| 1 | L1₹50.0 LAccepted-AOC SCHEME NO 07 BLOCK NO 22 FLAT NO 03 NEW GURDASPUR DISTT GURDASPUR PB 143521 | GURDASPUR | PUNJAB | 143521 | L1 | Accepted-AOC being L1 | |
| 2 | L2₹56.8 L+₹6.8 L (13.6%)Rejected-Finance | L2 | Rejected-Finance Being other than L1 |
| Sl No | Description | Qty | Unit | Chander Mohan Arora Contractor L2 | HARPAL ENGINEERS AND BUILDERS L1 |
|---|---|---|---|---|---|
| 1.00 | S & F in repairs, installation, commissioning and 1Phase Street Light Timer Switch shall be ASTA CPRI OEM made out of Polycarbonate with glass fiber reinforced and size should be not less than 225 x 295 x 122 mm . The Polycarbonate shall be environment friendly, recyclable, halogen & silicon free, anti acid & anti corrosive. The Junction Box shall be rated for Degree of ingress Protection IP 66/67/69 in accordance with IEC 60529.Weatherproof UV-resistant, rainwater-proof, temperature-resistant. The gasket material of JB shall be Polyurethane and the gasket shall be internally embedded. The Street Light Timer Switch Box shall be complies with requirements of the standards IEC 60998 - 1, IEC 60670 - 22 & IEC 60670 - 2 - 5. The JB Colour according to RAL 9011. The manufacturer of Street Light Timer Switch Enclosure shall submit a copy of IEC Certificate . For better safety the Polycarbonate enclosure and shall be fire retardant & self - extinguishing in accordance with IEC 60695 - 2 - 11, DIN VDE 0304 Part - 3, UL Subject 94 for Flammability V-2. It should be tested at Glow Wire test for 960 degree Centigrade & Current Carrying Capacity upto 102Amps. The impact strength of Polycarbonate enclosure / boards i.e. the Degree of protection against mechanical load shall be in accordance with EN 50298 - 98 for IK 08 including Two Nos. 4 pole connector (Incomer & Outgoing )and one no. MCB DP 'C' curved 25 A with Digital Street Light Timer, Suitable Contractor as per MCB, Also Privided Cable Glands for all cables and chromium plated clamps and nut bolts complete all as per manufacturer’s instructions.
Make : Cat Part :- Hensel/Siemens/GE Power/Rittal. Manufacturer should submit routine test certificate of CJB/PJB | 1 | Each | 12,000 ₹12,000 | 3,000 ₹3,000 Lowest |
| 2.00 | S & F in repairs, installation, commissioning and testing Supply of LT Cable junction box outdoor shall be made out of Polycarbonate with glass fiber reinforced and size should be not less than 155 x 210 x 92 mm(upto Cable Size 16sq.mm). The Polycarbonate Junction Box shall be environment friendly, recyclable, halogen & silicon free, anti acid & anti corrosive. The Junction Box shall be rated for Degree of ingress Protection IP 66/67/69 in accordance with IEC 60529.Weatherproof, UV-resistant, rainwater-proof, temperature-resistant. The gasket material of junction box shall be Polyurethane and the gasket shall be internally embedded. The Junction Box shall be complies with requirements of the standards IEC 60998 - 1, IEC 60670 - 22 & IEC 60670 - 2 - 5. The Junction Box with Suitable Connectors or Terminal Trip. The manufacturer of Junction Box / Enclosure shall submit a copy of IEC Certificate.The JB Colour according to RAL 9011. The Junction Box supply as per approved make List in MES Junction Box category. For better safety the Polycarbonate enclosure and shall be fire retardant & self - extinguishing in accordance with IEC 60695 - 2 - 11, DIN VDE 0304 Part - 3, UL Subject 94 for Flammability V-2. It should be tested at Glow Wire test for 960 degree Centigrade & Current Carrying Capacity upto 102Amps. Junction Box with One No MCB 6Amp SP 10KA C-Curve for Manual operate to LED Light . The impact strength of Polycarbonate enclosure / boards i.e. the Degree of protection against mechanical load shall be in accordance with EN 50298 - 98 for IK 08 including Four Pole. connector for Cable Loop, 3 Nos PVC IP68 Suitable Glands as per Cable and Junction Box with Pole mounting clamps and nut bolts complete all as per manufacturer’s instructions.
Note: Manufacturer should submit routine test certificate of CJB/PJB as per above. | 8 | Each | 25,000 ₹2,00,000 | 2,500 ₹20,000 Lowest |
| 3.00 | Supply & fixing LED street light 90 W 230 volts with surge protection not less than 4 KV inbuilt in driver & minimum 10 KV separate in the light housing. Powder coated pressure die cast aluminium housing , IP-65/66 protection, high power LED street light with the heat resistant thoughened glass lens and making electrical connections pvc insulated sheathed 3 core 1.5 sqmm copper conductor from street light to junction box complete all as specified and directed.
Notes: Driver shall be potted antivibration type. LM-79 and LM-80 for 50000 burning hours. CRI(colour Rendring Index) of fixture shall be ≥ 70. CCT (colour correlated Temp) of fixture shall be 5700K±300K. System Lumen Efficiency shall be>100 Lm/W. 10 KV separate Surge protection shall be provided as a part of fitting. PCB used shall be MC PCB type. The fitting shall have arrangement so that maintenance required, if any can be carried out from Top cover. | 8 | Each | 5,500 ₹44,000 | 2,500 ₹20,000 Lowest |
| 4.00 | Supply and installation of dip galvanised octagonal poles 9 m long top dia (A/F) 70 mm bottom dia (A/F) -minimum 130 mm having thickness 3 mm base plate 200 mm x 200 m x 16 mm(LxBxT) including bolt size 4 x 20 mm (Nox dia) , 200 mm pitch circle dia 600 mm bolt length , 100 mm projected bolt length having door opening of sizes 90 x 500 mm above GL and having hot dip galvanized singlr arm plane arm bracket 1000 mm long for pole having top 70 mm A/F for mounting street light fitting fixed on top with nut bolts washers including provision of cable connector for three phases supply and one No MCB SP of 0.5 A to 6A complete alongwith necessary iron work complete all as per manufacturer’s instructions.
NOTE :- Excavation, earth work, necessary iron work, PCC and RCC work is included in quoted rate. | 8 | Each | 28,000 ₹2,24,000 | 20,000 ₹1,60,000 Lowest |
| 5.00 | Supply and Laying in trenches or passing through pipe or fixing to pole/wall UG cable XLPE, of cross section area 25 sqmm 4 core, PVC insulated, armoured heavy duty electric cable with aluminum conductor, 1100 Volts grade complete all as specified and directed.
Note : Earth work/ sand cushioning shall be measured and paid separately. | 280 | RM | 350 ₹98,000 | 225 ₹63,000 Lowest |
| 6.00 | Supply and Laying in trenches or passing through pipe or fixing to pole/wall UG cable XLPE, of cross section area 10 sqmm 4 core, PVC insulated,armoured heavy duty electric cable with aluminum conductor, 1100 Volts grade complete all as specified and directed. Note: Earth work/ sand cushioning shall be measured and paid separately . | 280 | RM | 250 ₹70,000 | 170 ₹47,600 Lowest |
| 7.00 | Excavation in trenches in soft/loose soil n.exc. 1.5mtr wide and n. exc. 1.5mtr in depth and getting out for laying of cables complete all as specified and directed. | 417 | Cum | 150 ₹62,550 | 100 ₹41,700 Lowest |
| 8.00 | Removing excavated material n. exc. 50m and depositing where directed at a level n. exc. 1.5 m above the starting point complete all as specified and directed. | 67 | Cum | 100 ₹6,700 | 30 ₹2,010 Lowest |
| 9.00 | Returning, filling in, and including spreading, levelling,watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed. | 345 | Cum | 90 ₹31,050 | 30 ₹10,350 Lowest |
| 10.00 | Supply, laying & fixing in double wall corrugated (DWC) pipes made of high density polythyline (HDPE) with all accessories i.e. all type of joints, Sockets, Elbows, bends and End caps of size 75 mm outer dia and 61 mm inner dia etc complete all as specified and directed. | 250 | RM | 80 ₹20,000 Lowest | 80 ₹20,000 Lowest |
Tender Value
₹49.1 L
EMD Value
₹98,280
Closing Date
20 Jun 2026, 6:00 pmClosed
GE NAMS
GE NAMS
SPL REPAIR/ REPLACEMENT OF CEILING FANS AND PROVN OF GEYSERS, WATER COOLER, DESERT COOLER, AC, SECURITY LIGHT, WALL FAN AND OTHER SANCTIONED WORKS UNDER AGE E/M AT NAMS (4th Call)
2026_MES_754470_4
GE NAMS-97/2025-26
Open Tender
Civil Works
Item Rate
180 days
GE NAMS
CLASS D CATEGORY b (i)
8 documents required · 8 mandatory
₹500
GE NAMS
₹98,280
31 Jul 2026
6 Jun 2026
23 Jun 2026
6 Jun 2026
20 Jun 2026
13 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | S & F in repairs, installation, commissioning and 1Phase Street Light Timer Switch shall be ASTA CPRI OEM made out of Polycarbonate with glass fiber reinforced and size should be not less than 225 x 295 x 122 mm . The Polycarbonate shall be environment friendly, recyclable, halogen & silicon free, anti acid & anti corrosive. The Junction Box shall be rated for Degree of ingress Protection IP 66/67/69 in accordance with IEC 60529.Weatherproof UV-resistant, rainwater-proof, temperature-resistant. The gasket material of JB shall be Polyurethane and the gasket shall be internally embedded. The Street Light Timer Switch Box shall be complies with requirements of the standards IEC 60998 - 1, IEC 60670 - 22 & IEC 60670 - 2 - 5. The JB Colour according to RAL 9011. The manufacturer of Street Light Timer Switch Enclosure shall submit a copy of IEC Certificate . For better safety the Polycarbonate enclosure and shall be fire retardant & self - extinguishing in accordance with IEC 60695 - 2 - 11, DIN VDE 0304 Part - 3, UL Subject 94 for Flammability V-2. It should be tested at Glow Wire test for 960 degree Centigrade & Current Carrying Capacity upto 102Amps. The impact strength of Polycarbonate enclosure / boards i.e. the Degree of protection against mechanical load shall be in accordance with EN 50298 - 98 for IK 08 including Two Nos. 4 pole connector (Incomer & Outgoing )and one no. MCB DP 'C' curved 25 A with Digital Street Light Timer, Suitable Contractor as per MCB, Also Privided Cable Glands for all cables and chromium plated clamps and nut bolts complete all as per manufacturer’s instructions.
Make : Cat Part :- Hensel/Siemens/GE Power/Rittal. Manufacturer should submit routine test certificate of CJB/PJB | 1 | Each | - | - |
| 2 | S & F in repairs, installation, commissioning and testing Supply of LT Cable junction box outdoor shall be made out of Polycarbonate with glass fiber reinforced and size should be not less than 155 x 210 x 92 mm(upto Cable Size 16sq.mm). The Polycarbonate Junction Box shall be environment friendly, recyclable, halogen & silicon free, anti acid & anti corrosive. The Junction Box shall be rated for Degree of ingress Protection IP 66/67/69 in accordance with IEC 60529.Weatherproof, UV-resistant, rainwater-proof, temperature-resistant. The gasket material of junction box shall be Polyurethane and the gasket shall be internally embedded. The Junction Box shall be complies with requirements of the standards IEC 60998 - 1, IEC 60670 - 22 & IEC 60670 - 2 - 5. The Junction Box with Suitable Connectors or Terminal Trip. The manufacturer of Junction Box / Enclosure shall submit a copy of IEC Certificate.The JB Colour according to RAL 9011. The Junction Box supply as per approved make List in MES Junction Box category. For better safety the Polycarbonate enclosure and shall be fire retardant & self - extinguishing in accordance with IEC 60695 - 2 - 11, DIN VDE 0304 Part - 3, UL Subject 94 for Flammability V-2. It should be tested at Glow Wire test for 960 degree Centigrade & Current Carrying Capacity upto 102Amps. Junction Box with One No MCB 6Amp SP 10KA C-Curve for Manual operate to LED Light . The impact strength of Polycarbonate enclosure / boards i.e. the Degree of protection against mechanical load shall be in accordance with EN 50298 - 98 for IK 08 including Four Pole. connector for Cable Loop, 3 Nos PVC IP68 Suitable Glands as per Cable and Junction Box with Pole mounting clamps and nut bolts complete all as per manufacturer’s instructions.
Note: Manufacturer should submit routine test certificate of CJB/PJB as per above. | 8 | Each | - | - |
| 3 | Supply & fixing LED street light 90 W 230 volts with surge protection not less than 4 KV inbuilt in driver & minimum 10 KV separate in the light housing. Powder coated pressure die cast aluminium housing , IP-65/66 protection, high power LED street light with the heat resistant thoughened glass lens and making electrical connections pvc insulated sheathed 3 core 1.5 sqmm copper conductor from street light to junction box complete all as specified and directed.
Notes: Driver shall be potted antivibration type. LM-79 and LM-80 for 50000 burning hours. CRI(colour Rendring Index) of fixture shall be ≥ 70. CCT (colour correlated Temp) of fixture shall be 5700K±300K. System Lumen Efficiency shall be>100 Lm/W. 10 KV separate Surge protection shall be provided as a part of fitting. PCB used shall be MC PCB type. The fitting shall have arrangement so that maintenance required, if any can be carried out from Top cover. | 8 | Each | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.74 MB
97T.pdf
Tender Documents • 1.21 MB
BOQ_862569.xls
BOQ • 10.80 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .