Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.5 LAccepted-AOC ROWRIAH KB ROAD PO CHALIHA JORHAT 785004 ASSAM | JORHAT | JORHAT | ASSAM | 785004 | ₹21.5 L Quoted ₹21.8 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹24.7 L+₹2.9 L (13.2%)Rejected-Finance | ₹24.7 L+₹2.9 L (13.2%) | L2 | Rejected-Finance Other than L1 |
| 3 | L3₹27.6 L+₹5.8 L (26.6%)Rejected-Finance | ₹27.6 L+₹5.8 L (26.6%) | L3 | Rejected-Finance Other than L1 |
| Sl No | Description | Qty | Unit | M/S DHAR AND DHAR L1 | NIHAR ENTERPRISE L3 | M/S BARUA REFRIGERATION WORKS L2 |
|---|---|---|---|---|---|---|
| 1.00 | Preventive and comprehensive maintenance as per Original Equipment Manufacturer's (OEM) recommendations of floor mounted package type air cooled AC plant of capacity 3x10 TR by cleaning of airfilters, condensor cleaning with coil cleaner, cleaning of all dampers of optimum cooling in every room, duct inspection and cleaning from inside, checking and rectification of control wiring, greasing of blower motor, checking all safety measures, topping of required refrigerant gas and compressor oil it retained as required, balancing of blower, etc. and including repair/replacement of unserviceable spare parts as and when required i.e.compressor of the package unit, micro processor control unit, indoor blower motor, outdoor fan motor, fan motor blade, condensor coils, airfilters, dampers, liquid line gas filter, charging valve, contactors, blower motor bearing, required size V-belts, leak test by nitrogen gas and charging the refrigerant as required at site including test run for 24 hours to achieve satisfactory service and designed condition test results in presence of Engineer-In-Charge complete all as specified and as directed.
Make : Blue Star installed at Avionics Lab (Package type Air Cooled AC plant). | 4 | PER QTR | 30,000 ₹1,20,000 Lowest | 95,500 ₹3,82,000 | 35,000 ₹1,40,000 |
| 2.00 | All as per Serial item No. 1 here-in-before but of capacity 3x11 TR.
Make : Voltas installed at CAN lab (Package type Air Cooled AC plant). | 4 | PER QTR | 32,000 ₹1,28,000 Lowest | 37,500 ₹1,50,000 | 35,000 ₹1,40,000 |
| 3.00 | All as per Serial item No. 1 here-in-before but of capacity 3x11 TR.
Make : Blue Star installed at DCN lab (Package type Air Cooled AC plant). | 4 | PER QTR | 32,000 ₹1,28,000 Lowest | 37,500 ₹1,50,000 | 38,000 ₹1,52,000 |
| 4.00 | All as per Serial item No. 1 here-in-before but of capacity 4x8.5 TR.
Make : Blue Star installed at Tarang Auditorium (Condensing type Air Cooled AC plant). | 4 | PER QTR | 33,000 ₹1,32,000 Lowest | 39,800 ₹1,59,200 | 40,000 ₹1,60,000 |
| 5.00 | All as per Serial item No. 1 here-in-before but of capacity 4x11 TR.
Make : Blue Star installed at Tarang Auditorium (Condensing type Air Cooled AC plant). | 4 | PER QTR | 42,000 ₹1,68,000 Lowest | 48,500 ₹1,94,000 | 48,000 ₹1,92,000 |
| 5.01Note : (For Serial Item No. 1 to 5) (i) The works shall be executed through OEMs authorised service centre engineers or through OEMs certified agencies as approved by GE on quaterly basis as well as during breakdowns. Contrator to provide necessary documents reflecting the same. (ii) The contractor shall be liable to maintain temperature and relative humidity as per the designed parameters or set parameters to acheive the desired HVAC conditions at all package/condensing unit locations by keeping the system fully functional. (iii) The cost of spares for any servicing, minor and major repair of the plant(s) as and when required or as recommende by the OEM during inspection/ analysis report is not inclusive and is catered seperately in subsequent items. If any spare parts/service which is crucial for running of plant but is missing in subsequent items is deemed to be included in quoted rates. (iv) The contractor shall deploy OEM's authorised one service engineer/technician alongwith with one helper covering all five sites for general shift duty of 08 (Eight) hrs on all working days including sunday(s) and holiday(s) to carry out daily maintenance/ checking of the system. | ||||||
| 6.00 | Supply and filling Gas with R-22 of approved manufacture and suitable for compressor of package type AC plant/unit at Avionics Lab & CAN Lab complete all as specified and as directed.
Make : Godrej, Floron, Maffron or equivalent make as per PS. | 70 | Kg | 1,800 ₹1,26,000 Lowest | 2,200 ₹1,54,000 | 2,000 ₹1,40,000 |
| 7.00 | Supply and filling Gas with R-407C/410 C of approved manufacture and suitable for compressor of condensing AC plant/unit at Tarang auditorium & package AC plant/unit at DCN Lab complete all as specified and as directed.
Make : Godrej, Floron, Maffron or equivalent make as per PS. | 122 | Kg | 1,700 ₹2,07,400 Lowest | 1,950 ₹2,37,900 | 1,900 ₹2,31,800 |
| 8.00 | Taking down defective compressor unit 11 TR capacity suitable for R-407C/R410/R22 refrigerant, 3 Phase 415 volt after disconnecting all electrical connections and replace the same with new compressor of same capacity and including flushing old gas and recharging with appropriate quantity of R-407/R410/R22 refrigerant gas complete all as specified and as directed.
Make : Copeland/Sanyo/Danfoss.
Note : Cost of refrigerant gas shall be measured and paid separately. | 2 | Each Job | 1,10,000 ₹2,20,000 Lowest | 1,28,000 ₹2,56,000 | 1,25,000 ₹2,50,000 |
| 9.00 | Taking down defective compressor unit 8.5 TR capacity suitable for R-407C/R410/R22 refrigerant, 3 Phase 415 Volt after disconnecting all electrical connections and replace the same with new compressor of same capacity and including flushing old gas and recharging with appropriate quantity of R-407/R410/R22 refrigerant gas complete all as specified and as directed.
Make : Copeland/Sanyo/Danfoss.
Note : Cost of refrigerant gas shall be measured and paid separately. | 2 | Each Job | 84,000 ₹1,68,000 Lowest | 89,000 ₹1,78,000 | 90,000 ₹1,80,000 |
Tender Value
Refer Docs
EMD Value
₹42,000
Closing Date
12 May 2026, 6:00 pmClosed
GE (AF) JORHAT
JORHAT
REPAIR/ MAINTENANCE OF PACKAGE TYPE AC PLANT ALONGWITH VARIOUS CONNECTED ITEMS AT AFS UNDER GE (AF) JORHAT
2026_MES_761419_1
8780/E8
Open Tender
Electrical and Maintenance Works
Item Rate
335 days
GE (AF) JORHAT
AS PER NIT
9 documents required · 9 mandatory
₹500
GE (AF) JORHAT
₹42,000
Yes
7 Aug 2026
22 Apr 2026
14 May 2026
22 Apr 2026
12 May 2026
6 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| - | Preventive and comprehensive maintenance as per Original Equipment Manufacturer's (OEM) recommendations of floor mounted package type air cooled AC plant of capacity 3x10 TR by cleaning of airfilters, condensor cleaning with coil cleaner, cleaning of all dampers of optimum cooling in every room, duct inspection and cleaning from inside, checking and rectification of control wiring, greasing of blower motor, checking all safety measures, topping of required refrigerant gas and compressor oil it retained as required, balancing of blower, etc. and including repair/replacement of unserviceable spare parts as and when required i.e.compressor of the package unit, micro processor control unit, indoor blower motor, outdoor fan motor, fan motor blade, condensor coils, airfilters, dampers, liquid line gas filter, charging valve, contactors, blower motor bearing, required size V-belts, leak test by nitrogen gas and charging the refrigerant as required at site including test run for 24 hours to achieve satisfactory service and designed condition test results in presence of Engineer-In-Charge complete all as specified and as directed.
Make : Blue Star installed at Avionics Lab (Package type Air Cooled AC plant). | - | PER QTR | - | - |
| - | All as per Serial item No. 1 here-in-before but of capacity 3x11 TR.
Make : Voltas installed at CAN lab (Package type Air Cooled AC plant). | - | PER QTR | - | - |
| - | All as per Serial item No. 1 here-in-before but of capacity 3x11 TR.
Make : Blue Star installed at DCN lab (Package type Air Cooled AC plant). | - | PER QTR | - | - |
| - | All as per Serial item No. 1 here-in-before but of capacity 4x8.5 TR.
Make : Blue Star installed at Tarang Auditorium (Condensing type Air Cooled AC plant). | - | PER QTR | - | - |
| - | All as per Serial item No. 1 here-in-before but of capacity 4x11 TR.
Make : Blue Star installed at Tarang Auditorium (Condensing type Air Cooled AC plant). | - | PER QTR | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.68 MB
8780tender.pdf
Tender Documents • 1.18 MB
BOQ_852902.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .