Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 CrAdmitted-Finance | ₹1.2 Cr | L1 | Admitted-Finance |
| 2 | L2₹1.4 Cr+₹13.1 L (10.5%)Admitted-Finance 233 PLATINUM PLAZA OPP IOCL PUMP NR JUDGES BUNGLOW CROSS ROAD BODAKDEV AHMEDABAD GUJARAT 380054 | AHMADABAD | GUJARAT | 380054 | ₹1.4 Cr+₹13.1 L (10.5%) | L2 | Admitted-Finance |
| 3 | L3₹1.4 Cr+₹18.0 L (14.4%)Admitted-Finance | ₹1.4 Cr+₹18.0 L (14.4%) | L3 | Admitted-Finance |
| 4 | L4₹1.5 Cr+₹22.0 L (17.6%)Admitted-Finance AP 02 AMRAPALI SAPPHIRE SECTOR 45 GAUTAM BUDDHA NAGAR NOIDA NOIDA GAUTAM BUDDHA NAGAR UTTAR PRADESH 201303 | GAUTAM BUDDHA NAGAR | UTTAR PRADESH | 201303 | ₹1.5 Cr+₹22.0 L (17.6%) | L4 | Admitted-Finance |
| 5 | L5₹1.7 Cr+₹41.8 L (33.4%)Admitted-Finance | ₹1.7 Cr+₹41.8 L (33.4%) | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | EVERCREST PROJECTS PVT LTD. L2 | aselectric corporation L1 | LIVESPACE INTERIORS PVT LTD L4 | Jaydeep Agency Corporation L6 | OM POWER SYSTEMS L7 | Vinay Technical Works L5 | ask enterprises L3 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00MV SWITCHGEAR & POWER PANELS 'Supply, installation, testing and commissioning of cubicle type panels as specified and shown on drawing. i) Main Auminium busbars with bar type feeder connections & all internal wiring and connections. ii) Earthing all components,frame etc. to a common internal earth bar. iii) Painting all sheet metal works. iv) All accessories & supporting structure. v) Brass glands and crimping lugs for sending and receiving ends. vi) All ammeters with C.T's and voltmeter and energy meters with necessary fuses. vii) All Load Managers to have parameters like KW, KVA, A, V, PF,KVAR, Active & Reactive component of power, RS 485 port to have BMS compatibility as required & desired to complete the system. Panel components as specified. viii) MS base frame. ix) All switch gear to have short circuit levels as specified. | ||||||||||
| 2.00 | MAIN LIGHTING & POWER PANEL-2 Schematic as required, specified and shown on drg.No. R-626-E-151 | 1 | Each | 10,73,479 ₹10,73,479 | 12,57,072 ₹12,57,072 | 10,50,000 ₹10,50,000 Lowest | 20,00,000 ₹20,00,000 | 15,00,000 ₹15,00,000 | 12,00,000 ₹12,00,000 | 10,50,000 ₹10,50,000 Lowest |
| 3.00CONDUIT WIRING Conduit wiring for lights fan socket outlets as per the mode of measurements described in the specifications consisting of : d) Wiring in 25/32 mm Dia or conduits getting buried in slab, floor screed,wall chasing with heavy duty PVC conduit.etc. as required for concealed conduiting & HMS FRLS PVC conduit for all conduits exposed above or below false ceiling)/raceway as required. e) 1100V grade PVC insulated Cu multi-stranded FRLS wires. f) Insulated or base protective earth | ||||||||||
| 4.00UTILITY BLOCK | ||||||||||
| 5.00 | Primary Circuit wiring for all Light & Power points Area using 2x2.5 + 1x2.5PE Cu PVC Wires from LPDB | 12 | Each | 1,929 ₹23,148 | 1,145 ₹13,740 Lowest | 2,030 ₹24,360 | 3,280 ₹39,360 | 4,000 ₹48,000 | 3,500 ₹42,000 | 3,625 ₹43,500 |
| 6.00 | Secondary wiring points extending primary circuits to various light & power points | 121 | Each | 482 ₹58,322 Lowest | 732 ₹88,572 | 1,195 ₹1,44,595 | 1,450 ₹1,75,450 | 3,000 ₹3,63,000 | 1,150 ₹1,39,150 | 650 ₹78,650 |
| 7.00 | Primary Circuit wiring for all Light & Power points Area using 2x2.5 + 1x2.5PE Cu PVC Wires from ELDB | 4 | Each | 1,929 ₹7,716 | 1,145 ₹4,580 Lowest | 2,590 ₹10,360 | 5,245 ₹20,980 | 4,000 ₹16,000 | 3,500 ₹14,000 | 3,625 ₹14,500 |
| 8.00 | Secondary wiring points extending primary circuits to various light & power points | 44 | Each | 482 ₹21,208 Lowest | 732 ₹32,208 | 1,195 ₹52,580 | 1,870 ₹82,280 | 3,000 ₹1,32,000 | 1,150 ₹50,600 | 650 ₹28,600 |
| 9.00 | Primary Circuit wiring for all POWER points Area using 2x2.5 + 2x2.5PE Cu PVC Wires from UPSDB | 9 | Each | 2,646 ₹23,814 | 1,341 ₹12,069 Lowest | 2,450 ₹22,050 | 7,275 ₹65,475 | 4,000 ₹36,000 | 3,500 ₹31,500 | 3,625 ₹32,625 |
| 10.00 | Secondary wiring points extending primary circuits to various POWER points | 28 | Each | 661 ₹18,508 | 849 ₹23,772 | 1,615 ₹45,220 | 2,150 ₹60,200 | 3,000 ₹84,000 | 1,500 ₹42,000 | 650 ₹18,200 Lowest |
Tender Value
₹1.6 Cr
EMD Value
₹3.3 L
Closing Date
2 May 2023, 3:00 pmClosed
DIRECTOR TMC
Office of Engineering services, Second Floor,Khanolkar Shodhika , ACTREC Kharghar Node, Navi Mumbai 410210
Supply, Installation, Testing and Commissioning of allied Electrical works for SSPCC Building at ACTREC
2023_TMC_746446_1
ET-143/SITC of allied Electrical works/2023
Open Tender
Electrical Works
Item Rate
330 days
ACTREC-Kharghar
As per Tender Document
2 documents required · 2 mandatory
₹0
₹3.3 L
Yes
ACTREC, KHARGHAR
20 Dec 2023
23 Mar 2023
3 May 2023
23 Mar 2023
2 May 2023
23 Mar 2023
23 Mar 2023 - 30 Mar 2023
31 Mar 2023
Amount
MV SWITCHGEAR & POWER PANELS 'Supply, installation, testing and commissioning of cubicle type panels as specified and shown on drawing. i) Main Auminium busbars with bar type feeder connections & all internal wiring and connections. ii) Earthing all components,frame etc. to a common internal earth bar. iii) Painting all sheet metal works. iv) All accessories & supporting structure. v) Brass glands and crimping lugs for sending and receiving ends. vi) All ammeters with C.T's and voltmeter and energy meters with necessary fuses. vii) All Load Managers to have parameters like KW, KVA, A, V, PF,KVAR, Active & Reactive component of power, RS 485 port to have BMS compatibility as required & desired to complete the system. Panel components as specified. viii) MS base frame. ix) All switch gear to have short circuit levels as specified.
MAIN LIGHTING & POWER PANEL-2 Schematic as required, specified and shown on drg.No. R-626-E-151
CONDUIT WIRING Conduit wiring for lights fan socket outlets as per the mode of measurements described in the specifications consisting of : d) Wiring in 25/32 mm Dia or conduits getting buried in slab, floor screed,wall chasing with heavy duty PVC conduit.etc. as required for concealed conduiting & HMS FRLS PVC conduit for all conduits exposed above or below false ceiling)/raceway as required. e) 1100V grade PVC insulated Cu multi-stranded FRLS wires. f) Insulated or base protective earth
UTILITY BLOCK
Primary Circuit wiring for all Light & Power points Area using 2x2.5 + 1x2.5PE Cu PVC Wires from LPDB
Secondary wiring points extending primary circuits to various light & power points
Primary Circuit wiring for all Light & Power points Area using 2x2.5 + 1x2.5PE Cu PVC Wires from ELDB
Secondary wiring points extending primary circuits to various light & power points
Primary Circuit wiring for all POWER points Area using 2x2.5 + 2x2.5PE Cu PVC Wires from UPSDB
Secondary wiring points extending primary circuits to various POWER points
GROUND FLOOR
Primary Circuit wiring for all Light points Area using 2x2.5 + 1x2.5PE Cu PVC Wires from ELDB
Secondary wiring points extending primary circuits to various light points
THIRD FLOOR
Primary Circuit wiring for all Light points Area using 2x2.5 + 1x2.5PE Cu PVC Wires from LDB
Secondary wiring points extending primary circuits to various light points
Primary Circuit wiring for all Light points Area using 2x2.5 + 1x2.5PE Cu PVC Wires from ELDB
Secondary wiring points extending primary circuits to various light points
Primary Circuit wiring for all Power points Area using 2x2.5 + 1x2.5PE Cu PVC Wires from NPDB-1
Secondary wiring points extending primary circuits to various power points
Primary Circuit wiring for all POWER points Area using 2x2.5 + 1x2.5PE Cu PVC Wires from UPSDB
Secondary wiring points extending primary circuits to various POWER points
Supply & Installation switch, socket incuding & complete accessiors to finish the job
1# - 5A Plate type switch
2# - 5A Plate type switch
3# - 5A Plate type switch
4# 5A Plate type switch
15A plate type switch + 5/15A plate type socket.
2#15A plate type switch + 2#5/15A plate type socket.
Supply & Installation GI back box & Face Plate with earthing. etc. incuding complete accessiors to finish the job.
1# Module GI Flush Mounting Back Box with Face plates with Frame
2# Module GI Flush Mounting Back Box with Face plates with Frame
3# Module GI Flush Mounting Back Box with Face plates with Frame
4# Module GI Flush Mounting Back Box with Face plates with Frame
6# Module GI Flush Mounting Back Box with Face plates with Frame
ELEVATOR
Hoist way maintenance Lighting and Power for stretcher LIFT including supply & intallation of I) 1# 5/15A Switch Socket per Floor ii)1# 9w Led Bulkhead Light Fixture iii)1# 5A switch to control Bulkhead Light Fixture iv) Conduit Wiring for above using 3# 2.5 Sq.mm Cu wires in GI Conduit
Hoist way maintenance Lighting and Power for SERVICE/FREIGHT LIFT including supply & intallation of I) 1# 5/15A Switch Socket per Floor ii)1# 9W LED Bulkhead Light Fixture iii)1# 5A switch to control Bulkhead Light Fixture iv) Conduit Wiring for above using 3# 2.5 Sq.mm Cu wires in GI Conduit
Hoist way maintenance Lighting and Power for STAFF LIFT- including supply & intallation of I) 1# 5/15A Switch Socket per Floor ii)1# 60w Bulkhead Light Fixture iii)1# 5A switch to control Bulkhead Light Fixture iv) Conduit Wiring for above using 3# 2.5 Sq.mm Cu wires in GI Conduit
Supply and installation of 3Cx2.5Sq.mm YRY Cable from 'all Lift Lighting DB's to the junction box in hoist way 'for Car Lighting including 8way Elemech connector
Supply and installation of 3Cx 2.5Sq.mm Cable terminations on both sides & 1# Junction box to terminate 3c x 2.5 Sq.mm cu cables
ASHLOK Earthing Stations
Providing Plate earthing stations for for equipment earthing with 600x600x3mm CU plate as specified and shown on drawings and in IS 3043 -1987 complete with: FOR UPS System, DG NEUTRAL, TRANSFORMER NEUTRAL, LV SYSTEM. a) Excavation in hard murram b) Electrode with disconnecting link arrangement. c) Watering pipe. d) Brick masonary chamber with C.I frame and hinged covers. e) Charcoal & salt fill. f) VX EHT red compound minimum 50 Kgs as specified
Providing Plate earthing stations for for equipment earthing with 600x600x3mm CU plate as specified and shown on drawings and in IS 3043 -1987 complete with: FOR UPS System, DG NEUTRAL, TRANSFORMER NEUTRAL, LV SYSTEM. a) Excavation in hard murram b) Electrode with disconnecting link arrangement. c) Watering pipe. d) Brick masonary chamber with C.I frame and hinged covers. e) Charcoal & salt fill. f) VX EHT red compound minimum 50 Kgs as specified
Earth wire/strips Supply & laying CU/GI earthing strips for interconnecting the earthing stations, panels, DB's etc. in built-up trenches, on walls/ceiling, buried in ground, generally as specified & shown on drawings complete with; c) Fixing accessories. d) Corrosion protection of buried conductors with bituminous coating and covered with PVC tapes.
50 x 6 mm C U
50 x 12 mm G I
50 x 10 mm G I
40 x 12 mm G I
40 x 10 mm G I
50 x 6 mm G I
40 x 5 mm G I
25 x 5 mm G I
25 x 3 mm CU
8 SWG CU WIRE
LIGHT FIXTURES & Fans Supply & Installation, testing & commissioning of light Fixtures complete with: e) All fixing accessories & mounting bracket. f) Earthing of fittings. g) Connections from the ceiling rose or junction box of the fitting h) All light fixture to be consider with lamps.
1x28W FTL type Fluorescent Fitting wall/ceiling mounted PHILIPS MAKE PENTURA-TMS 122 / 1228 (HF)equivalent fixture subject to architects\clients approval.
1x36W LED Recessed Grid -Ceiling Luminaire, Suitable for 600 X 600 module and is enclosed with high efficient flat PMMA low glare diffuser.LEGERO MAKE LRS 3036 equivalent fixture subject to architects\clients approval.
Exit light similar to PROLITE make PEL LED E/M (s) Slim Led Exist Light.
Recessed down lighter with 2 x 18W Fugato Performance FBH 261 fixed Downlight with Compact PHILIPS MAKE FBS261 2xPL-C/2P28W/840 IC M PL GR (HF)equivalent fixture subject to architects\clients approval.
1x26w FANTASY Surface mounted light fixture FWP 47126 WIPRO MAKE fixture subject to architects\clients approval.
1X12W wall mounted light fixture PHILIPS Light Make Mod No. 12W LSO3412 OREON WALL MOUNTED IP65 Or equivalent subject to architects\clients approval.
Supplying and erecting five star rated energy saving Ceiling fan 230 V A.C. 50 cycles 1200 mm complete erected in position as per specification no. FG-FN/CF
Supplying and erecting exhaust fan heavy duty 230 V A.C. 50 cycles 375/380 mm. 1400 RPM complete erected in position as per specification no. FG-FN/EXF
Supplying & fixing anchor type fastener fan hook, with 2 nos. of 10 mm dia x 75 mm long with necessary materials for ceiling fan.
Supplying and erecting fan hook of 10 mm. M.S. round bar grouted in RCC slab with making the site as original.
Supplying and erecting ‘B’ grade G.I. pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire.
Supplying and erecting electronic type step regulator for ceiling fan 600/ 900/ 1200/ 1400 mm. sweep, complete erected on provided switch board.
Lightning Protection AIR TERMINATION SYSTEM
Supply & laying of 8mm Aluminum Solid Round Conductor for building terrace as a horizontal air terminal as per required LPL and should be tested for electrical resistivity, Tensile strength, Yield strength, % elongation, salt spray & humidity test to meet the requirements of IS/IEC 62305 and IEC 62561-1&2. CAPE Type: SRC 8 – AL (Article No. 400 008)
SITC of Stainless steel Parapet Conductor Holder suitable for 8mm dia to be fixed above concrete Parapet with fixing Screws to meet the requirements for IS/IEC 62305. CAPE Type: PCH 8 (Article No. 400 202)
SITC of Flat roof Conductor Holder suitable for 8mm dia to be fixed above flat roof without puncturing RCC/Surface at every 1 Mtr to meet the requirements for IS/IEC 62305. CAPE Type: CFRCH 8 (Article No: 401 201)
SITC of Stainless Steel cross connector suitable for 8mm dia and should be tested for electrical resistivity, Mechanical strength, salt spray & humidity test to meet the requirement of IS/IEC - 62305 and IEC 62561-1&2. CAPE Type: CCSS 8- 10 (Article No. 400 206)
SITC of Expansion Piece with connector to compensate the expansion and contraction of Solid Round Al. Conductor during temperature variations to be provided on conductors length over 20 meters with Expansion Piece Connector for to connect Solid Roung Al. Conductor at both ends to meet the requirements for IS/IEC 62305 CAPE Type: EPC 8 ( Article No. 401 209)
SITC of Aluminium Straight connector for connecting 8mm Aluminium conductor and should be tested for electrical resistivity & Mechanical strength to meet the requirements for IS/IEC 62305 and IEC 62561-1&2. CAPE Type: CJ 8 (Article No. 401 211)
SITC of stainless steel Earth stud of dimension 70 x 70 mm integrated inside concrete and should be tested for electrical resistivity, salt spray and huminity test & short circuit to meet the requirements of IS/IEC 62305 and IEC 62561-1&2.5. (for interconnecting ELPS and structral down conductors) Cape Type No. ES 1 ( Article No. 401 510 )
SITC of stainless steel Folding clamp for connecting air terminal on the metal roof .Clamping range 5-20 mm thick sheet to meet the requirements of IS/IEC 62305. Tested for Electrical ,Mechanical and Chemical as per IEC 62561. Cape Type FC 20 ( Article No. 400 409)
STRUCTURAL VERTICAL RISER
Supply & laying of 10 mm copper bonded Solid Steel Round Conductor with average coating thickness 120μm as integrated down conductor. Material should be tested Tensile strength, Electrical Resistance, salt mist, Bend & Adhesion to meet the requirements of IS/ IEC 62305 and IEC 62561-1&2. CAPE Type: SRC 10 – CU (Article No. 400 010)
SITC of MS Bonding clamp for interconnecting 10 mm Round Conductor with reinforcement rebar at every 3Mtr inside the concrete to meet the requirements of IS/IEC 62305. CAPE Type: MS MPBC 1632 (Article No. 408 506)
SITC of stainless steel Straight Connector at every 3 Mtr of integrated down conductor and should be tested for electrical resistivity, mechanical load to meet the requirement for IS/IEC - 62305 and IEC 62561-1&2. CAPE Type: SC 8-10 (Article No. 400 210)
SITC of stainless steel Earth stud of dimension 70 x 70 mm integrated inside concrete and should be tested for electrical resistivity, salt spray and huminity test & short circuit to meet the requirements of IS/IEC 62305 and IEC 62561-1&2.5. Cape Type No. ES 1 ( Article No. 401 510 )
STRUCTURAL FOUNDATION EARTHING
Supply & laying 10 mm copper bonded Solid Steel Round Conductor with average coating thickness 120μm for Type-B Earthing and should be tested for Tensile strength, Electrical Resistance, salt mist, Bend & Adhesion to meet the requirements of IS/ IEC 62305 and IEC 62561-1&2. CAPE Type: SRC 10 – CU (Article No. 400 010)
SITC Installation of Exothermic Welding - Including welding mould and other accessories for welding confirms the requirements of IEEE 837:2014 : T-Joint, X-Joint, L-Joint , Straight joint CAPE Article: 400 880
AVIATION LIGHTING SYSTEM
Supply, installation, testing & commissioning (with necessary internal wiring) of the system which shall comprise dual Medium intensity Obstacle / Aviation light @ Terrace Level as specifed below – Lights to operates on 240V, single phase A.C (50Hz).Dual lights shall be supplied with intensity step changer including all accessories, lighting to be at 40,000cd during daylight hours automatically step changed down (by the control panel to 2,000cd) during dusk till dawn.Louvers to be provided to all lights to avoid dazzle to aircraft and local residents. Fittings to be compliant to: Unit shall comprise: •Stainless steel sun shield •Anodized aluminium cap holder •Polycarbonate cap •Internal reflector •IP66 glad plates on lights •Flash Head Assembly (25 flashes per minute) : Contractor to agree with Mumbai Civil Aviation Authority •Flash head control unit. •Unit-directional white flashing light designed to provide 120º horizontal with narrow vertical beam pattern. •Beam angle adjustment in vertical plane available. •Remote fault monitoring of individual light required. •All enclosures made in stainless steel grade 304.
•Draw out type panels for ease of maintenance. •Built in Surge Protection Operating Conditions •Suitable for temperatures ranging from -30°C to +55°C. •Will withstand wind in excess of 150 mph (221 kph), (150 knots) •Fog, Rain •Humidity : up to 100% •Does not create Electromagnetic Interference •Does not create Radio Frequency Interference.
•Dual Medium Intensity Light (40,000 cd /2,000 cd) - Medium intensity (Type A 2,000cd) flashing white lights for night-time & Medium intensity (Type A 40,000cd) flashing white lights for daytime. •Low Intensity Light (2,000 cd )
13) Active Warning and Shut-Off Circuitry, with audio indicator and automatic shut-off of power feed to AOL units in case of Flasher failure. 14) Flasher Diagnostic Bypass Switch 15) Photoelectric switch unit, with amplifier activating a solid state relay. 16) Mimic on front fascia for convenience in control and troubleshooting diagnostics 17) Input and output cable glands.
•Wiring from Control Panel to Aviation Light with 2 x 4 Sq.mm FR PVC + 1 no 2.5 sq mm FR, PVC ( Green for earth) insulated multi-stranded copper conductor cables in recessed heavy duty 32mm PVC (HMS) conduit including ITC of modular back box consisting of concealed M.S. box/Junction Box of 18 SWG, etc. as required. Contractor shall provide a secure screwed gladed connection between the back box and conduit.
EVERCREST PROJECTS PVT LTD.
ask enterprises
LIVESPACE INTERIORS PVT LTD
Vinay Technical Works
Jaydeep Agency Corporation
OM POWER SYSTEMS
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.76 MB
SLD.pdf
Additional Documents • 6.96 MB
BOQ_784824.xls
BOQ • 0.29 MB
tenderdocument.pdf
Tender Documents • 2.29 MB
AnnexureForm.xls
Additional Documents • 0.11 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .