Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.0 LAccepted-AOC 0 MATADIN KAKRAHI KAKRAHI BHARTHANA ETAWA ETAWAH UTTAR PRADESH 206242 | ETAWAH | UTTAR PRADESH | 206242 | L1 | Accepted-AOC Accepted as bidder found L1 | |
| 2 | L2₹2.2 L+₹7,000 (3.26%)Rejected-AOC | L2 | Rejected-AOC Rejected as bidder found L2 | |
| 3 | L3₹20.9 L+₹18.8 L (872.1%)Rejected-AOC VILL ODDI P O KIAR TEHSIL THEOG DISTT SHIMLA H P | L3 | Rejected-AOC Rejected as bidder found L3 |
| Sl No | Description | Qty | Unit | Sandeep Verma L3 | SAnjeev Kumar L1 | Sandeep L2 |
|---|---|---|---|---|---|---|
| 1.00 | Providing horizontal spindel horizontal/radial split casing/end section (back pull out arrangment) single/double/multistages Sludge pump or combination of pumps, in series/parallel of recommended make such as Mather and Platt/ KSB/Becon wire/BE/Kirloskar/ Tyoti as per BIS 1520-1980 with upto date ammendements read with IS-9137-1978 or latest eddition suitable for lifting Clear water for under mentioned charterstic with bronze, shaft of steel grade- with cast iron casing coupled directly through a flexible coupling on a common C.I/cast steel base plate (base plate to be from the manufacturers of the pumping unit only) to Slip/Ring/Squarrel cage screen protected drip proof induction motor od standered make such as Kirlosker/Crompton/Bhel/NGEF/GEC/ SIEMEN/JYOTI/ABB suitable for operation on 415 (+)/(-) 5% vilts, 50 cycles/second, 3 Phase AC electrical supply. The power of electrical motor should be atlest 10% in exess of the maximum power required by the pump in the operation range of (+) 10% and (-) 25% of duty point head. The motor should be as per IS: 325-1978 with upto date ammendements read with IS: 900-1972. it should include cost of bearing nuts, bolts and pointing etc. and should meet the following requirements:- (i) Discharge (Q) 15.97 LPS Cum/Hr per set (ii) Total Dynamic Head : 25.48 mtr (a) LWL in sump well (h):- mtrs. (b) Shaft level:- mtrs ( c) Leavel at dicsharge points:- metrs. (d) Suction lift:- 3.00 mtrs (e) Residual head :- 3.00 mtrs (f) Static head :- 21 mtrs. (iii) Rising Main (a) Length 55 mtrs (b) Dia:- 150 mm (iv) Pumping Hours 8 hours. (v) Altitude of Installation above MSL - mtrs (vi) Characterstics of water (a) Temperature ०C (b) Abient Temperature ०C ( c) Turbidity Clear water JTU (d) Alkalanity Mg/CA CO3 (e) Size of the solids Mm (f) other | 10 | HP | 2,09,000 ₹20,90,000 | 21,500 ₹2,15,000 Lowest | 22,200 ₹2,22,000 |
Tender Value
₹2 L
EMD Value
₹4,000
Closing Date
3 Oct 2025, 11:00 amClosed
Executive Engineer Jal Shakti Division Matiana
O/o Executive Engineer Jal Shakti Division Matiana
S and F of Kilosker Make Sludge pump with allied accessories
2025_HPIPH_115707_1
JS-DM-CB-Tender-25-4985-5034-1
Open Tender
Pumps/Motors
Item Rate
60 days
Theog
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
EE Matiana
₹4,000
17 Dec 2025
23 Sept 2025
3 Oct 2025
23 Sept 2025
3 Oct 2025
23 Sept 2025
Amount
Providing horizontal spindel horizontal/radial split casing/end section (back pull out arrangment) single/double/multistages Sludge pump or combination of pumps, in series/parallel of recommended make such as Mather and Platt/ KSB/Becon wire/BE/Kirloskar/ Tyoti as per BIS 1520-1980 with upto date ammendements read with IS-9137-1978 or latest eddition suitable for lifting Clear water for under mentioned charterstic with bronze, shaft of steel grade- with cast iron casing coupled directly through a flexible coupling on a common C.I/cast steel base plate (base plate to be from the manufacturers of the pumping unit only) to Slip/Ring/Squarrel cage screen protected drip proof induction motor od standered make such as Kirlosker/Crompton/Bhel/NGEF/GEC/ SIEMEN/JYOTI/ABB suitable for operation on 415 (+)/(-) 5% vilts, 50 cycles/second, 3 Phase AC electrical supply. The power of electrical motor should be atlest 10% in exess of the maximum power required by the pump in the operation range of (+) 10% and (-) 25% of duty point head. The motor should be as per IS: 325-1978 with upto date ammendements read with IS: 900-1972. it should include cost of bearing nuts, bolts and pointing etc. and should meet the following requirements:- (i) Discharge (Q) 15.97 LPS Cum/Hr per set (ii) Total Dynamic Head : 25.48 mtr (a) LWL in sump well (h):- mtrs. (b) Shaft level:- mtrs ( c) Leavel at dicsharge points:- metrs. (d) Suction lift:- 3.00 mtrs (e) Residual head :- 3.00 mtrs (f) Static head :- 21 mtrs. (iii) Rising Main (a) Length 55 mtrs (b) Dia:- 150 mm (iv) Pumping Hours 8 hours. (v) Altitude of Installation above MSL - mtrs (vi) Characterstics of water (a) Temperature ०C (b) Abient Temperature ०C ( c) Turbidity Clear water JTU (d) Alkalanity Mg/CA CO3 (e) Size of the solids Mm (f) other
Sandeep (BID ID -564773)
Sandeep Verma (BID ID -564914)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .