Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.6 CrAdmitted-Finance NO 1C C L C WORKS ROAD NEW COLONY CHROMEPET CHENNAI 600044 | CHENGALPATTU | TAMIL NADU | 600044 | ₹1.6 Cr | L1 | Admitted-Finance |
| 2 | L2₹1.8 Cr+₹12.9 L (7.83%)Admitted-Finance 201 PLOT NO 32 SHALAKA BLDG TPS II JUHU ROAD SANTACRUZ WEST MUMBAI SUBURBAN MAHARASHTRA 400054 | MUMBAI SUBURBAN | MAHARASHTRA | 400054 | ₹1.8 Cr+₹12.9 L (7.83%) | L2 | Admitted-Finance |
| 3 | L3₹1.9 Cr+₹22.4 L (13.6%)Admitted-Finance | ₹1.9 Cr+₹22.4 L (13.6%) | L3 | Admitted-Finance |
| 4 | L4₹1.9 Cr+₹25.6 L (15.6%)Admitted-Finance 6 NEW SADGURU NANIK INDUSTRIAL ESTATE OFF WESTERN EXPRESS HIGHWAY GOREGAON E MUMBAI 400063 INDIA | MUMBAI SUBURBAN | MAHARASHTRA | 400063 | ₹1.9 Cr+₹25.6 L (15.6%) | L4 | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹4.2 L
Closing Date
18 May 2020, 6:00 pmClosed
Regional Manager
AAI Cargo Logistic and Allied Services company Limited, Integrated Air Cargo Complex, Meenambakkam, Chennai Airport, Chennai 600 016
M/O OF Electrical and Mechanical Installations, AC, water coolers and sliding gate on air side at Integrated Air Cargo Complex at Chennai Airport, Chennai
2020_AAICL_44187_1
AAICLAS/FMC/ELECTRICAL-16/2020
Open Tender
Electrical Works
Works
730 days
Integrated Air Cargo Complex Meenambakkam Chennai
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,180
AAICLAS
₹4.2 L
1 Jun 2020
6 Mar 2020
22 May 2020
6 Mar 2020
18 May 2020
18 Mar 2020
6 Mar 2020 - 18 Mar 2020
Amount
SH : I :-- FMC of Internal, External E & M Insatllations, All type of Air Conditioners and water coolers.
Facility Management of Internal and External E & M Installations to ensure satisfactory serviceability through providing maintenance service for all Electrical & Mechanical Installations, all split AC window AC cassette AC and Ductable AC and all type of Water coolers monthly at Integrated Cargo complex , (Import & Export Cargo, CUDCT Phase I & II) etc, involving repairs and maintenance, attending to complaints / faults/ breakdown and taking rectification action, ensuring serviceability / satisfactory working condition of the systems, preventive maintenance of records / data entires and documentation including effective supervision etc as per the detailed specifications , special conditions , terms and conditions covered under the tender clauses. Integrated cargo complex on round the clock in 3 shifts (8 Hr./Shift) basis on all days including Sunday and Holidays. as per manpower details given as Annexure "D"
First Year
Second Year
Providing mobile communication facility at One locations with minimum monthly topup of Rs. 300/- for each mobiles etc., as required for the entire contract period.
First Year
Second Year
SH: II :-- ARC for Wiring, Cable Laying and Other Repair Works for Internal & External E & M Installations.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Group C
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Group C
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
4 X 6 sq. mm + 2 X 6 sq. mm earth wire
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
1 or 2 Module (75mmX75mm)
3 Module (100mmX75mm)
4 Module (125mmX75mm)
6 Module (200mmX75mm)
8 Module (125mmX125mm)
12 Module (200mmX150mm)
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
a) 5/6 amps Modular switch
b) 15/16 amps Modular switch
c) 3 Pin 5/6A, Modular type Socket (With shutter)
d) 6 pin15/16A, Modular type Socket( With shutter)
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.
a) 3 modular
b) 4 modular
c) 6 modular
d) 8 modular
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
100 A, 16 KA,TPMCCB
100 A, 30KA, FPMCCB
125 A,36KA,FPMCCB
250 A,50KA,FPMCCB
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
8 way (4 + 24), Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required
Supplying and fixing 20 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supplying and fixing 30 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 A "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Sypply and installing following size of perforated perpainted MS cable trays with perforation nor more than 17.5% in convenient section , joined with commectors, suspended from the ceiling with MS suspenders including bolts & nuts, painting suspenders etc as required.
300mm width x 50 mm depth x 1.6 mm thickness
450mm width x 50 mm depth x 2.0 mm thickness
Providing & Creating of earth pits using CPRI tested and certified advanced chemical earth rod made of copper tube of 3'' dia,3m long, 3mm thickness, installed vertically or horizontally as per the site conditions complete with flanges, bends and top cover dully backfilled with Earth enhancing compound of not less than 50kgs. along with required materials as per the soil conditions to achieve earth resistance less than 3ohms with one no.of heavy duty plastic inspection chamber including excavation & refilling complete etc. as required. Model No. Standard GE83
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required
Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Upto 35 sq. mm
Above 35 sq. mm and upto 95 sq. mm
Above 95 sq. mm and upto 185 sq. mm
Above 185 sq. mm and upto 400 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
Upto 35 sq. mm (clamped with 1mm thick saddle)
Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.
Upto 35 sq. mm (clamped with 1mm thick saddle)
Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
3½ X 25 sq. mm (28mm)
3½ X 35 sq. mm (32mm)
3½ X 50 sq. mm (35mm)
3½ X 70 sq. mm (38mm)
3½ X 95 sq. mm (45mm)
3½ X 120 sq. mm (45mm)
3½ X 150 sq. mm (50mm)
3½ X 185 sq. mm (57mm)
3½ X 225 sq. mm (62mm)
3½ X 240 sq. mm (62mm)
3½ X 300 sq. mm (70mm)
3½ X 400 sq. mm (82mm)
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
3½ X 25 sq. mm
3½ X 35 sq. mm
3½ X 50 sq. mm
3½ X 70 sq. mm
3½ X 95 sq. mm
3½ X 120 sq. mm
3½ X 150 sq. mm
3½ X 240 sq. mm
3½ X 300 sq. mm
3½ X 400 sq. mm
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
200 mm dia (OD-200 mm & ID-175 mm nominal)
Rewinding with super enamelled copper winding wire, varnishing, baking, overhauling, replacement of ball bearings, capacitors, greasing, refitting etc, of following fans as required.
a) 600 mm sweep air circulators
b) 450 mm sweep air circulators
c) 1200 mm sweep celling fan
d) 400mm Sweep wall mounting cabin fan
e) 400mm Sweep pedestal fan
f) 300 mm Exhaust fan
g) 450 mm Exhaust fan
Supply, Installation, Testing and commissioning of High bay light with pressured die- cast aluminium housing and high efficiency glass cover. The system lumen output shall not be less than 10,000 lumen and system wattage shall not be more than 100 watts. The driver efficiency : > 85 % and life L70, 50 k hrs colour temperature should be 6,500K. The luminaire shall have an efficiency > 115 LM / W. The luminaire shall be IP 65. The luminaire should be operated with PF > 0.95 and THD < 10%. The operating voltage should be 140 -270 Volt AC. The luminaire should be with inbuilt surge protection >= 3 kv. The luminaire should be with toughened glass. The luminaire should be with individual LEDS with dedicated peanut lens. The lens should be mechanically fitted (not glue fixed). LED should be protected with toughened glass. The LED should be SMD type (not with COB type LED). The CRI should be > 80. The luminaire should have a life of 50,000 burning hours at L 70. The driver should be Potted type. the luminaire manufacturer should submit LM79 and LM 80 reports from NABL accredited LAB with all associate control gear boxes and lamps equivalent (approved makes) to Philips BY 325 P LED 100 W CW F GWB with mounting arrangement in the existing ceiling / trust connecting wires as required and all complete.
Supply of LED tube in all types of existing fittings testing and commissioning with polycarbonate LED tubes of 16-20 watts
Supply, Installation, testing and commissioning of Recess mounted LED 600x600mm fitting made of CRCA steel, fixture should have minimum efficiency at System level (Not Chip Level) > = 115 lumens / watt, 3600lm, Life of fixture 50000hrs@L70B50 Lumen maintenance, CCT up to 6500, CRI minimum 80, PF >0.9, THD<10%, IK02 and an operating Voltage Range of 140 - 270 V. The fixture diffuser should have high efficiency PS diffuser and the SDCM should be <5. The fixture should comply with the other parameters as per IS10322, IEC60598 and specifications. Minimum system Lumens 3600. Similar (approved Makes) to Philips Models RC380B LED36S -6500 G4 L60 W60 PSU OD >The rates quoted shall be inclusive of accessories for fixing the fitting in the existing opening and connecting wires etc
Supply, installation, testing & commissioning of recessed LED downlight fixture should have minimum efficacy at System level (Not Chip Level) >=95lumens/ watt, 1000lm, system wattage>=10.5W Life of fixture 50000hrs@L70 Lumen maintenance, CCT up to 6500K, CRI minimum 80, PF >0.9, THD<10% and an operating Voltage Range of 220 - 240 V. The fixture diffuser should have high efficiency diffuser and the SDCM should be <5. The fixture should have minimum 2Kv in-built surge protection. The fixture should comply with the other parameters as per IS10322, IEC60598 and specifications. Similar (approved Makes) to Philips Models DN392B LED10S - 6500 PSU WH. The rates quoted shall be inclusive of accessories for fixing the fitting in the existing opening and connecting wires etc..
Supply, Installation, testing & Commissioning of High Bay light with Pressure die-cast aluminium Housing with heat dissipating arrangement. The system lumen output shall not be less than 15000 lumens and system wattage shall not be more than 150W. The Driver Efficiency : > 85% and Life L70, 50k Hrs. Colour temp should be 6500K. The luminaire shall have an efficacy > 100-115 lm /W. The luminaire should be IP 65. The luminaire should be operated with PF > 0.95 and THD < 10%. The operating voltage should be 140-270V AC. The luminaire should be with inbuilt surge protection >=3kV. The luminaire should be with individual LEDs with dedicated peanut lens, the lens should be mechanically fitted (Not glue fixed). The LEDs should be protected by toughened glass. The LEDs should be SMD type (not with COB type LED). The CRI should be >80. The luminaire shall have a life of 50,000 burning hours @ L70. The driver should be potted type. The luminaire manufacture shall submit LM79 and LM80 reports from NABL accredited lab. with all associate control gear boxes and lamps. equivalent (approved makes) to WIPROLH 17-232-060-50-XX-140W. with mounting arrangement in the existing ceiling/ truss, connecting wires etc. as required and all complete.
Supply of 300 mm sweep exhaust fan suitable for operation single phase 230 V supply with all accessories of Crompton make as required
Providing illumination with standard coloured serial lamps 2500 sets per day (containing minimum 20Nos. Of lamps per set)on the city side of Cargo building, car parking area, Lawn & Trees ect., as directed by the Engineer-in-Charge for the each year (illumination on special occasion like Independence day, Deepavali,christmas,Republic day,new year & Pongal) (in line with the festival the special effect lights Happy New year, Happy Diwali shall be provided)
Providing illumination with Multicolour LED colour wash flood lights 100 nos per day with required cables & all accessories to illuminate the facia of Car (illumination on special occasion like Independence day, Deepavali,christmas,Republic day,new year & Pongal)
Supply of 1.1 KV grade of following size of armoured Aluminium conductor PVC/XLPE insulated and PVC sheathed cable as per IS 1551(Part I) 1988/IS-7098 (Part I) 1985 respectively with up to date amendments .
a) 4 x 10 sq.mm
b) 3.5 x 35 sq.mm
c) 3.5 x 50 sq.mm
d) 3.5 x 70 sq.mm
e) 3.5 x 95.sq.mm
f) 3.5 x 300 sq.mm
g) 3.5 x 25 sq.mm
Cleaning the surface/removal of rust and painting with 1 cost of synthetic enamel paint(spray painting of approval shade and make for LT panel board/rising mains/MCB DB's/SFU's/other accessories
Supply of LED STREET LIGHT FITTING 35 WATT he Luminaires with casing/housing (single piece housing)shall be pressure die casted aluminium alloy with higher thermal conductivity,Toughned transparent glass cover with electronic control drive LED lamps all complete of make WIPRO/HAVEELS/PHILIPS or equivalent as approved make
SH-III: CMC of Sliding gate, AC and Water Coolers
CMC of sliding gates including replacement of limit switches, spare Parts in control panel routine and preventive maintenance of all the items covered except rewinding/replacement of motor and structural parts for a period of 1 year.
Rewinding of Sliding gate motor
Providing labour with necessary tools for emergency/unanticipated breakdown /maintenance work unsusceptible for measurements and when required
a) Wireman
b) Helper
Supply of various accessories of split AC of different makas (Carrier, Blue Star, Voltas, Hitachi, etc)
Fan Motor (Indoor)
Fan Motor (Out Indoor) on replacement basis
Fan Blade
Fan Motor Blower
Compressor
Compressor 1.5 TR on replacement basis
Compressor 2.0 TR on replacement basis
Capacitor (50 mfd)
Capacitor (60 mfd)
Capacitor (2.5 mfd)
Capacitor (3 mfd)
Capacitor (4 mfd)
Capacitor (6 mfd)
Supply of following items for split AC installation / replacement of existing damaged items
Drain Hose (1/2)
Three way valve (1/4)
Three way valve (3/8)
Three way valve (1/2)
Three way valve (5/8)
Refrigeration Gas (R 22 A)
Refrigeration Gas (R 32A)
Gas (R 134 A)
A/C Remote (all models)
Supply of various accessories for different type of water cooler (kelby,conway,crossfield)
Adapter (240 / 24 v)
Solenoid Valve
Pump (24 / 36 v)
Float valve switch
Heater switch
Thermostat
Heater Coil (1000w)
Thermostat & Cut off
Membrane (100 gpd)
Membrane (300 gpd)
Spun (10 inch)
Spun (20 inch)
Carbon (10 inch)
Carbon (20 inch)
Supply, Fixing & connection of refrigeration pipe (copper) of size 1/2'' & 1/4''along with 2.5 Sq.mm flexible cable with insulation of copper pipe etc., complete as required (for re-installation purpose)
Copper Pipe with Insulation Hose (1/4)
Copper Pipe with Insulation Hose (3/8)
Copper Pipe with Insulation Hose (1/2)
Copper Pipe with Insulation Hose (5/8)
Copper Pipe with Insulation Hose (3/4)
Supply installation testing and commissioning of MS stand for Split AC OUTDOOR UNITS
Supply of 3 Phase contactor for Cassette AC 32amps
Supply of 5 star rated Split AC 1.5 TR inverter Type Hi -wall mounted with Indoor and Out Door units with minimum 3 mtr Length refrigerant Copper piping, insulation copper electrical cable for inter connection between indoor and outdoor units Suitable for operation at 50 Hz 230 V AC supply complete wih all accessories,chordless remote control unit , Refrigerant filling etc as per approved manufacturer specifications at AAICLAS , integrated air cargo complex, Meenambakkam ( Make :- Voltas/Blue Star /AAI approved makes )
Supply installtion testing and commissioning of 4 KVA automatic Voltage stabiliZer wall mounting type for 1.5 Tr split AC capable of operation on input Voltage range of 160 V to 280 V and output range of 20 to 240 V with on time dealy relay (2 to 4 Minutes) high/low voltage cut off features etc complete as required
Annual Service contract of L & T GE Spectronics make low voltage ACB of capacity of ranging from 800 A to 2500 A by carrying out preventive maintenance (Once in Six months) as per OEM's ( service contract is excluding spare)
Repairs to all type of stabilizer upto 4KVA as per need including replacement of all spares etc., as required in association with the respective manufacturer of single phase stabilizer
SH:IV:-- Supply of Fire Extinguishers and Spares for fire extinguishers.
Supply of CO2 TYPE FIRE EXTINGUISHER SPARES given Below
Supply of 4.5 kg CO2 type Fire Extinguisher
CO2 Horn for 02 kgs & 03 kgs. Fire Extinguisher.
CO2 Horn for 4.5 kgs. Fire Extinguisher.
CO2 P.V.C Horn for 6.8/09 kgs. & 22.5 kgs. Fire/ Ext.
CO2 Handle Type Horn for 4.5 kg.
CO2 M.S. Connecting Pipe for CO2 Hose.
CO2 Connecting PVC Handle.
CO2 Plastic Lock ring.(50 Pieces)
CO2 M.S.Lock Pin. (100 pieces)
CO2 Wall Mounting Bracket.
CO2 6.8 kg 9 kg trolley with wheel complete.
CO2 22.5Kg M.S. Trolley set with Rubber Wheel
CO2 01Meter, Hose with Fitting. (Only Hose).
CO2 02 Meter, Hose with Fitting. (Only Hose).
CO2 03 Meter, Hose with Fitting. (Only Hose).
CO2 05 Meter, Hose with Fitting. (Only Hose).
CO2 Aluminum Wheel (Open Close)
CO2 Brass Valves. (ISI Mark)
Rubber Handle Grip.
Supply of A.B.C. TYPE FIRE EXTINGUISHER SPARES given Below
A. B. C. 05/6kg Kgs. Hose with Fitting.
A. B. C. 10 Kgs. Hose with Fitting.
A. B. C. 500 Gms. Valve.3
A. B. C. 01/02Kgs. Valve.
A. B. C. 04/06/09/10Kgs. Valve.
A. B. C. 05/06/09 Kgs. Belt.
A. B. C. Pressure Guage die from
A. B. C. S. S. Lock Pin For 4/6/9kg . (50 Pieces)
A. B. C. Lock Pin For 02 Kgs. (50 Pieces)
A. B. C. Wall Mounting Bracket for 2/ 4Kgs
A. B. C. Wall Mounting Bracket for 5/ 6kg
A. B. C. Wall Mounting Bracket for 9/10kg A.B.C.
A. B. C. P.V.C Neck Ring. (Black, Yellow, Red)
A. B. C. ‘O’ Ring (50 Pieces)
A. B. C. ‘O’ Ring (100 Pieces)
DElite System Engineering (India) Pvt. Ltd.
CHENNAI ENGINEERING SERVICES
PREMIER ENGINEERING TECHNICS PVT. LTD.
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .