Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.5 LAccepted-AOC A 63 ELDECO COUNTY PHASE II RAJGARH JHANSI U P 284135 | JHANSI | JHANSI | UTTAR PRADESH | 284135 | L1 | Accepted-AOC Being lowest bidder | |
| 2 | L2₹8.0 L+₹19,770 (2.55%)Rejected-Finance | L2 | Rejected-Finance Not become lowest bidder | |
| 3 | L3₹8.5 L+₹78,350 (10.1%)Rejected-Finance | L3 | Rejected-Finance Not become lowest bidder | |
| 4 | L4₹8.8 L+₹1.0 L (13.5%)Rejected-Finance 840 1B MADHUR VIHAR COLONY CIVIL LINES JHANSI UP 284 001 | JHANSI | JHANSI | UTTAR PRADESH | 284001 | L4 | Rejected-Finance Not become lowest bidder | |
| 5 | Rejected-Technical | - | Rejected-Technical No adverse remark in WLR |
Tender Value
Refer Docs
EMD Value
₹20,000
Closing Date
21 Aug 2021, 6:00 pmClosed
Major Deepak Kumar
Garrison Engineer Jhansi
REPAIR / MAINT TO VARIOUS SIZES OF GEYSERS, SOLAR WATER HEATERS AND CONNECTED WORKS UNDER AGE E/M AT GE JHANSI
2021_MES_462900_1
GE/JHA/TOK/36 OF 2021-22
Open Tender
Civil Works
Item Rate
180 days
GE Jhansi
Please refer tender documents
6 documents required · 6 mandatory
₹500
Yes
GE Jhansi
₹20,000
Yes
9 Oct 2021
26 Jul 2021
24 Aug 2021
26 Jul 2021
21 Aug 2021
7 Aug 2021
Amount
Taking down carefully the electric storage type water heater of capacity up to 50 liters from its installed position by disconnecting all water and electric supply connections for necessary repairs, opening the geyser carefully, identifying and replacing the defective parts, reassembling and reinstalling in its existing location or new location and testing for proper functioning complete all as specified and directed by Engineer-in-Charge. Note: The spare parts required shall be measured and paid separately under relevant items as "Supply Only".
Supply only heating element 1500 Watts / 2000 Watts of any type suitable for existing model of geyser 25L/50L.
Supply only thermostat of any type suitable for existing model of geyser 25L/50L
Supply only apparatus plate of any type suitable for existing model of geyser of capacity 25L/50L.
Supply only safety valve of any type suitable for existing model of geyser of capacity 25 L / 50 L
Supply only indicator lamp Red / Green of any type suitable for existing model of geyser of capacity 25L/50L.
Supply and fix in replacement of flexible PVC connection pipe 450mm long suitable for Hot/Cold water application including taking down existing unserviceable PVC connection pipe of any description complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of 20A rated metal clad plug 2 pin plus earth suitable for metal clad plug & socket board, 230V, AC including taking down existing unserviceable metal clad plug of any description complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of 20A rated metal clad socket 2 pin plus earth suitable for metal clad plug & socket board, 230V, AC including taking down existing unserviceable metal clad socket of any description complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of Modular Socket 25 A, 6 pin 2 module including taking down existing unserviceable socket of any description complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of mini MCB 16A to 25, SP, C curve suitable for modular switch board including taking down existing unserviceable MCB of any description complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of modular white cover plate with frame 3 module including taking down existing unserviceable cover plate with frame of any description complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of modular metal flush box 3 module including cutting the wall surfaces for flush mounting of socket board including taking down existing unserviceable metal box of any description and making good with cement plaster, putty and paint to match with the existing surface all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of Plug top, 3 pin, 16 Amps, single phase, 230 volts, 50 Hz including taking down existing unserviceable plug top of any description complete all as specified and directed.
Supply and fix in replacement of switch piano flush type 16 Amps, one way, 240V, 50Hz including taking down existing unserviceable switch of any description complete all as specified and directed.
Supply and fix in replacement of socket 16A & 6A, 2-in-1 flush type universal 240V, 50Hz including taking down existing unserviceable socket of any description complete all as specified and directed.
Supply and fix in replacement of Switch socket combination 2 in 1, 6 pin, 6 and 16 Amp flush type universal including taking down existing unserviceable switch socket combination of any description complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of MCB 40A, 10 KA, SPN, 'C' curve, 240 V, 50 Hz including taking down existing unserviceable MCB of any description complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of MCB 6 - 32A, 10 KA, single Pole, 'C' curve, 240 V, 50 Hz including taking down existing unserviceable MCB of any description complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of MCB distribution board, SPN, 4 way in sheet steel powder painted enclosure double door type with minimum IP 43 degree of protection with built in copper bus bar, neutral link and earth link complete including cutting the wall surfaces for flush mounting of DB and making good with cement plaster, putty and paint to match with the existing surface including taking down existing unserviceable MCB DB of any description complete all as specified and directed by Engineer-in-Charge. Note: MCBs shall be measured and paid separately.
Supply and fix in replacement of heating element suitable for Solar Water Heater of capacity up to 200 Liters.
Supply and fix in replacement of thermostat suitable for Solar Water Heater of capacity up to 200 Liters.
Supply and fix in replacement of angle cock, cast copper alloy, chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for pipe or for unions of size 15mm bore dia including taking down existing unserviceable angle cock of any description complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of CP Bib taps 15mm, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule including taking down existing unserviceable bib tap of any description complete all as specified and directed by Engineer-in-Charge.
Supply and connect in replacement of PVC insulated and PVC sheathed three core round cable with 1.5 sqmm stranded copper conductor conforming to IS:694 including taking down existing unserviceable copper / aluminium cable of any description complete all as specified and directed by Engineer-in-Charge.
Supply and connect in replacement PVC insulated and PVC sheathed three core round cable with 2.5 sqmm stranded copper conductor conforming to IS:694 including taking down existing unserviceable copper / aluminium cable of any description complete all as specified and directed by Engineer-in-Charge.
M&L for sub main wiring along with earth wire with FRLS insulated copper conductor, single core cable drawn through and including medium grade rigid PVC conduit conforming to IS:9537 (Pt-III) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 25mm concealed in wall/ floor etc including taking down existing unserviceable sub main wiring of any description complete all as specified and directed by Engineer-in-Charge for the following sizes:- (Note: Three runs of copper cable and one run of PVC conduit shall be measured as one unit length)
2runs x 4 sqmm(Ph & N) + 1run x 4 sqmm(earth wire)
2runs x 6 sqmm(Ph & N) + 1run x 6 sqmm(earth wire)
Notes for item No. 27.00 to 27.02: (i) Quoted rate shall deemed to include the cost of cutting chases on wall/floor for concealed conduit wiring and making good with cement plaster, putty and paint to match with the existing surface. (iii) If any beam / column / Rock wall is encountered while cutting chases, that particular portion may be provided with PVC casing & capping or surface conduit for drawing cables and surface PVC gang box fully enclosed type for mounting switches, sockets & regulators etc to avoid any damage to the structure. (iv) No cutting shall be done on ceiling for laying PVC conduit for ceiling fan point wiring. Surface conduit or PVC casing capping may be used in that portion.
M/s Pooja Electricals
M/s Ratan Mechanical Works
M/S Kumar Contractors
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .