts, FP MCCB of 25 KA with overload, O/V, O/C and earth fault protection. Bus bars: 1 Set of 630-Amps, 3-Phase, 4-wire, 415 volts, 50 Hz Aluminium bus-bars with colour coded PVC heat shrinkable sleeves (Neutral to be equal to phase size). Metering and Indication: One set of R/Y/B phase indication Lamp and MCB. 1 No. Multi Function Meters (A/V/kW/kWh).ON/OFF/TRIP indication lamp for incomer. Outgoing: 5 Nos. 63 Amps. FP MCB of 10 KA. 3 Nos. 40 Amps. FP MCB of 10 KA. 1 Nos. 32 Amps. FP MCB of 10 KA. 2 Nos. 25 Amps. FP MCB of 10 KA. 4 Nos. 100 Amp FP MCCB of 25 KA with overload, S/C protection. Panel as mentioned above should be complete in all respect with internal wiring, al. bus bar etc. (AT FLOOR ELEC. ROOM)
LIGHT FIXTURES and FAN: Supply, Installation, Testing and Commissioning of luminaires basic channel, holder, LED driver (as per mentioned in item), starter, condenser, control gear box complete with decorative attachments, lamps etc. as per specifications and as per catalogue number giving below. 15 Watt LED Recessed type LED downlighter. Liminaire should be extruded/ PDC housing of Aluminium, THD less then 10%. LD06-171-XXX-57-XX - 1500lm Wipro, Philips and Havells make with prior approval of Engineerin charge. (FOR CIRCULATION AREA)
LIGHT FIXTURES and FAN: Supply, Installation, Testing and Commissioning of luminaires basic channel, holder, LED driver (as per mentioned in item), starter, condenser, control gear box complete with decorative attachments, lamps etc. as per specifications and as per catalogue number giving below. 15 Watt LED Surface Mounted LED downlighter. Liminaire should be extruded/ PDC housing of Aluminium, THD less then 10%. Wipro LD06-171XXX-57SMG1 - 1500lm, Philips and Havells make with prior approval of Engineerin charge. (FOR STAIRCASE)
LIGHT FIXTURES and FAN: Supply, Installation, Testing and Commissioning of luminaires basic channel, holder, LED driver (as per mentioned in item), starter, condenser, control gear box complete with decorative attachments, lamps etc. as per specifications and as per catalogue number giving below. 9 Watt LED Bulk-Head light fixture. Liminaire should be extruded/ PDC housing of Aluminium, THD less then 10%. Wipro - LW07-141-XXX-57-G1,Philips and Havells make with prior approval of Engineerin charge. (FOR SHAFT and TERRACE)
LIGHT FIXTURES and FAN: Supply, Installation, Testing and Commissioning of luminaires basic channel, holder, LED driver (as per mentioned in item), starter, condenser, control gear box complete with decorative attachments, lamps etc. as per specifications and as per catalogue number giving below. 36 Watt Surface mounted batten LED Light fixture. Liminaire should be extruded/PDC housing of Aluminium, THD less then 10% Wipro LL24-541-XXX-57-XX - (110lm/w), Philips and Havells make with prior approval of Engineerin charge. (FOR SERVICES ROOM)
LIGHT FIXTURES and FAN: Supply, Installation, Testing and Commissioning of luminaires basic channel, holder, LED driver (as per mentioned in item), starter, condenser, control gear box complete with decorative attachments, lamps etc. as per specifications and as per catalogue number giving below. 11 Watt Surface mounted 600mm length LED Mirror Light fixture. Philips and Havells make with prior approval of Engineerin charge. (FOR TOILET)
Providing and fixing of 7 module Pop-up Box complete with 2 x 6A, 5pin switched socket outlets and 2 nos. N/W nodes with company`s factory fabricated moulded outlet box as may be required.
FANS, EXHAUST FANS, CABIN FANS AND SOCKETS: Supply, Installation, Testing and Commissioning of Exhaust fans/ wall fan/ Ceiling Fans of following sizes including making the holes to suit the size of the fan and making good the damages, including providing and fixing of louvers/ shutters, connection, testing and commissioning. Ceiling Fan 1200 mm white color 2 Star, ISI Marked Specifications Havells - ES Plus, Usha, Orient, Crompton make with prior approval of Engineerin charge. (FOR CON. HALL, LAB, CLASS. MEETING, SE. FAC. ROOM ETC)
LIGHTNING PROTECTION AS PER IEC 62305/ NBC 2016 AT LVL -II (10X10 MTR) (FOR WHOLE BUILDING, AT TERRACE) Supply of Vertical Aluminium Lighting Arrester of 16MM dia, 2000 mm long with Gun Metal base plate and 2 mtr GI Pipe. Model : APSAT416AL plus APSTB16-253 Make : APS
LIGHTNING PROTECTION AS PER IEC 62305/ NBC 2016 AT LVL -II (10X10 MTR) (FOR WHOLE BUILDING, AT TERRACE) Supply 8 mm round aluminium conductor for horizontal lightning protection - run in roof. Model : AL8. Make : APS
LIGHTNING PROTECTION AS PER IEC 62305/ NBC 2016 AT LVL -II (10X10 MTR) (FOR WHOLE BUILDING, AT TERRACE) Supply of roof conductor holder for 8 mm round aluminium conductor made of SS 304 for horizontal installation. The distance between each holder should be min of 1 mtr. Model : APSRCHSS50. Make : APS
LIGHTNING PROTECTION AS PER IEC 62305/ NBC 2016 AT LVL -II (10X10 MTR) (FOR WHOLE BUILDING, AT TERRACE) Supply of T/Cross connector for connecting of 8 mm Al round conductor. The connector should be of SS 304 with SS nuts and bolt. Model : APSCCTSS50, Make : APS
LIGHTNING PROTECTION AS PER IEC 62305/ NBC 2016 AT LVL -II (10X10 MTR) (FOR WHOLE BUILDING, AT TERRACE) Supply of Expansion piece along with connector to compensate the expansion of round 8 mm Al conductor when temperature variation. Connection should be in every 20 mtr. Model : APSEXP50, Make : APS
LIGHTNING PROTECTION AS PER IEC 62305/ NBC 2016 AT LVL -II (10X10 MTR) (FOR WHOLE BUILDING, AT TERRACE) GLUE- Glue is used to fix roof conductor holder on roof. DOWN CONDUCTOR and RING CONDUCTOR AS PER IEC 62305 (FOR WHOLE BUILDING, AT BUILDING FAÇADE and EXTERNAL)
Supply of 8 mm round aluminium conductor as a down conductor mounted in the surface of wall which will carry the lightning current to earth pit. Model : AL8. Make : APS
Supply of Down conductor holder made of SS 304 for 8 mm round aluminium conductor of min distance between the wall to the conductor will be of 85 mm. The distance between each holder should be min of 1 mtr. Model : APSDCHSS50 Make : APS
Supply of straight connector for connecting of 8 mm Al round conductor. The connector should be of aluminium with SS nuts and bolt. Model : APSPCRC50, Make : APS
Supply of Test Joint Point for 25X3MM CU STRIP, the size should be of 25 x 3 x 150 mm copper in ABS boxes. Model : APSTLBCU. Make : APS EARTHING AS PER IEC 62561- 2 and 7 (FOR WHOLE BUILDING, AT EXTERNAL)
SITC of Galvanised Steel Flat 25X3 mm thickness from earth electrode directly in ground as required. Flat conductor shall be of Hot Dipped and Cross sectional area of 90mm square According to DIN EN 50164-2 (VDE 0185 part 202) Meets the requirement of VDE0185/ 305(IS-IEC 62305) Zinc coating: 500 g/m square (Approx: 70 micron coating) Should be tested and used exclusively for lightning protection earthing system and ring equipotential bonding complete etc as reqd.
Supply of advance chemical gel earthing system for the proper dissipation of fault/ leakage current to the ground and ensure the continuous electrical connectivity and proper functioning to the electrical system. The earth rod shall be of UL listed and CPRI tested 3 meter long 25.4 mm dia 250 microns copper bonded steel rod with the connecting clamp (ss - rod to tape). The UL listed copper bonded rod also should be tested and ceritifed from CPRI for a short circuit current of 50kA or more. The UL listing shall be punched/ engraved on the rod for the physical verification at site. The engravings shall contain the following details-UL Control number, Dimension details of the rod, Product model number and UL certificate reference number as per detailed technical specification attached. To ensure the electrical conductivity, 50 Kgs (per pit) or more resistance grounding minerals per earth pit/ earth rod shall be used along with the copper bonded rod. As per IEEE 80-2013 (Clause 14.5 d), the grounding minerals shall be tested and certified for the resistivity of less than 0.12 ohm-mtr. The grounding minerals should be ROHS certified to ensure it does not pollute the ground water as per technical specification attached.
RESPONSE INDICATORS: Supply of Response Indicators with Single LED.
MANUAL CALL POINT: SITC of Intelligent Addressable Manual Pull Stations/ Manual Call Points suitable for wall/ column mounting. MCP shall have red coloured housing with molded, raised-letter operating instructions of contrast colour. The MCP shall latch mechanically upon operation and shall remain so until manually reset with its key by an authorized operator. The MCP shall have operating temperature range from 0°C to 50°C and humidity tolerance range up to 93% RH, Non-Condensing.
FAULT ISOLATOR: SITC of Intelligent Addressable, Supervised Short-Circuit Isolator. The Isolator Monitor Module shall have operating temperature range from 0°C to 49°C and a humidity tolerance of up to 90% RH, Non-Condensing.
MODULES: SITC of Intelligent Addressable, Supervised Monitor Module monitoring Potential-free, Normally Open Dry Contact input. The Monitor Module shall have operating temperature range from 0°C to 70°C and a humidity tolerance of up to 93% RH, Non-Condensing. UL EN and ULC Listed and FM make with prior approval of Engineerin charge.
SITC of Intelligent Addressable Potential-free, Form-C, SPDT contact based control module to trigger 3rd party utilities like Pressurization fan activation, Special notification activation etc. The contact shall be rated for 2A@24Vdc (Resistive) and 1A@24Vdc (Inductive). The control module shall have operating temperature range from 0°C to 49°C and a humidity tolerance of up to 93% RH, Non-Condensing. UL EN and ULC Listed and FM with prior approval of Engineerin charge
CABLE: Supply and laying of 2 core 1.5 Sq mm stranded plain annealed copper conductor glass mica taped, XLPE insulated, LSZH inner sheathed, galvanised steel wire armoured and over all LSZH out sheatheated fire survival cable generally as per BS:7846:2009 including connections etc as required. The cable will be fixed on surface with suitable saddles at an interval of not more than one meter
FIRE EXIT SIGN:Supply of emergency fire exit sign boards, with both side display provision with suitable hanging arrangment complete in all respect as required
SITC 9U, wall mounted type standard alluminium Rack with front Acrylic door and lock, rear door with lock, wired power and signal Channel duly powder coated
CCTV SYSTEM : (FOR BUILDING ENTRY and EXIT, CIRCULATION AREA) CCTV HONEYWELL/ BOSCH/ PELCO/ HEINRICH: Supply, installation, testing and commissioning of of IR indoor Dome type, 1/3` 4 MP, progressive scan dual Streaming: H.265 smart codec, dual stream support, 2688 x 1520 resolution, Auto lens detection (2.7-13.5 mm), compatible with digital video recorder, PoE (802.3af) or 12 VDC support, UL/CE Listed, ONVIF conformant with IP 66 weather proof housing and 30 mtrs IR range. Honeywell or eqv. with prior approval of Engineerin charge.
SITC of IR indoor bullet type, 1/3` 4 MP, progressive scan dual Streaming: H.265 smart codec, dual stream support, 2688 x 1520 resolution, Auto lens detection (2.7-13.5 mm), compatible with digital video recorder, PoE (802.3af) or 12 VDC support, UL/CE Listed, ONVIF conformant with IP 66 weather proof housing and 50 mtrs IR range. Honeywell cat no. HBW4PER2 or eqv. with prior approval of Engineerin charge.
Supply, Installation, Testing and commissioning of 32 Channel NVR (Network Vedio Recorder), for recording upto 32CH @ 1080P with 08 nos. SATA HDDs minimum 80TB storage or more (recording requirement all cameras recording at 2MP, 25fps for 30 days), H.265/ H.264/ MJPEG/ MPEG4 codec decoding, Front Control Pannel with LEDs Indication, 3 nos. USB, iPhone: iPad: Android based Mobile clients, Video Export feature on USB, Search Mode: Time/ Date: Alarm: Motion Detection (MD): Exact Search (accurate to a second): Smart Search, Dual HDMI Output, Alarm Input (16 nos.), Alarm Output (4 nos.), eSATA Device, 320Mbps each Incoiming and Outgping throughput, Operating Temperature –10°C to 55°CCertification: CE, FCC and UL including fixing accessories and cable termination with required connectors/ Jack, complete in all respect as per instruction of engineer in-charge
SITC of of 6TB Survillance Hard Disk of SEGATE/WB/SAMSUNG make with prior approval of Engineerin charge.
Supply, Installation, Testing and Commissioning of 16 port L2 web Managed switch having port density 16 Nos. of 10M/100M/1G RJ45 Port POE/POE plus ports, 2 Nos. of 1G/10G SFP Ports, 1X console port, Available POE power 370 W, 128 Gbps switching bandwidth, 16K MAC address support. DLINK/CISCO/HP make with prior approval of Engineerin charge.
Supplying and laying of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed steel/ PVC conduit as required. 4 Pair CAT6 Unshielded, Twisted Pair (U/UTP) Cable. Blue in colour conforming to the following standards like ANSI/TIA 568 C.2, EN50173, IEC 11801 2nd ED, 700Mhz etc. in Cat 6 U/UTP LCS2 cable with 23AWG. DLINK/LEGRAND/MOLEX make with prior approval of Engineerin charge.
Supply, Installation, Testing and Commissioning of Full HD 32` LED Professional Display Panel. SONY/LG/SAMSUNG
FLOOR RACEWAY: (FOR FLOOR LEVEL, POWER and ELV DISTRIBUTION) Supply, laying of following sizes GI Raceway complete with all accessories including junction box with 3 mm thick cover plate, neoprene gasket in joints, cutting the floor and jamming the raceway with all necessary hardware (including civil works) as required. MEM/ OBO/ BEC make with prior approval of Engineerin charge 50 x 40 mm
FLOOR RACEWAY: (FOR FLOOR LEVEL, POWER and ELV DISTRIBUTION) Supply, laying of following sizes GI Raceway complete with all accessories including junction box with 3 mm thick cover plate, neoprene gasket in joints, cutting the floor and jamming the raceway with all necessary hardware (including civil works) as required. MEM/ OBO/ BEC make with prior approval of Engineerin charge 100 x 40 mm
FLOOR RACEWAY: (FOR FLOOR LEVEL, POWER and ELV DISTRIBUTION) Supply, laying of following sizes GI Raceway complete with all accessories including junction box with 3 mm thick cover plate, neoprene gasket in joints, cutting the floor and jamming the raceway with all necessary hardware (including civil works) as required. MEM/ OBO/ BEC make with prior approval of Engineerin charge 225 x 40 mm
TELEPHONE SYSTEM: (AT ELEC./ ELV ROOM) Supply installation and testing and commissioning of follwing size of Telephone distribution board in a M.S. box with hinged cover/ door complete with krone type tag block with double jumpering facility mounted on a bakelite sheet etc. including terminations of cable as required 10 Pair telephone distribution board
TELEPHONE SYSTEM: (AT ELEC./ ELV ROOM) Supply installation and testing and commissioning of follwing size of Telephone distribution board in a M.S. box with hinged cover/ door complete with krone type tag block with double jumpering facility mounted on a bakelite sheet etc. including terminations of cable as required 20 Pair telephone distribution board
Supplying and laying of following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, armored telephone cable in the existing surface/ recessed steel/ PVC conduit as required 10 Pair
Supplying and laying of following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, armored telephone cable in the existing surface/ recessed steel/ PVC conduit as required 20 Pair
L.T. CABLES SUPPLY (POLYCAB/KEI/RR KABEL: Supply and Installation of the following 1100 Volts Al/ Cu. Conductor, PVC insulated PVC sheathed, steel armoured/ unarmoured or XLPE cables as per IS-1554/ 7098 Part- I and as per standard specification (FOR OFFICE BUILDING, CONNECTING TO PANEL and DB`S) 4 core 4 sq.mm CU. XLPE ARM CABLE
L.T. CABLES SUPPLY (POLYCAB/KEI/RR KABEL: Supply and Installation of the following 1100 Volts Al/ Cu. Conductor, PVC insulated PVC sheathed, steel armoured/ unarmoured or XLPE cables as per IS-1554/ 7098 Part- I and as per standard specification (FOR OFFICE BUILDING, CONNECTING TO PANEL and DB`S) 4 core 6 sq.mm CU. XLPE ARM CABLE
L.T. CABLES SUPPLY (POLYCAB/KEI/RR KABEL: Supply and Installation of the following 1100 Volts Al/ Cu. Conductor, PVC insulated PVC sheathed, steel armoured/ unarmoured or XLPE cables as per IS-1554/ 7098 Part- I and as per standard specification (FOR OFFICE BUILDING, CONNECTING TO PANEL and DB`S) 4 core 16 sq.mm CU. XLPE ARM CABLE
Supply and Installation of Fire Survival armoured cables of 600 / 1000V rated with Copper circular conductor having glass mica fire barrier tape covered by an extruded layer of XLPE GP 8 insulation and LSZH inner and outer sheath. Generally as per BS 7846, IEC-60502-1 and BS-8519 (latest edition). Should retain circuit integrity as per BS 8491:2008 (120 mins) for cables having overall dia of 20mm and above. Cables with overall dia below 20 mm should retain circuit integrity as per BS 8434-2. Cable shall be manufactured as per TUV/ BRE/ LPCB certification. (FOR WHOLE BUILDING, CONNECTING SAFETY EQ. FROM PANEL) 4 core 4 sq.mm CU. XLPE FS ARM CABLE
Supply and Installation of Fire Survival armoured cables of 600 / 1000V rated with Copper circular conductor having glass mica fire barrier tape covered by an extruded layer of XLPE GP 8 insulation and LSZH inner and outer sheath. Generally as per BS 7846, IEC-60502-1 and BS-8519 (latest edition). Should retain circuit integrity as per BS 8491:2008 (120 mins) for cables having overall dia of 20mm and above. Cables with overall dia below 20 mm should retain circuit integrity as per BS 8434-2. Cable shall be manufactured as per TUV/ BRE/ LPCB certification. (FOR WHOLE BUILDING, CONNECTING SAFETY EQ. FROM PANEL) 4 core 6 sq.mm CU. XLPE FS ARM CABLE
Supply and erection of Cu. lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. (FOR OFFICE BUILDING, CABLE TERMINATION) 4 core 4 sq.mm CU. XLPE ARM CABLE
Supply and erection of Cu. lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. (FOR OFFICE BUILDING, CABLE TERMINATION) 4 core 6 sq.mm CU. XLPE ARM CABLE
Supply and erection of Cu. lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. (FOR OFFICE BUILDING, CABLE TERMINATION) 4 core 16 sq.mm CU. XLPE ARM CABLE
MISCELLANEOUS ITEMS : Supply and Installation of First aid box as approved by St. John Ambulance Brigade/ Indian Red Cross conforming to IS : 2217-1963. (FOR ELEC. ROOM)
Supply and Installation of Shock treatment chart in Hindi and English duly mounted on a wooden frame with glass. (FOR ELEC. ROOM)
Supply and Installation of Rubber mat 1m x 2m x 3mm. thick to withstand 1.1kV dielectric strength as per IS: 5424 - 1969. (FOR ELEC. ROOM)
Supply and Installation of Rubber gloves of 1.1 KV grade as per IS 4770-68. (FOR ELEC. ROOM)
HI-WALL SPLIT AC UNITS (COOLING ONLY TYPE): Supply, Installation, testing and commissioning of following capacity Hi Wall type split air-conditioning unit suitable to operate between 180-260 volt, 50 Hz, 1 phase power supply, with air-cooled evaporator with coil, fan, and fan motor, air-cooled condenser with hermetically sealed Inverter compressor (with R-410a/R-32/R-407c/R-134a), condenser coil, propeller fans controls, control panel, including control wiring,cordless remote, Necessary supporting arrangement for indoor unit, M.S. frame duly Powder Coated/ Epoxy painted as per approved shade by architect to locate Outdoor Unit with necessary vibration isolation arrangement as per site condition etc. The Unit should be 5 Star rated (on the date of procurements, the minimum EER value of the units should be as per ECBC-2017). The Refrigerant pipe size and gas quantity should suit to the copper pipe length at actual. The capacity guarantee should be ensured by the manufacturer. The provided unit should have inbuilt automatic voltage stabilizer with time delay relay. The unit shall be complete with prefilters section, control panel, with suitable rating of MCB/DP. Note:- Control and power cable will be priced separatley with refrigerant piping item. Notes: a) Civil Work such as wall hole making, wall chisling, refilling of chiseling part with mortar etc as per site condition. b) Nitrogen pressure testing for leakages and flushing during installation and after commissioning between IDU and ODU with flare nuts. c) The Outdoor unit Compressor must be provided with 5 Year Warranty Period. 2.0 TR Nominal Capacity
HI-WALL SPLIT AC UNITS (COOLING ONLY TYPE): Supply, Installation, testing and commissioning of following capacity Hi Wall type split air-conditioning unit suitable to operate between 180-260 volt, 50 Hz, 1 phase power supply, with air-cooled evaporator with coil, fan, and fan motor, air-cooled condenser with hermetically sealed Inverter compressor (with R-410a/R-32/R-407c/R-134a), condenser coil, propeller fans controls, control panel, including control wiring,cordless remote, Necessary supporting arrangement for indoor unit, M.S. frame duly Powder Coated/ Epoxy painted as per approved shade by architect to locate Outdoor Unit with necessary vibration isolation arrangement as per site condition etc. The Unit should be 5 Star rated (on the date of procurements, the minimum EER value of the units should be as per ECBC-2017). The Refrigerant pipe size and gas quantity should suit to the copper pipe length at actual. The capacity guarantee should be ensured by the manufacturer. The provided unit should have inbuilt automatic voltage stabilizer with time delay relay. The unit shall be complete with prefilters section, control panel, with suitable rating of MCB/DP. Note:- Control and power cable will be priced separatley with refrigerant piping item. Notes: a) Civil Work such as wall hole making, wall chisling, refilling of chiseling part with mortar etc as per site condition. b) Nitrogen pressure testing for leakages and flushing during installation and after commissioning between IDU and ODU with flare nuts. c) The Outdoor unit Compressor must be provided with 5 Year Warranty Period. 1.5 TR Nominal Capacity
REFRIGERANT PIPING WITH CABLE: Supply, installation, testing and commissioning including pressure testing as per specifications of copper refrigerant piping complete with all copper fittings for the split units along with connecting control cable and required size of power cable from IDU to ODU. Piping associated with the units to be insulated with 9mm thick closed cell elastomeric nitrile rubber insulation in tubing form as required and finally finished with UV coating. Piping along with connecting cable shall be laid on proper slotted angle trays and cost for the same shall be included. Cost of sealant to be included for sealing all refrigerant sleeves after installation of pipes with insulation and pressure testing. Pair of soft copper refrigerant piping for 2.0TR Hi wall type split unit. Price shall be inclusive of all fittings (elbows, bends, reducers etc.) along control cable, power cable and slotted angle tray.
REFRIGERANT PIPING WITH CABLE: Supply, installation, testing and commissioning including pressure testing as per specifications of copper refrigerant piping complete with all copper fittings for the split units along with connecting control cable and required size of power cable from IDU to ODU. Piping associated with the units to be insulated with 9mm thick closed cell elastomeric nitrile rubber insulation in tubing form as required and finally finished with UV coating. Piping along with connecting cable shall be laid on proper slotted angle trays and cost for the same shall be included. Cost of sealant to be included for sealing all refrigerant sleeves after installation of pipes with insulation and pressure testing. Pair of soft copper refrigerant piping for 1.5TR Hi wall type split unit. Price shall be inclusive of all fittings (elbows, bends, reducers etc.) along control cable, power cable and slotted angle tray.
DRAIN PIPING: Providing and fixing of Hard CPVC drain water piping with fittings, support and insulated with 6mm thick closed cell elastomeric nitrile rubber insulation complete as per specifications. As per specification/ drawings and as directed by Engineer In Charge. 32 mm dia
DRAIN PIPING: Providing and fixing of Hard CPVC drain water piping with fittings, support and insulated with 6mm thick closed cell elastomeric nitrile rubber insulation complete as per specifications. As per specification/ drawings and as directed by Engineer In Charge. 25 mm dia
Bidder Name
Amount
Narender Bhardwaj Contractor (GSTN-06AEIPB2526E1Z3) BID ID -1255488
Rajesh Kumar Batra Contractor (GSTN-06AFJPB2634M1ZI) BID ID -1248371
Dal Singh Atri Contractor (GSTN-06AUIPS1758B2ZM) BID ID -1249366
SANCHIT CREDIT AND CONSTRUCTION PVT LTD (GSTN-06AAACS8917P1ZR) BID ID -1252606
Shailesh Tomar (GSTN-06ACRPT9295M1ZB) BID ID -1251421
DCD ENGINEERING SOLUTIONS PVT LTD (GSTN-NA) BID ID -1252982
Rajesh Kumar Batra Contractor (BID ID -1248371)
Shailesh Tomar (BID ID -1251421)
Dal Singh Atri Contractor (BID ID -1249366)
SANCHIT CREDIT AND CONSTRUCTION PVT LTD (BID ID -1252606)
Narender Bhardwaj Contractor (BID ID -1255488)
Rajesh Kumar Batra Contractor (BID ID -1248371)
Dal Singh Atri Contractor (BID ID -1249366)
SANCHIT CREDIT AND CONSTRUCTION PVT LTD (BID ID -1252606)
Shailesh Tomar (BID ID -1251421)
Narender Bhardwaj Contractor (BID ID -1255488)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .