Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.3 CrAccepted-AOC | ₹38.3 Cr Quoted ₹39.1 Cr | L1 | Accepted-AOC BEING LOWEST TENDER |
| 2 | L2₹39.9 CrRejected-Finance C 2488 SUSHANT LOK PHASE 1 GURGAON 122001 HARYANA | GURUGRAM | HARYANA | 122001 | ₹39.9 Cr | L2 | Rejected-Finance HIGHER THAN LOWEST TENDER |
| 3 | L3₹40.3 CrRejected-Finance 11 JAMES HICKEY SARANI FORMALLY KNOWN AS DACRES LANE 2ND FLOOR KOLKATA 700069 | KOLKATA | KOLKATA | WEST BENGAL | 700069 | ₹40.3 Cr | L3 | Rejected-Finance HIGHER THAN LOWEST TENDER |
| 4 | L4₹40.4 CrRejected-Finance | ₹40.4 Cr | L4 | Rejected-Finance HIGHER THAN LOWEST TENDER |
| 5 | L5₹40.5 CrRejected-Finance 3A RAM MOHAN MULICK GARDEN LANE UNIT NO 6A 3RD FLOOR KOLKATA 700010 | KOLKATA | WEST BENGAL | 700010 | ₹40.5 Cr | L5 | Rejected-Finance HIGHER THAN LOWEST TENDER |
Tender Value
₹35 Cr
EMD Value
₹20.8 L
Closing Date
4 Nov 2023, 6:00 pmClosed
BRIG SUSHIL KUMAR CHIEF ENGINEER
HQ CHIEF ENGINEER KOLKATA ZONE MILITARY ENGINEER SERVICES BALLYGUNGE MAIDAN CAMP GURUSADAY ROAD KOLKATA 700019
COMPLETION OF INCOMPLETE WORK FOR CONSTRUCTION OF MD ACCN AT NABAGRAM PHASE I UNDER GE PROJECT KOLKATA
2023_MES_617532_1
89080/E8
Open Tender
Civil Works
540 days
Kolkata
Please refer Tender documents.
8 documents required · 8 mandatory
₹3,000
Yes
GE (P) Kolkata
₹20.8 L
Yes
30 Dec 2023
6 Sept 2023
8 Nov 2023
6 Sept 2023
4 Nov 2023
18 Oct 2023
Amount
Sch 'A' Part -I (Building Works) Note:- This Sch is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col 5 signifies this fact only.
Completion of incomplete officer married accomodation (Block No. 01) for four Nos officer (one block of G+1) with all fittings & fixtures etc. Complete all as specified and shown on drawings
Completion of incomplete officer married accomodation (Block No. 02) for four Nos officer (one block of G+1) with all fittings & fixtures etc. Complete all as specified and shown on drawings
Completion of incomplete officer married accomodation (Block No. 03) for four Nos officer (one block of G+1) with all fittings & fixtures etc. Complete all as specified and shown on drawings
Completion of incomplete officer married accomodation (Block No. 04) for four Nos officer (one block of G+1) with all fittings & fixtures etc. Complete all as specified and shown on drawings
Completion of incomplete officer married accomodation (Block No. 05) for four Nos officer (one block of G+1) with all fittings & fixtures etc. Complete all as specified and shown on drawings
Completion of incomplete JCOs married accomodation (Block No. 01)for fourteen Nos JCOs(one block of G+3) with all fittings & fixtures etc. Complete all as specified and shown on drawings
Completion of incomplete JCOs married accomodation (Block No. 02)for fourteen Nos JCOs(one block of G+3) with all fittings & fixtures etc. Complete all as specified and shown on drawings
Completion of incomplete ORs married accomodation (Block No.01) for fourteen Nos ROs(one block of G+3) with all fittings & fixtures etc. Complete all as specified and shown on drawings
Completion of incomplete ORs married accomodation (Block No.02) for fourteen Nos ROs(one block of G+3) with all fittings & fixtures etc. Complete all as specified and shown on drawings
Completion of incomplete ORs married accomodation (Block No.03) for fourteen Nos ROs(one block of G+3) with all fittings & fixtures etc. Complete all as specified and shown on drawings
Completion of incomplete ORs married accomodation (Block No.04) for fourteen Nos ROs(one block of G+3) with all fittings & fixtures etc. Complete all as specified and shown on drawings
Completion of incomplete ORs married accomodation (Block No.05) for fourteen Nos ROs(one block of G+3) with all fittings & fixtures etc. Complete all as specified and shown on drawings
Construction of a RCC under ground sump of capacity 230000 liters with all inlet , outlet and washing outlet with necessary valves, fittings and fixture etc complete all as specified and as shown on drawing
Lumpsum price worked out by the tenderer/ bidder for SITE CLEARENCE, AREA DEVELOPMENT, EARTH WORK AND EXCAVATION as listed in Schedule ‘A’ Part-II on Serial Page No. 43
Lumpsum price worked out by the tenderer/ bidder for INTERNAL ELECTRIFICATION as listed in Schedule ‘A’ Part-III on Serial Page No. 48(C)
Lumpsum price worked out by the tenderer/ bidder for INTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-IV on Serial Page No. 50(R)
Lumpsum price worked out by the tenderer/ bidder for ROAD/ PATH/ CULVERT as listed in Schedule ‘A’ Part-V on Serial Page No. 55(R)
Lumpsum price worked out by the tenderer/ bidder for AREA DRAINAGE as listed in Schedule ‘A’ Part-VI on Serial Page No. 57
Lumpsum price worked out by the tenderer/ bidder for SEWAGE DISPOSAL as listed in Schedule ‘A’ Part-VII on Serial Page No. 60(R)
Lumpsum price worked out by the tenderer/ bidder for SECURITY FENCING AND GATE as listed in Schedule ‘A’ Part-VIII on Serial Page No. 65(R)
Lumpsum price worked out by the tenderer/ bidder for EXTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-IX on Serial Page No. 66.
Lumpsum price worked out by the tenderer/ bidder for EXTERNAL ELECTRIC SUPPLY as listed in Schedule ‘A’ Part-X on Serial Page No. 74(R)
Lumpsum price worked out by the tenderer/ bidder for LIGHTENING PROTECTION as listed in Schedule ‘A’ Part-XI on Serial Page No.77
Lumpsum price worked out by the tenderer/ bidder for RECHARGE PIT alongwith DESEILTING CHAMBERas listed in Schedule ‘A’ Part-XII on Serial Page No.83.
Lumpsum price worked out by the tenderer/ bidder for GARBAGE BIN as listed in Schedule ‘A’ Part-XIII on Serial Page No. 86.
Schedule ‘A’ Part-XVI (MISCELLANEOUS ITEMS) Note : This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col. 5 signifies this fact only.
M & L for mixing of Fly ash, Clinker & stone dust in proportion of 1:3:6 ( i .e 10 % Fly ash, 30% Clinker and 60% Stone dust) laying , watering , ramming and compacting with vibratory roller to get min CBR value 8% and Dry density 97 % placed at required camber and gradient complete as directed .Note:Break down details of this Items is shown in Annexure ‘B’ in Schedule ‘A’ Notes.
Road / Path M&L and laying 150 mm thick (compacted thickness) wet mix macadam (WMM) (laid in two layers of 75mm thick) with crushed stone aggragate of specified grading, spread using mechanical paver as specified, watered, rolled and consolidated as per required greadeant and camber complate all as specified & directed.
M&L for cleaning and preparing the road surface and making good for road marking applying reflective thermoplastic white road marking paint (HOT APPLICATION) comforming to BIS 3262 laid down through modern propelled road marking machine in a layer of CRYSTALEX and use of all ingredients such as binder, glass, beads, titanium dioxide, calcium carbonate, interfiller thermoplastic required for glass beads per square meter by incorporating the white glass beads for reflectivity in 100mm width complete all as specified and as directed. Make of Thermoplastic Road marking paint/Retro-Reflective paint - M/s Asian Apcomark, M/s STP or M/s Shalimar Paints Ltd or M/s Berger Paints Ltd, M/s Jhonson & Nicholson Paints Ltd or M/s Jotun India Pvt Ltd.
S & F cat eye size 100 x 90x18mm of polycarbonate lens exclusively on micro onsmatic lens technology ot be fixed with screws or pasted with eposy resin based adhesive after cleaning the surface complete all as specified and directed
S & F for sparking solar road studs with body made of aluminium dia cast matt finished with anti twist ribs on the bottom anchor or size opprox 125mm x 90mm and solar battery 12V with automatic dusk to dawn solar suit all as specified and directed.
Recharge Pit S & F 150 MM perforated UPVC pipe with 20% Perforation complete all as specified and directed.
S & F 150mm bore PVC (SWR) vent cowl complete all as specified and directed.
M&L for hand packed gravel (Stone chips 12.50mm) for filling in bore holes and inside of recharge pit complete all as specified and directed.
External Electrification Design, Supply , Installation, testing and commissioning of Compact Secondary Substation (CSS) comprising to following sub systems and meeting following specification and parameters:- (a) Sheet steel housing 1.6 mm thick with corrosion resistance and all side openable hinged door and lock and key arrangements.(b) Steel parts are tested as per IS 6988 (c ) Engineered for smooth air flow for natural cooling .(d) No direct access to high voltage parts. (e) GI strip earthing for all LV and HV requirements as per laid down policy (f) Separation steel sheet wall for RMU/Transformer /LT panel. (g) Heave lifting lugs with all equipments load. (h) Slopped roof (j) Necessary danger plates outside of the CSS. (k) Necessary HT and LT cable/Earth strips opening.(l) Non extensible type CCV RMU with 2 isolator & 1 No VCB for 500 KVA 11 KV/0.433 KV Dry Type Transformer,(m) One metering module (CVCM) with necessary CTs and PT comprising the following( Complete unit is to be installed inside CSS with all protection accessories ) Enclosure : Metal Clad, IP-54 Protection , Protection Relay : Self Powered Alfa neumaric LCD display type. Internal arc tested for 1 sec, fully compartmentalized sheet steel enclouser with automatic safety shutters, GI foundation bolts with provision of cable terminating facialities with
powder coated smooth glossy finish and as per follows:-(i) Rated voltage -12 KV (ii) Rated Frequency- 50 Hz. (iii) Rated continuous current rating - 630 Amps. (iv) Rated Interrupting Current -21 KA (V) Rated making current for VCBs-52 KA. (vi) Rated making current for isolators-62 KA (vii) Rated short time current for 3 sec- 26.3 KA. (viii) Operating duty-0-0.3 sec- CO 3 min -CO (ix) Power frequency with stand voltage - 28 KV. (x) Impulse withstand voltage -75 KV (xi) Busbar rating -120% of continuous current (xii) Operation : spring clossing mechanism -DC motor operated with 25 volt supply , Breaker Closing - Manual & Electrical through TNC switch (xii) Shunt trip coil- 24 V DC.(xiv) Safety Interlock Locking facility Required(xv) Breaker panel Indication -ON(RED) OFF (Green). (xvi) Accessories: Mechanical counter, space heater with thermostat, Fuse and ON/OFF Switch, Aux relays for remote trip/indication for PC interface etc, cubical illumination lamp LED 9 Watt retrofit type 230 V AC, T-N switch, Anti pumping contractor etc. (xvii) Mimic diagram : An operating mimic diagram shall be provided on the front side of each cubical (xvii) Note:- Circuit breaker complter will be obtained directly from the OEM and not from the authorised system assemblers of OEM. The installations, calibration and testing of SF-6 circuit breakers will be conducted in the presence of authorised representative of OEM by the contractor .
(xix) Battery bank with charger for RMU is included in the item rate and rating of battery as described by OEM.(m) Transformer 500 KVA copper wounded dry rasine cast distribution type 11 KV/433 V, 3 Phase, 4 wire LT output, 50 HZ, AN, Dn11, suitable for indoor installation. with off load tap changer with steps +- 2.5% upto +-7.5 % on HT side all technical specification comprising to IS 180 ( Part-I & Part-II) with all necessary standard fittings and accessories complete after necessary testing after completion with the following specification:-(i) Standard KVA rating -500 KVA . (ii) Primary Voltage:- 11 KV AC. (iii) Secondary Voltage:- 433 V AC. (iv) Nutral earthing should be solidly earthing system (v) Frequency:- 50 Hz with +-3% tollarence (vi) Vector Group:- DYn11. (vii) Percentage impedence:- 5% at 75 deg C ( subject to IS tolerance). (viii) Average temperature rise shall not exceed to 65 deg C and max temperature rise of the windings shall not exceed to 115 DegC.(ix) The core shall be of high grade Cold Rolled Grain oriented (CRGO) annealed steel lamination , having low loss and good grain properties , coated with "F" class grade insulations, bolted together firmly to the frames to prevent vibrations and noise ..(x) HV and LV coils should be with electrolytic copper windings with "F" class grade insulation on HV windings and necessary spacers and air duct for cooling (xi) The losses at the rated voltage should be within the specified limit as per IS-1180 (xii) The transformer enclouser should be with robust construction and shall be built of electrical welded MS sheet wire mesh or perforated sheet for ventilation, with lifting lugs, pulling lugs, top cover fixing bolts, rollers and enclosure base channels.
Supply , install, testing and commissioning of LT panel board outdoor type, as per norms of CPRI (CPRI approved), platform mounted factory made, totally enclosed dust and vermin proof openable from both front and rear side made out of 3.15 thick CRCA MS Sheet and built upon suitable size angle iron frame work , having front and rear hinged doors, lifting lugs (2 Nos) , earthing strips at rear side , bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts , spring and washers. The cabinet and all members should be chemically treated with MSR solution for anticorrosive treatment and apply spray paint with two coat of synthetic enamel paint over a coat of red oxide primer. The panel should be suitable for 415 volts , 50Hz , 3 phase 4 wire system and internal connection should be provided with copper strips of suitable size and necessary foundation work and comprising following:- (ORs Accn) (a) Bus bar 630 A, 50 KA breaking capacity, IP 54, 04 Nos and accessories. (b) INCOMING MCCB, 4 pole, 400 Amps, 415 Volt AC, 36 KA rupturing capacity-01 No. (c) Ougoing MCCB, 4 pole, 125 Amps, 415 Volt AC, 25 KA rupturing capacity --05 Nos. (d) OUTGOING MCB TPN 32 Amps, 10 kA, 'C' series, 415 volts--02 Nos. (e) Time switches 415 V three Phase of 20 Amp rating with contactor--01 No. (f) Metering and accessories Parameter V,A, F,PF,KW,KVA,KWH with suitable CT ( MFM 4410LCD meter CI 0.2S with RS485)
Supply , install, testing and commissioning of LT panel board outdoor type, (CPRI approved), platform mounted factory made, totally enclosed dust and vermin proof openable from both front and rear side made out of 3.15 thick CRCA MS Sheet and built upon suitable size angle iron frame work, having front and rear hinged doors, lifting lugs (2 Nos) , earthing strips at rear side , bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts , spring and washers. The cabinet and all members should be chemically treated with MSR solution for anticorrosive treatment and apply spray paint with two coat of synethetic enamel paint over a coat of red oxide primer. The panel should be suitable for 415 volts , 50Hz , 3 phase 4 wire system and internal connection should be provided with copper strips of suitable size and necessary foundation work and comprising following:- ( Offs Accn) (a) Bus bar 800 A, 50 KA breaking capacity, IP 54, 04 Nos and accessories. (b) INCOMING MCCB, 4 pole, 500 Amps, 415 Volt AC, 36 KA rupturing capacity --01 No. (c) Ougoing MCCB, 4 pole, 160 Amps, 415 Volt AC, 25 KA rupturing capacity --05 Nos. (d) Metering and accessories Parameter V,A, F,PF,KW,KVA,KWH with suitable CT ( MFM 4410LCD meter CI 0.2S with RS485)
Supply , install, testing and commissioning of LT panel board outdoor type, (CPRI approved), platform mounted factory made, totally enclosed dust and vermin proof openable from both front and rear side made out of 3.15 thick CRCA MS Sheet and built upon suitable size angle iron frame work , having front and rear hinged doors, lifting lugs (2 Nos) , earthing strips at rear side , bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts , spring and washers. The cabinet and all members should be chemically treated with MSR solution for anticorrosive treatment and apply spray paint with two coat of synthetic enamel paint over a coat of red oxide primer. The panel should be suitable for 415 volts , 50Hz , 3 phase 4 wire system and internal connection should be provided with copper strips of suitable size and necessary foundation work and comprising following:- ( JCO Accn) (a) Bus bar 300 A, 50 KA breaking capacity, IP 54, 04 Nos and accessories. (b) INCOMING MCCB, 4 pole, 200 Amps, 415 Volt AC, 36 KA rupturing capacity-01 No. (c) Outgoing MCCB, 4 pole, 160 Amps, 415 Volt AC, 25 KA rupturing capacity --02 Nos. (d) Metering and accessories Parameter V,A, F,PF,KW,KVA,KWH with suitable CT ( MFM 4410LCD meter CI 0.2S with RS485)
Supply and installed testing and commissioning outdoor type APFC bank panel, MDXL offered heavy duty Mixed By electric type box capacitor with 7% aluminium wound reactor , unit tested in accordance with IS 13340-1993/IS 13341-1992 ,IEC 60831 part 1&2 with thyrister control module with aluminium heat shink with semi conductor fuses, smooth switching on and off automatically at +10 volts, compartmental design dust and vermine proof suitable for three phase, 4 wire 440 volt made out of 3.15 mm thick CRCA sheet with build upon rigid frame work, cubical type , heavy duty powder coated RAL 7035, capacity 250 KVAR with 12 stage (10x4+15x2+25x4+40x2) with incoming 400 A 4 P 35 kA MCCB capacitor bank having following accessories including control wiring with HR FR/FRLS copper wire complete all as specified and directed as follows:- (01 Job) (a) To with stand on Non Linier load upto 40% (b) 2.5 In Over current with stand (c) 10000/year switching capacity (d) 1,60,000 hours fife expectancy(e) Capacitor ,MCB,MCCB ,Contactors, APFC Relay will be same make complete all as specified.
Supply and fixing LED street light fittings on poles all as conforming to the following street light fitting- (a) System watt/lumens:- Max 60 watts/total system lumen not less than 3600 lm (b) Housing:- High pressure die cast aluminium (c) IP Rating :-IP 65 (d) Front cover :- Toughened Clear Glass (e) mounting :- Suitable for pole mounting with bracket arm 40-50 mm dia Mounting height (f) Finish: Epoxy powder coated with any additional treatment for smooth and anti (g) Lamp :- High bright LED with Lens (h) System Efficiancy (lm/W) of the luminaries:- not less than 100 lm/watt (j) Colour temperature(k) :- not less than 5700 (k) Colour Rendering Index (CRI): - Not less than 74 (l) Life:- Not less than 50000 Hrs of operation (m) Optics :- Spread ( beam angle along the driveway)-120 degree throughbeam angle (n) Control Gear :- inbuilt electronic driver with APFC, PF not less than 0.90 and THD (o) Surge protection:- inbuilt surge vprotection minimum 5 KV (p) Heat Shink :- As per OEM 's Design (q) (a) Bidder has to compulsorily submit the LM -79 and LM-80 and third party Make:- Philips/Havells/Bajaj/Wipro/GE Lighting/Crompton
Supply and fix outdoor type cable junction box made of PVC complete with knockout for cable entry and 04 nos connectors, and 01 no 5 A SP MCB complete all as specified and directed. Make Hensel, Model No KF1616B/equivalent make as specified in Appx "D"
M&L for street light bracket 1.5 mtr made with 40 mm dia medium grade GI Pipe with 300 mm dia and 380 mm length pole top MS cover complete with one coat of primer and two coats of synthetic enamel paint up to 1.5 M m length complete all as specified and directed.
Supply and fixed of Solar street light with in built charger controller (PWM) 12.8V 27Ah, charger battery from solar panel, Protects battery from over charging/over discharging, protects panel from reverse current , including 7 mtr pole with suitable fixture and LED lamp 40 Watt complete all as specified and directed. Make: Crompton; Cat No: CSADSMP40CDLor equivalent in Bajaj /Tata BP, Havells.
WATER SUPPLY Drilling trail Bore of suitable diameter with reverse rotary circulation or direct circulation method or combination of both by using power rig for housing of 250 mm nominal bore reduced to 200mm below ground level in any kind of soil strata including hard stone/ boulder etc. complete all as specified and directed.
Reaming upto 525 mm upto 60 metre form ground level for insertion of casing pipe 250 mm bore complete all as specified and directed.
Reaming upto 525 mm exceeding 60 metre but not exceeding 90 metre from ground level for insertion of casing pipe/ strainer 200 mm bore complete all as specified and directed.
Supply and fixing of Ball plug having 3.00 metre length and suitable for 200 mm bore casing pipes complete all as specified and directed.
Supply, lowering and fixing in position 250 mm nominal bore ERW heavy duty MS casing pipe of 8 mm wall thickness and welding joints with MS coupler ring around the pipes with MS flat iron 50 mm x 6 mm complete as specified and directed. Make:Jindal/Tata/Bansal
Supply, lowering and fixing in position 200 mm nominal bore ERW heavy duty MS casing pipe of 8 mm wall thickness and welding joints with MS coupler ring around the pipes with MS flat iron 50 mm x 6 mm complete as specified and directed. Make:Jindal/Tata/Bansal
Supply, lowering and fixing in position 200 mm bore, low carbon galvanized (LCG) strainer “V” wired type of 7 mm thickness with 1 mm continuous lot to offer not less than 56 % open area, beveled end, but jointed and welded in suitable length with MS flat iron 50 mm x 6 mm coupler ring all around the pipe, Complete all as specified and directed.
Supply, lowering and fixing in position MS reducing socket 250 mm x 200 mm nominal bore, 8 mm thick and properly welded to pipe with MS flat iron 50 mm x 6 mm coupler ring all as specifiec and directed.
Supply and fixing, 80mm bore galvanized steel tubing medium grade, 6.00 metre long in twin arrangements as in gravel filling arrangement to bore well fixed5 metre below ground level and 1 metre above ground level, inclined at an angle of 40 degree from horizontal plane of ground, complete all as specified and directed . Note:- PCC foundation block for the pipes will be measured and paid separately under respective items in this schedule.
Supply pouring and packing pea-gravel of size 3 mm to 8 mm and packed all around the entire bore well to fill in the annular space between pipe assembly and bore hole, complete all as specified and directed.
Material and labour for development of tube well with compressed air and after with 25% extra copacity pump by pumping muddy water complete all as specified and as directed.
Material and labour for Yield test for bore well by continuously pimping for 16 hrs to determine sate pumping yield, complete all as specified and directed.
Supply, fixing and lowering 100mm bore MS column pipe (seamless) both end flanged 3.00 metre long, fitted with flanges at both ends made out of heavy grade pipes of not less than 5.4 mm wall thickness ISI marked (IS: 1239 Part-1) complete with bolts, nuts, gaskets etc, as required complete all as specified and directed.
Supply, fixing mild steel wire chains with dia of links 10mm, for securing submersible pump set, complete all as specified and directed.
Supply and fixing well cap made out of 5mm thick MS plate with provision of suitable holes for passing two runs of flat three core, PVC insulted industrial cable for submersible motor, 10 sq mm and suitable for fixing 250 mm nominal bore ERW heavy duty MS casing pipe of 8 mm wall thickness, complete all as specified and directed.
Supply and installed sample box for displaying samples for strata made out of teak wood plants 25 mm thick board of size (outer size of box) 1000mm x 1000mm provided with sample box (inside) of sizes 100mmx100mmx100mm complete all as specified and directed.
Electro lighting test with using suitable equipments for the bore hole before lowering of pipes and strainers for assessing proper delineation of water complete all as directed.
Testing bore wall raw water for all parameters, chemicals, bacteriological and arsenic aspect from any Govt approved recommended laboratory complete all as directed.
M&L for Bore Well water filled submersible pump set,18 WHP, 3 Ph, 50 Hz, 415V AC, with high operational efficiency, performance and durability, wide voltage range, super finished water lubricated bush bearings, an inbuilt sand flushing system combined with a specially designed NRV, dynamically balanced rotating parts, CED coated components, with less speed drop motors with Teflon bearing and sand guard comprising with the following requirements: (a) Head: - 55 M (b) Discharge: - 11.8 Ltrs per second/708 Ltrs per minute (c) Outlet discharge pipe dia: -100mm (d) Voltage range: - 350 to 440V AC, 50 Hz (e) Pump Bowl, suction and delivery:- made with Cast iron, C.I.FG-200 Grade (f) Motor and pump Bushes: - Lead Tin Bronze alloy, with LTB-2/LTB-4 grade (g) Motor and pump shaft: - SS-410 (h) mpeller: - Noryl/Stainless steel, with 20 percent glass filled/cast steel SS-410 grade (j) Finish Rotor: - Copper steel with EC grade +M47 grade (k) Thrust bearing: - Carbon + SS with Graphite Carbon + SS-420 grade (l) Pump Bushes: -NRB-Nitrile Butadiene Rubber (m) Sleeve plating: - SS-410 with hard chrome (n) Motor Body: - Stainless Steel- AISI-304 grade Note: - The flow (LPS) and head of the pump set may vary based on Yield test of the Deep Tube/Bore Well. No price adjustment shall be carried out in case WHP of the pump is varying by ±10%. In case the variation of the WHP is more than ±10% the price adjustment shall be carried out based on WHP on Pro Rata basis
M&L for Open Well water filled submersible pump set, 12 WHP ,3 Ph, 50 Hz, 415V AC, with high operational efficiency, performance and durability, wide voltage range, super finished water lubricated bush bearings, dynamically balanced rotating parts, CED coated components, with less speed drop motors with Teflon bearing comprising with the following requirements: - (02 Nos) (a) Head: - 40 M (b) Discharge: - 11.8 Ltrs per second/708 Ltrs per minute (c) Outlet discharge pipe dia: -100mm (Needs to connect with 150mm delivery pipe with suitable reducer will be measured and paid seperately) (d) Voltage range: - 350 to 440V AC, 50 Hz (e) Pump Bowl, suction and delivery:- made with Cast iron, C.I.FG-200 Grade Note-I: - These pumps will be installed at filtered water reservoir as one run/one standby basis and will feed the water to delivery pipe line system, necessary valves/pipe lines needs to be installed which will be measured and paid in the relevant item. If the outlet pipe dia as mentioned not matched with the pump discharge outlet dia the necessary reducer shall also be installed which will be measured and paid separately. Note-II: - The above pump set will be controlled by electronic type controller with stainless steel probe/sensor and float switch for automatic operation and a PLC based control panel for automatic operation with necessary automatic operation time setting, with necessary power cables, control cables, starter and connection all are included in the item rate.
Supplying, laying and fixing along the column pipe or passing through pipes or passing through pipes or laid under floor of through walls etc. jointing and testing of PVC insulated submersible cable 10 sq mm 3 core flat LT 1100 volt graded heavy duty ISI marked with copper conductor and overall served with an outer sheath of PVC complete all as specified and directed.
Supply and lowering MS column pipe (Heavy grade) confirming to IS of size 100 mm dia bore approx 3 m length each duly both ends flanged/ drilled by welding with special provision such as MS clamps and MS flange (size shall be as per IS specifications) and should have two cuts for fixing submersible cable and connecting complete with rubber gasket and nuts bolts etc complete all as specified and directed by Engr-in-Charge
Supply and fixing air release valve PN-1.6 size of 150 mm dia both ends flanged heavy duty including packing materials, nuts bolts washer etc and testing complete all as specified and directed.
M&L for CI reducer 80/100mm with flanged both side complete with fixing with necessary gaskets and nut bolts complete all as specified and directed.
M&L for CI reducer 100/150mm with flanged both side complete with fixing with necessary gaskets and nut bolts complete all as specified and directed.
Supply and lay cable XLPE insulated screened PVC beaded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminum conductor of size 70 Sqmm 3.5 core complete all as specified and directed.
Supply and fixing Pipe DI spigot and socket specials class K 7 supplied and laid in trenches of nominal dia 200 mm bore complete all as specified and directed.
Supply and fixing Pipe DI spigot and socket specials class K 7 supplied and laid in trenches of nominal dia 150 mm bore complete all as specified and directed.
Supply and fixing Pipe DI spigot and socket specials class K 7 supplied and laid in trenches of nominal dia 100 mm bore complete all as specified and directed.
S&F cast iron sluice valve 200 mm dia conforming to IS: 14846, both ends flanged of class PN-1.6 and drilled stainless steel spindle, CI gate with brass ring and iron wheel handle cast iron cap stuffing box etc including joints materials i.e, nuts, bolts , washers, rubber insertion sheet etc complete all as specified and as directed.
S&F cast iron sluice valve 150 mm dia conforming to IS: 14846, both ends flanged of class PN-1.6 and drilled stainless steel spindle, CI gate with brass ring and iron wheel handle cast iron cap stuffing box etc including joints materials i.e, nuts, bolts , washers, rubber insertion sheet etc complete all as specified and as directed.
S&F cast iron sluice valve 100 mm dia conforming to IS: 14846, both ends flanged of class PN-1.6 and drilled stainless steel spindle, CI gate with brass ring and iron wheel handle cast iron cap stuffing box etc including joints materials i.e, nuts, bolts , washers, rubber insertion sheet etc complete all as specified and as directed.
S&F cast iron sluice valve 80 mm dia conforming to IS: 14846, both ends flanged of class PN-1.6 and drilled stainless steel spindle, CI gate with brass ring and iron wheel handle cast iron cap stuffing box etc including joints materials i.e, nuts, bolts , washers, rubber insertion sheet etc complete all as specified and as directed.
Supply and fix cast iron globe stop valve confirming to IS 9338-1984 of 50mm dia by nominal PN-1.6 complete all as specified and directed.
Supplying, fixing and testing of ductile iron pipe fittings (Specials) heavy duty for spigot and socketed / flanged pipes such as, bends (any type radius and angle), tapers, any type straight bend, increasing, decreasing or double socket or socket ad spigot), collars, caps and plugs, adopters etc of any size radius and length confirming to IS specifications up to 200 mm bore complete all as specified.
M & L Construction of brick masonry chamber of 90 cm x 90 cmx 90 cm [internal dimensions] suitable for 80mm/100mm bore sluice valve with PCC 1:4:8 type D2 using 40 mm graded stone aggregate for foundation brick wall with fly ash brick, old size built in CM 1:6 PCC [1:2:4] type B1 [using 20 mm graded stone aggregate for coping rendering in CM [1.4] 15 MM thick including provision of MS sheet cover 3 mm thick with two coats of synthetic enamel paint over a coat of red oxide primer to steel surfaces and locking arrangement including necessary excavation and earth work in any type of soil complete all as specified.
M & L Construction of brick masonry chamber of 60 cm x 60 cmx 60 cm [internal dimensions] suitable for 25mm/50mm bore sluice valve with PCC 1:4:8 type D2 using 40 mm graded stone aggregate for foundation brick wall with fly ash brick, , old size built in CM 1:6 PCC [1:2:4] type B1 [using 20 mm graded stone aggregate for coping rendering in CM [1.4] 15 MM thick including provision of MS sheet cover 3 mm thick with two coats of synthetic enamel paint over a coat of red oxide primer to steel surfaces and locking arrangement including necessary excavation and earth work in any type of soil complete all as specified.
Supply , install, testing and commissioning of cubical housing cabinet type (CPRI approved) LT panel board indoor type, platform mounted factory made, totally enclosed dust and vermin proof openable from both front and rear side made out of 3.15 mm thick CRCA MS Sheet and built upon suitable size angle iron frame work , having front and rear hinged doors, lifting lugs (2 Nos) , earthing strips at rear side , bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts , spring and washers. The cabinet and all members should be chemically treated with MSR solution for anticorrosive treatment and apply spray paint with two coat of synethetic enamel paint over a coat of red oxide primer. The panel should be suitable for 415 volts , 50Hz , 3 phase 4 wire system and internal connection should be provided with aluminium strips of suitable size and necessary foundation work and comprising following:- (a) Bus bar 630 A, 50 KA breaking capacity, IP 54, 04 Nos and accessories@ 1 RM each (b) Incoming MCCB, 4 pole, 250 Amps, 415 Volt AC, 25 KA rupturing capacity -1No (c) Outgoing MCCB, 4 pole, 160 Amps, 415 Volt AC, 25 KA rupturing capacity -1No (d) On load Change over switch front operated panel mounted type 4 pole, 415 Volts AC, 160 Amps.-1No (e) Outgoing MCCB, 3 pole, 63 Amps, 415 Volt AC, 25 KA rupturing capacity -3No (f) Outgoing MCB SPN 32 Amps, 10 kA, 240 volts-2No Metering and accessories Starter-03 Nos
Designing supply, install, testing commissioning Iron removal pressure feed type filtration plant 10000 GPH to with stand pressure 10 Kg/Sq cm with catalytic and filter media (as required size and grade / mesh to obtain potable water recommended parameters as per WHO) including MS frontal pipe (duly welded), Cocks, valves, (inlet outlet, back wash, rinse, bypass complete as per manufacturer's instruction). Provision of main hole Hand hole strainer including air vent system, coagulant feeder with accessories, oxidation chamber with media, (MnO2) with all accessories suitable capacity with all fitting fixture, pressure gauges, RCC/PCC foundation as per OEM recommendation. Drainage system and connected to rising and delivery system including painting and writing complete. The technical details of Oxidation chamber and Multigrade filter are as given below:-
A Oxidation Chamber Feed Flow - 45 M³/Hr Operating pressure - 3.5 kg/cm² Max. allowable pressure drop - 0.5 Kg/cm MOC of vessel - MS Frontal Pipeline Size - 150/100mm Media type - Manganese-di-oxide Thickness in MM (shell and dish-ends) - 6 mm x8mm x8mm MnO2 compound 21 Cft/0.6 Cum Shell dimension 1000 mm dia x 1200 mm SOH Media Quantity - 600 Kg B Multigrade Filter Flow rate - 45 M³/Hr Operating pressure - 3.5-5.5 kg/cm² Max. allowable pressure drop - 0.5 Kg/cm² Continuous duty cycle - 48 Hrs Backwash - 20 Min Rinsing - 10 Min (i) Filtering Media Details (a) Media Type - Mixed sand (b) Depth of sand - 2800 Kg (c) Depth of Gravels support - 2000 Kg (d) Guaranteed life of filtering media - One year
(ii) Vessels Details (a) Type Cylindrical - Vertical (b) Dimension in MM (DIA X HOS) - 2500 mm dia X 1500 mm SOH (c) Free board for back wash - 50% (d) Materials - MS (e) Thickness of body , dish-end & bed plate - 10mm x 12 mm x12 mm (f) Frontal (face) pipeline - 100 mm ERW pipe (medium) (g) Valves in frontal pipe line- Butterfly valves flange less finish-100 mm (h) filter media (sand and gravels) 185 cft/5.285 Cum (i) MnO2 compound -26 Cft/.742 Cum(j) under blade plate system with strainer -Double nut type PVC strainer 450 nosTechnical specification for iron removal filter -45000LPH/10,000 GPH model Ferrotreat VIR 101025FC (k) Air compressor 5 HP 21 CFM- model DH-10 (l) Pressure gauge with fittings -02 set for raw and filter water (m) Chlorine dosing pump with dosing system- Dosing pump :RPQ 40 HD/ dosing system CDS-100 (n) Filtration Rate/ surface velocity -9.80 M3/M2/hr
M&L for GI reducer 150/200 mm with flanged both side complete with fixing with necessary gaskets and but bolts complete all as specified and directed.
HOT WATER SUPPLY Supply, installation, commissioning & testing of storage water heater / geyser 25 Ltrs capacity 5 star rating complete with inlet and outlet pipe with all standard fittings and fixing accessories for fixing to wall including making electrical & water line connections and necessary civil work and complying with the following minimum specifications :- (i) (a) Type : Vertical (b) Capacity of inner tank : 25 Ltrs (c) Colour : White (d) Temperature sensitive LED indicator (e) Feather touch digital temperature control (f) Shock proof 3 pin plug (g) Upto 8 bar pressure resistance inner tank (h) Multi functional safety valve (j) IPX4 technology to protect electrical parts from water splash (k) Earth leakage current breaker to cut off power immediately in case of current leakage and protect user from electric shocks. (l) Tank : made with ultra thick super cold rolled steel paltes dry powder coating finish and energy saving high density PUF installation. (m) Heating element : Glass coated heating element with resistant to oxidation and carbonation at high temperature of capacity 2000 W capacity. (n) Heavy duty magnesium anode rod with steel core to protect enameled tank from rust and corrison 230V, single phase, 50 Hz AC power supply 5 star energy saving rating with BEE level. Make : Havells/Cromption/Bajaj/Recold.
S & F Chromium Geyser connecting pipe complete all as directed.
S & F GI Pipe 15mm bore medium grade fixing on wall with clamp and all accessories complete all as speficed and directed
S&F 15 mm bore fancy type stop valves, cast copper alloy, chromium plated screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified complete all as specified and as directed.
ARBORICULTURE Cleaning of jungle, herbs, debris and dressing the area including cleaning and carting away the de bris out of site.
Making mount as per required size including supplying, dressing, compacting good earth all complete as per instruction of Engineer in Charge.
Land Preparation Trenching in ordinary soil upto a depth of 60cm including removal and stacking of un-serviceable materials and then disposing of by spreading and neatly leveling with in a lead of 50m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or/ and manure before and after flooding trench with water (excluding cost of imported earth , sludge or manure).
Supplying and stacking sludge/ FYM at site in dry caked from approved disposal works including royalty & all lead and lift etc. (sludge measured in stacks will be reduced by 8% for payment)
Rough dressing the trenched ground including breaking clods & Uprooting weeds from the trenched area after 12 to 15 days of its flooding with water including disposal of uprooted vegetation, Fine dressing the ground and Screeding of sludge, dump manure/ farm manure/ animal dung manure and good earth in required thickness (cost of sludge, dump manure / farm manure or/ and good earth to be paid separately)
Grassing Cynoden Dactylan (thine Leaf) : Grassing with Cynodon dactylan carpet , including watering and maintenance the area to free from weeds and maintain the area till end of the maintenance period.
Material and labour for planting and developing Plumeria rubra of 3.0 m height including following :- Digging of pits of sizes as given below in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge/ manure in the ratio 2:1 by volume (2 parts stacked volume of earth after deduction of 20% and one part of manure of stacked volume after deduction of 8%) flooding with water , dressing including removal of rubbish and surplus earth if any with all lead and lift (Note : The earth and mannure will be measured and paid for separately). The size of pits as per girth and height of tree as decided by Engr-in-Charge.
All as per item No (14.76) here in above but for Magnolia grandiflora
All as per item No (14.76) here in above but for Cassia fistula
All as per item No (14.76) here in above but for Azadirachta Indica(Neem)
All as per item No (14.76) here in above but for Alstonia Scholris(Chatim)
All as per item No (14.76) here in above but for Mimusops Elengi( Bakul)
All as per item No (14.76) here in above but for Spathodia Companulata (Flame tree)
All as per item No (14.76) here in above but for Ficus racemosa(goolar)
All as per item No (14.76) here in above but for Nyctanthes arbor tristis(Harshinger)
All as per item No (14.76) here in above but for Psidium Guazava
All as per item No (14.76) here in above but for Syzigium Cumini
All as per item No(14.76) here in above but for Aslbizia Lebbcca
All as per item No (14.76) here in above but for Mangifera Indica
All as per item No (14.76) here in above but for Litchi Chinensis
All as per item No (14.76) here in above Hyophorbe lagenicaulis (over all ht-8')
Supply of plants (shrubs) ht-1 ft including diging of pits as described at item No (14.76) here in above, transportation loading and un-loading & planting for Ficus starlight 2’ height
All as per item No (14.76) here in above but for Crotan (1’ height)
All as per item No (14.76) here in above but for Song of India (1’ height)
Supply of hedge / edge cropton (small/broad leaves) alternanthera, duranta, kamini (murraya exotica) 1 ft height.
Supply, Installation, testing & commissioning of crown type fountain in 3 steps with circular pool of 7 mtr dia. The fountain shall comprise of 24’ dia GI ring with 180 Nos crown nozzles, branches, sockets, stands, supports etc. Make : Glory fountain. Submersible pump at flow of 900 LPM at the head of 16 mtr, 10 HP 2.25 KW, Make : Kirloskar / Cromption / Texmo etc. Under water colour changing LED lights to highlight the Jet suitable for 12 KW 24 Nos supply with LED lights 1 mtr flexible cable all complete 12 Watt each, SMPS and controller for colour changing effect. Make : Glory fountain. 1 No Electrical 10 HP Starter Panel (outdoor type) made up of 16 gauge weather proof powder coated double door body IP-65 protection for recirclulation of pump including incoming MCB, Relay, conductor, Ammeter, Voltmeter single phase, Preventer, Push button, thimbles and wiring of Panel etc with all accessories. Make : L&T and panel make should be CPRI approved. The rate shall be included all necessary civil works i.e. necessary foundation, wall, plastering, glass bead colour tilling complete as decided by EIC.
Complete maintenance of garden features trees, shrubs, hedges/edges, lawn, seasonal flower, fountain etc like hoeing, weeding, punning, watering moving of lawn/plans, rolling of lawn, hedge, elly, upkeepers and maint of potted plants including loading, uploading carriage and displaying removal of garden rubbish spraying insecticides, pesticides, manuring if required and security of all above by employing 01 unskilled Gardener per day all as specified and directed by Engr-in-Charge. Note : The rate shall be deemed to be inclusive of following:- (i) During the period of 11 months any plant, shrubs, grass etc is found dead, not true to name or size as specified or not in satisfactory growth plant of approved size and shape shall be replaced by the contractor without any extra cost to Govt. (ii) If contractor failed to comply above, the work will be carried out through other agency and amount will be recovered from contractor. (iii) Supply and application of manure, sweet earth, sand, pesticides, fertilizers etc are included in the quoted unit rate during maintenance period.
Supply and fixing cast iron metal outdoor bench of size 1.8 m long with arm rest of seating capacity 03 seater with surface finishes as per direction of Engr-in-Charge including fixing with PCC 1:2:4 B1 type complete all as specified and directed.
Note : 1. Tree palantation – (a) Local trees to be planted shall have mix of shady trees, fruit bearing trees and ornamental trees. (b) Tree guard shall be provided for each tree. (c) Trees shall be planted along the approaches (roads) and path ways. (d) Adequate number of shady trees should be planted along the periphery. (e) Vaccant spaces towards the periphery/within te complex shall be planted with fruit bearing trees. (f) Distance between the trees shall be uniform and adequate for the trees to grow. (g) Local trees shall be planted such as Mahogany, Kadam, Shirish, Sonajhuri, Krishnachura, Radhachura, Bakul, Jarul, Gandharaj, Tagar, Palash, Mango, Jamun, Amla, Guava. 2. The plant shall include the open space between the building including park if available. 3. System for watering the plants shall be catered for. 4. In case of open space the slope of the ground shall be such that no accumulation of water takes place. 5. Landscaping and adequate furniture shall be provided for lawns & parks. 6. Hedges shall be included in open space and also around ground floor accommodation.
Internal electrification: M&L for blank plate complete all as specified and directed. Make- C & S(Model-Primo plus)/Crabtree/Legrand/Hager/Anchor
Supply and fixing single phase Air- conditionar starter switch complete all as specified and directed. Make- Havells. SAP Code AHOO002004 or equivalent model of Legrand/Hager/Anchor
Supply and fixing TV socket outlet piano flush type ISI marked with valid CML No. complete all as specified and directed.
Supply and fixing socket outlet RJ 11 for telephone, piano flush type ISI marked with valid CML No. complete all as specified and directed.
Supply and fixing surface & wall mounted LED 4 feet with 1X20 watt LED tube light fittings indoor decorative luminaries with all necessary connection and fixing arrangements with the following specifications: - (i) System Watts/lumens: - Max 20 W/T (ii) Housing: - Extruded polycarbonate (iii) IP rating: - IP 20 (iv) Front cover: - Acrylic/polycarbonate cover (v) Mounting: - Suitable for wall/ceiling mounting (vi) Finish: - Smooth finish (vii) Lamp: - High bright LED (viii) LED Efficacy (lm/Watt): - Not less than 120 lm/watt (ix) Colour temperature: - Not less than 5700 K (x) Colour rendering index (CRI): - Not less than 80 (xi) Life: - Not less than 25000 hrs of operation (xii) Optics: - Designed for optimum light distribution
(xiii) Control gear: - Inbuilt electronic driver with APFC, PF not less than 0.95, and THD not more than 20% of the standard operating voltage 180-270V Ac, 50 Hz (xiv) Surge protection: - Inbuilt surge protection minimum 2 KV (xv) Heat sink: - As per OEM's design (xvi) Bidder has to compulsorily submit the LM-79 and LM-80 NABL acceridite lab test report conforming to technical specifications and consolidate lab test report for the offered LED has to be structured in the sequence (xvii) Make: - As per Appx 'D'
Supply and fixing surface & wall mounted LED 2 feet with 1X10 watt LED tube light fittings indoor decorative luminaries with all necessary connection and fixing arrangements with the following specifications: - (i) System Watts/lumens: - Max 10 W/T (ii) Housing: - Extruded polycarbonate (iii) IP rating: - IP 20 (iv) Front cover: - Acrylic/polycarbonate cover (v) Mounting: - Suitable for wall/ceiling mounting (vi) Finish: - Smooth finish (vii) Lamp: - High bright LED (viii) LED Efficacy (lm/Watt): - Not less than 120 lm/watt (ix) Colour temperature: - Not less than 5700 K (x) Colour rendering index (CRI): - Not less than 80 (xi) Life: - Not less than 25000 hrs of operation (xii) Optics: - Designed for optimum light distribution
(xiii) Control gear: - Inbuilt electronic driver with APFC, PF not less than 0.95, and THD not more than 20% of the standard operating voltage 180-270V Ac, 50 Hz (xiv) Surge protection: - Inbuilt surge protection minimum 2 KV (xv) Heat sink: - As per OEM's design (xvi) Bidder has to compulsorily submit the LM-79 and LM-80 NABL acceridite lab test report conforming to technical specifications and consolidate lab test report for the offered LED has to be structured in the sequence (xvii) Make: - As per Appx 'D'
Supply and fix surface Wall mounting Champagne glod finish fixture with plastic body suitable for 9 Watt LED lamp B22 base including 9 W LED lamp indoor luminaries comlete all as specified and directed. Make:- Havells (Model No:LHFOECE1TZ10014) or eqivalent make as per Appx 'D'.
Supply and fix surface mounted LED mirror light 13 watt Indoor luminaries with and including electronic driver and LED lamp , pre -wired including necessary electric connection from celling rose to light fitting comlete all as specified and directed. Make: Philps (Model: Linea) or eqavalent make as per Appx 'D'.
Supply and fixing LED street light fitting 35/36 Watt 230 V AC outdoor type minium output 105 lumen/watt with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
M&L for Brush Less DC (BLDC) ceiling fan with the following specifications: - (i) Motor: - Brushless DC 26 W, with operating voltage 140V-240V AC, 50 Hz. (ii) Max RPM: - 360 RPM (iii) Sweep: - 1200mm (iv) colour:- white (v) Remote control operated (vi) 5 STAR energy saving rating.
M&L for exhaust fan 250 mm sweep with polycarbonate blades flush mounting, square type body case, operated on 230V, single phase Ac, 50 Hz with connection complete all as specified and dirtected.
M&L for exhaust fan 300 mm sweep with metalic aerodynamically desinged & blanced baldes flush mounting Square type body case blades flush mounting, square type body case, operated on 230V, single phase Ac, 50 Hz with connection complete all as specified and dirtected.
M&L for Wall Mouted fan 400 mm sweep with polycarbonate blades Suitable for wall mounted operated on 230V, single phase Ac, 50 Hz with connection complete all as specified and dirtected.
S & F sheet metal enclosure for vertical Loadline DB's Tripe pole and neutral 6 way double door 415 volts when MCCB 4 pole to be used as incommer complete all as specified and directed.
M&L for MCB SPN 40A, 230V, 50 Hz, computable for DIN rail "C" series , rupturing capacity 10KA with connection complete all as specified and directed.
M&L for MCB SPN 6-32A, 230V, 50 Hz, computable for DIN rail "C" series , rupturing capacity 10KA with connection complete all as specified and directed.
M&L for MCB TPN 40 to 63A, 415V, 50 Hz, computable for DIN rail "C" series,rupturing capacity 10KA with connection complete all as specified and directed.
M&L for MCB TP 40 to 63 A, 415V, 50 Hz, computable for DIN rail "C" series,rupturing capacity 10KA with connection complete all as specified and directed.
M&L for MCB SP 40A, 230V, 50 Hz, computable for DIN rail "C" series rupturing capacity 10KA with connection complete all as specified and directed.
M&L for MCB SP 6 to 32A, 230V, 50 Hz, computable for DIN rail "C" series,rupturing capacity 10KA with connection complete all as specified and directed.
M&L for PVC Concealed conduit only with necessary junctionbox and accessories 20mm for TV and Telephone cable with all cutting and finishing work complete all as specified and directed.
M&L for tamper proof electronic energy meter, single phase, AC 240V, 50 Hz, with accuracy class 1.0, LED indicator , high surge withstand capacity up to 8 KV, polycarbonate enclosure, Anti tamper proof, 15-40A rating with special features like TOD,Tamper logging,optical communication port & display in absence of power with transparent hinge type box ( measure and displays kWH,V,I,kW,PF,last month history of kWH &MD in kW) and necessary sheetmetal meter box complete all as specified and directed.
M&L for tamper proof electronic energy meter, three phase, AC 3X240V, 50 Hz, with accuracy class 1.0, LED indicator , high surge withstand capacity up to 8 KV, polycarbonate enclosure, Anti tamper proof, 10-60A rating with special features like TOD,Tamper logging,optical communication port & display in absence of power with transparent hinge type box ( measure and displays kWH,V,I,kW,PF,last month history of kWH &MD in kW) and necessary sheetmetal meter box complete all as specified and directed.
Ktech Engineer Builders Co. Pvt. Ltd
D R STEEL CONSTRUCTION COMPANY PRIVATE LIMITED
NAND LAL PURI AND SONS PRIVATE LIMITED
NARSINGH DEVELOPERS LLP
LUMOS INFRA PVT LTD
VERMA BROTHERS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid