Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.0 LAccepted-AOC 1 PNETH CHOORI CHAMBA CHAMBA HIMACHAL PRADESH 176311 UDYAM HP 02 0007745 | CHAMBA | HIMACHAL PRADESH | 176311 | ₹2.0 L Quoted ₹2.1 L | L1 | Accepted-AOC Accepted as bidder found L1 |
| 2 | L2₹2.2 LRejected-AOC | ₹2.2 L | L2 | Rejected-AOC Rejected as bidder found L2 |
| 3 | L3₹20.9 LRejected-AOC VILL ODDI P O KIAR TEHSIL THEOG DISTT SHIMLA H P | ₹20.9 L | L3 | Rejected-AOC Rejected as bidder found L3 |
| Sl No | Description | Qty | Unit | Sandeep Verma L3 | SAnjeev Kumar L1 | Sandeep L2 |
|---|---|---|---|---|---|---|
| 1.00 | Providing horizontal spindel horizontal/radial split casing/end section (back pull out arrangment) single/double/multistages Sludge pump or combination of pumps, in series/parallel of recommended make such as Mather and Platt/ KSB/Becon wire/BE/Kirloskar/ Tyoti as per BIS 1520-1980 with upto date ammendements read with IS-9137-1978 or latest eddition suitable for lifting Clear water for under mentioned charterstic with bronze, shaft of steel grade- with cast iron casing coupled directly through a flexible coupling on a common C.I/cast steel base plate (base plate to be from the manufacturers of the pumping unit only) to Slip/Ring/Squarrel cage screen protected drip proof induction motor od standered make such as Kirlosker/Crompton/Bhel/NGEF/GEC/ SIEMEN/JYOTI/ABB suitable for operation on 415 (+)/(-) 5% vilts, 50 cycles/second, 3 Phase AC electrical supply. The power of electrical motor should be atlest 10% in exess of the maximum power required by the pump in the operation range of (+) 10% and (-) 25% of duty point head. The motor should be as per IS: 325-1978 with upto date ammendements read with IS: 900-1972. it should include cost of bearing nuts, bolts and pointing etc. and should meet the following requirements:- (i) Discharge (Q) 15.97 LPS Cum/Hr per set (ii) Total Dynamic Head : 25.48 mtr (a) LWL in sump well (h):- mtrs. (b) Shaft level:- mtrs ( c) Leavel at dicsharge points:- metrs. (d) Suction lift:- 3.00 mtrs (e) Residual head :- 3.00 mtrs (f) Static head :- 21 mtrs. (iii) Rising Main (a) Length 55 mtrs (b) Dia:- 150 mm (iv) Pumping Hours 8 hours. (v) Altitude of Installation above MSL - mtrs (vi) Characterstics of water (a) Temperature ०C (b) Abient Temperature ०C ( c) Turbidity Clear water JTU (d) Alkalanity Mg/CA CO3 (e) Size of the solids Mm (f) other | 10 | HP | 2,09,000 ₹20.9 L | 21,500 ₹2.1 L | 22,200 ₹2.2 L |
Tender Value
₹2 L
EMD Value
₹4,000
Closing Date
3 Oct 2025, 11:00 amClosed
Executive Engineer Jal Shakti Division Matiana
O/o Executive Engineer Jal Shakti Division Matiana
S and F of Kilosker Make Sludge pump with allied accessories
2025_HPIPH_115707_1
JS-DM-CB-Tender-25-4985-5034-1
Open Tender
Pumps/Motors
60 days
Theog
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
EE Matiana
₹4,000
17 Dec 2025
23 Sept 2025
3 Oct 2025
23 Sept 2025
3 Oct 2025
23 Sept 2025
Amount
Providing horizontal spindel horizontal/radial split casing/end section (back pull out arrangment) single/double/multistages Sludge pump or combination of pumps, in series/parallel of recommended make such as Mather and Platt/ KSB/Becon wire/BE/Kirloskar/ Tyoti as per BIS 1520-1980 with upto date ammendements read with IS-9137-1978 or latest eddition suitable for lifting Clear water for under mentioned charterstic with bronze, shaft of steel grade- with cast iron casing coupled directly through a flexible coupling on a common C.I/cast steel base plate (base plate to be from the manufacturers of the pumping unit only) to Slip/Ring/Squarrel cage screen protected drip proof induction motor od standered make such as Kirlosker/Crompton/Bhel/NGEF/GEC/ SIEMEN/JYOTI/ABB suitable for operation on 415 (+)/(-) 5% vilts, 50 cycles/second, 3 Phase AC electrical supply. The power of electrical motor should be atlest 10% in exess of the maximum power required by the pump in the operation range of (+) 10% and (-) 25% of duty point head. The motor should be as per IS: 325-1978 with upto date ammendements read with IS: 900-1972. it should include cost of bearing nuts, bolts and pointing etc. and should meet the following requirements:- (i) Discharge (Q) 15.97 LPS Cum/Hr per set (ii) Total Dynamic Head : 25.48 mtr (a) LWL in sump well (h):- mtrs. (b) Shaft level:- mtrs ( c) Leavel at dicsharge points:- metrs. (d) Suction lift:- 3.00 mtrs (e) Residual head :- 3.00 mtrs (f) Static head :- 21 mtrs. (iii) Rising Main (a) Length 55 mtrs (b) Dia:- 150 mm (iv) Pumping Hours 8 hours. (v) Altitude of Installation above MSL - mtrs (vi) Characterstics of water (a) Temperature ०C (b) Abient Temperature ०C ( c) Turbidity Clear water JTU (d) Alkalanity Mg/CA CO3 (e) Size of the solids Mm (f) other
Sandeep (BID ID -564773)
Sandeep Verma (BID ID -564914)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid