Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.5 LAccepted-AOC | L1 | Accepted-AOC LOWEST RATE QUOTED | |
| 2 | L2₹21.3 L+₹2.8 L (15.4%)Rejected-AOC | L2 | Rejected-AOC HIGHER RATE QUOTED THA L1 | |
| 3 | L3₹24.0 L+₹5.6 L (30.1%)Rejected-AOC | L3 | Rejected-AOC HIGHER RATE QUOTED THA L1 |
Tender Value
₹22.1 L
EMD Value
₹44,300
Closing Date
30 Aug 2023, 6:00 pmClosed
GE PANAGARH
GARRISON ENGINEER PANAGARH, MILITARY ENGINEER SERVICES, PO-PANAGARH, DIST-BURDWAN, WEST BENGAL, PIN-713420
All as per BOQ
2023_MES_611660_1
8500-009/E8
Open Tender
Civil Works
Works
180 days
PANAGARH
Class E and Category
a(i) (Building)
6 documents required · 6 mandatory
₹500
GE PANAGARH
₹44,300
Yes
21 Sept 2023
2 Aug 2023
31 Aug 2023
2 Aug 2023
30 Aug 2023
16 Aug 2023
Amount
Dismantaling plain or corrugated,semicorugated sheet in roof covering complete all as specified and directed.
Dismantling of Asbestos cement (corrugated, semi corrugated etc) of any thickness incl ridges hips valleys as in roof coverings complete all as specified and directed
Demolition of cement concrete (un-reinforced) not exceeding 15 cm thickness of any description and in any position not otherwise specifically provided for complete all as specified and directed.
Demolition of Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone-work and precast concrete articles complete all as specified and directed.
Taking down cement plaster, any description on brick or stone walls and ceiling ,chajja, landing etc including racking of joints hacking for key scrubbing down with water etc complete all as specified and directed.
M&L for 15mm thick rendering in CM (1:6) on internal surfaces of brick masonry wall finished even and smooth without using extra cement complete all as specified and directed.
M&L for 15mm thick rendering in CM (1:4) mixed with water proofing compound on external surfaces of brick masonry wall finished even and smooth without using extra cement (water proofiing item to be paid separately)
M&L for 10mm thick rendering in CM (1:3) on if air faces of concete surfaces finished even and smooth without using extra cement complete all as specified and directed.
Supply only Liquid water proofing compound complete all as specified and directed. (Makes : Pidilite Industries/ Impermo/Snowcem India Ltd/Sika)
M&L for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed. (Make: M/s Apex Ultima of Asian/ Weather Coat all guard of Berger/Xtra Tough of Shalimar)
M&L for complete removal of existing surface preparation of old plastered surface of wall for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over old surfaces complete all as specified and directed. (Make: M/s Apex Ultima of Asian/ Weather Coat all guard of Berger/Xtra Tough of Shalimar).
S&F for Pre-painted corrugated/semi corrigated galvatume aluminum zinc coating @ 150 GSM GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F Pre-painted galvalume aluminum zinc coating @ 150 GSM GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in Ridges fixed with self tapping screws as specified & directed.
M&L for flat iron fillets (for securing wire mesh, CGI Sheets etc.), Hand rails, half round or other steel section including embeding in concrete and screwing etc, wind ties for roof including securing bolts posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed.
Taking down chowkats or frame not exceeding 1.5 Sqm each with shutter(s) (without taking off shutters from the frame) complete all as specified and directed.
Taking down chowkats or frame exceeding 1.5 Sqm but not exceeding 4 Sqm each with shutter(s) (without taking off shutters from the frame) complete all as specified and directed.
S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge complete shall as specified.
S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, locking arrangement, rollers etc, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-charge etc complete all as specified
S&F stain less steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed.
S&F 4mm thick sheet glass ordinary quality with oil putty in square n.exc. 0.5m in each pane complete all as specified and directed
S&F 4mm thick Figured glass, pin head type and glazing with oil putty in squares n exc 0.5 sq. m in each pane complete all as specified and directed.
S&F 100 mm long Butt hinges, extruded heavy duty stainless steel with galvanised mild steel hinge pin, anodised and fixed, type B-21 complete all as specified.
S&F 125 mm aluminium handles, cast type, anodised complete all as specified and directed.
S&F 150 mm long aluminium, anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed.
S&F 300 mm long aluminium alloy, anodised, sliding door bolt with hasp, staple ( bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and slidibg bolts of extruded section or cast-aluminium alloy complete all as specified and directed
S&F mild steel flat iron as in hold fast clamps small articles conforming to FE 290 GDE-E-165 complete all as specified and directed
M&L for PCC (1:3:6) type C1 (using 20 mm graded stone aggregate) as in bed blocks for hold fast including necessary formwork, kerb stones etc complete all as specified and directed.
S&F floor door stopper of brass body 140 mm long and tongue with rubber shoes complete all as specified and directed..
S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawings
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing.
M&L for Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 50X100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardan and fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made
S&F Factory made single extruded WPC (Wood Polymer Composite) solid decorative panelled decorative flush door shutter one side plain on other side of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge. (Note: stainless steel butt hinges and necessary stainless steel screws shall be paid separately)
M&L for 75mm thick Cement concrete type D-2, :4:8 (using 40mm graded aggregate) as in sub base complete all as specified and directed.
M&L for 25mm thick PCC 1:2:4 type B-1 (using 20mm graded coarse aggregate) in flooring complete all as specified and directed.
M&L for Non-skid joint free coloured ceramic tiles 7 to 8 mm thick (square/rectangular) polished, area exc 0.18 Sqm but not exceeding 0.38 Sqm of each tiles in floors etc set , jointed in cement slurry and pointed in white or coloured cement to match the colour/ shades of tiles complete all specified and directed over screed bed/ bedding layer 15mm thick in CM 1:6 for laying floor finishes etc, complete all as specified and directed. (Note : Design, shade and pattern of fixing of tiles shall be as directed by Engr-in-charge)
All as per item No.35.00 above but as in skirting over rendering 10mm thick in CM (1:3) complete all as specified and directed.
M&L for preparation of new surfaces of roof and applying two coats of Polyurethane (PU) acrylic based water proofing liquid compound over and including one coat of self priming primer @ one litre per 10 Sqm with reinforcing fabric sheet as per manufacturer's instructions to stop leakage/seepage from roof/wall complete all as specified and as directed by the Engr-in-Charge (Notes :- (i). As per description of this item, minimum two coats of Polyurethane (PU) acrylic based water proofing liquid compound over one coat of primer shall be carried out as per manufacturer's instruction. Please note no price adjustment shall be made, if as per manufacturer's instructions more coats of Polyurethane (PU) acrylic based water proofing liquid compound and primer are required for roof treatment. (ii). Quoted Rate shall be deemed to be included for work in building/structure of any height.
M&L for Glazed ceramic coloured tiles in vertical surface 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over 10mm thick CM 1:3 screed bed or bedding layer. (Note : Design, shade and pattern of fixing of tiles shall be as directed by Engr-in-charge)
M&L for 75 mm thick PCC type C-1 1:3:6 (using 20 mm graded stone aggregate) finishing the as in Plinth protection surfaces even and smooth without using extra cement complete all as specified and directed..
M&L for PCC 1:3:6 type C1 (using 20mm graded stone aggregate) as in surface channel complete all as specified and directed.
M&L for broken stone hardcore of guage n.exc 63mm, deposited, spread and levelled in layers n.exc. 15cm thick, watered and rammed to a true surface complete all as specified and directed
S&F in repair Vitreous China urinals,halfl stall type white (back or corner wall type) complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; grating and Union for discharge pipe and Waste coupling 32mm dia minimum weight 45 gms complete all as specified and directed.
S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S.1161- 1979 grade St.-240 complete all as specified and directed.
M&L for 25 mm thick PCC 1:2:4 type B0 (using 12,5mm stone aggregate) as in padding for roof concrete complete all as specified and directed.
M&L for rendering 10mm thick in CM (1:4) finished even and fair using with water proofing compound complete all as specified and directed.
Taking up or down steel tubing 15mm bore and connections, including cleaning for re-fixing or removal to store complete all as specified and directed.
Taking up or down steel tubing 20mm bore and connections, including cleaning for re-fixing or removal to store complete all as specified and directed.
Supply and laying of 15mm outer dia CPVC pipes SDR 11 & CPVC SDR 11 fittings (plain/brass thread as per requirement) in wall as concealed complete all as specified and as directed. (Note: Quoted rate deemed to be included for necessary chasing/cutting and making good the surface)
Supply and laying of 20mm outer dia CPVC pipes SDR 11 & CPVC SDR 11 fittings (plain/brass thread as per requirement) in wall as concealed complete all as specified and as directed. (Note: Quoted rate deemed to be included for necessary chasing/cutting and making good the surface)
Dismantling wrought Iron or mild steel work of any description not otherwise provided for wind tie complete all as specified and directed.
S&F roof trusses (framed), trussed purlins crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle channel or flat sections) including distance pieces, cleats etc. Fe-410-W (Gde-E-250) quality-A complete all as specified and directed.
M&L for applying two coats of synthetic enamel paint over a coat of red oxide primer on newly steel surfaces of any description over 10cm in width or girth not otherwise described incl preparation of surfaces complete all as specified and directed.
S&F 15 dia fancy type chromium plated bib taps cast copper alloy with crutch or butterfly handle, screwed down screwed for iron pipe complete all as specified and directed. Make : Prayag/Cera/Parryware/Hindware
S&F pillar taps, cast copper alloy, fancy type, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts screwed for iron pipe and fixed in repairs complete all as specified and directed. Make : Prayag/Cera/Parryware/Hindware
S&F Vitreous china Squatting pan Orissa pattern of size 580mmx440mm wite with integral foot rests (excluding flushing cistern and flush pipe) complete including concrete bedding in repairs complete all as specified and directed. Make : Cera/Parryware/Hindware
S&F PVC valveless syphonic action type flushing cistern 10 lit capacity low level white with inlet, ball valve, float and handle including brackets and 32mm PVC flush pipe in repairs complete all as specified and directed. Make :Cera/Parryware/Hindware
S&F PVC connection 15mm size with PTMT nuts of length 450mm complete all as specified and directed. Make : Prayag/Polytuf
S&F vitreous china wash basin, white, flat back size 550X400mm, incl cutting for and pinning in ends of brackets or erecting stand but excl taps, pvc connections but incl brackets in repairs complete all as specified and directed. Make : Cera/Parryware/Hindware
S&F tubular towel rail 20mm dia brass chromium plated D type 60cm long between flanges complete all as specified and directed. Make : Cera/Parryware/Hindware
M&L for three coats of white wash on ceiling including preparation of new plastered surfaces complete all as specified and directed.
M&L for preparation of old plaster surface and applying two coats of white wash on old decorated surfaces of ceiling including preparation complete all as specified and directed.
M&L for preparation of old plaster surface and applying two coats of white wash on old decorated surfaces of walls including preparation complete all as specified and directed.
M&L for three coats of white wash on walls including preparation of new plastered surfaces complete all as specified and directed.
S&F 500 Ltr Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top, minimum three layer) hoisted and fixed in position all as specified in SSR Part I complete all as specified and directed. Make : Prayag/Vectus/Sintex
S&F Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed. Make : Prayag/Vectus/Polytuf
Dismantling post (Wood/Steel or RCC) any section including taking out embedded portion and making good disturbed portion complete all as specified and directed
Dismantling fencing wire mesh any type complete all as apecified and directed by Engr-in-Charge
Excavation in trenches in any type of soil n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits,manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out complete all as specified and directed.
Removing surplus excavated spoil/earth to a distance not exc.50M and deposited where directed at a level not exc.1.5 M above the starting point complete all as specified and directed.
Returning filling in soft /loose excavated soil including spreading leveling watering and well ramming in layers not exceeding 25 CM and all as specified and directed.
M&L for Plain Cement Concrete Type D2 1:4:8 (using 40 mm graded stone aggregate) as foundation and mass filling complete all as specified and directed.
M&L for M-25 (Design mix) using 20mm stone aggregate as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concret complete all as specified and directed.
M&L for M-25 (Design mix) using 20mm stone aggregate Columns, pillars, piers, posts and struts complete all as specified and directed.
M&L for M-25 (Design mix) using 20mm stone aggregate Beams, cantilevers, bressummers,lintels over 1.5m span complete all as specified and directed.
M&L for brick work with flyash bricks old size straight or curved on plan to any radius exc 6m mean radius build in CM (1:6) complete all as specified and directed.
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished surface of concrete complete all as specified and directed.
Formwork to sides of pillars, posts, struts, piers, columns and stanchions for fair finished surfaces of concrete complete all as specified and directed.
Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed.
S&F Mild steel bars 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clip complete all as specified and directed.
All as per item No 79.00 above but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and directed.
M&L for 16 to18 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment complete all as specified and directed.
M&L for Plain Cement Concrete Type C2 1:3:6 (using 40 mm graded stone aggregate) as foundation and mass filling complete all as specified and directed.
M&L for brick work with fly ash bricks old size straight or curved on plan to any radius exc 6m mean radius build in CM (1:4) complete all as specified and directed.
M&L for 15mm thick in CM (1:4) rendering on brick or concrete surfaces finished even and smooth with integral water proofing compound (IWPC Measured and paid separately) on wall complete all as specified and directed.
M&L for PCC 1:2:4 type B1 (using 20mm graded stone aggregate) as in coping , benching. Hauncing etc finished even and smooth complete all as specified and directed.
M&L for RCC 1:2:4 type B1 (using 20mm graded stone aggregate) as in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces etc set in CM (1:6) complete all as specified and directed.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using ex- tra cement, including forms, moulds, mi- tred/stopped ends etc. complete all as specified and directed.
M&L for PCC 1:3:6 type C2 Concrete bed to drain pipes of dia 150/160 mm including packing under, and haunching against the sides of pipes after they are laid and tested; in complete all as specified and directed.
S&F UPVC Eco Drain pipe drainage sewaer system pipe bearing 160mm dia minimun 4mm thick including jointing with coupler, bend, tee as per site requirement complete laid in trenches or floors complete all as specified and as directed Note: PCC haunching will be measured and paid seperately
Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar complete all as specified and directed.
M&L for RCC 1:2:4 type B1 (using 20mm graded stone aggregate) as in preacast man hole cover slabs set in CM (1:6) complete all as specified and directed.
E/M PORTION Taking down carefully copper/aluminium conductor point wiring (light,fan,socket or power) complete including fittings such as switches,ceiling roses, pendants, regulators ,sockets etc. and removing (except those to be reused shall be kept in safe custody at the site ) and making good disturbed surfaces of walls, floors etc.to match with the existing complete all as specified.
Taking down carefully by unscrewing from boards/outlet boxes, fittings and fixtures such as switches sockets, ceiling roses, lamp holders, brackets, ceiling fittings, bulk head fittings, tube light fittings and regulators, etc. for reuse at site or carrying to the store (To be measured only when found serviceable in all respects complete for reuse)
M&L for point wiring for light point/ fan point, one light/fan/exhaust fan point controlled by one, one way switch using 1.5 sqmm nominal cross sectional area multistranded copper conductor,PVC insulated unsheathed FRLSH cables in and including 20 mm dia or higher size PVC concealed conduits and fittings of medium grade, including pressed steel terminal switch boxes, 3 mm thick bakelite sheet top cover (ISI Marked) fitted with chromium plated brass screws & washers and 1.5 sqmm nominal cross sectioanl area multistranded copper conductor FRLSH PVC insulated unsheathed earth wire and connecting to earth dolly and brass screws, washers etc. complete all as specified and directed. (Note: Quoted rate deemed to be included for necessary chasing/cutting and making good the surface)
All as per item No.94.00 above but 5 Amp socket on same board with other switches complete all as specified and directed.
M&L for wiring for socket out let on independent Boards controlled by one, one way switch using 2.5 sqmm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed FRLSH cables in and including 20 mm dia or higher size PVC concealed conduits and fittings, including pressed steel terminal switch boxes , 3 mm thick bakelite sheet top cover (ISI Marked) fitted with Chromium plated brass screws & washers and 2.5 sqmm nominal cross sectioanl area multistranded copper conductor , PVC insulated unsheathed FRLSH cable earth wire and connecting to earth dolly and brass screws, washers etc. complete all as specified. (Note: Quoted rate deemed to be included for necessary chasing/cutting and making good the surface)
M&L for wiring for socket outlet 3 pin, 15 amps on independent Boards controlled by one, one way switch using 4.0 sqmm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed FRLSH cables in and including 20 mm dia or higher size PVC concealed conduits and fittings, including pressed steel terminal switch boxes , 3 mm thick bakelite sheet top cover (ISI Marked) fitted with Chromium plated brass screws & washers and 4.0 sqmm nominal cross sectioanl area multistranded copper conductor , PVC insulated unsheathed FRLSH cable earth wire and connecting to earth dolly and brass screws, washers etc. complete all as specified. (Note: Quoted rate deemed to be included for necessary chasing/cutting and making good the surface)
S&F switch piano flush type, single pole, 6 Amps, one way complete all as specified.
S&F switch socket combination 2 in 1 multipurpose 5 pin, (6 Amps) complete all as specified.
S&F Socket outlet 3 pin, 5A, flush type complete all as specified.
S&F switch socket combination 16 Amps, 5 in 1 controlled by one switch complete all as specified.
S&F ceiling rose surface bakelite 65 mm x 50 mm two to three terminal suitable for 230 Volts AC 6 Amps complete all as specified.
S&F in repairs epoxy powder coated sheet metal enclosure for DBs, double door (when MCBs to be used), Single pole and neutral 240 V, 4 ways with mounting fitted with bus bar, DIN channel , neutral link and incoming contact complete all as directed.Note: all wire connection with suitable sizw copper lugs Make :Havells/ABB/legrand.
S&F lamp holder, PVC/polycarbonate type with back plate straight or anfular suitable for batten fittings complete all as specified.
S&F LED light fitting 1x9W/1x10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size Make: Bajaj/Havells/Phillips/CG.
S&F in repair steel body Exhaust ventilation fan of sweep 300mm after taking out the existing burnt out fan complete all as directed by Engr-in-Charge. Make: Bajaj/Havells/Phillips/CG.
S&F GI pipe light grade 40 mm dia of size for road cross of cable,ISI marked all as specified and directed.
S&F LED light fitting 1x 20 W LED light AC decorative box type 4' with driver , holder including LED tube light connedting up with with complete all accessories and connection from ceiling rose with twin core twisted flexible copper conductor cable with suitable size and earthing complete, complete all as directed Make: Bajaj/Havells/Phillips/CG.
S&F wall security light fittings 35 watts 230v, minimumm lumen output 100 lumen/Watt, made up of pressure dia cast housing with prismatic polycarbornate diffuser and individual LED with secondary optic and IP65/66 including necessary connection complete with all accessories including connected with 3 core copper cable of suitable 1.5 sqmm size complete all as directed. Make:Bajaj/Crompton/Phillips/CG
S&F10 W LED light fitting mirror type 2',220volt AC lighting fixture with complete all accessories and connection from ceiling rose with twin core twisted flexible copper conductor cable with suitable size and earthing complete, complete all as directed Make: Bajaj/Havells/Phillips/CG.
S&F epoxy powder coated sheet metal enclosure for DBs, double door (when MCBs to be used), Single pole and neutral 240 V, 8 ways with mounting fitted with bus bar, DIN channel, neutral link and incoming contact complete all as directed. Make :Havells/ABB/Legrand.
S&F 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning complete all as directed. Make :Havells/ABB/Legrand.
S&F in repairs MCB SPN 32 Amps, 'C' series 10kA, 240 Volts and to be housed in DBs complete including necessry connection all as specified and directed. (Note :- Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating) Make :Havells/ABB/Legrand.
M&L XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10sqmmx2core laying properly in treanche all as directed by Engr-in-charge.
M&L for earthing complete with galvanised mild steel earth plate electrode 600x600x6.0mm thick, burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using GI wire 4 mm dia as earth strip electrode bolted or rivetted to earth plate at one end and connected to equipments at another end, GI earth strip encased in and including 15 mm dia GI 'light grade' pipe from upper end of earth plate upto equipments,20 dia bore GI pipe 'light grade' as water pipe from earth chamber to upper edge of earth plate, Test point , GI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS round bars 6mm dia @ 100 c/c both ways with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate of SSR Part I complete all as specified and directed and testing on completion. Note :- If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.
M/S N B SEN CONSTURCTION
M/S JK TRADING
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .