Loading…
Loading…
Tender Value
₹68.9 L
EMD Value
₹1.4 L
Closing Date
9 Jun 2026, 3:30 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
90 days
Expenditure
Capital (Works)
Above/Below/Par
CONS
14 conditions · 2 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or V whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB(GCC) of tender document, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: •Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or •Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or •One similar work each costing not less than the amount equal to 60% of advertised value of the tender.
Defination of Similar Work :- Any electrical installation work involving voltages of 415 volts or greater.
24 conditions · 10 needing a document upload
The tenderer should submit the consent in a mandate form of Enclosure-1 for receipt of payment through NEFT
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Certificates which may be an attested Certificate from the client, Audited Balance Sheet duly certified by the Chartered Accountant etc regarding contractual payments received in the past
Tenderer shall indicate their GSTIN No. & PAN No. with proper document proof.
If the tenderer wish to submit Bank guarantee for bid security (EMD), the Tenderer shall download the Tender Document Annexure -VI A for bid security in the form of bank guarantee and upload the Annexure -VI A duly filling the necessary details. The original Bank Guarantee should be delivered in person to Office of the PCEE, II floor, Shell Administrative building, ICF, Chennai - 600 038 before closing date for submission of bids (i.e. excluding the last date of submission of bids)
Startups are not exempted from satisfying the Eligibility criteria for this tender.
The Tenderer shall have valid required level Electrical License. Attested copy of the Electrical License shall be submitted along with the offer.
The successful tenderer shall prepare and submit the Scheme for wiring along with layout of arrangement of Electrical switchgear drawings according to the site and obtain approval from the competent authority or their authorized representative prior to the commencement of work.
After completion of all wiring and installation, the successful tenderer shall submit 3 sets of General arrangement and Schematic drawings along with the electrical wiring documentation.
The rate quoted shall be net inclusive of all taxes (GST) and duties.
The Contractor has to engage only Police verified Pvt. labour /Pvt. Employee. If any new person (other than already verified) to be engaged by the contractor, he has to submit proof of Police verification application for issuing a "Temporary permission" like present permit system. However, Contractor has to arrange PV report within permissible period of one month.
The tenderer shall download the Tender Document Annexure -I and upload the Annexure -I duly filling the necessary details.
Electrical works for Improvements to Integral Club for officers
2026245212219
2026245212219
Open
Works - General
6 Months
Chennai, Tamil Nadu
₹0
₹1.4 L
9 Jun 2026
16 May 2026
26 May 2026
220 items across 2 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 57,15,477 | ||
| — | 1.00 | — | — | ||
| Supply, installation, testing & commissioning of LT outdoor type double door 12-way panel consisting of Incomer: 630A changeover switch - 1 Nos, 630A 3P MCCB 1 No Outgoing: 400A 4P MCCB-1 No & 100A 3P MCCB - 9 Nos with 50x6mm copper busbar for RYBN, 25x6mm far earth with suitable rotary handle switch, MFM with ON/Off LED indication lamp as per ICF specification. | — | — | — | 5,75,000 | |
| — | 1.00 | — | — | ||
| Supply & erection of 3 phase, LT Modular type, 4-way phase segregation DB with consisting of Incomer: 63A, 4 pole, MCB-1 No. Outgoing: 40A, 2 poles, MCB - 6 Nos as per ICF Specification. | — | — | — | 23,010 | |
| — | 1.00 | — | — | ||
| Supply, installation, testing & commissioning of Modular type 3 phase, 6-way DB with consisting of following items: - 1. 63A 4P MCB-01 No as incomer 2. 63A 4 pole RCCB-01 No 3. 6/10/16A/20A SP MCB - 18 Nos. 4. Connecting cables - 1 set as per ICF Specification. | — | — | — | 38,704 | |
| — | 1.00 | — | — | ||
| Supply and fixing of 4-way SPN DB with 2 no's of 10A SP MCB and 1 no of 25A DP MCB with all accessories as per ICF Specification. | — | — | — | 1,305 | |
| — | 1000.00 | — | — | ||
| Supply of 16 Sq.mm, 4 core, XLPE LT, AL, Armoured, UG Cable as per ICF specification. | — | — | — | 1,49,000 | |
| — | 1000.00 | — | — | ||
| Laying of LT cable up to 300 Sq.mm. Duly Excavating and refilling the trench with excavated earth as per ICF Specification. | — | — | — | 1,41,000 | |
| — | 20.00 | — | — | ||
| Supply & Erection End termination of UG Al cable 3.5 core, up to 50 sq.mm with all required items like proper glands and crimping sockets, hardware, crimping paste etc., as per ICF specification. | — | — | — | 7,400 | |
| — | 5.00 | — | — | ||
| Supply and Execution of LT UG Cable straight through Joint up to 35 Sq mm Aluminum as per ICF Specification. | — | — | — | 7,000 | |
| — | 200.00 | — | — | ||
| Supply & running of 4 core 4 sq.mm copper cable as per ICF Specification. | — | — | — | 50,000 | |
| — | 100.00 | — | — | ||
| Supply & laying of 4 core, 10 sq.mm armored copper cable as per ICF Specification. | — | — | — | 97,100 | |
| — | 300.00 | — | — | ||
| Supply & laying of 5 core 1.5 sq.mm FRLS copper cable as per ICF Specification. | — | — | — | 66,600 | |
| — | 300.00 | — | — | ||
| Supply & laying of 2 core 2.5 sq.mm FRLS copper cable as per ICF Specification. | — | — | — | 39,000 | |
| — | 600.00 | — | — | ||
| Supply of 3 core 1.5 sq.mm FRLS copper cable as per ICF Specification. | — | — | — | 72,000 | |
| — | 6.00 | — | — | ||
| Supply, Installation, Testing &Commissioning of 20W RGB Flood Light as per ICF Specification. | — | — | — | 11,700 | |
| — | 3.00 | — | — | ||
| Supply, Installation, Testing &Commissioning of 30W Down Light outdoor type (IP-54) as per ICF Specification. | — | — | — | 6,300 | |
| — | 6.00 | — | — | ||
| Supply & Fixing of LED Wall decorative light Fitting as per ICF specification. | — | — | — | 5,778 | |
| — | 16.00 | — | — | ||
| Supply, Installation, Testing &Commissioning of single Hanging Pendent type Light as per ICF specification. | — | — | — | 24,000 | |
| — | 20.00 | — | — | ||
| Supply, Installation, Testing & Commissioning of 6 feet bollard lights as per ICF Specification. | — | — | — | 3,44,000 | |
| — | 16.00 | — | — | ||
| Supply, Installation, Testing &Commissioning of outdoor Fancy Bollards 7W with IP 65, 600mm height as per ICF Specification. | — | — | — | 71,760 | |
| — | 20.00 | — | — | ||
| Supply, Installation, Testing & Commissioning of outdoor Fancy Bollards 9W with IP 54, 980mm height as per specification. | — | — | — | 52,000 | |
| — | 10.00 | — | — | ||
| Supply, Installation, Testing &Commissioning of outdoor Fancy Bollards 7W with IP 54, 195mm height as per ICF Specification. | — | — | — | 9,470 | |
| — | 16.00 | — | — | ||
| Supply, Installation, Testing &Commissioning of outdoor Fancy Bollards 12W with IP 54, 600mm height as per ICF Specification. | — | — | — | 66,144 | |
| — | 32.00 | — | — | ||
| Supply, Installation, Testing &Commissioning of outdoor Fancy Bollards 18W with IP 54, 600mm height as per ICF Specification. | — | — | — | 2,07,264 | |
| — | 20.00 | — | — | ||
| Supply, Installation, Testing &Commissioning of outdoor Garden Light warm white/ green 30W with IP 54 as per ICF Specification. | — | — | — | 90,340 | |
| — | 4.00 | — | — | ||
| Supply, Installation, Testing &Commissioning of Dune B7 12W garden lights as per ICF Specification. | — | — | — | 25,200 | |
| — | 11.00 | — | — | ||
| Supply, Installation, Testing & Commissioning of swimming pool lights RGB/DMX 36W:IP68 as per ICF specification. | — | — | — | 3,74,000 | |
| — | 4.00 | — | — | ||
| Supply, Installation, Testing & Commissioning of SMPS drive 350W 24V outdoor type for swimming pool light as per ICF Specification. | — | — | — | 30,000 | |
| — | 30.00 | — | — | ||
| Supply, installation, testing & Commissioning of LED wall washer with RGB W DMX - 512, IP-65 as per ICF Specification. | — | — | — | 4,20,000 | |
| — | 8.00 | — | — | ||
| Supply, installation, testing & Commissioning of power driver for LED wall washer as per ICF specification. | — | — | — | 43,496 | |
| — | 2.00 | — | — | ||
| Supply, installation, testing & Commissioning of DMX 512 controller and decoder for LED wall washer as per ICF Specification. | — | — | — | 1,61,440 | |
| — | 2.00 | — | — | ||
| Wall mount touch panel for DMX 512 controller as per ICF Specification. | — | — | — | 50,000 | |
| — | 9.00 | — | — | ||
| Supply, Installation, Testing & Commissioning of Canopy Light 50W as per ICF Specification. | — | — | — | 34,650 | |
| — | 10.00 | — | — | ||
| Supply, Installation, Testing & Commissioning of wall mount outdoor lens lights 8W for wall elevation as per ICF Specification. | — | — | — | 26,100 | |
| — | 20.00 | — | — | ||
| Supply, Erection, Testing & Commissioning of column lights of 2.6 meters as per ICF Specification (including transportation and civil foundation works). | — | — | — | 4,61,600 | |
| — | 12.00 | — | — | ||
| Supply & erection of 2ft x 2ft 36 watts, 3 in 1, recessed mounting LED fitting as per ICF Specification. | — | — | — | 40,920 | |
| — | 38.00 | — | — | ||
| Supply of 18W (4ft) LED Tube light Luminaire & Batten as per ICF Specification. | — | — | — | 18,544 | |
| — | 38.00 | — | — | ||
| Fixing of 18W LED Tube light Luminaire & Batten as per ICF Specification. | — | — | — | 1,482 | |
| — | 3.00 | — | — | ||
| Supply & fixing of 9/11 LED Mirror light Fitting as per ICF Specification. | — | — | — | 1,323 | |
| — | 8.00 | — | — | ||
| Supply, Fixing Surface Mount 18W LED light as per ICF Specification. | — | — | — | 15,600 | |
| — | 8.00 | — | — | ||
| Supply & fixing of 22W, 3 in 1 Round light as per ICF Specification. | — | — | — | 15,560 | |
| — | 30.00 | — | — | ||
| Supply and fixing of 20W LED Warm white/ white, outdoor type Light as per ICF specification. | — | — | — | 30,990 | |
| — | 20.00 | — | — | ||
| Supply and fixing of outdoor type Down Lights 7W Warm White as per ICF specification. | — | — | — | 38,000 | |
| — | 5.00 | — | — | ||
| Supply, Fixing, connecting, Testing & commissioning of 1200 mm (48") Sweep BLDC DECORATIVE Ceiling Fan with all accessories as per ICF Specification. | — | — | — | 48,970 | |
| — | 16.00 | — | — | ||
| Supply, Fixing, connecting, Testing & commissioning of 1200 mm (48") Sweep BLDC Ceiling Fan with all accessories as per ICF Specification. | — | — | — | 49,776 | |
| — | 10.00 | — | — | ||
| Supply, erection & commissioning of 250 mm (10") Sweep BLDC Exhaust Fan Wall mounted Louver's type as per ICF Specification. | — | — | — | 28,890 | |
| — | 7.00 | — | — | ||
| Supply & erection of 25 Ltrs. Geyser as per ICF Specification. | — | — | — | 94,990 | |
| — | 3.00 | — | — | ||
| Supply, installation, testing & commissioning of 2.0 Ton, inverter type, Split Air- conditioner, 5-star rating as per ICF specification. | — | — | — | 1,62,000 | |
| — | 26.00 | — | — | ||
| Supply of 6 Mtr high octagonal Poles, Pole shall be one section, hot dip galvanized, with suitable base plate and inbuilt terminal box with cover & single arm bracket as per ICF Specification. | — | — | — | 1,87,122 | |
| — | 26.00 | — | — | ||
| Erection of street post including supply of M 20X600 mm foundation bolts for octagonal pole and all masonry materials as per ICF Specification. | — | — | — | 65,494 | |
| — | 30.00 | — | — | ||
| Supply, Installation, Testing & commissioning of 20mm Solid Hot Dip GI earthing spike Rod for streetlight with chamber and earthing compound as per ICF Specification. | — | — | — | 79,860 | |
| — | 26.00 | — | — | ||
| Supply of 45W LED Street light fitting with IP 66 protection along with lens as per ICF Specification. | — | — | — | 79,378 | |
| — | 26.00 | — | — | ||
| Fixing, Testing & commissioning of 45W LED Street light Fitting including supply of necessary fixing brackets and hardware's etc., as per ICF Specification. | — | — | — | 4,940 | |
| — | 600.00 | Each Span | — | ||
| Supply & running of 3 Runs of 1.5 sq.mm PVC FRLS copper cable (Red, Black and Green) in 1" PVC conduit/ Casing capping and accessories as per ICF Specification. (One span Shall consist of one meter length of 3 runs of single core 1.5 Sq.mm FRLS copper cable, PVC pipe., PVC accessories and hardware etc.,)" | — | — | — | 81,600 | |
| — | 500.00 | Each Span | — | ||
| Supply & running of 2 Runs of 2.5 Sq.mm and 1 Run of 1.5 sq.mm PVC FRLS copper cable (Red, Black, Green) in 1" PVC conduit/ Casing capping and accessories as per ICF specification. (One span Shall consist of one meter length of 2 runs of single core 2.5 Sq.mm& 1 run of single core 1.5 Sq.mm FRLS copper cable, PVC pipe., PVC accessories and hardware etc.,) | — | — | — | 91,500 | |
| — | 600.00 | Each Span | — | ||
| Supply & running of 2 Runs of 4 Sq.mm and 1 Run of 1.5 sq.mm PVC FRLS copper cable (Red, Black, Green) in 1" PVC conduit/ Casing capping and accessories as per ICF specification. (One span Shall consist of one meter length of 2 runs of single core 4 Sq.mm& 1 run of single core 1.5 Sq.mm FRLS copper cable, PVC pipe., PVC accessories and hardware etc.,) | — | — | — | 1,34,400 | |
| — | 2.00 | — | — | ||
| Supply & fixing of 16 Module GI Box with front plate for Modular Switch Box and all other required sub-assemblies including fixing of switches/Sockets etc., and internal wiring as per ICF Specification. | — | — | — | 886 | |
| — | 8.00 | — | — | ||
| Supply & fixing of 12 Module GI Box with front plate for Modular Switch Box and all other required sub-assemblies including fixing of switches/ sockets etc. and internal wiring as per ICF Specification. | — | — | — | 2,920 | |
| — | 2.00 | — | — | ||
| Supply & fixing of 8 Module GI Box with front plate for Modular Switch Box and all other required sub-assemblies including fixing of switches/Sockets etc and internal wiring as per ICF Specification. | — | — | — | 650 | |
| — | 14.00 | — | — | ||
| Supply & fixing of 6 Module GI Box with front plate for Modular Switch Box and all other required sub-assemblies including fixing of switches/Sockets etc., and internal wiring as per ICF Specification. | — | — | — | 3,290 | |
| — | 3.00 | — | — | ||
| Supply & Erection of 3 module box with front plate suitable of 20A SP MCB - 1 no, 16A socket-1 no (for AC) as per ICF Specification. | — | — | — | 2,280 | |
| — | 8.00 | — | — | ||
| Supply & fixing of 2 Module GI Box with front plate for Modular Switch Box and all other required sub-assemblies including fixing of switches/Sockets etc and internal wiring as per ICF Specification. | — | — | — | 1,088 | |
| — | 110.00 | — | — | ||
| Supply of 6A Modular switch in the existing modular switch box as per ICF Specification. | — | — | — | 4,400 | |
| — | 30.00 | — | — | ||
| Supply of 6A Modular Socket in the existing modular switch box as per ICF Specification. | — | — | — | 1,650 | |
| — | 20.00 | — | — | ||
| Supply of 16A Modular Switch in the existing modular switch box as per ICF Specification. | — | — | — | 1,440 | |
| — | 20.00 | — | — | ||
| Supply of 16A Modular Socket in the existing modular switch box as per ICF Specification. | — | — | — | 2,000 | |
| — | 1200.00 | — | — | ||
| Supply & laying of 1" dia PVC pipe including laying of PVC cable as per ICF Specification. | — | — | — | 44,400 | |
| — | 100.00 | — | — | ||
| Supply & Erection of Ceiling Rose/ Holder with proper termination as per ICF Specification. | — | — | — | 10,600 | |
| — | 2.00 | — | — | ||
| Supply, Erection, Testing & commissioning of Earthing Electrode to Drg No. ICF/EL/1289 inclusive of supply of all reqd. materials like 50 mm dia pipe, copper strip of size 25X3 mm, all reqd. hardware and all other materials etc., as per ICF Specification. | — | — | — | 17,920 | |
| — | 100.00 | — | — | ||
| — | 25.00 | — | — | ||
| — | 2.00 | — | — | ||
| — | 38.00 | — | — | ||
| — | — | — | 5,282 | ||
| — | 500.00 | — | — | ||
| — | — | — | 31,500 | ||
| — | 10.00 | — | — | ||
| — | — | — | 25,370 | ||
| — | 1.00 | — | — | ||
| — | — | — | 2,47,210 | ||
| — | 6.00 | — | — | ||
| Supply, fixing of 400W LED light for High mast as per ICF Specification. | — | — | — | 1,00,800 | |
| — | — | — | 11,74,827 | ||
| — | 15.00 | — | — | ||
| Supply of 2MP AI WDR Network Bullet Camera - IR 50Mtr, Complaiance RDSO/SPN/TC/65/2021 & Compliance to STQC Certificate as per ICF Specification. | — | — | — | 1,50,030 | |
| — | 5.00 | — | — | ||
| Supply of Full HD Fixed Dome type IP color Camera - IR 40Mtrs, Compliance to clause 6.0 of RDSO/ SPN/TC/65/2021 & Compliance to STQC Certificate as per ICF Specification. | — | — | — | 44,475 | |
| — | 1.00 | — | — | ||
| Supply of 32CH 4K NVR WITHOUT HARD DISK as per ICF Specification. | — | — | — | 19,578 | |
| — | 1.00 | — | — | ||
| Supply and fixing of 55" LED TV as per ICF Specification. | — | — | — | 55,817 | |
| — | 2.00 | — | — | ||
| Supply of 8TB Enterprise HDD for Storage as per ICF Specification. | — | — | — | 67,254 | |
| — | 1.00 | — | — | ||
| Supply of 12 U RACK SERVER RACK-600 MM DEPTH WITH CABLE MANAGER -FAN, TRAY AND 1 PM With Individual Switch control as per ICF Specification. | — | — | — | 11,004 | |
| — | 4.00 | — | — | ||
| Supply of OUTDOOR Termination Box for CCTV as per ICF Specification. | — | — | — | 15,404 | |
| — | 3.00 | — | — | ||
| Supply and Fixing of Galvanized Mounting Bracket Indoor and Outdoor Extendable Tilt up to 12-24 Inch DSLR Camera Projector Ceiling wall as per ICF Specification. | — | — | — | 6,549 | |
| — | 2.00 | — | — | ||
| Supply & fixing of Galvanized - GI Pipe, 8 Feet Height with Mounting Provision from Ceiling as per ICF Specification. | — | — | — | 11,184 | |
| — | 2.00 | — | — | ||
| Supply of 2 Port POE Switch with 1 OFC Uplink as per ICF Specification. | — | — | — | 5,936 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
AnnexureVIABidSecurity.pdf
ATTACHMENT
EL-1289Earthpit.pdf
ATTACHMENT
EL-1451CableTag.pdf
ATTACHMENT
6MOctagonalPolecopy.pdf
ATTACHMENT
927Tenderdocument_2.pdf
ATTACHMENT
IRGCCACSCombined_3.pdf
ATTACHMENT
annex6B.pdf
ATTACHMENT
TenderFormAnnexure-I.pdf
ATTACHMENT
LISTOFPERSONNEL_1.pdf
ATTACHMENT
LISTOFCONTRACT.pdf
ATTACHMENT
LISTOFWORKSONHAND.pdf
ATTACHMENT
LISTOFMachinery.pdf
ATTACHMENT
NEFTForm.pdf
ATTACHMENT
IRGCC_April-2022.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .