| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 CrAccepted-AOC COLABA MUMBAI | ₹1.1 Cr | L1 | Accepted-AOC Being lowest |
| 2 | L2₹1.1 Cr+₹2.6 L (2.33%)Rejected-Finance COLABA MUMBAI | ₹1.1 Cr+₹2.6 L (2.33%) | L2 | Rejected-Finance Other than being lowest |
| 3 | L3₹1.2 Cr+₹6.0 L (5.46%)Rejected-Finance PLOT NO 1134 1196 MORIVALI VILLAGE TAL AMBARNATH DIST THANE AMBERNATH 421505 | AMBERNATH | THANE | MAHARASHTRA | 421505 | ₹1.2 Cr+₹6.0 L (5.46%) | L3 | Rejected-Finance Other than being lowest |
| 4 | L4₹1.2 Cr+₹7.4 L (6.75%)Rejected-Finance COLABA MUMBAI | YAVATMAL | MAHARASHTRA | 445001 | ₹1.2 Cr+₹7.4 L (6.75%) | L4 | Rejected-Finance Other than being lowest |
| 5 | Rejected-Technical III 6 7 2ND FLOOR ABOVE BANK OF BARODA GOPINATH BAZAR DELHI CANTT 110 010 | DELHI CANTT | NEW DELHI | DELHI | 110010 | - | - | Rejected-Technical Not Meeting eligibility criteria |
Tender Value
₹1.1 Cr
EMD Value
₹1.9 L
Closing Date
3 Oct 2024, 6:00 pmClosed
CWE (NW) Mumbai
Commander Works Engineer NW Dr Homi Bhabha Road Navy Nagar Colaba Mumbai 05
REPAIR ROUTINE MAINT OF 14 NOS ELECTRIC LIFTS (MAKE THYSSENKRUPP ELEVATOR) OF G14 STOREY BUILDING AND MANNING AND OPERATION OF ELECTRIC LIFTS (ANY MAKE AND CAPACITY) IN G14 STOREY BUILDING IN
2024_MES_668288_1
8220/CWE (NW) Mumbai/E8
Open Tender
Civil Works
Item Rate
330 days
GE (NW) Navy Nagar
Class B
Category c (ii) and d (v)
8 documents required · 8 mandatory
₹1,000
Yes
GE (NW) Navy Nagar
₹1.9 L
15 Nov 2024
31 Aug 2024
5 Oct 2024
31 Aug 2024
3 Oct 2024
21 Sept 2024
31 Aug 2024 - 20 Sept 2024
Amount
Repair/maintenance of lifts including carrying out daily check and periodical services of fully automatic electrical lift with power operated door, simplex collective control system with repair/ maintenance of unserviceable damaged parts such as bearings, bushes, all type of guide shoes, headers, hangers, door ropes,door cards, car door sills, landing door sills, door locks, control cards, and its contacts, hall push buttons and its spares, connector/links, welding of cracked/broken and MS parts, Landing operating Panel of any size and capacity, repairs /maint of u/s damaged door safety edge and sensor mechanical safety lock, magnetic lock or contact, car position indicator, and all connected accessories, necessary wiring of hall push button assembly, repair/maintenance of broken COP/LOP buttons and display, including cover, Fire alarm, Firemen button glass, Intercom, alarm /hooters, Maintenance of damaged hand rail, Shaft, light/switches, complete with illuminated push button and direction indicator with LED display with LPT/LPC card of stainless steel inclusive of harness wiring for laminating of push button of each floors and cutting wall making good disturbed surface with masonry work to make with existing surface & cable as per requirement for safe operation of lifts , fixing of loose rail bracket with necessary masonry work ,cabin, minor repair of cabin light, shaft light and minor repair of cabin fan , ensuring safe and smooth functioning of lift and complete maint of car top, binding of loose wire at control panel and rust painting at car top and door and allied parts with testing, two coats of Painting of Gear motor, all MS channels and Control panels using spray gun complete, dewatering of lift wells in case of any emergency arises all as directed by Engineer-in-Charge. for the following lifts
8 Ps lift (544 Kgs) ( G+6/ 14 Storey) in bldg R-12, (Thyssenkrupp),( Total - 01 Lift)
13 Ps Lift ( 884 Kg) (G+ 6/14 storey) in NKG ,R-9,R-10,R-15,R-16,R-20,R-21,R-24&R-27 bldg, R- 39 E & E Wing ( Thyssenkrupp) ( Total- 10 Nos lift)
Goods lift ( 2000 Kg)(G+14 Storey) in bldg R-16, R-20 & R-21 ( Total 03 Nos Lift)
Notes : - (i) The Contractor has to carry out the AMC of the Lifts through OEM (OTIS) only for which he will enter an agreement with OEM (ii) The AMC should cover any/all parts of Lifts if its fucntions found defective the same should be repaired or replaced by the OEM as per the timeline covered under norms. (iii) Rewinding of motor if required will be done by the contractor and no extra cost will be given by the department. (iv) The detailed duty mechanics of the firm shall report to the JE Concerned at the Lift complaint cell i.e. R-12 building . New Navy Nagar for receiving the complaints at round the clock daily including sunday and holiday. (v) The detailed lift mechanics shall sign ( Their shift wise) in the attendence register kept with lift cell.
Disconnecting and taking out unserviceable COP assembly for G+5/G+14 storey building, supply and fixing new car operating panel assembly completed with illuminated push button for floor position alarm, non stop door open , door close, cabin fan, cabin light stop, attend out key etc with direction indicator,with LED displey with CPI card of stainless steel face plate in and including necessary wiring for laminating push button of each floors and cutting wall, making good disturbed surface with machinary work to complete all as specified and directed by Engineer-in-charge.
Taking down old unserviceable cabin fan from car cabin and supply and fixing new cabin fan non oscillating type axial flow, single speed 300mm sweep, 240 volts ISI mark with grill complete all as directed by Engineer-in-charge.
Replacement of automatic door drive unit without motor on car top with VVVF of 1 HP capaicity all as specified and directed by Engineer-in-Charge.
Dismantling and taking out unserviceable safety edge of any type supply and fixing full beam infrared sensor upto full length of car doors (2.00 mtr) for (6 Ps),& (8 Ps) complete all as specified and directed by the Engineer-in-Charge.
Dismantling and taking out unserviceable old landing push button box alongwith illuminated call button with control wiring supply and fixing landing push button box alongwith illuminated call button with control wiring for G+14 storey building complete all as directed by Engineer-in-charge
Disconnecting and taking out old/unserviceable Governor rope of size 8 mm dia(8/19 Construction) ungalvanised including necessary connection with pulley in machine room and shaft pit complete with clamps, nuts bolts, and washers etc, for high rise building for 8/13/Goods lifts complete all as specified and directed by Engr-in-Charge.
Supply and fixing in repair Emergency alarm with complete accessories alongwith box including connecting cables for G+14 storey building all as specified and directed by Engr-in-Charge.
Disconnecting and taking out unserviceable ARD and repair of ARD for proper operation including necessary wiring with machine and controller consisting of the following :-
Replacement of PCB Card, relay with control wiring for G+14 storey building.
Replacement of sealed maintenance free batteries ( Set of Four) each of 12 volts, 18 AH (Maintenance free)
Taking down old unserviceable OSG Pully from the position and supply and fixing New OSG Pulley both top and bottom for 08 PS /13 PS /Goods Lift as specified and directed by Engr-in-Charge.
Taking down old unserviceable Chequred plate and supply and fixing Aluminimum Chequered plate of 5mm thick duly fixed with nuts, bolts, washers,screws and covers with aluminimum angles section of size ( 40x40x4 mm thick) on corner of cabin in and including platform base of 10mm thick plywood of 08 Ps/13 Ps/Goods lifts
Dismatling and taking out unserviceable old control panel and control wiring and supply and fixing new CAN BAS Integrated Drive based collective control panel in hinged MS powder coated cabinet with control wiring comprising with multiple microcontrolled programmed chip based controlled by pulse modulation, complete with all safeties such as thermal overload protection, over current protection, auto phase reverse link to each other in net work and compitable to 18 KW/24HP capacity VVVF drive including proper connection with proper lugs, terminal connectors screws and motor connection with galvanised sheet trunking 24 SWG including wiring of main motor with suitable size of stranded copper cable etc complete all as specified and directed by Engineer-in-Charge.
Disconnecting and taking out old/unserviceable shaft wiring, supply and fixing of shaft wiring in hoist way upto lower limit with PVC insulated copper conductor cable single core, 1100 Volts grade 0.75 Sqmm 24 Nos single core & 1.0 Sqmm for earth wire duly bunched with wire binding locking strip, drawing through in and including galvanished sheet metal trucking of 24 SWG up to ground floor in hoist for control to all function including in built connection for control panel, PCB, Hall push button, fire switch and lower limit switch all as specified and directed by the Engineer-in-Charge. for G+14 Storey building.
Disconnecting and taking out defective dynamic breaking resistence from controller and supply and fixing new aluminium covered wire wound dynamic breaking resistor to absorb the reverse energy dissipation of motor during regeneration in control operation suitable for 11.0KW/15HP motor.
Taking down old unserviceable Announcement system and supply and install, testing and commissioning of MP3 voice announcement system in the controller and high quality speaker on car top, with necessery provision of shaft wires and travelling cable complete as specified. The audio indicator shall announce floor position, ARD made operation, overload announcement etc and continious mild music in hindi and can be programmable for more music. The announcement system shall be in hindi and english.
Disconnecting and taking out defective unserviceable main drive (any type) from existing control panel and supply and fixing CAN BAS Integrtaed drive suitable for Goods/13 Ps lift G+14 storey building complete with all electric connection.
Taking down old/unserviceable main pulley from motor and supply and fix of main pulley of 4/5/6 grooves suitable for existing motor and fixing of existing rope complete as specified and directed by Engineer-in-Charge.
Replacement of unserviceable ARD control system and commissioning and testing of new ARD system suitable for upto 15/18 KW motor including wiring with connected items in existing G+14 Storey building 8 ps/ 13 ps/ Goods lifts 415V,50 Hz,3 phase with a speed of 1.2 mtr/sec comprising with maintenance free battery 12 V, 18 AH (04 Nos Maintenance free battery, Make Exide/Amaron) to match with the existing capacity motor and controller system complete all as specified and directed by Engineer-in-Charge.
Taking down old unserviceable main steel wire rope after disconnecting old wire rope from counter weight, pulley and car cabin and supply and fix new main steel wire rope 13 mm dia, ungalvanised, 8/19 construction in and including necessary connection with counter weight, pulley and car cabin with clamps, nut, bolts and washers etc complete all as directed by Engineer-in-Charge.in 6/13 /Goods Lift, G+5/G+6/G+16 Storey buildings.
Material and Labour for 18mm thick mirror polished black granite slab, machine cut mirror polished cladding with chamfered/rounded edges approved decorative design including 20 mm thick screed bed or backing coat 15 mm thick in CM (1:4) and pointed in white cement mixed with pigement to match with shade of granite for lifts architrave at all floors complete all as specified and directed by Engr-in-charge.
Breaking, chipping, cleaning of the existing surface of lift pits and repair to concrete cracks after opening in V groove and filling with PMM (1:3) admixed with Shalicrete. Injection grouting to be done at 30 cm c/c with cement slurry admixed ShaliGrout IP @ 1kg per 50kg bag of cement (STP Ltd or eqnt). Application of primer & 2 coats of ShaliCem-EWP as per methodology and as per manufacture instruction and making the lift well completely seepage and dampness free complete all as specified and directed by Engr-in-Charge.
Manning & operation of electrically operated lifts (6Ps,8 Ps & 13Ps) per Bldg, of existing make and capacity daily 8 hrs in one shifts from 0600hrs to 1400hrs, including cleaning, taking care of entire lift installation from any pilferage, theft or damage etc complete all as directed by Engineer-in-Charge for R-20, R-23, R-28, R-29 R-36,R-37, R-38, R-39, 200 sailors, AQ, AR, F1 and G building for lift attendent (semi skilled) (11 Months) (1x13x11= 143 )
Note for item no 23 :- (i) Passes will be processed alongwith (after verification on signed certificate, Pass shall not be granted without submission of qualification proof & experience certificate for lift operator. In case of OEM, the qualification mentioned in note is not applicable which shall be verified by Engineer-in-Charge before issue of passes (ii) Contractor shall submit ID proof, Residential proof, Bank A/C details to department and obtain approval of Engineer-in-Charge before employing a person as Operator (iii) Payment to employees shall be done by crossed cheque through Aadhaar linked bank account only and it shall not be less than minimum fair wages as per act in vogue. The contractor shall submit proof to Engineer-in-Charge before claiming any payment. (iv) Lift attendent (semi skilled) shall be available with lift cell as per the shift timings specified in the tender and he will report to JE E/M in-Charge or Lift Cell in-Charge. In case of emergency he will function according to their direction. If he is found absent or move without intimating to in-Charge of Lift Cell or JE E/M he will be treated as absent for the said shift and recovery to this effect for Rs 1500/- per shift shall be affected. (v) Payment as per quoted rate shall also be deducted in addition to the penalty as specified above. (vi) In case of malfunctioning if any noticed, lift operator shall intimate to the lift cell. (vii) In case of any necessity for rescue operation or accident, Rescue Operator shall be capable of rescue the passenger and reacting to the situation (accident etc) Rescue operator engaged for rescue operation shall immediate attend the complaint within 30 minutes failing which penalty at Rs 500/- per hour or part thereof shall be levied (viii) Contractor shall submit the labour licence as applicable as per latest laws/acts & Copy of GST Regn registered number issued by concerned authority. (ix) Insurance coverage, compensation if any applicable or necessitated due to mis operation of lift shall be the responsibility of contractor. The quantum of compensation shall be assessed based on the BOO composing of Lift Inspector of Maharashtra State, representatives of both agencies carrying out M&O works and routine maintenance work of lift and members from department. (x) Contractor has to submit proof of payment of EPF subscription made by him as applicable as per latest laws/acts alongwith RAR failing which RAR will not be progressed for payment. (xi) The rates quoted shall be inclusive of suitable reliver wherever sundays & holidays are mentioned for working
xii) The bidders are advised not to quote rate less than minimum fair wages as circulated by competent authority. If the quoted amount is less than the estimated cost as given Page No 15 of Sch of Notes, the lowest bidder will have to deposit FDR/BGB as elaborated herein after in favour of Accepting Officer within 07 days of opening of financial bid. (xiii). The deposited amount shall be the difference between estimated cost as given Page No 15 of Sch of Notes and amount quoted by lowest bidder for respective item. FDR/BGB shall be released only after satisfactory completion of work. If the contractor fails to pay minimum wages to employees, the department shall have right to withhold the said amount which will be verified by GE. The decision of Accepting Officer regarding amount to be withhold shall be final and binding. The withhold amount will be utilised by GE for payment to employees if contractor fails to pay minimum wages and balance amount if any shall only be released. If the lowest bidder fails to deposit the amount as stated above within 07 days, the contractor shall be banned for 06 months & his bid shall be rejected.
Monarch Enterprises (BID ID -3111522)
shakti engineering and electrical works (BID ID -3108742)
Escon Elevators Pvt Ltd (BID ID -3107585)
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .