Execution of balance works like construction of dormitory, sports gallery, toilet facilities, electrical works, etc., in connection with the construction of Dormitory (G+1) at Railway Stadium, Sambalpur.
04-eT-SETT-SBP-26
04-eT-SETT-SBP-26
Open
7 Months
Sambalpur, Odisha
₹0
₹7.0 L
25 May 2026
25 May 2026
1 Jun 2026
conditions as given in attached special conditions)
Item- 01 See item break up for details
S No. Item No Description of Item Unit Qty Rate Amount
1 01 Conceal wiring for Light/ Fan/ Exhaust Point 300.00 436.01 130803.00
Fan/Call Bell/ Points by 1.5sq mm FRLS cu.
Wire with modular switches through PVC
pipe with supply of materials.
SAMBALPUR DIVN-ENGG/ECOR
2 02 Concealed wiring of socket point 5/3 pin 6 Point 75.00 119.91 8993.25
amp with copper wire and modular switch
and socket with supply of materials.
3 03 Concealed wiring of socket point 5/3 pin 16 Point 35.00 357.97 12528.95
amp with copper wire and modular switch
and socket with supply of materials.
PVC (FRLS)insulated copper Wire
5 05 Concealed wiring of sub main with 2(1x2.5 Metre 800.00 114.11 91288.00
sq.mm) + 1x(1.5 sq. mm) PVC (
FRLS)insulated copper Wire
6 06 Concealed wiring of sub main with 2(1x4 Metre 400.00 124.28 49712.00
sq.mm) + 1x (2.5 sq. mm) PVC
(FRLS)insulated copper Wire
7 07 Concealed wiring of sub main with 2(1x6 Metre 200.00 169.78 33956.00
sq.mm) + 1x(2.5 sq. mm) PVC (
FRLS)insulated copper Wire.
8 08 Supply, Erection, testing & commissioning Numbers 2.00 250.99 501.98
of 2-way MCB DB.
9 09 Supply, Erection, testing & commissioning Numbers 2.00 659.65 1319.30
of 4-way MCB distribution board.
10 10 Supply, Erection, testing & commissioning Numbers 8.00 980.71 7845.68
of 8-way MCB distribution board.
11 11 Supply & erection of ISI marked MCB 6- Numbers 2.00 446.96 893.92
32Amp MCB DP, 10KA.C-curve
12 12 Supply, erection, testing & commissioning Numbers 72.00 219.89 15832.08
of ISI marked MCB 6-32Amp MCB
SP,10KA.C-curve
14 14 Fixing and testing of AC ceiling fan. Numbers 61.00 34.74 2119.14
15 15 Supply of 20 W, LED type tube light fitting Numbers 112.00 254.78 28535.36
17 17 Supply of wall lamp with 10W LED lamp Numbers 32.00 200.00 6400.00
18 18 Supply of 4MLED Footlight warm white 3 Numbers 12.00 634.85 7618.20
19 19 Fixing of LED type tube light fitting Numbers 169.00 42.22 7135.18
20 20 Supply & fixing of LED down light fitting Each 864.00 70.92 61274.88
complete with luminaire. (Note: The unit is
taken as WATT & for estimation 18-watt
rating has been considered)
21 21 Supply of 200 mm BLDC Exhaust fan/Fresh Numbers 15.00 1967.20 29508.00
22 22 Erection, testing and commissioning of Numbers 15.00 184.22 2763.30
23 23 Supply of wall fan 400mm sweep suitable Numbers 3.00 2041.16 6123.48
for 240V, 50Hz, AC.
24 24 Fixing of wall fan 400mm sweep suitable for Numbers 3.00 34.74 104.22
240V, 50Hz, AC.
25 25 Supply, Design, Fabrication of LT outdoor Numbers 1.00 107287.57 107287.57
feeder pillar having 1x160- Amp (suitable
for Thermal adjustment range of 70-100%),
4Pole MCCB (,16KA as in coming and 4x63A
MCCB 4 pole,1 nos 32A A MCB 4P ,10KA as
outgoing complete with copper Bus bar,
Digital multifunctional meter and other
allied accessories. (For MCCB Ics=100%Icu)
26 26 Design, supply, fabrication of LT panel Numbers 2.00 35402.63 70805.26
Board having 1x 63 Amp, 4Pole MCCB,16KA
as in coming and 8x32 A MCB DP,10KA as
outgoing complete with copper Bus bar, and
other allied accessories like voltmeter,
ammeter selector switch.( incoming MCCB
should be suitable for Thermal adjustment
range of 70-100% load)
SAMBALPUR DIVN-ENGG/ECOR
27 27 Erection of LT Out door/ Indoor feeder Numbers 3.00 3720.43 11161.29
pillar/panel of different size on wall or
28 28 Laying of cable in air/on wall pole/through Metre 680.00 22.45 15266.00
GI pipe/culvert/cable trench/HDPE pipe etc.
30 30 Laying of single cable across road/track as Metre 20.00 396.29 7925.80
per Rly appd drawing
mm &ID=51 mm nominal) DWC HDPE pipe
ISI marked along with all accessories etc. as
per CPWD specification.
32 32 Provision of G.I pipe earthing as per CEE Numbers 4.00 3030.33 12121.32
approved drawing.
34 34 Supply of 45-watt LED outdoor fitting. Numbers 6.00 2060.34 12362.04
35 35 Erection, testing & commissioning of LED Numbers 6.00 263.71 1582.26
outdoor fitting on Building wall/ pole etc.
Item Breakup - A-Execution of CPWD's DSR-2023 items
gms Providing and fixing PTMT pillar cock of 18.56 approved quality and colour. 18.56.2 15 mm nominal bore, 125 mm long foam Each 12 224.1 2689.2 51 flow, weighing not less than 120 gms Providing and fixing PTMT grating of 18.58 approved quality and colour. 18.58.1 Circular type 52 18.58.1.1 100 mm nominal dia Each 34 37.6 1278.4 18.59S AIR VALVE & WATER METER (BULK TYPE) 18.64 Providing and fixing PTMT swivelling Each 12 121.4 1456.8 53 shower, 15 mm nominal bore, weighing not less than 40 gms 21.0 ALUMINIUM WORK 21.1S General Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required 21.1 EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, panelling and dash fasteners to be paid for separately) : 21.1.1 For fixed portion 21.1.1.1 Anodised aluminium (anodised transparent Kg 200 495.05 99010 or dyed to required shade according to IS: 54 1868, Minimum anodic coating of grade AC 15) For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings 21.1.2 wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) 21.1.2.1 Anodised aluminium (anodised transparent Kg 400 598.6 239440 or dyed to required shade according to IS: 55 1868, Minimum anodic coating of grade AC 15) Total 27530747.26 Schedule C-Execution of Electrical Works (To be read together with explanatory notes, terms &
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
SCElectricalWorks.pdf
ATTACHMENT
GCDormitory.pdf
ATTACHMENT
SCDormitory.pdf
ATTACHMENT
Download all tender documents and submit your bid