Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1st₹38.4 LAccepted-AOC | 1st | Accepted-AOC AOC | |
| 2 | 2nd₹38.4 L+₹3,573.34 (0.09%)Rejected-Finance WEST JYOTINAGAR URVASI PATH H NO 16 BAMUNIMAIDAM GUWAHATI 21 | GUWAHATI | ASSAM | 2nd | Rejected-Finance Ref to fin Minutes | |
| 3 | Rejected-Technical | - | Rejected-Technical Technically disqualified |
Tender Value
₹42.7 L
EMD Value
₹85,460
Closing Date
10 Oct 2019, 2:00 pmClosed
MD AIIDC
Bamunimaidam Ghy 21
Construction of R.C.C Post Office building at Industrial Estate Bamunimaidam Guwahati 21
2019_ICD_14240_1
AIIDC/2016/2019/22457 dt 21/9/19
Open Tender
Civil Works - Building
Item Rate
120 days
Bamunimaidam Ghy
Please refer Tender documents.
4 documents required · 4 mandatory
₹1,000
MD AIIDC
₹85,460
Yes
17 Aug 2020
25 Sept 2019
10 Oct 2019
25 Sept 2019
10 Oct 2019
25 Sept 2019
25 Sept 2019 - 10 Oct 2019
Amount
1.1 Earth work in excavation for foundation trenches of walls, retaining walls, footings of columns, steps and septic tanks etc. including refilling (Return filling) the quantity as necessary after completing of work, breaking clods in return filling, dressing, watering and ramming etc and removal of surplus earth with all lead and lifts as directed and specified in following classifications of soils including bailing out water where necessary as directed and specified. (A) Upto a depth of 2 mts. below the existing Ground Level (a) In ordinary Soil
1.3 Earth/ sand filling in plinth in layers not more than 150mm thick including necessary carriage, watering, ramming etc. complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary. (C) With river sand or silt (predominantly non plastic) by truck carriage including loading and unloading.
2.1.1 Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately). (a) In prop. 1:3: 6 (1 cement:3 coarse sand : 6 coarse agg. by volume (using mixture machine) (under footing)
2.1.1 Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately). (b) In prop. 1cement: 4 sand :8 coarse aggregate by volume (under plinth beam etc)
2.1.3 Providing and laying 25mm thick damp proof course with cement concrete in prop 1:1.5:3 with graded stone agg. of 10mm down nominal size including providing approved damp proof admixture in proportion as recommended by the manufacturer including curing etc. complete as directed.
2.2.1 Providing and laying plain/reinforced cement croncrete works cement with coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (I) Using mixture machine (A) In sub - structure up to plinth level Foundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level. (N) Without using admixture, plasticiser (c) M25 grade concrete
2.2.1 Providing and laying plain/reinforced cement croncrete works cement with coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (I) Using mixture machine (B) Super-structure from plinth level upto 1st floor level. Columns, Pillars, Posts, Struts, Suspended Floor, Roof, Landing, Shelf and support, Balcony, Lintel, Sill Band, Beam, Girder, Bressumer, Cantilever, Staircase (Except Spiral Staircase and landing) including preparing the top surface and finishing of nosing. (N) Without using admixture, plasticiser (c) M25 grade concrete
2.2.3 Extra over item Nos. 2.2.1 (I) (B), above for each subsequent floor or part thereof above the 1st floor level.
3.1.1 Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in: 3.1.1.1 Foundation, footings, bases of columns, pile cap, raft and mass concrete works etc. (b) Using 25mm thick plank
3.1.1.2 Sides of tie beams, grade beams etc. at or below ground level. (b) Using 25mm thick plank
3.2.1 Providing form work of 12mm thick Plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in: 3.2.1.1 Columns, Pillars, Posts & Strut of square/ rectangular/ polygonal in plan or any shape like Tee/L etc. having plane vertical face
3.2.1.2 Sides and Soffits of Beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties. (a) For depth not exceeding 1.0M.
3.2.1.3 Flat Surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas, balconies and the like. (a) Floors etc. upto 200mm in thickness.
3.2.1.8 Staircase with sloping or stepped soffits including risers and stringers but excluding Landing.
3.2.2 Extra for each subsequent 1.0M height or part thereof beyound the initial height of 4.0M as mentioned in item no. 3.2.1
4.1.1 Providing soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. (a) Brick on flat soling.
4.1.4 Brick work in cement mortar with 1st class bricks including racking out joints and curing complete. (i) In sub-structure upto plinth level including dewatering. (b) In Prop 1:4
4.1.8 1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth upto 1st floor (Protruding M.S Rod/ Torsteel of column to be embedded in cement mortar and will measured and paid separately) (A) 112 mm thick brick wall (A) In cement mortar in proportion 1:4 ( 1 cement: 4 sand)
9.1.2 Providing wood work in frame (chowkaths) of doors, windows, clerestory windows and other similar works wrought, framed and fixed in position in contact with C.C or brick masonry wall including supplying, fitting and fixing with M.S. hold fast (40mmx3mmx250mm) as per design embeded in cement concrete block in proportion 1:2:4 and with two coats of kiricide oiling to the timber faces in contact with C.C and masonry as directed and specified. (a) With sal wood
9.12.1 Providing and fixing Flush door shutters solid core construction with frame of 1st class hard wood with cross band and face veneered ply wood face panel conforming to relevent to IS Code including oxidised iron butt hinges (100 mm X 75 mm X 3.5 mm) 6 nos. with necessary wood screws. (b) Non Decorative Type and Block Board core (ii) 35 mm thick
18.1.1 Supplying, fitting and fixing in position reinforcement bars conforming to relevent IS code for R.C.C work/ R.B walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports , chairs, spacers etc. complete. (a) From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL (i) TMT Corrosion resistant steel (CRS) reiforcement bar
10.2 Providing, fitting and fixing M.S. grills of required pattern for windows/ clerestory/ openings with M.S. flats at required spacing and frame all round, square or round M.S. bar with round headed bolts and nuts or screws. I. Plain Grill (c) Fixed to Brickwork/P.C.C/R.C.C.
2.1.2 Plain cement concrete floor base in prop1:3:6 laid in alternate bays as specified with coarse agg. of size 13mm to 32mm including dewatering if necessary, and curing etc. complete. (b) 50mm thick
5.7.1.1 Providing Ceramic Tiles of approved quality, size, shape and thickness not less than 8 mm on floors, skirtings, treads and risers of steps over cement mortar bed 15 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with fix-A Tile Choksey/ Sika/ Pedelite/ Rouf/ White cement slurry mixed with approved pigment to match the shade of granite slab, complete at all levels as specified and directed (coloured pigment should be in conformity with colour of slab and as approved and directed by the Department). (a) Normal range Somany/ Orient/Nitco /Asian Make (ii) Of size 400mmx400mm and above
5.7.1.2 Providing polished ceramic wall tiles of approved quality, size, shape and thickness not less than 8mm on walls and skirtings over cement mortar bed 10 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey / Sika / Pedelite / Rouf) /white cement slurry mixed with approved pigment to match shade of tiles complete at all levels as specified and directed. (Cement plastering to be measured and paid separately). (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department). (Walls means both interior and exterior walls). (a) Normal range Somany/ Orient/Nitco /Asian Make (ii) Of size 200mmx300mm and above
5.11.1 Providing Antiskid tiles of approved quality size, shape not less than 8mm on floor, skirtings over a cement mortar bed 15mm thick of 1:3 (1 cement : 3 coarse sand) approved make fix with Fix-A-Tile ( Choksey/Sika/Pedelite/Rouf)/white cement complete at all level as specified and directed. (A) Ceramic tiles (i) Normal range (Sizes 300mmX300mm and above) (a) Orient made: Galaxy Brown, Galaxy creama, Galaxy Pink, Galaxy Green, Pulsar Beige, Pulsar Blue, Pulsar Dove, Pulsar Pink, Burj Brown, Burj Green, Burj Slate
5.9.1 18 mm thick Marble stone slab flooring of sizes 1200x1200 including treads and risers of steps, skirting, laid over 20 mm thick base of cement plaster 1:6 (1 cement : 6 coarse sand) laid and jointed with grey cement slurry including rubbing and polishing complete with marble slab of specified quality and shade at all levels. (i) Marwat Slab
6.2.1 10 mm thick cement plaster in single coat on fair side of brick/ concrete walls for interior platering up to 1st floor level including arises or rounded angles not exceeding 80mm girth and finished even and smooth including curing complete as directed. (a) In cement mortar 1:3
6.2.2 15 mm thick cement plaster in single coat on rough side of single or half brick wall for interior plastering upto 1st floor level including arises, internal rounded angles, chamfers and/ or rounded angles not exceeding 80 mm in girth and finished even and smooth including curing complete as directed. (b) In cement mortar 1:4
6.2.3 15 mm thick cement plaster in single coat on fair side of brick / concrete for interior plastering upto 1st floor level including arises, internal rounded angle chamfers and / or rounded angles not exceeding 80mm in girth and finished even and smooth including curing complete as directed. (b) In cement mortar 1:4
6.2.4 20 mm thick cement plaster in two coat, backing coat 15 mm anf finishing coat 5 mm thick on rough side of single or half brick for interior plastering upto 1st floor level including arises, internal rounded angle chamfers and / or rounded angles not exceeding 80mm in girth and finished even and smooth including curing complete as directed. (A) On rough side (backing coat 15 mm and finishing coat 5 mm thick) (b) In cement mortar 1:4
6.2.5 Extra over item no 6.2.1 to 6.2.3 for plastering on celling and soffits of stairs up to 1st floor level (instead of plastering on walls) including curing complete as directed.
6.2.7 Extra over item no 6.2.1 to 6.2.3 for exterior plastering over wall up to a height of 1st floor level above ground level including curing complete as directed. (b) Two coat plaster
6.2.6 Extra over item no 6.2.1to 6.2.3 for interior plastering above 1st floor level for every addl floor or part thereof including curing complete as directed. (b) On two coat plaster
6.2.8 Extra over item no 6.2.1 to 6.2.3 for exterior plastering over wall for every addl floor or part thereof beyond 1st floor level including curing complete as directed. (b) On two coat plaster
13.3.5 Providing two coats of J.K Wall Putty ( White Cement based putty for concrete/ mortar walls and ceiling both internal and external) after removing all loosely adhering material from the wall surface with the help of emery stone, putty blade or wire brush and moistening the wall with sufficient quantity of clean water as specified and directed by the department. (Total thickness of two coats is maximum 1.5mm)
13.4.7 Wall painting (two coats) with Plastic emulsion paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) on new surface to give an even shade after throughly brushing the surfaces free from mortar droppings and other foreign matter and sand papered smooth. (a) Plastic Emulsion Paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac)
13.9.1 Finishing old / new wall with water proofing weather coat smooth anti-fungal exterior painting of approved make of Berger paint of required shade after cleaning and clearing the surface etc. including scaffolding complete as directed at all levels (two coats).
13.6.3 Applying priming coat over new wood and wood based surfaces over 100mm in girth/width after and including preparing the surface by throughly cleaning oil, grease, dirt snd other foreign matter , sand papering and knotting. (b) With ready mixed paint , wood primer (white).
13.6.5 Painting two coats (excluding priming coat) on new wood and wood based surface with enamel paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surfaces of all dirt, dust and other foreign matter sand papering and stopping. (i) Surfaces over 100mm in width or girth. (a) General purpose (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).
13.7.2 Applying primary coat over new steel and other metal surface over 100m in width or girth after preparing the surface by throughly cleaning oil,grease, dirt and other foreign matter and scoured with wire brushes, fine steels, wood scrapers and sand paper. (a) With ready mixed "Red-Lead"/red oxide primer
13.7.4 Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paint of approved brand and manufacture(Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surface of all dirt, dust and other foreign matter. (i) Surfaces over 100mm in width or girth (a) General purpose (Asian paint/ Berger paint/ ICI paint/ J&N paint/ Nerolac.)
11.1.1 Providing, fitting and fixing anodised aluminium windows and ventilators of standard sections of approved brand without horizontal glazing bars joints mitred and welded (manufactured to relevant IS specifications) fitted with 6mm x 3.15mm lugs 100mm long embedded in CC blocks 150mm x 100mm x 100mm in 1:3:6 mix including providing and fixing handles, frictions stays, joining cleat, bolting device, locking arrangement, spring catch as required complete as specified and directed for all levels. (Cement concrete to be measured and paid separately). (a) Side hung and Top hung windows and ventilators (v) 5 mm coloured glass
11.1.2 Providing, fitting and fixing anodised aluminium sliding windows and ventilators of standard sections of approved brand without horizontal glazing bars, joints mitred and welded (manufactured to relevant IS specifications) and providing and fixing handles, angle cleat, rubber gasket, roller, bolting device, locking arrangements, screws etc as required complete as specified and directed for all levels. (a) 2 Track sliding window (iv) 5 mm clear glass
(b) 3 Track sliding window (iv) 5 mm clear glass
15.2.1 Supplying, fitting, fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete.( anodised to bright natural matt & satin finished ) (a) Sliding door bolts (i) 300 mm x 16 mm
( b ) Tower Bolt ( ii ) 250 mm x 12 mm
( c ) Door Handle ( iii) 150 mm
(t) Door stopper with rubber stopper
SANITARY WORKS 1.2 Providing fitting and fixing vitreous china pedestal type water closet (European type W.C pan 400mm high ) with seat and lead ,CP brass hinges and rubber buffers , CI/MS brackets , 40 mm dia flush band with fittings including painting of fittings and brackets, required. (Flushing Cistern to be paid separately) C) Jaquar make (a) White (i) Size 530 x 370x 360 (Cat No.CNS-WHT-WS01) (inclusive of seat cover)
1.5 Supplying, fiting and fixing PVC flushing cistern with all internal fittings with CI brackets including fitting and fixing standard size CP flush pipe, union clamps etc. compete as directed and specified (pipes will be measured separately) i) Parryware make a) White (i) Economy Single Flush (Cat No.C8090/C8055)
1.13 Providing vitreous China wash basin with CI/MS brackets, C.P brass chain with plug,PVC waste pipe including painting of fittings and brackets, cutting and making good the walls wherever required. (Pillar cock, stop cocks, waste coupling are to be paid separately) Basin (without pedestal) (A) Parryware Make (i) Star Basin 550 x 400 (Cat. No.C0450)
1.18 Providing fitting and fixing Mirror with plastic frame of size 500x400mm complete as directed and specified.
1.20 Providing fitting and fixing Glass Shelf complete as directed and specified. (ii) Sona make (Cat. No.TR-0701) (c) 600mm
1.22 Providing, fitting and fixing CP soap tray / soap dish complete as directed and specified. (a) Continental (Cat.No.ACN-1331N)
1.24 Providing, fitting and fixing CP towel rail complete as directed and specified. (b) Sona make (ii) Towel rail Diplomat 450mm long (Cat.No.TR-0605)
1.31 Providing fitting and fixing Chrome Plated (CP) Toilet paper holder of Jaquar make complete as directed and specified. (d) Sona make (i) Super (Cat. No.AL-1001)
1.37.1 Supplying fiting and fixing PVC pipes of 6Kgf/cm2 (Supreme/Prince) or ISI approved including joining , fitting and fixing with clamps etc. as necessary complete at all levels including below G.L. as directed and specified. (a) In exposed surface or trenches. (ii) 110mm dia.
(iv) 75mm dia.
(b) Concealed by chiselling or breaking brickwall/C.C/R.C.C and making good to the damages. (ii) 110mm dia.
(iv) 75mm dia.
1.37.2 Supplying fiting and fixing 87.5 degree PVC bend of (Supreme/Prince) or ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. (a) In exposed faces or trenches. (ii) 110mm dia.
(iv) 75mm dia.
(b) Concealed by chiselling or breaking brickwall/C.C/R.C.C and making good to the damages. (ii) 110mm dia.
(iv) 75mm dia.
1.37.3 Supplying fitting and fixing 87.5 degree PVC bend with door of (Supreme/Prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L as directed and specified. (a) In exposed faces or trenches. (ii) 110mm dia.
(b) Concealed by chiselling or breaking brickwall/C.C/R.C.C and making good to the damages. (ii) 110mm dia.
1.37.4 Supplying fitting and fixing 45 degree PVC bend of (Supreme/Prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L as directed and specified. (a) In exposed faces or trenches. (ii) 110mm dia.
(iv) 75mm dia.
(b) Concealed by chiselling or breaking brickwall/C.C/R.C.C and making good to the damages. (ii) 110mm dia.
(iv) 75mm dia.
1.37.5 Supplying fiting and fixing PVC Plain single tee of (Supreme/ Prince) or ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. (a) In exposed faces or trenches. (ii) 110mm dia.
(iv) 75mm dia.
(b) Concealed by chiselling or breaking brickwall/C.C/R.C.C and making good to the damages. (ii) 110mm dia.
(iv) 75mm dia.
1.37.7 Supplying fiting and fixing PVC single 'Y' with door of (Supreme/ Prince) or ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. (a) In exposed faces or trenches. (i) 110mm dia.
(ii) 75mm dia.
(b) Concealed by chiselling or breaking brickwall/C.C/R.C.C and making good to the damages. (i) 110mm dia.
(ii) 75mm dia.
1.37.11 Supplying fiting and fixing PVC cross 'T' plain of (Supreme/Prince) or ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. (a) In exposed faces or trenches. (i) 110mmx110mm
(ii) 75mmx75mm
(b) Concealed by chiselling or breaking brickwall/C.C/R.C.C and making good to the damages. (i) 110mmx110mm
(ii) 75mmx75mm
1.37.13 Supplying fiting and fixing PVC coupler of (Supreme/Prince) or ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. (a) In exposed faces or trenches. (ii) 110mm dia.
(iv) 75mm dia.
(b) Concealed by chiselling or breaking brickwall/C.C/R.C.C and making good to the damages. (ii) 110mm dia.
(iv) 75mm dia.
1.37.14 Supplying fiting and fixing PVC reducer of (Supreme/Prince) or ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. (a) In exposed faces or trenches. (iv) 110 mm x 75 mm
(b) Concealed by chiselling or breaking brickwall/C.C/R.C.C and making good to the damages. (iv) 110 mm x 75 mm
1.37.15 Supplying fiting and fixing PVC reducing Tee of (Supreme/Prince) or ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. (a) In exposed faces or trenches. (ii) 110 mm x 75 mm
(b) Concealed by chiselling or breaking brickwall/C.C/R.C.C and making good to the damages. (iv) 110 mm x 75 mm
1.39 Providing fitting and fixing 110mm dia. PVC cowel of ISI make complete as directed and specified.
1.4 Providing fitting and fixing C.I grating to the floors complete as directed and specified. (b) 75mm dia.
1.46 Providing fitting and fixing 450mm dia. 90mm thick C.I. Man hole cover and frame of 25 Kg. Weight complete as directed and specified
1.51 Construction of filter bed in soak pit including earth work in excavation of soil and then filling up of the trench with brick bats/Charcoal covered with earth over a layer of A.C. plain sheet above brick bat filling complete as directed.
1.52 Construction of inspection pit inside measurement 450mm x 450mm x 450mm flush with 100mm diameter HCI/ PVC pipes and cement concrete base in proportion 1:3:6 over flat brick soling, 12cm brick wall in cement mortar in proportion 1:4 finished with 13mm cement plaster in proportion 1:2 in side wall and floor. 450mm x 450mm air tight C.I. inspection pit cover and frame complete including supplying of materials, necessary excavation of pit as directed.
WATER SUPPLY 3.1.1 Supplying fitting and fixing G.I. Pipes of following sizes, with all necessary 'R' brand or similar approved G.I. Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting, H.W. clamps etc.complete at all levels including below G.L. as directed and specified. (I) Exposed or in trenches b) 40 mm dia i) Using Tata (medium)
c) 32 mm dia i) Using Tata (medium)
(II) Concealed by chieselling or breaking brick wall/ C.C. wall/ R.C.C. wall and making good to the damaged structure. d) 25 mm dia i) Using Tata (medium)
e) 20 mm dia i) Using Tata (medium)
f) 15 mm dia i) Using Tata (medium)
3.2.1 Supplying fitting and fixing C.P. bib cock 15mm dia of approved brand directed and specified. (G.I. & C.P pipes will be measured separately) (II) Jaquar make (a) Continental /Clarion (i) Standard
3.3.2 Supplying fitting and fixing chorome plated (C.P) stop-cock of approved brand and size as mentioned below as directed and specified.(G.I. & C.P pipes will be measured and paid separately) (IV) Sona brand (a) 15mm dia Stop cock male-female /Angle stop cock
3.5.1 Supplying and fitting fixing C.P. pillar cock of 15mm dia of approved brand as specified and directed. (IV) Sona make (a) Light type
3.8.2 Supplying fitting and fixing Chrome Plated (C.P.) shower 15mm dia. Of approved brand as directed and specified. (Pipes will be measured and paid separately) (I) Essco make (h) Round shower with revolving joint 100mm dia
3.17.1 Supplying and fitting gun metal country pit valve ( full way valve) I.S.I Make as specified and directed. (b) 40 mm dia
c) 25 mm dia
d) 20 mm dia
3.17.3 Supplying and fitting gun metal check valve I.S.I Make as specified and directed. (b) 40 mm dia (Heavy Type)
WATER TANK 5.4.2 Supplying and placing plastic cylindrical vertical claused top (PCVC) tank of Sintex / Polycon / Patton make over the stagging with manhole cover with locking and cleaning arrangement including providing pads of size as required for inlet and outlet pipes. (iii) 1000 Lt capacity i) Sintex make
5.4.5 Labour for erecting and placing PCVC Tank over the stagging up to a height of 5.00m complete as directed. (c)1000 Lt capacity
Septic Tank 6.2.1 Supplying and placing ferrocement septic tanks of rectangular shape in to pit with manhole cover with cleaning arrangement over single brick flat soling and 75mm 1:3:6 P.C.C. Baffle wall, inlet and outlet etc are provided at suitable points complete as directed. (iv) 25 Users
2.7 Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including earth continuity in surface/ recessed 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit wiring system. 2.7.1 With 2 x 2.5 sq. mm. + earth continuity with 1x1.5 sq. mm. in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
2.7.2 With 2 x 4 sq. mm. + earth continuity with 1x2.5 sq. mm. cable in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
2.7.3 With 2 x 6 sq. mm. + earth continuity with 1x 4 sq. mm. cable in 25 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
2.10 Wiring for 5 pin 6 amp plug with 1.5 sq mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) including 5 pin 6 amp socket outlet (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.)make) and 6 amp flush type switch (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.)make) earthing the 3rd pin of the socket as required on the switch board in surface/ recessed P.V.C. conduit wiring system. When fitted on same board of light and fan.
2.12 Wiring to 5 Aa pin 6 Amps plug point with 1.5 sq. mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed 2 mm thick/ heavy rigid ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system including earth continuity with 1.5 sq. mm. cable to third pin of the plug socket etc. as required complete. 2.12.2 Medium point up to 6.00 metre. Length.
2.12.3 Long point up to 10.00 metre. Length.
2.13 Wiring for 5/6 pin 16 Amps power plug point with 4 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system including earth continuity with 2.5 sq. mm cable to the 3rd pin of the socket as required complete with 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) 2.13.3 Long point up to 10.00 metre. Length.
2.17 Wiring for light/fan/call bell point with 3x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system with 20mm dia 2mm thick / heavy rigid PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) ceiling rose etc. complete. 2.17.1 Short point up to 3.00 metre. length.
2.17.2 Medium point up to 6.00 metre. Length.
2.17.3 Long point up to 10.00 metre. Length.
SB.8.34 Supplying including and fixing of following Metal boxes for MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE in surface/ recessed system complete as per direction of department. SB.8.34.1 1-2 module type Metal
SB.8.34.2 3 module type Metal
SB.8.34.3 4-5 module type Metal
SB.8.34.4 6-8 module type Metal
SB.8.34.5 10 module type Metal
SB.8.34.6 12-16 module type Meta
SB.8.37 Supplying including fitting fixing of following front plate of suitable colour MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE as per direction of department. SB.8.37.1 1 module
SB.8.37.2 2 module
SB.8.37.3 3 module
SB.8.37.4 4 module
SB.8.37.5 5 module
SB.8.37.7 8 module
SB.8.37.8 10 module
SB.8.37. 16 module
SB.8.42 Supplying with fitting fixing of blank plate single in modular switch system MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE complete as per direction of department.
SB.8.63 Supplying with fitting and fixing of RJ-11 Telephone jack MODEL RANGE LEGRAND (MYLINC), ANCHOR (ROMA)A), MK (IVORY), ABB (CLASSIC), KOLORS (KRAZE), SCHNEIDER (OPAL), PHILIPS, Havells including making necessary connection complete as per direction of department.
SB.8.49 Supplying with fitting and fixing of 100 watt electronic modular fan speed controller 4 - Step 2 - module type MODEL RANGE LEGRAND (MYLINC), ANCHOR (ROMA), MK (IVORY), ABB (CLASSIC), KOLORS (KRAZE), SCHNEIDER (OPAL), PHILIPS, Havells including making necessary connection as per direction of department.
SB.8.2 Supplying with fitting fixing of 6 amp one way modular clip in bell push MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department.
SB.8.52 Supplying including installation of socket outlet 6/16 Amps 3/5 pin combine shuttered complete , MODEL RANGE LEGRAND (MYLINC), ANCHOR (ROMA), MK (IVORY), ABB (CLASSIC), KOLORS (KRAZE), SCHNEIDER (OPAL), PHILIPS, Havells including making necessary connection as per direction of department.
SB.8.54 Supplying including installation of socket outlet 6 Amps 3 pin combine shuttered complete , MODEL RANGE LEGRAND (MYLINC), ANCHOR (ROMA), MK (IVORY), ABB (CLASSIC), KOLORS (KRAZE), SCHNEIDER (OPAL), PHILIPS, Havells including making necessary connection as per direction of department.
SB.8.55 Supplying with fitting fixing of 16 amp one way modular clip in switch, MODEL RANGE LEGRAND (MYLINC), ANCHOR (ROMA), MK (IVORY), ABB (CLASSIC), KOLORS (KRAZE), SCHNEIDER (OPAL), PHILIPS, Havells including making necessary connection as per direction of department.
SB.8.57 Supplying with fitting fixing of 6 amp one way modular clip in switch, MODEL RANGE LEGRAND (MYLINC), ANCHOR (ROMA), MK (IVORY), ABB (CLASSIC), KOLORS (KRAZE), SCHNEIDER (OPAL), PHILIPS, Havells including making necessary connection as per direction of department.
SB.10.20 Supplying ,installation, testing & commissioning of 2 pair Unarmoured Telephone Cable through existing conduit in surface/ recess system.
6.1 Supply and fixing of 19 mm dia 1.50mm to 2.00mm average wall thickness heavy rigid PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) on surface system including painting etc as required:
11.37 Supplying and fixing of 40 mm dia hot dip galvanised pipe (AKG or equivalent as approved by the Deptt.) for street light water tight bracket including bending to shape and Wiring with 1.5 sq. mm size aluminium weather proof PVC cable etc.. as required.
11.21 Supplying and fixing of 250/305 mm dia (Nominal size flush type circular ceiling fittings complete with holder, Aluminium anodized back plate and brass holder, 20 Watt CFL lamp including connection as approved by the Deptt.)as required. [CL]
11.26 Supplying and fitting of 18/20 Watt CFL lamp in the existing batten holder/angle holder/decorative bracket/bulk head fitting/ pendent holder etc. as specified and directed by the deptt.
11.31 Supplying and fixing of Call bell ( Buzzer ) including 6 amp capacity flush type bell push switch including connection as approved by the Deptt.)as required.
11.12 Supplying and fixing of polished Brass Bracket of 18 S.W.G, 25 cm long cast back plate and brass lamp holder complete including connection as approved by the Deptt.)as required Without Lamp. [BK]
11.28 Supplying and fixing of Frosted glass shade of 100 mm dia (Nominal Size as required.
11.53 Supplying and fixing of Fan box (AKG or equivalent as approved by the Deptt.)with inbuild rod as required.
15.2 Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 surface mounting SPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. ABB, Schneider MG, legrand, Hager make) 15.2.1.4 12 way SPN Double Door
15.8 Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 double door surface mounting TPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. ABB, Schneider MG, legrand, Hager make) 15.8.1.1 4 way TPN (4+12) double door
16.1 Supplying with fitting and fixing single Pole 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. C Series (Schneider MG, legrand, Hager make) 16.1.2.1 6 to 32A
16.3 Supplying with fitting and fixing DP 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. C Series (Schneider MG, legrand, Hager make) 16.3.1.1 6 to 32A
16.7 Supplying with fitting and fixing 30/100/300mA sensitivity 240/415V 50Hz DP RCCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 100/300mA sensitivity DP RCCB (ABB, Schneider MG, legrand, Hager make) 16.7.2.1 25A
16.6 Supplying with fitting and fixing 4P 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. C Series (ABB, Schneider MG, legrand, Hager make) 16.6.2.3 63A
22.7 Supply, installation & testing of G.I. earth station with perforated 40 mm dia and 4.50 Metre long heady duty G.I. pipe with necessary 40 mm dia. G.I. Fittings such as Socket, Tee, elbow, nipple and 50 mmx40 mm G.I. reducing socket for funnel including locking arrangement 300 mmx300 mmx6 mm hinged cover C.I. earth plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the deptt .
22.12 Extra for using salt (5 K and Charcoal (64 K in pipe Earth Station pit to provide low impedance ground in location of high soil resistivity as and when required and specified by the Deptt.
22.15 Supplying & laying of 6 SWG G.I. earth from Earth Electrode (below G.L.) to electrical switch gears or electrical machineries including making necessary connection as approved, specified and directed by the deptt.
22.20 Supplying & laying of 25X5mm size G.I. strips drawn on surface from earth electrode to Electrical switch gears, machineries etc complete with supply of G.I. nuts & bolts, screws etc including riveting, soldering & making necessary connection as approved, specified and directed by the deptt.
27.1 Supplying including fitting fixing of following A.C. Ceiling fan complete with all accessories like down rod, canopy etc. of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department [Without regulator]. 27.1.2 Premium model 1200 mm Sweep (ORIENT PSPO make) / Premium model 1050 / 1200 mm Sweep SS-390 Deco Havells make) [ F ]
27.2 Supplying including fitting fixing of following A.C. Exhaust fan in the existing hole on the wall of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department. Domestic 27.2.2.12 Ventil Air DB 300 mm sweep (Havells make) [EF]
25.2 Supplying with fitting & fixing of the following integral type street light luminaries complete and consisting of single piece integral epoxy gray powder coated dia cast aluminium housing gasket, pot optic reflector, cast aluminium frame from heat resistance toughened clear glass cover and accessories such as Condenser, lamp Holder, Ballast, lamp etc. in the existing pole including making necessary connection as approved by the Deptt.)with 2× 2.50 sq.mm F.R. multistrand and P.V.C. insulated single core copper cable as specified and directed by the department. Philips make) Cat No.SRX086 1xSON150W For Lamp 1xSON/SONT150W/ HAVELLS make: LHYW00115099 (IP65) For lamp 1x150WSONT. [STL]
32.1 Supply and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV G Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988 armoured U.G. cable U.G. cable laid in ground/partially in air (as required for termination over ground including excavation of cable trench up to depth of 75cm, refilling, protective brick covering, Sand cushioning etc complete handling of surplus spoil, debris et to proper place as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make). 3 & 1/2 Core A2XFY 25.00 Sq.mm 3&1/2 Core U.G. cable in 40mm dia medium duty G.I. pipe
32.5 Supply and laying of following size Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988, LT armoured U.G. cable laid in pucca flooring, road crossing, drain crossing as per site requirement and partially in air to connection as approved by the Depts. the control switch, through medium duty G.I. pipe (Tata/ Nezone make or equivalent as approved by the Deptt) bend and socket including excavation and refilling the trench and making good damage done as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) Core - 3 & 1/2 A2XWY A2XFY 25.00 Sq.mm 3&1/2 Core U.G. cable in 40mm dia medium duty G.I. pipe
32.18 Supplying including installation of cast iron cable marker as specified and directed by the deptt.
NON-SCHEDULED ITEMS Supply, Installation antistatic rubber mat suitable for 1.1 KV Voltage grade
Supply, Fitting Fixing of Shock Treatment Chart
MS UNIQUE CONSTRUCTION AND SUPPLY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .