Tender Value
₹4 L
EMD Value
₹80,000
Closing Date
9 Oct 2021, 6:00 pmClosed
CWE LUCKNOW
229 MG ROAD CWE LUCKNOW
REPAIR/REPLACEMENT OF CENTRAL AC PLANTS OF SIGNAL CENTRE AC PLANT 3 X 25 TR TRANSMITTER STATION 3 X 25 TR AND OPS ROOM COMPLEX HQ CC INCL COMPLETE INTERNAL WIRING OF VARIOUS CENTRAL AC PLANTS DUCTING AND GATE LIGHTS ETC IN THE AREA OF AGE E/M
2021_MES_474594_1
CWE/LKO/EM/T-41 OF 2021-2022
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
LUCKNOW
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE EM LUCKNOW
₹80,000
Yes
21 Oct 2021
11 Sept 2021
11 Oct 2021
11 Sept 2021
9 Oct 2021
25 Sept 2021
Amount
M&L for cleaning of all Condenser tubes of central AC plant by disconnecting the condenser from the system, cleaning by descaling pump of suitable capacity of 110 ft head using descaling solution of Make:-MAIC / HIBIRD or Hydrochloric acid 20%, cleaning the system through cooling tower incl water pipe line complete by using descaling solution, cleaning condenser tubes by nylon brushes/ by descaling water pressure pump & mild steel rods of suitable size, renewal of suction water filter for the following AC Plants. (Note:- T&P such as pumps, tube etc & descaling solution etc shall be arranged by the contractor at his own cost.) NOTE- Cleaning of all gate valves, Butterfly valves and gaskit etc by opening and reassembling at the same position for proper functioning of plants is also included in the above said work.
3x25 TR capacity plant (double circuit) Signal Centre Central Command ( Set of Three Compressor of cap. 25 TR(2X12.5 TR) having two condensor tubes ). SM/MES NO- NYA.
3x25 TR capacity plant (double circuit) Transmitter Station( Set of three Compressor of cap. 25 TR(2X12.5 TR) having two condensor tubes )SM/MES NO- 556-W/138/CR-1/16 AND 556-W/138/CR-2/16
3x50 TR capacity plant ( Quadruple circuit) Ops Room Complex HQCC( Set of FOUR Compressor of Cap. 50 TR( 4X12.5 TR) having four condensor tubes )SM/MES No- 833W/136/CO-1,CO-2,CO-3/18
Carrying out pressure leak testing by nitrogen gas of the system of AC plant for leak proof valve joints, seal & other connected controls etc. including identifying & rectifying of leaks, defects (if any) & maintaining constant pressure of 160 LBS PSI on low side & 300 PSI on high side at least for 24 Hrs complete all as specified and directed by EIC. for the following AC plants :- (Note: The arrangement of T&P & nitrogen gas shall be contractors responsibility).
3x25 TR capacity plant (double circuit) Signal Centre Central Command ( Set of Three Compressor of cap. 25 TR(2X12.5 TR) having two condensor tubes ). SM/MES NO- NYA.
3x25 TR capacity plant (double circuit) Transmitter Station( Set of three Compressor of cap. 25 TR(2X12.5 TR) having two condensor tubes )SM/MES NO- 556-W/138/CR-1/16 AND 556-W/138/CR-2/16
3x50 TR capacity plant ( Quadruple circuit) Ops Room Complex HQCC( Set of FOUR Compressor of Cap. 50 TR( 4X12.5 TR) having four condensor tubes )SM/MES No- 833W/136/CO-1,CO-2,CO-3/18
Cleaning of AHU cooling coil (after dismantling front portion of AHU) by applying high air pressure followed by descaling solution & then washing with water pressure using jet pump and reassembling there after complete all as specified and directed by EIC including servicing of AC ducts ,cleaning etc and setting of grills, louvers and position of proportioning dampers & also minor repair to duct insulation for missing section complete for the following central AC plant :-
3x25 TR capacity plant (double circuit) Signal Centre Central Command having AHU Capacity 24000 cfm Model-ETU-2304
3x25 TR capacity plant (double circuit) Transmitter Station having AHU Capacity 18000 cfm.
3x50 TR capacity plant (Quadruple circuit) Ops Room Complex HQCC having 4 AHUs of capacity-15000 cfm
3x50 TR capacity plant (Quadruple circuit) Ops Room Complex HQCC having 4 AHUs of capacity-16000 cfm
3x50 TR capacity plant (Quadruple circuit) Ops Room Complex HQCC having 4 AHUs of capacity-17000 cfm
3x50 TR capacity plant (Quadruple circuit) Ops Room Complex HQCC having 4 AHUs of capacity-19000 cfm
Taking out residual refrigerant gas from AC plant into empty cylinder of the following capacity AC plants and depositing the same in AGE yard for further reuse . Note :- (i) Empty cylinders will be issued temporarily by the department (ii) All accessories and T&P required for transfer of gas into the cylinder will be arranged by the contractor at his own cost.
3x25 TR capacity plant (double circuit) Signal Centre Central Command ( Set of Three Compressor of cap. 25 TR(2X12.5 TR) having two condensor tubes ). SM/MES NO- NYA.
3x25 TR capacity plant (double circuit) Transmitter Station( Set of three Compressor of cap. 25 TR(2X12.5 TR) having two condensor tubes )SM/MES NO- 556-W/138/CR-1/16 AND 556-W/138/CR-2/16
3x50 TR capacity plant ( Quadruple circuit) Ops Room Complex HQCC( Set of FOUR Compressor of Cap. 50 TR( 4X12.5 TR) having four condensor tubes )SM/MES No- 833W/136/CO-1,CO-2,CO-3/18
Taking out nitrogen gas (residual) after flushing, pressure testing & vaccumising the whole AC Plant with the help of vaccum pump & leaving the plant for 24 hrs for checking the leak point and commissioning the plant by charging refrigerant gas complete all as directed for the following plants (Note:-1) Arrangement of vaccum pump shall be the contractors responsibility. (2) Refrigerant gas for charging shall be measured and paid seperately under respective item as supply only.
3x25 TR capacity plant (double circuit) Signal Centre Central Command ( Set of Three Compressor of cap. 25 TR(2X12.5 TR) having two condensor tubes ). SM/MES NO- NYA.
3x25 TR capacity plant (double circuit) Transmitter Station( Set of three Compressor of cap. 25 TR(2X12.5 TR) having two condensor tubes )SM/MES NO- 556-W/138/CR-1/16 AND 556-W/138/CR-2/16
3x50 TR capacity plant ( Quadruple circuit) Ops Room Complex HQCC( Set of FOUR Compressor of Cap. 50 TR( 4X12.5 TR) having four condensor tubes )SM/MES No- 833W/136/CO-1,CO-2,CO-3/18
Attending the complaints of Ac Plants by Electrician/Technician/Mechanic for non functioning of part of compressor,blower motor,compressor pump,chiller pump,CT fan,electric pannel and all part of AC plant at any location,rectified the same all as specified and directed by EIC.Note-(1) Complains should be attended immediately within one hour and to be rectified the same day at the earliest without affecting the services.(2) Complains should be attended 24 Hrs through phone.(3) complains should be detailed/attended by specified electrician/technician/mechanic having knowledge of AC plants and equipped with multimeter,tester and concerned tool etc.
Fixing only Power contactor 3 TF 30 with NO & NC contact, of coil Volatge 220 V all as specified and directed. (Make:- L&T / Seimens). Note- The items will be provided under Sch 'B' store
Fixing only Power contactor 3 TF 32 with NO & NC contact , of coil Volatge 220 V all as specified and directed. (Make:- L&T / Seimens) Note- The items will be provided under Sch 'B' store
Fixing only Power contactor 3 TF 47 with NO & NC contact , of coil Volatge 220 V all as specified and directed. (Make:- L&T / Seimens) Note- The items will be provided under Sch 'B' store
Taking down the existing defective discharge gauge and supply & fixing new oil pressure gauge, 100 mm dia, [(-) 30 to 0 & 0 - 300 PSI] complete all as specified and directed. (Make:- Fiebig/ Guru)
Taking out the existing unserviceable high & low pressure cut - out switch and supply & fixing new high & low pressure cut-out switch type. MP - 15 all as specified and directed. (Make:- INDFOSS / RANUTROL)
Taking out the existing unserviceable low pressure cut - out switch and supply & fixing new low pressure cut-out switch type. MP - 1 all as specified and directed. (Make:- INDFOSS / RANUTROL)
Taking out the existing unserviceable low pressure cut - out switch and supply & fixing new low pressure cut-out switch type. MP - 5 all as specified and directed. (Make:- INDFOSS / RANUTROL)
Taking out the existing defective pilot control solenoid valve and supply & fixing new pilot control solenoid valve all as specified and directed (Make: SPORLAIN or as approved by G.E.)
Taking out the existing defective loader / unloader solenoid valve ( Capacity Control solenoid valve) and supply & fixing new loader / unloader solenoid valve all as specified and directed (Make: Nikko / Rotex or equivalent as approved by GE)
S&F ( in repairs) single phase preventer to prevent against single phasing, reverse phasing with wiring & testing complete all as specified and directed (Make:- Minilec / Electromed / L&T)
Supply and filling refrigerant gas Non CFC compatible to R-22/R-407 in returnable sealed cylinder to various Central AC Plants all as specified and directed. (Make:- Floran / Mafron)
Taking out the existing silica gel filter drier 5/8"x 5/8" dia flare type and supply & fixing new filter drier of the same type & size (Make:- Universal / Unistar) including repairs to flare etc at all as specified and directed by EIC
Taking out the existing silica gel filter drier 1/2" X 1/2" dia flare type and supply & fixing new filter drier of the same type & size (Make:- Universal / Unistar) including repairs to flare etc at all as specified and directed by EIC
Supply and replacement of return air grill aluminium with powder coated white collers of size 300 mm x 900 mm complete all as specified and directed.
Supply and replacement of air grill MS air control damper of size 300 mm x 900 mm or as per site complete all as specified and directed.
Supply, fabrication and fixing in replacement pre filter to precipitate 5 - 10 micron air particle suitable for AHU of central type AC plant made out of extended metal frame of 20 SWG GI sheets of size 1000mm x 1000 mm and 50 mm thick complete including finish with two coats of aluminium paint after necessary preparation complete all as specified and directed.
Supply and replacement of double convas connection in AHU outlet supply air with GI grame of size 1200mm x 1200mm including tightening with GI nuts, bolts and washers complete all as specified and directed.
Supply & fixing in replacement of water temperature censor for compressor of Make:-Blue Star, any model and Capacity as directed by eng-in-charge.
M&L for renewal of defective water pressure gauge, 0-50 PSI (Make: Fiebig/Guru or as approved by G.E.)
M&L for renewal of defective U Siphon with cock suitable for fixing in condenser and chiller pipe line.
Fixing only in repairs Contactor ML-25, 4 pole, 415 Volts ,25 Amps rating including necessary electrical connection all as specified of L&T or equivalent of other specified make. Note- The items will be provided under Sch 'B' store
Supply only fresh compressor oil (suitable for respective models & makes of compressors) into the plant at different locations in Lucknow Cantt with in a distance of not exceeding 6 Km complete all as specified and directed. Make:- Blue-Star/Servo Friz NH-68 or other equilent make as approved
S&F push button aquiator of existing size with elements all as specified and directed. (Make:- L&T / Vashnow)
S&F timer 7 PU upto 60 seconds all as specified and directed. (Make:- Siemens/L&T / BCH)
S&F thermal overload relay range 10 - 14 amps all as specified and directed. (Make:-ABB / L&T)
S&F thermal overload relay range 14-29 amps all as specified and directed. (Make:-ABB / L&T)
Renewal of PLA relay 8 pin 220 V all as specified and directed
S&F connection plate of fibre glass with 6 way brass, heavy terminal with tripple brass nut & washer suitable for 5/7.5/10/15/20 HP motor complete all as specified and directed.
Dismantling and taking out faulty analog type Ammeter from LT panel and supply and fixing three phase Ammeter digital type upto 0 to 400 Amps with suitable CT's ratio of size 96 mm x 96 mm of any range as required at site including necessary control wire connection and testing complete all as specified and directed by EIC (Make:- Conzerv / L&T / NIPPAN)
Dismantling and taking out faulty analog type Voltmeter from LT panel and supply and fixing three phase Voltmeter digital type upto 0 to 500 Volts with suitable CT's ratio of size 96 mm x 96 mm of any range as required at site including necessary control wire connection and testing complete all as specified and directed by EIC (Make:- Conzerv / L&T / NIPPAN)
Taking out defective Industrial thermometer from water line etc. including disconnecting connection and supply and fixing new thermometer complete with sensor all as specified and directed (Make:- Suraj/Dimle/Guru as approved by G.E.)
Taking out defective Room temperature meter from AHU etc. including disconnecting connection and supply and fixing new temperature meter digital type complete with sensor all as specified and directed (Make:- Suraj/Dimle as approved by G.E.)
Dismantling unserviceable CT fan motor of capacity 3 HP from AC plant and taking out after disconnecting all electrical connection, foundation nuts & bolts and transporting to contractor workshop for carrying out the following repair. (a) Opening of CT fan motor 3 HP capacity cutting the wornout winding, stripping out and cleaning the slots etc. (b) Rewinding the CT motor 3 HP capacity with super enameled copper wire of suitable gauge to match the existing copper wire of standard make conforming to IS specification including taping, varnishing, insulating and re-assembling the motor complete. (c) Transporting back to site after complete repairs and reinstallation at existing location and electric connection and testing on full load for satisfactory performance all as directed.
Dismantling the existing monoblock pump set capacity 3 HP from its foundation including disconnecting all the electrical and water connection etc transporting the same to contractor workshop from plant carry out the following repairs. (a) Opening of pump & motor and cutting the wornout winding and cleaning the slots with petrol & brush and re-winding the motor with super enameled copper wire of suitable gauge to match the existing size of stranded make confirming to IS specification including taping , varnishing, insulation and re- assembling the motor complete. (b) Re-assembling the pump and motor and reinstallation the same in existing location including connecting all electric and water connections and transportation from contractor workshop to site. Testing complete for satisfactory performance all as specified and directed.
Dismantling the existing Chiller water/Condenser water pump set capacity 5 HP from its foundation including disconnecting all the electrical and water connection etc transporting the same to contractor workshop from plant carry out the following repairs. (a) Opening of pump & motor and cutting the wornout winding and cleaning the slots with petrol & brush and re-winding the motor with super enameled copper wire of suitable gauge to match the existing size of stranded make confirming to IS specification including taping , varnishing, insulation and re- assembling the motor complete. (b) Re-assembling the pump and motor and reinstallation the same in existing location including connecting all electric and water connections and transportation from contractor workshop to site. Testing complete for satisfactory performance all as specified and directed.
Dismantling the existing Chiller water/Condenser water pump set capacity 7.5 HP from its foundation including disconnecting all the electrical and water connection etc transporting the same to contractor workshop from plant carry out the following repairs. (a) Opening of pump & motor and cutting the wornout winding and cleaning the slots with petrol & brush and re-winding the motor with super enameled copper wire of suitable gauge to match the existing size of stranded make confirming to IS specification including taping , varnishing, insulation and re- assembling the motor complete. (b) Re-assembling the pump and motor and reinstallation the same in existing location including connecting all electric and water connections and transportation from contractor workshop to site. Testing complete for satisfactory performance all as specified and directed.
Dismantling the existing Condenser water pump set capacity 10 HP from its foundation including disconnecting all the electrical and water connection etc transporting the same to contractor workshop from plant carry out the following repairs. (a) Opening of pump & motor and cutting the wornout winding and cleaning the slots with petrol & brush and re-winding the motor with super enameled copper wire of suitable gauge to match the existing size of stranded make confirming to IS specification including taping , varnishing, insulation and re- assembling the motor complete. (b) Re-assembling the pump and motor and reinstallation the same in existing location including connecting all electric and water connections and transportation from contractor workshop to site. Testing complete for satisfactory performance all as specified and directed.
Dismantling the existing Chiller water pump set capacity 15 HP from its foundation including disconnecting all the electrical and water connection etc transporting the same to contractor workshop from plant carry out the following repairs. (a) Opening of pump & motor and cutting the wornout winding and cleaning the slots with petrol & brush and re-winding the motor with super enameled copper wire of suitable gauge to match the existing size of stranded make confirming to IS specification including taping , varnishing, insulation and re- assembling the motor complete. (b) Re-assembling the pump and motor and reinstallation the same in existing location including connecting all electric and water connections and transportation from contractor workshop to site. Testing complete for satisfactory performance all as specified and directed.
Renewal of ball bearing suitable for 3HP capacity motor size - (Make:- NBC / SKF)
Renewal of ball bearing suitable for 5HP capacity motor size - (Make:- NBC / SKF)
Renewal of ball bearing suitable for 7.5HP capacity motor size - (Make:- NBC / SKF)
Renewal of ball bearing suitable for 10HP capacity motor size - (Make:- NBC / SKF)
Renewal of ball bearing suitable for 15 HP capacity motor size - (Make:- NBC / SKF)
Renewal of cover housing -including repair to main shaft and renewal of gun metal bushing as per site all as specified and directed by eng-in-charge.
Renewal of CI impellor and gland plate,gland bush as per site all as specified and directed by eng-in-charge.
M&L for spray painting to central AC Plants of 3 x25 TR capacity at Transmitter Station comprising of compressor, Motor frame & foundation, condenser all connected pipe lines in stranded colour code AHU unit, panels boards & cooling tower etc with two coat of synthetic enamel paint of approved make and shade including lettering and numbering after carrying out necessary preparation of surface by emery paper all as specified and directed.
M&L for spray painting to central AC Plants of 3 x25 TR capacity at SIGNAL CENTER CENTRAL COMMAND AC PLANT comprising of compressor, Motor frame & foundation, condenser all connected pipe lines in stranded colour code AHU unit, panels boards & cooling tower etc with two coat of synthetic enamel paint of approved make and shade including lettering and numbering after carrying out necessary preparation of surface by emery paper all as specified and directed by EIC.
S&F in renewal MCCB-63 Amp, having breaking capacity 10 KA 4 pole AC complete all as specified and directed.
S&F in renewal MCCB-100 Amp, having breaking capacity 10 KA 4 pole AC complete all as specified and directed.
S&F in renewal MCCB-160 Amp, having breaking capacity 25 KA 4 pole AC complete all as specified and directed.
S&F in renewal MCCB-200 Amp, having breaking capacity 25 KA 4 pole AC complete all as specified and directed.
S&F in renewal MCCB-250 Amp, having breaking capacity 25 KA 4 pole AC complete all as specified and directed.
S&F in renewal MCCB-400 Amp, having breaking capacity 36 KA 4 pole AC complete all as specified and directed.
Supply and fixing in renewal Indicating lamp complete LED type all as specified and directed.
Fixing only CI wafer type butterfly valve, PN1.6, hand lever operated with SS shaft / Disc PTFE gland packing CCS stud and bolts Nitrile Sleeves and locking arrangement complete of following sizes/dia all as specified and directed. Note- The items will be provided under Sch 'B' store.
65 mm dia
80 mm dia
100 mm dia
150 mm dia
Supplying and fixing in replacement, connecting and testing onload change over switch 4 pole, 415 volts, AC, SS enclosure including necessary electrical connection of following capacities complete all as specified and directed.
Capacity 200 Amps, 4 Pole, 415Volts
Capacity 400 Amps, 4 Pole, 415Volts
Supply and fixing in replacement CT fan motor with aluminium alloy fan blade - 04 Nos with hub suitable for existing capacity and for 60 TR cooling tower complete all as specified and directed.
Supply and fixing in replacement water flow switch for Condenser/Chiller pipeline with contol wiring all as specified and directed.
Supply & fixing in repairs PCB with Micro computer Control LCD display suitable for 75 TR/150 TR Central Ac Plant(having 3 units of 25 TR and each unit having two compressor of 12.5 TR Apprx) complete all as specified and directed.
Supply & fixing in repairs PCB with Micro computer Control LCD display suitable for 150 TR Central Ac Plant(having 3 units of 50 TR and each unit having four compressor of 12.5 TR Apprx) complete all as specified and directed.
Supply & fixing in replacement PVC fins of honeycomb design double fold 12 layer, size (600x300x150)mm, suitable for cooling tower of central AC plants all as specified & directed.
Dismantling of complete AHU unit of any TR cooling unit and taking out defective/unserviceable blower motor 5 HP with defective ball bearing no P 207/208/210 and shaft & supply & fixing new blower(supply and return blower) new ball bearing of same make and size in repaired blower shaft welding,grinding,polishing and reinstalling the shaft assembly and testing all as specified and directed.
S&F in renewal incl cutting and welding of condensor safety valve of ½'' size the following size to with stand the pressure upto 300 PSI (Make:- PIM / BAP) :-
All as per item No 69 above but 3/8" size
Dismantling defective GM gate valve 20 mm dia at drain pipe of cooling tower of AC Plant supply & fixing new GM gate valve (Make:- NMC / Jalota/kartaar) 15 mm dia with GI Nipple, bends etc nuts & bolts and necessary electric welding all as specified and directed.
All as item No 71 but 40mm dia
All as item No 71 but 80mm dia
Supply and fixing in repair Expansion Valve for chiller unit of central AC plant of Cap 75 TR Central AC Plant (having 3 units of 25 TR and each unit having two compressor of 12.5 TR Apprx) as directed and specified by engineer in charge.Make-Danfoss/Emerson
Supply and fixing in repair NRV Valve of following sizes for chiller unit of central AC plantc ISI marked complete all as specified and directed. Make-Kartaar/Jalota
50 mm dia
80mm dia
100 mm dia
150 mm dia
S&F in repair incl cutting and welding Strainer of ductile Iron body flanged ends with stainless steel strainer,existing rustling pipe cutting with nut bolt etc complete all as specified & directed for following sizes:-Make-Kartar/ kirloskar/ L & T
40 mm dia
80 mm dia
100 mm dia
S&f V-belt for AHU motor of central AC plants all as directed and required at site.
M&L for earthing with galvanized steel earth plate electrode 600mm x 600mm x 6mm buried directly in ground (earth pit not less than2.25 meter deep below ground level) vertically, with top edge of the plate not less than 1.5 meter below normal ground level, connected to galvanized iron wire 32x6mm dia by means of nuts, bolts, washer of GI steel all as shown on electrical plate No 3 of MES Schedule Part 1 connected to earthing test point and testing on completion with and including necessary excavation and earth work, earth electrode, earthing lead from electrode to equipment/substation, adequate quantity of charcoal dust and common salt, test point, PCC (1:3:6) type C-1 (using 20mm graded black trap/granite/Basalt stone aggregate) for earh pit with 40 x 40 x 6 mm mild steel angle CI frame for cover, GI light grade watering pipe 20mm dia with CI funnel and wire mesh, and 40mm dia GI light grade earh lead protection pipe, complete all as specified and directed.
Note for item No 78 above: (i) Main earthing lead from earth plate electrode to test point upto length of 7.50 mtr shall deem to be included in the unit rate quoted by the tenderer against this item. (ii) GI protection pipe and earthing strip beyond 7.50 mtr long shall be measured and paid seperately. (iii) Test result should be less than 1 Ohms or satisfaction of user. If result not found less than 1 ohm the contractor do the earthing as deserve result at own cost. (iv) Quantity of coal 60 kg and quantity of salt should be 100 kg of each earthing.
S&F Galvanised iron strip 32x6 mm thick all as specified and directed.
S&F Ball brass valve of size 25mm dia including cutting and welding complete all as specified and directed.
Same as item No 80 above but 50 mm dia.
S&F Aluminium Cable lugs incl cable tai of following sizes as per requirment of site all as specified and directed.
Servicing and overhauling of walk in cooler of any make and size make Blue star with steel product and with two condensing unit installed at any location in cantonment including cleaning and reparing/ renewal/replacement of defective parts and component complete all as specified and directed. Parts renewed shall be measured and paid separately under appropriate items
Taking out unservieable blower motor of capacity 1/5 to 1/8 HP from walk in cooler and rewinding it with super enamelled copper wire of suitable size, testing and reassebling in position complete all as specified and directed.
Supply and fixing in replacement of LED security light fittings 45 watt, 5700k with IP66 protection comprises of a pressure die cast aluminium housing,heat resistance,toughened glass, LED lenses,surge protector,electronic driver, etc and all accessories pre wired including connecting up with PVC insulated copper conductor cable 1.5sqmm 3 core as required for connections anf 32 mm bore light grade GI Tube mounting bracket of 1.5 m in length bend to shape at 140 degree in L shape and fixed to wall by means of 02 nos of 40x5 mm flat iron clamps, nuts, bolts and washers etc complete all as specified and as directed.
S&F O-RING set for compressor of central AC plant of Make-BlueStar of capacity 12.5 TR (each compressor) all as required at site and specified and directed.
M&L for duct insulation of size 25mm with resin bonded fibre glass wool role of density 24kg/Cum,with factory laminated aluminium vapour barrier,thickness of insulation as specified and icluding the following.(a)M&L for cleaning the duct surface (to be insulated) by scrapping carefully with wire brush etc to make the surface completly free of millscale,dirt,dust,grease and other foreign materials,taking special care so that all duct joints are sealed against any leakage.(b) M&L for applying rubber based adhesive CRPX Compound.(c) M&L forsealing of all longitudinal joints and circular overlaps with and including aluminium foil tape 50mm wide, to make the insulation leakproof.(d) M&L for securing the insulation with and including mechanically fastened nylon/steel strapes of size 12 mm/50mm at maximum intervals of 1.2 mtr all as specified and directed by eng-in-charge..
All as item No 87 above but of size 40mm
Supply,assembly and erection of GI sheet with C&SS rectangular/square duct made out of 'L' shaped hollow profile,duly factory boxed,incl all acessories such as corner, cleat ,carriage bolt,gasket and appropriate sealent on longitudinal joints etc complete of size 20 gauge all as specified and directed by eng-in-charge.
Same as above No 89 above but of size 18 gauge
M&L for insulation of MS pipe with PUF slab 40mm thick with and incl. applying bitiminuous compound and aluminium foil 50mm wide to make the insulation leak proof complete of size 100 mm bore of pipe all as specified and directed.
S&F in repairs Temperature meter digital type for walk-in- coolers of capacity 8 TR Make- BlueStar all as specified and as directed.
S&F in renewal MCCB-500 Amp,adjustable O/L & fixed , thermal magnetic protection unit, S/C fittings having breaking capacity 50 kA 4 pole AC complete all as specified and directed.
M&L for spray painting to central AC Plants of 3 x50 TR capacity at OPs Room Complex HQ CENTRAL COMMAND AC PLANT comprising of compressor, Motor frame & foundation, condenser all connected pipe lines in stranded colour code AHU unit, panels boards & cooling tower etc with two coat of synthetic enamel paint of approved make and shade including lettering and numbering after carrying out necessary preparation of surface by emery paper all as specified and directed.
Supply and fixing in replacement CT fan motor with aluminium alloy fan blade - 04 Nos with hub suitable for existing capacity/150 TR Central AC plant having motor fan of 7.5 HP and rpm-710 complete all as specified and directed.
M/s Acme Engineers and Contractors
Avinash Enterprises
Sanjai sales and services
Ms Kamal Kant Agarwal
Ajanta Motor Store
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .