| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.3 LAccepted-AOC 2 89 BIJOYGARH JADAVPUR KOLKATA 700032 | KOLKATA | KOLKATA | WEST BENGAL | 700032 | L1 | Accepted-AOC AOC ISSUED | |
| 2 | L2₹8.3 L+₹2,895 (0.35%)Rejected-Finance 3 C DR JAGABANDHU LANE KOLKATA 700012 | KOLKATA | KOLKATA | WEST BENGAL | 700012 | L2 | Rejected-Finance that the bid is not L1 | |
| 3 | L3₹8.7 L+₹41,026 (4.93%)Rejected-Finance | L3 | Rejected-Finance that the bid is not L1 |
Tender Value
₹10.4 L
EMD Value
₹20,800
Closing Date
3 Jun 2025, 1:00 pmClosed
EE-II KNHED PWDte.
KIT Building Annex, 4thFloor,P-16, India Exch. Place Extn., Kolkata 700073
Supply, Installation, Testing and Commissioning of Concealed Split type Air Conditioner inside 6 Nos. NBC Cabin at Top floor of CHTD Building under School of Tropical Medicine, Kolkata E.I Work
2025_WBPWD_846105_1
WBPWD/EE-II/KNHED/NIQ-05/2025 - 26
Open Tender
ELECTRICAL WORKS ORG
Item Rate
20 days
Kolkata
Please refer Tender documents.
5 documents required · 5 mandatory
₹20,800
OFFICE OF THE EE KNHED PWDte.
1 Jul 2025
14 May 2025
5 Jun 2025
14 May 2025
3 Jun 2025
21 May 2025
20 May 2025
Amount
Dismantling the existing E.I. work by Co's own tools & tackles and take unnecessary items away from site by maintening normalcy as far as possible as per direction of EIC .
Supplying and Delivery of following sizes Al. armoured PVC/XLPE cable (Havells/gloster/KEI) as mentioned below : a) 4 core 240 sqmm (from OPD Feeder Pillar Box to Proposed new AC PANEL INCOMER)
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of following XLPE/PVC armoured Al cables incl. finishing the end with Al socket (Dowels make), anticorrosive paste, tapes etc. a) 4 C x 240 sqmm A/Al cable
Finishing the end of following XLPE/PVC armoured cable by criping methode incl. S&F solderless socket (dowels make) tap, anticorrosive past & jointing material. a) 4 C x 240 sqmm A/Al cable
Supply,Installation,Testing & Commissioning of MCCB type LT Cubical floor cum wall mounted panel board having suitable size with Multi Compartment : one MCCB incoming, one busbar and 6 nos MCCB type outgoing main switches made with 16 SWG MS sheet and inter connections from incoming to busbar and busbar to outgoing with suitable size of Cu wire.The panel board should have proper cable ally both side with cable entry at bottom with suitable current rating of Terminal at incoming site and outgoing site. .The panel board should be painted by powder coated.The panel board consisting of the following :
Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (make-- Glostar/ Havells/KEI) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall complete with 2 no. suitable size “Ph & N” copper bar incl. bakelite/Perspex (wall matching color) top cover 3mm thick and incl. 175mmx100mmx65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish a)Average run 11 mtr
Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment as per GS (Make-Legrand/LK/Schneider/ABB/Siemens) a) 4 Way ( Up to 160 A )
Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA in existing Vertical DBs including necessary connection as per GS (Make-Legrand/LK/Schneider/ABB/Siemens) a) 160 A FP
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connections per GS (Make-Legrand/LK/Schneider/ABB/Siemens) a) 63 TP
Supplying and fixing 6 Way double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. (Make-Legrand/LK/Schneider/ABB/Siemens)
Supplying and fixing 63A Four Pole 415 V MCB Isolator on din rail of existing DBs and necessary connection (Make-Legrand/LK/Schneider/ABB/Siemens)
Supplying and fixing 10 - 32A 240 V SP MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection. (Make-Legrand/LK/Schneider/ABB/Siemens)
Supply of cables :--- Supplying and Delivery of following sizes Al. armoured PVC/XLPE cable (Havells/gloster/KEI) as mentioned below: a. 4 core 70 sqmm
Laying of cables :--- Laying of 4 core 240 Sqmm Al. armoured PVC/XLPE cable with 2X10 SWG GI wire making hole etc. as necy., mending good damages and painting as mentioned below: a) Laying of cable 4 core 240 sqmm on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting
b) Laying only Cable 4 core 240 sqmm through existing RCC/ Hume/GI Pipe/open masonary trench
c) Laying of 4 core 240 sqmm in underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoring surface duly ramme
Laying of 4 core 70 Sqmm Al. armoured PVC/XLPE cable with 2X10 SWG GI wire making hole etc. as necy., mending good damages and painting as mentioned below : . a. on wall by clamp
b. Concealed in wall
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : a. 4 core 70 sqm
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials a. 4 core 70 sqm
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush, etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire as per G.S. Vide page no C-3, Item no 21.a.
Miscellaneous :--- Supply and installation of 1-Phase timer in double door SPN DB (2+10) way providing incoming and outgoing copper wires and other accessories. The interconnection should be made by 4 sq.mm. copper wires. The box should be painted by powder coated paint. a) 25A DP MCB -1 No. (b)Analog time switch LK240 VAC Base/DIN Mounting cat no-- J648B1 - 1 No. (c) 2- pole single power contactor 250V, 25A coil (Legrand, cat no-- 4125-44) - 1 No. (d) Add-on auxiliary contact block(1 NO+1 NC) -1 no (e) 60A capacity 3 way AC/DC Epoxy terminal block.- 1 No. (f) Indicator Lamp (ESBEE make)-2 Nos. (g) Toggle switch,(ON_OFF_ON)- 1 No. (h) Steel Key Lock – 1 No. (Make- LK /ABB)
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire
Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Brand approved by EIC) & necy. Connections.
S/F of 230V Digital Control starter ( VOLTCHECK, AMPCHECK & TIMECHECK and 3-digit display) for room air conditioner type OLP 21A RAC machine(Electron/Ultratech) incl. S&F of 6 modular switch board
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (make-- Glostar/ Havells/KEI) of the following sizes in the prelaid polythene pipe/PVC Conduit Pipe and by the prelaid GI fish wire and making necy. connection as required a) 2 x 4 sqmm + 2 x 2.5 sqmm ( From HTPNDB to Timer & Timer to A.C)
Supplying and fixing PVC Rigid Conduit 'FR' [Precision Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building works a) 20 mm size
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes a) 4 Sqmm
b) 2.5 Sqmm
(Rate should be quotated including all taxes and duties, GST and considering the value of less cost materials.)
S. A. ENTERPRISE (BID ID -6502955)
AVO ENGINEERING ENTERPRISE (BID ID -6438901)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .