Commander Works Engineer NW Dr Homi Bhabha Road Navy Nagar Colaba Mumbai 05
REPAIR TO WATER COOLERS WINDOW SPLIT TYPE ACs REFRIGERATORS DUCTABLE ACs COLD STORAGE AT PATIENT GALLIES AND MORTURY REPAIR REPLACEMENT OF AHUs FCUs RUs INCL PUMPS BLOWERS AHU PIPE LINES AND MISC CONNECTED VALVES AT INHS ASVINI UNDER AGE I ASVINI COL
2023_MES_576640_1
8017/CWE (NW) Mumbai/ E8
Open Tender
Civil Works
Item Rate
330 days
AGE (I) Asvini
Class C
7 documents required · 7 mandatory
₹1,000
Yes
AGE (I) Asvini
₹1.4 L
Yes
27 Apr 2023
23 Jan 2023
3 Mar 2023
23 Jan 2023
1 Mar 2023
15 Feb 2023
23 Jan 2023 - 11 Feb 2023
Amount
Taking down old rectangular square duct and supply & erect factory fabricated rectangular/square duct made out of 24 gauge sheet in L shaped hollow profile incl all accessories such as corner, carraige bolt hangers, gasket and seal the longitudinal joints with and incl approved sealant complete all as specified and directed by Engineer-in-Charge
Taking out old unserviceable AHU body & supply and fixing of factory fabricated double skinned powder coated GI frame of 21 gauge, 25 mm thick CFC puf insulated for AHU body including proper door handles, corner supports cutting, bending, welding/ brazing/ wooden work/ structural support complete all as specified and directed by Engineer-in-Charge
Material & labour for anodised aluminium frames for AHU Panel with one or more rebates, welding, jointing cleats for fixing etc, including dismantling of old anodised aluminium frames,complete all as specified and directed by Engineer-in-Charge
Supply and fix in repairs AHU cooling coil of any size and any rows as per existing at site complete all as specified and directed by Engineer-in-Charge
Taking down old unserviable Fire damper and supply and fix new Fire damper made out of GI sheet 16 G with fusible plug as per existing size complete all as specified and directed by Engineer-in-Charge
Material and labour for rewinding of electric motor of the following capacity, 3phase 50hz, 415V with super enamelled copper winding wire of suitable guage including dismantling, assembling after rewinding to its original location of capacity 5 HP complete all as specified and directed by Engineer-in-Charge
All as per Srl Item No. 6.00 here in before but 7.5 HP complete all as specified and directed by Engineer-in-Charge
All as per Srl Item No. 6.00 here in before but 10 HP complete all as specified and directed by Engineer-in-Charge
All as per Srl Item No. 6.00 here in before but 15 HP complete all as specified and directed by Engineer-in-Charge
Taking down old unsv GM gate/globe/Air relief valve,Supply and fixing of new GM Gate/Globe valve with of 25 mm dia complete all as specified and directed by Engineer-in-Charge
Taking down old unsv CI butter fly valve of any make and size and supply and fixing of new CI Butter fly valve slim seal design with nitrile rubber lined seat with clutch lever (p10) as per IS 13095 of size 100mm complete all as specified and directed by Engineer-in-Charge
All as per Srl Item No. 8.00 here in before but but 80mm
All as per Srl Item No. 8.00 here in before but but 65mm.
All as per Srl Item No. 8.00 here in before but but 50mm.
Material & labour for perforated GI cladding with 26 gauge GI sheet suitable for covering the surface of AHU pipe line insulation for protection against the damage of PUF insulation slab complete for 100 mm pipe complete all as specified and directed by Engineer-in-Charge
All as per Srl Item No. 09.00 here in before but but 80mm dia.
All as per Srl Item No. 09.00 here in before but but 65 mm dia.
All as per Srl Item No. 09.00 here in before but but 32 mm dia.
All as per Srl Item No. 09.00 here in before but but 25 mm dia.
Taking down old unsrv MS pipes, supply, lay & welding of MS pipes of heavy grade with all fittings laid in floors or fixed to wall & ceillings etc of size 100 mm complete all as specified and directed by Engineer-in-Charge. Make: Jindal or equivalent.
All as per Srl Item No. 10.00 here in before but but 80 mm dia.
All as per Srl Item No. 10.00 here in before but but 65 mm dia.
All as per Srl Item No. 10.00 here in before but but 32 mm dia.
All as per Srl Item No. 10.00 here in before but but 25 mm dia.
Taking down old unserviceable/deteriorated insulation from any surface & fix Nitrille rubber insulation of one layer of 19mm thickness sticking on surface by using approved adhesive and sealing the joints by weather proof tape complete all as directed by Engineer-in-Charge.
Taking down old unservicieable Aluminium rectangular grill of any type & make and supply & fix new air/return air of aluminium rectangular grills complete with wooden frame work made out of II nd class hard wood, volume control damper incl gasket and connected accessories complete all as specified and directed by Engineer-in-Charge
Material & labour for cleaning of coil section of any size AHU/FCU for descaling & providing 2 Nos 15mm Tee outlet for local circulation of mild acid solution in the coil (separate container & small pump set to be used for circulation) PH value Zem solution to be kept at 4 & checked at an interval of 1 hour duration process the scalgum/WS/Cleansol or equivalent solution to be used for descalling if PH value remains less than 7 flush with fresh water added to sodium carbonet till PH value become 7, relax the coil section in position incl minor repairs to be carried out in AHU coil bins to be cleared by scalgum solution by spraying the solution with washing pump up to required level and repalcement of canvas connection between AHU complete all as specified and directed by Engineer-in-Charge
Material and labour Steel structural fabrication works fabricated from structural steel sections including nuts, bolts,washers, welding ,bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primary coat, one under coat and one finishing coat of paint complete all as specified and directed by Engineer-in-Charge
Supply and fix in repairs blower set including drum and shaft along with anti-vibration spring isolators for minimizing vibrations(Blow/draw through type) as per the existing size and suitable for size RDH 350- 450 CFM of the AHU/FCU/RU unit complete all as specified and directed by Engineer-in-Charge
Supply and fix in repairs blower set including drum and shaft along with anti-vibration spring isolators for minimizing vibrations (Blow/draw through type) as per the existing size and suitable for size RDH 450-500 CFM of the AHU/FCU/RU unit complete all as specified and directed by Engineer-in-Charge
Supply and fix in repairs double groove V - belt pulley of various sizes including boring and making key slots as per site requirement and directed by Engineer-in-Charge.
Taking down old unserviceble drain pan of cooling coil from AHU box and supply and fix new condensate drain pan fabricated from 1 mm thick SS304 wider drain pan with differential slope assures quick and complete water drainage, thus avoiding migration of moisture, which is the major cause of microbiological growth including cutting welding/ brazing complete all as per site requirement and directed by Engineer-in-Charge.
Supply and fix in repairs volume control damper made out of galvanized iron or anodized aluminium with overlapping leafs to avoid any leakage from the damper suitable for AHU as per existing at site complete all as directed by Engineer-in-Charge
Supply and fix in repairs manual operated SA damper made out of anodized aluminium with overlapping leafs to avoid any leakage from the damper suitable for AHU as per existing at site complete all as directed by Engineer-in-Charge
Supply and fix in repairs leather type canvas in AHU duct of any size as per existing at site complete all as specified and directed by Engineer-in-Charge
Dismantling carefully complete AHU box panels aluminium structures including fine and pre filters, filter section,return and supply air handling ducts of motor blower including drum, structural steel supports, V belts, chilled water coil drain pan, pulley, cooling coil, inlet and outlet chilled water pipe line, burtterfly valves, drain line, AHU drain pan , inlet and outlet canvas connection and reassembling carefully by replacing all old bearings of motor blowers, V groove pulley, canvas, belts, motor paddles, all hardwares and reshape the pipe lines as per requirement all as per existing at site complete all as specified and directed by Engineer-in-Charge
Supply and fix GI filter frame section 18 gauge for fine filters and refixing all filters as per existing site, including dismantling old GI frame section and directed by Engineer-in-Charge
Supply and fix in repairs including testing of pressure guage suitable for chilled water pipe lines in AHU including all accessories complete all as specified and directed by Engineer-in-ChargeMake :- Fiebig or equivalent as approved by GE
Supply,fabricate and erection of GI sheet 16 gauge base frame for AHU unit including all accessories such as corner, carriage bolt hangers, gasket and appropriate sealant on longitudnal joints etc. including dismantling old GI sheets, complete all as directed & specified by Engineer-in-Charge.
Taking down old unserviable Fan Coil Unit and Supply and Fix Fan Coil Unit with cooling coil made out of copper tubes with finned aluminium 4 rows for 3 TR capacity, reconnecting inlet and outlet chilled water connection, drainage connections and testing for leak test and reconnecting, welding etc and testing on required load complete all as specified and directed by Engineer-in-Charge.
Taking down old unserviable Fan Coil Unit and Supply and Fix Fan Coil Unit with cooling coil made out of copper tubes with finned aluminium 8 rows for 2 TR capacity, reconnecting inlet and outlet chilled water connection, drainage connections and testing for leak test and reconnecting, welding etc and testing on required load complete all as specified and directed by Engineer-in-Charge.
Material & labour for Cleaning of Air handling ducts (GI/Al) internally by using special T&P like robortic arm, air compressor, air jet nozzles, flipper, vaccum pump and a suction blower with hepa filter and check before and after the cleaning all as directed by the Engineer-in-Charge
Taking down old unserviceable MCCB of any size and S & F of MCCB 3P, 415 V, Adjustable type, 25 - 100 Amps with breaking capacity 16KA, Including making suitable fixing arrangement with all connected accessories on existing LT panel of Cooling Tower complete all as specified and directed by Engineer-in-Charge
Taking down old unservicable Contactor of any size at site and S & F of contactor 3P, 415 V, Adjustable type of having capacity 50 Amps with breaking capacity 50KA, Including making suitable fixing arrangement with all connected accessories on existing AHU panel complete all as specified and directed by Engineer-in-Charge
All as per Srl Item No. 30.00 here in before but capacity 32 Amp.
Supply & fix in repairs dry and wet bulb thermo meter. Make- Dimple or as approved by GE
Dismantling old unsrv aluminium armoured cable & supply and laying XLPE insulated, screened, PVC bedded, galvanised steel strip of wire armoured electric cables (heavy duty) of size 10 sqmm X 4 core copper conductor, 1100V grade as per IS incl proper glands on both side for proper earthing complete all as specified and directed by Engineer-in-Charge.
All as per Srl Item No. 32.00 here in before but size 6 sqmm X 4 core.
Repairs/Routine maintenace of Double skin Air Handling Units (Make: Carrier Aircon/ Blue star/Zeco) of minimum capacity 1.5 TR to 66 TR blow type complete with Fan / centrifugal blower, coil section with multirow deep cooling coil, filter section with synthetic fibre incl TEFC induction motor, belt drive pakage, balancing valve gate valve 3-way diverting valve, Y-stainer airvent, temperature & pressure gauge etc for effcient & continious running/operation of AHU and its electric panel board, desktop with other installation/equipment below, lodging of complaint, monitoring of AHU panel board, cleaning of softening plant vessel, its filters, syntax tank, time to time mix evaporated salt for reducing hardness of water and other damages installed at INHS Asvini comprising with following complete all as specified and directed by Engineer-in-Charge:- i) AHUs - 37 Nos ii) RU Units - 09 Nos iii) FCU units - 09 Nos iv) Air Curtains - 08 Nos v) Water Softening plant - 01 Nos
Note: (a) AC mechanic have to attend local complaint, Minor faults, routine cleaning, cleaning of filters. Any number of man power required for carrying out the routine maintenace, servicing & repairs is deemed to be incl in the quoted rates. (b) AC Mechanic must be capable of carrying out any type of maintenance or attending breakdown in above mentioned plants. (d) Incase of any breakdown the additional manpowerr if required will be arranged by contractor without any price adjustment. (e) The cost of replacement of minor parts as mentioned on above shall be deemed to be incl in quoted rates of sch 'A' Item No. 33.00.
All Motor bearing as per existing size & make.
Pump bearing as per existing size & make.
Couplings of Motor
Gland packing graphical coating as per the ground required & size.
Coupling Bush with pin.
V Belt s per existing size & make.
Blower bearing of any size of Motor & pumps.
Misc as nuts, bolts etc
Servogen greese as per required site.
Relay any type & rating.
MCCB, MCB for any type & capacity of Motot/Pumps.
Pressure gauge
Temperature gauge
All type of contactors
Cable glands & Lugs
All motor winding below 5 HP
Minor pipe insulation & duct insulation work - upto 1 mtr.
Taking down old unserviceable Actuator valve, Supply & fixing of new 1/2'' dia Actuator with stainless steel ball valve set complete all as specified and directed by Engineer-in-Charge
All as per item no. 34 but having size 3'' dia
Taking out sealed unit window type AC 1.5 ton of any make and taking out old burnt compressor and supply and fix in replacement new sealed / rotary compressor suitable for 1.5 Ton capacity AC and connecting up suction and discharging pipe line with gas welding and duly charged with fresh Mafron gas complete all as specified and directed by Engineer-in-Charge. Make : Voltas/USHA/Shriram/Bluestar/Samsung/Hitachi/Videocon/LG/Carrier/General/Onida etc as per existing make at site
All as per item No 35.00 above but suitable for 2 Ton capacity complete all as specified and directed by Engineer-in-Charge
All as per item No 35.00 above but suitable for Split type AC 1.5 Ton capacity complete all as specified and directed by Engineer-in-Charge
All as item No 35.00 above but suitable for split type AC 2.0 Ton capacity complete all as specified and directed by Engineer-in-Charge
All as per item No 35.00 above but suitable for Refrigerator 165/190/280/310 Ltrs. Capacity complete all as specified and directed by Engineer-in-Charge
All as per item No 35.00 above but suitable for water coolers 40/60/80/100/150 Ltrs. Capacity complete all as specified and directed by Engineer-in-Charge
Material and labour for detecting the gas leakage from window type AC 1.5 ton capacity of any make and type including pressure testing,rectification, vaccumising, charging fresh gas R-12/ R-22 as exists, testing and commissioning complete all as specified and directed by Engineer-in-Charge
All as per item No 41.00 above but 2.0 Ton capacity window type AC complete all as specified and directed by Engineer-in-Charge
All as per item No 41.00 above but of 1.5/ 2.0 ton capacity split type AC complete all as specified and directed by Engineer-in-Charge
All as per item No 41.00 above but of 40/100/150ltrs. Capacity water cooler / refrigerator complete all as specified and directed by Engineer-in-Charge
Supply and fix in repairs blower fan motor of 1.0/ 1.5/ 2.0 Ton capacity AC of existing make including testing complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repairs fan motor suitable for water cooler of any Capacity including testing complete all as specified and directed by Engineer-in-Charge
Taking out AC 1.0/ 1.5/ 2.0 ton capacity of any make from its original location removing the dust from body with blower cleaning the condenser & cooling coil by using water and caustic soda, paintining the base tray with one coat of black synthetic enamel paint checking all the connections including functioning of metal clad socket/ DP switch, function of relay capacitors, overload protector, thermostat, fan motor blade, / blower drum etc oiling/greasing of fan motor checking serviceability changing the air filter woolen felt for air tightening complete & refixing it in its original place including commissioning and testing complete all as specified and directed by Engineer-in-Charge.
Taking down corroded body base tray of window type AC 1.0Ton/ 1.5Ton/ 2.0Ton capacity and replacement of body base tray made out of MS sheet 18 SWG and other portion with 20 SWG including motor mounting frame fixed with and including nuts and bolts of suitable size including painting with two coats of synthetic enamel paint over one coat of red oxide primer and necessary insulationcomplete all as specified and directed by Engineer-in-Charge.
Material and labour for preparation of old painted surfaces of Water cooler any capacity by complete scraping old painting an applying two coat of synthetic enamel painting on outer surface (spray painting) as per existing colour and black colour on bottom portion such as compressor etc. over a coat of red oxide primer complete all as specified and directed by Engineer-in-Charge.
Material and labour for preparation of old painted surfaces of refrigerator any capacity by complete scraping old painting an applying two coats of synthetic enamel painting on outer surface (spray painting) as per existing colour and black colour on bottom portion such as compressor etc. over a coat of red oxide primer complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repairs fan blade of motor suitable for water cooler of any Capacity including testing complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repairs fan blade of motor suitable for window /split type AC 1.0Ton/ 1.5Ton/ 2.0 Ton capacity including testing complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repairs blower drum suitable for window type AC 1.0Ton/ 1.5Ton/ 2.0 Ton capacity including testing complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repairs outer cover for window type Air conditioner of any capacity and size made out of aluminium sheet 20SWG complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repairs front cover grill suitable for window type Air conditioner 1.0 Ton/ 1.5 Ton/ 2.0 Ton capacity AC of existing make complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repairs starting capacitor 60-80 mfd complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repairs starting capacitor 80-100 mfd complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repairs starting capacitor 100-120mfd complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repairs running capacitor 25MFD complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repairs running capacitor 36MFD complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repairs relay suitable for window / split type AC of 1.0Ton/ 1.5Ton/ 2 Ton capacity complete all as specified and directed by Engineer-in-Charge.
All as per item No 62.00 above but rotary type complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repairs thermostat switch suitable for window type/ split type AC of capacity 1.0Ton/ 1.5Ton/ 2.0Ton capacity complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repairs thermostat switch suitable for refrigerator of any capacity complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repairs thermostate switch suitable for water cooler of any capacity complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repairs Air filter suitable for window type/ split AC of any capacity and type complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repairs over load protector suitable for window type AC complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repairs electric bulb suitable of refrigerator of any capacity screw type/ pin type complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repairs sheet metal enclosure with 2 pin earth plug and socket complete with single pole MCB of 20 Amps complete all as specified and directed by Engineer-in-Charge.
Taking down carefully split type AC of capacity 1.5/ 2.0 ton & refixing in new location including provision of frame work of MS angle iron/ flat iron for indoor unit and outdoor unit as per manufacturers instructions duly painted with two coats of synthetic enamel paint over a coat of zinc chrome primer, making hole in the wall for pipes and making good disturbed surfaces as per existing surface and making connections complete all as specified and directed by Engineer-in-Charge.
Supply fixing and clamping jointing copper tubing of standard size for suction line and for liquid discharge line duly insulated with and including nitrile rubber insulation material including making hole in wall for passing through and making good the disturbed surface complete all as specified and directed by Engineer-in-Charge.
Supply and lay cable PVC insulated PVC unsheathed, multistranded, 1100 volts grade (ISI marked) 3 core 4 Sq mm with copper conductor suitable for indoor unit to out door unit including taking out old cable complete all as specified and directed by Engineer-in-Charge.
Supply and lay PVC flexible pipe 5/8" dia, heavy duty for drain out condensing water of split AC including cutting of floor/ making hole in wall and making good after laying of pipe to match the existing surface complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repairs push cock/ lifting cock for water cooler of any capacity complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repairs GI water tray 2mm thick for window type AC any capacity with out let system connection provided with PVC pipe of 20mm dia up to 3meter length connecting to drain pipe complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repairs PVC drain pipe 25mm bore as out let drain, fixed to wall with necessary saddles or laid under floor complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repairs magnetic gasket suitable for refrigerator of 165/ 286/ 310ltrs capacity complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repairs relay suitable for water cooler of any capacity complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repairs relay suitable for refrigerator of any Capacity complete all as specified and directed by Engineer-in-Charge.
Taking down carefully window type AC of capacity 1.5/ 2.0 ton & refixing in new location after cutting out existing wall, widow grill, existing window frame for making suitable space to accommodate window type AC and making frame with 2nd class hard wood scantling of size 50mm x 50mm for fixing of outer cover of AC & supporting structure made out of 40mm x 40mm x 5mm thick MS angle iron duly grouted in wall & closing the open space around ACs with the help of 6mm thick plywood exterior grade to close air leakage, tightening with wooden fillet and painting to wooden structure & steel structure with two coats of synthetic enamel paint over a coat of primer and making all connections complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repairs blower motor capacitor 4MFD complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repairs blower motor capacitor 6MFD complete all as specified and directed by Engineer-in-Charge.
Supply and fix of Float valve suitable for Water cooler of any capacity incl taking down complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repairs electronic circuit (PCB) suitable for split type AC of any capacity complete all as specified and directed by Engineer-in-Charge.
Repairs to PCB of any capacity split AC by dismantling from indoor units carefully by diconnecting all internal communication cables and sensor supply, replace/ soldering damaged chip, electonic capacitors / transmitters/inductors/switches with new components and re install and connect to the split AC & testing complete all as specified and directed by Engineer-in-Charge.
Repair/replacement of indoor unit of split type AC 2.0 TR capacity having 5 star rating complete with all accessories such as installation plate with screws, blower motor, swing motor, filter and PCB etc duly prewired including reconnecting of existing refrigerant piping, electrical connections, drain pipe etc and testing after taking out old one complete all as specified and directed by Engineer-in-Charge.
Repair/replacement of indoor unit of split type AC 1.5 TR capacity having 5 star rating complete with all accessories such as installation plate with screws, blower motor, swing motor, filter and PCB etc duly prewired including reconnecting of existing refrigerant piping, electrical connections, drain pipe etc and testing after taking out old one complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repairs condensor coil made out of copper pipe and aluminium fins suitable for Air conditioners/ water coolers including leakage checking, gas charging and testing complete all as specified and directed by Engineer-in-Charge.
Supply & fix in repairs of sensor remote handset suitable for 1.5/2.0 Ton capacity split type AC complete all as specified and directed by Engineer-in-Charge.
Taking out old unserviceable cooling coil of window/split type AC any capacity and any make with sins cutting in let outlet connecting copper pipe and providing new cooling coil with sins and connecting in let out let copper pipe by bracing and replacement of nut bolts complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement Contactor of split type AC any capacity complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement suction & liquid line valve of size (5/8"&1/4")/(5/8"&3/8") suitable for split type AC complete all as specified and directed by Engineer-in-Charge.
Supply & fix Condensing unit Bracket of any size and type suitable for supporting to out door unit of split type AC including nut, bolts & washers complete all as specified and directed by Engineer-in-Charge.
Repair/replacement of outdoor unit of split type AC 1.5 TR cap having 5 star rating complete with all accessories such as hermetically sealed compressor, condenser unit, capacitor, relays, fan motor etc duly prewired including reconnecting of existing refrigerant piping, electrical connections, drain pipe etc and testing after taking out old one complete all as specified and directed by Engineer-in-Charge.
Repair/replacement of outdoor unit of split type AC 2.0 TR cap having 5 star rating complete with all accessories such as hermetically sealed compressor, condenser unit, capacitor, relays, fan motor etc duly prewired including reconnecting of existing refrigerant piping, electrical connections, drain pipe etc and testing after taking out old one complete all as specified and directed by Engineer-in-Charge.
Maintenance & complete servicing of cold/cool room units by electrically disconnecting the units and cleaning the compressor, condensor , piping suction/ discharge suction, fan motor, cooling coils etc. and connected accessories with the help of blower unit, cleaning the same with water and caustic soda for condensor and piping unit, painting the cooler base by scrapping out rusted particle and apply two coats of anticorrosive black paint at corroded portion, tighten all nut bolts, screws etc checking the door beding, electrical controls of the cooling units rectify where necessary, defrost the system dry &disinfect the inner portion using disinfect material and refixing in original site and testing complete for 04 Nos units of any capacity complete all as specified and directed by Engineer-in-Charge.
Maintenance & complete servicing of Deep freezer units 04 Nos by electrically disconnecting the units and cleaning the compressor, condensor , piping suction/ discharge suction, fan motor, cooling coils, cooler body and connected accessories with the help of blower unit, cleaning the same with water and caustic soda for condensor and piping unit, painting the cooler base by scrapping out rusted particle and apply two coats of anticorrosive black paint at corroded portion, tighten all nuts,bolts, screws etc checking the door beding, electrical controls of the cooling units rectify where necessary, defrost the system dry &disinfect the inner portion using disinfect material and refixing in original site and testing complete for 04 Nos units of any capacity complete all as specified and directed by Engineer-in-Charge.
Maintenance & complete servicing of Mortury units by electrically disconnecting the units and cleaning the compressor, condensor , piping suction/ discharge suction, fan motor, cooling coils, cooler body and connected accessories with the help of blower unit, cleaning the same with water and caustic soda for condensor and piping unit, painting the cooler base by scrapping out rusted particle and apply two coats of anticorrosive black paint at corroded portion, tighten all nuts bolts, screws etc checking the door beding, electrical controls of the cooling units rectify where necessary, defrost the system dry & disinfect the inner portion using disinfect material and refixing in original site and testing complete for 02 Nos units of any capacity complete all as specified and directed by Engineer-in-Charge.
Taking down the defective compressor unit and supply and installing of new compressor of same type for cool room (by dismantling the unserviceable compressor from composite unit by cutting out copper tubing and electrical connection etc) of capacity 1.5 ton Make- Dan foss, kirloskar, carrier aircon or blue star as suitable at site including bracing work,leak testing vacuumining Gas charging & testing the site, at required temperature as designed complete all as specified and directed by Engineer-in-Charge.
Taking down the defective compressor unit and supply and installing of new compressor of same type for cold room (by dismantling the unserviceable compressor from composite unit by cutting out copper tubing and electrical connection etc) of capacity 3.5 ton Make- Dan foss, kirloskar, carrier aircon or blue star as suitable at site including bracing work,leak testing vacuumining Gas charging & testing the site, at required temperature as designed complete all as specified and directed by Engineer-in-Charge.
Taking down unserviceable compressor supply and installing the new compressor unit of 2 TR capacity for mortury cabins make- Kirloskar, Carrier, Aircon or Blue star as suitable at site including brazing work vacuumining gas charging leak testing and commissioning the unit to the design temperature complete all as specified and directed by Engineer-in-Charge. Note for items 100, 101 and 102: Leak testing and gas charging for the units replaced with new compressor is included in the unit rate quoted) Make:-Emerson or as approved by GE.
Material and labour for carrying out Leakage testing of cold storage/cool room/mortury cabinets/ deep freezers by vacuuming the plant with vacum pump and filling nitrogen gas seperately in compressor and condensor piping etc finding the leakage and rectifying, providing of gaskets packing/brazing, leaking piping where necessary as required for smooth functioning of the plant complete all as specified and directed by Engineer-in-Charge.. (NOTE- Refrigerant gas will be measured seperately)
Material and labour for rewinding of blower motor 0.1 to 0.25 hp with same gauge and turns of copper wire, varnishing and testing of motor complete all as specified and directed by Engineer-in-Charge.
Removing old unserviceable power contactor ML-1.5 and supply & fixing new power contactor ML-1.5, 4pole complete all as specified and directed by Engineer-in-Charge.
Material and labour for LP/HP Cut out after removing to unserviceable LP/HP cut out complete all as specified and directed by Engineer-in-Charge. Make : Danfoss or as approved by GE.
Replacement of running capacitor 25 MFD to 45 MFD after removing old unserviceable running capacitor complete all as specified and directed by Engineer-in-Charge. make : Usha/ Siemens/ Epcos or as approved by GE.
Replacement of starting capacitor 60MFD to 120MFD after removing old unserviceable capacitor complete all as specified and directed by Engineer-in-Charge.
Material and labour for oil pressure cut out controls for compressor including taking down old one complete all as specified and directed by Engineer-in-Charge.. Make: MP 55 Indofoss or as approved by GE.
Removing of old unserviceable heating coil as per suitable dia and liquid length with super lone insulation over the pipe for drainage of cold room complete all as specified and directed by Engineer-in-Charge.
Replacement of old unserviceable thermostat with new thermostat suitable (-)18 deg C to (-) 23deg C cold storage plant complete all as specified and directed by Engineer-in-Charge.
Removing old unserviceable pilot solenoid valve assembly and providing new pilot solenoid valve assembly for cold room complete all as specified and directed by Engineer-in-Charge.
Material and labour for replacement of old unserviceable temprature indicator complete all as specified and directed by Engineer-in-Charge.
Material and labour for expansion valve suitable for -18degC to -23degC after removing unserviceable expansion valve in cold room complete all as specified and directed by Engineer-in-Charge. Make :- Danfoss or as approved by GE
Supply and fix single phase preventor complete all as specified and directed by Engineer-in-Charge. Make: Minilec or as approved by GE
Removing old unserviceable timer, supply and fix new timer of same make and capacity complete all as specified and directed by Engineer-in-Charge.
Removing old unserviceable over load relay assembly and supply fixing new overload relay assembly of same make and capacity complete all as specified and directed by Engineer-in-Charge.
Supply and fix flexible cord type heater 60watt for cold room complete all as specified and directed by Engineer-in-Charge.
Removing the worn out control wiring complete, rewiring with suitable copper conductor cable replacing the lugs starter to compressor motor, fan motor timer HP/LP cut , thermostat complete interlock wiring, checking the complete function of timer, heaters, relays, HP/LP cut outs, thermostat cut out and inter lock wiring system, testing on load and all wiring shall be mounted on cable tray complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repairs ball valve of cast steel flange type of size 25mm bore from the liquid line after pumping down the refrigerant and test for leakages complete all as specified and directed by Engineer-in-Charge.
Material and labour for replacement of unserviceable / defective existing ampere meter digital type 0-30 Amps with CT of size 96 x 96mm complete all as specified and directed by Engineer-in-Charge.
Material and labour for replacement of unserviceable / defective existing Volt meter digital type 0-500 Volts with PT of size 96 x 96mm complete all as specified and directed by Engineer-in-Charge.
Removing old unserviceable condensor coil fan motor with blade assembly and providing new condensor coil fan motor with blade complete suitable for cold room outer unit complete all as specified and directed by Engineer-in-Charge.
Removing old unserviceable cooling coil fan motor with blade assembly and providing new cooling coil fan motor with blade complete suitable for cold room inner unit complete all as specified and directed by Engineer-in-Charge.
Taking out old unserviceable condensor and supply & fix new condensor made out of copper pipe and aluminium fins suitable for cold/ cool room including gas charging, leakage checking and testing complete all as specified and directed by Engineer-in-Charge.
Supply & fix in replacement Filter Drier for size 5/8 or 3/8 inch flare size suitable for cold storage/cool room complete all as specified and directed by Engineer-in-Charge.. Make: Sporlan or as approved by GE
Supply and fix as required at site compressor oil after draining out old oil flushing the compressor chamber and filling oil to the requisite level for cooling equipment complete all as specified and directed by Engineer-in-Charge.
Supply and charge fresh R-22 Mafron refrigerant Gas as required in the cool room/cold storage/ Mortuary/ deep freezer cabinets complete all as specified and directed by Engineer-in-Charge.
Supply & installation for cable tray 300 mm with 50 mm collar height of 16 SWG thickness with cover suitable for laying refrigerant pipes, power & control cables, incl support clamps, rods, bolts, nuts, washers, fastners etc complete all as specified and directed by Engineer-in-Charge.
Supply & fix in repair wire netting of galvanised steel wire 24 gauge fixed wit tinned tacks of wire staples mesh size 12 mm aparture over entire duct insulation wit 50mm overlap for preventing Rat bites complete all as specified and directed by Engineer-in-Charge.
Supply & Filling, Testing and commissioning for Refrigerant Gas R-404a complete all as specified and directed by Engineer-in-Charge.
Taking down the defective compressor unit and supply and installing of new compressor of same type for ductable AC (by dismantling the unserviceable compressor from composite unit by cutting out copper tubing and electrical connection etc) of capacity 8.5 ton Make- Emerson, Dan foss, kirloskar, carrier aircon or blue star as suitable at site including bracing work,leak testing vacuumining Gas charging & testing the site, at required temperature as designed complete all as specified and directed by Engineer-in-Charge.
All as per item no. 132, But having capacity 5.5 TR.
All as per item no. 132, But having capacity 11.0 TR.
Material and labour point wiring with 4 sqmm (Nominal area) PVC insulated & unsheathed multistranded FRLSH copper conductor cable (using colour code as per IS), 1100 Volt grade drawn through incl suitable size surface PVC cassing capping (ISI marked) with all accessories & terminated in & incl surface PVC modular box including cover plate and frame of suitable size incl 4 sqmm size PVC insulated & unsheathed multistranded FRLSH copper conductor cable for continious earth conductor (using green colour) and connecting to earth dolly for one industrial metal clad power socket on Independent board for AC complete all as specified and directed by Engineer-in-Charge.
Material and labour for Writing letters or figures (Block, Roman, Italic or Indian) not exceeding 30 cm high complete all as specified and directed by Engineer-in-Charge.
Supply and charge fresh R-32 Mafron refrigerant gas as required in the cool room/cold storage/ Mortuary Cabinets/Acs complete all as specified and directed by Engineer-in-Charge.
Supply and charge fresh R-134 Mafron refrigerant gas as required in the cool room/cold storage/ Mortuary Cabinets/Acs complete all as specified and directed by Engineer-in-Charge.
somnath engineering corporation
sapana enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .