| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Rejected-Technical | Rejected-Technical Technically not at par |
| 5 | Rejected-Technical | Rejected-Technical Technically not at par |
Tender Value
Refer Docs
Closing Date
4 Aug 2021, 4:00 pmClosed
GM,Engg. Scope complex Lodhi road New Delhi
GM,Engg. Scope complex Lodhi road New Delhi
Construction of Tourist Facilitation Center at Chempazhanthy Gurukulam in Kerala
2021_ITDC_81056_1
ITDC/Engg/Chempazanthy/2021
Open Tender
Construction Works
Works
180 days
Scope complex Lodhi road new delhi
please refer to NIT
16 documents required · 16 mandatory
₹0
Exempted
23 Oct 2021
19 Jul 2021
5 Aug 2021
19 Jul 2021
4 Aug 2021
19 Jul 2021
Amount
Site Clearance Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared
Earth Work Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5 km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches plinth, sides of foundation etc. complete.
Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos / Lidaane emulsifiable concentrate of 20%.
Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Along external wall where the apron is not provided using chemical emulsion @ 7.5 litres / sqm of the vertical surface of the substructure to a depth of 300 mm including excavation channel along the wall & rodding etc. complete: With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration
Plain Cement Concrete Providing and laying in position cement concrete of specified grade excluding cost of centering and shuttering - All work up to plinth level :1:4:8(1 Cement :4 Coarse Sand : 8 Graded stone aggregate of 40mm)
Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand(zone-III) : 4 graded stone aggregate 20mm nominal size).
Stone work Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand).
Reinforced Cement Concrete Centering and Shuttering :- Centering and shuttering including strutting, propping etc. and removal of form for :Lintels, beams, plinth beams, girders, bressumers and cantilevers:
Reinforced cement concrete work in beams suspended floors, roofs having slope upto 150 landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral staircases above plinth level up to floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand (Zone-III): 3 graded stone aggregate 20 mm nominal size) (above ground level).
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placingin position and binding all complete above plinth level. Thermo-mechanically treated bars of grade Fe-500D or more.
Masonry Work Providing and fixing up to floor five level precast cement concrete solid block, including hoisting and setting in position with cement mortar 1:3 (1 cement : 3 coarse sand), cost of required centering, shuttering complete : 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size) .
Wood and PVC Work Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately).Second class teak wood
Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. Second class teak wood 30 mm thick shutters
Providing and fixing glazed shutters for door, windows and clerestory windows using 4 mm thick float glass panes including ISI marked M.S. Pressed butt hinges bright finished of required size with necessary screws. Second class Teak wood 30 mm thick
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings/ wooden frames with rawl plugs screws etc
Providing and Fixing factory made PVC door frame made of PVC extruded sections of size 75 mm x 53 mm, having wall thickness 2.0 mm (± 0.2 mm) Both vertical sides of the frame reinforced with PVC profile of cross section size 28 mm x 30 mm x 2 mm thickness (± 0.2 mm ) and 75 mmx 200 mm long, including reinforcing both ends of the top frame with PVC profile. PVC Door Frame and PVC reinforcement profile to be mitred cut jointed and fusion welded together, including providing and fixing 3 nos of 125 mm long stainless steel hinges to frame, fixing the frame with jamb with required nos & sizes of anchor dash fastener, all complete as per manufacturer's specification and direction of engineer-in-charge.
Providing and fixing 37 mm thick factory made PVC Door shutter, styles and rails made of PVC hollow extruded printed and laminated section having overall dimension 115 mm x 37 mm with wall thickness 2 mm ( +- 0.2 mm) with inbuilt beading on one side, the styles and rails mitred cut and joint at corners by inserting 2 nos PVC profile reinforcement of size 75 mm x 200 mm long with cross section size of 28 mm x 30 mm having wall thickness 2 mm (+- 0.2 mm). Styles, rails and reinforcements to be fusion welded together. Only hinges side vertical style to be reinforced with PVC profile reinforcement in full length, Printed and laminated PVC lock rail of size 110 mm x 37 mm having wall thickness 2 mm (+- 0.2 mm) to be welded horizontally with the vertical styles after inserting PVC profile reinforcement as in styles and rails, providing with PVC snap fit beading, panels of 100 x 20 mm printed & laminated and inserting 2 nos 6 mm dia bright steel rod horizontally with both side threaded and tightened with check nuts and washers complete, all as per manufacturer's specification and direction of engineer-in-charge.
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 200x10 mm
Providing and fixing chromium plated brass butt hinges with necessary chromium plated brass screws etc. complete100x70x4 mm (ordinary type)
Providing and fixing bright finished brass hard drawn hooks and eyes : 100 mm
Providing and fixing bright finished brass 100 mm mortice latch and lock with levers and a pair of lever handles of approved quality with necessary screws etc. complete.
Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size).
Steel work :- Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes
Flooring:- Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete.
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineerin- Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1cement : 4 coarse sand) : 25 mm thick
Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.
Roofing Providing & fixing on roof pressed clay tile (Mangalore tile) of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately).
Providing & laying on roof pressed clay tile ridge (Mangalore tile) of 20mm thickness and of approved pattern on steel frame work complete (steel frame work to be paid separately).
Providing and fixing 15 cm wide, 45 cm overall semi-circular plain G.S. sheet gutter with iron brackets 40x3mm size, bolts, nuts and washers etc., including making necessary connections with rain water pipes complete. 0.80 mm thick with zinc coating not less than 275 gm/m²
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50 x 50 x 50 mm hardwood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm dia
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion a)Bend 87.5o 110 mm bend
b)Shoe(plain):110mm
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.
Finishing 12 mm cement plaster of mix : 1:6 (1 cement:6 fine sand)
Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.
Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work
Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) : Flush/ Ruled pointing
Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: (i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. (ii) IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of ertical and horizontal surface. (iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area. (iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm).
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work
Plumbing Works Sanitary installation Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.l.brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required: W.C. pan with ISI marked white solid plastic seat and lid
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Flat back wash basin size 550x 400 mm with single 15mm C.P. brass pillar tap
Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 453x357 mm
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 15 mm nominal bore
Providing and fixing rigid PVC multi floor trap of self cleaning design with PVC screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors. 110 inlet and 110 mm outlet
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width78 mm and effective height of 88 mm, weighing not less than 190 gms.
Providing and fixing CP brass health faucets with 8mm dia 1.2 mtr long flexible tube and wall hook complete as directed by the Engineer in charge at all levels.
Providing and fixing PTMT liquid soap container 109 mm wide, 125mm high and 112 mm distance from wall of standard shape withbracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
Supplying, laying and jointing hard PVC pipes with PVC specials such as tees, bends, door bend, door tee, elbow, unions, etc. with clamp testing the lines rectifying any leakages or defects etc. complete as directed by the Engineer in charge for soil, waste, drains, vent pipe, etc. concealed or open at all levels including cost conveyance of all materials , labour charges, sundries etc. complete as directed by the Engineer in charge. a) 160 mm (6Kg/cm2)
b) 110mm (6kg/cm2)
c) 75mm (6kg/cm2)
d) 75mm (4kg/cm2)
e) 50mm (6kg/cm2)
Providing and fixing PVC vent cowl to pipe already fixed as directed by Engineer in charge at all levels, 110 mm dia
Water Supply Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. a) 20 mm nominal outer dia Pipes
25 mm nominal outer dia Pipes
32 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work. a) 40 mm nominal outer dia Pipes
50 mm nominal outer dia Pipes
62.50 mm nominal inner dia Pipes
150 mm nominal inner dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall. a) 20 mm nominal outer dia Pipes
25 mm nominal outer dia Pipes
32 mm nominal outer dia Pipes
40 mm nominal outer dia Pipes
50 mm nominal outer dia Pipes
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 20 mm nominal bore
25 mm nominal bore
32 mm nominal bore.
40 mm nominal bore
50 mm nominal bore
65 mm nominal bore
80 mm nominal bore
Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 100x100 mm size P type With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.:
Providing and fixing gun metal non- return valve of approved quality (screwedend) : a) 40 mm nominal bore Horizontal
50 mm nominal bore Horizontal
65 mm nominal bore Horizontal
Electrical Estimate for Chempazanthy TFC METERING PANEL :- SITC and fabrication of double door feeder Piller size 1000X1000X300 deep powder coated made out of 1.6 mm thick CRCA sheet i/c aluminium Bus-Bar, angle iron frame, copper links, nut bolts washers, panel locks, internal wiring with copper conductor wire, thimbles, ferrules, cable ties, PVC Channel, MCB channels etc. as required. 1 sqm. Following Material to be Fixed in Panel:-For Main 200Amp. 50KA FP MCCB with 200Amp – 250Amp Thermal release range. no. For Main 100Amp. 50KA FP MCCB with 100Amp – 150Amp Thermal release range. nos.Spreaders 8Pc set for 200Amp FP MCCB 01 setSpreaders 8Pc set for 100Amp FP MCCB 01 set SP MCB 6A / 10A 04 nos.LED Indication Light Red & Yellow (22.5mm) 04 nos. LED Indication Light Blue (22.5 mm) 01 no.Power Contactor 110Amp MNX 110 01 no. ADD – ON Auxiliary Contact 01 no.Time switch 01 no.On Off Push button with element 02 nos. Auto manual switch 01 no.Multifunction Meter 96 sq.mm square 01 no.CT 200/5Amp 03 nos.Power & control wiring with copper wires, copper strip, insulators, Copper Thimble, fuel, PVC Sleeves, PVC channels, Nut Bolts, Cable Tie etc
DISTRIBUTION BOARD :- Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 Volts, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder, painted including earthing etc. as required. (But without MCB/RCCB/Isolator). All distribution board should be with the space provision for RCCB. 12 way , Double door
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a)Single Pole SP MCB
(b)Double Pole 32 Amps
Supplying and fixing of 63 amps rating, double pole, (single phase and neutral), 240 Volts, residual current circuit breaker (RCCB), having a sensitivity current upto 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
LT CABLES & TERMINATION LT CABLES Supply, Laying, Testing and Commissioning of following 1100V XLPE A2XFY (XLPE insulated Armoured Aluminium) / YFY (Armoured Copper) / YY (Unarmored/Flexible Copper) cables laid over MS supports / Cable racks / in excavated Trench / fixing of walls including clamping the cable to the support in all approved manner as all complete required (Note : Inclusive of supply of Anchor Fasteners, straight through joints and necessary 1.5mm thick GI Flat, clamps shall be included in the laying cost). (a)3.5C 35 Sq.mm. A2XFY - XLPE
(b)4C 25 Sq.mm. A2XFY - XLPE for PANELS,
(c)4C 16 Sq.mm. A2XFY - XLPE for ,PDBs etc
(d)4C 10 Sq.mm. XLPE cu. Ar. Cable for Extract fans,,LDBs,AHUs etc
(e)4C 16 Sq.mm. XLPE cu. Ar. Cable for Extract fans,,LDBs,AHUs etc
(f) 4C 6 Sq.mm. XLPE cu. Ar. Cable for Extract fans,PDBs,LDBs,AHUs etc
TERMINATION LT CABLE TERMINATION Supply erection, Termination of PVC insulated armoured / unarmoured cables up to 1100V grade and connection of leads including the supply of Aluminum/COPPER cable lugs but including cutting stripping of cable insulation, providing double compression type glands, terminals, and armour earthing ,crimping the lug on to the conductor, clamping of the cable-cores, marking with wire number ferrules, etc.with Gland hood to be provided at the cable end entering to the Main panel and including all labour and materials complete and as per specifications of this tender and directions of Engineer-in-charge. End Termination of Cable using jointing kits & accessories as recommended by cable/ kit manufacturer. (a) 9.1.21 3.5C 35 Sq.mm. A2XFY - XLPE
(b) 9.1.34 4C 25 Sq.mm. A2XFY - XLPE for PANELS,
(c)9.1.33 4C 16 Sq.mm. A2XFY - XLPE for ,PDBs etc
(d)9.1.32 4C 10 Sq.mm. XLPE cu. Ar. Cable for Extract fans,,LDBs,AHUs etc
(e)9.1.33 4C 16 Sq.mm. XLPE cu. Ar. Cable for Extract fans,,LDBs,AHUs etc
(f)4C 6 Sq.mm. XLPE cu. Ar. Cable for Extract fans,PDBs,LDBs,AHUs etc
WIRING - CIRCUIT CUM POINT WIRING Primary Light / Fan Point Wiring: Supply, wiring, connecting & commissioning of 3Runs 1.5 Sq.mm. (Ph, Neutral & Earth) PVC insulated multistranded FRLS copper wires in 1.8mm thick MS conduits fixed on ceiling partly and 1.8 mm thick PVC conduit concealed in the wall partly with necessary clamps, screws, etc., as required as per the site condition including supplying and fixing of modular 6A One way switch along with moulded front plate in GI anodised manufacturer's mounting box fixed flush with the wall complete with all accessories including 3 plate ceiling rose.NOTE: Above false ceiling when it is open wiring it should be of MS conduit and for Vertical and horizontal drops concealed PVC conduits can be used. Accordingly the length of the conduit can be calculated.
Secondary Light Points: Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Secondary Light Points: Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Lighting Circuit Mains: Supply and laying of 3 Runs 2.5 Sq.mm. (Ph, Neutral & Earth) PVC insulated multistranded FRLS copper wires in 1.8mm thick MS conduits fixed on ceiling partly and 1.8 mm thick PVC conduit concealed in the wall partly with necessary clamps, screws, etc., as required as per the site condition., from LDB to Lighting Switch Boards and MCB to First Light Point.
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.2 X 4 sq. mm + 1 X 4 sq. mm earth wire
Supply & Laying of 2R 2.5sqmm and 1R 2.5 Sq.mm. PVC insulated FRLS multistranded cu wires in the 20mm dia 2mm thick PVC conduits with all accessories as reqd. (From DB to 6A Switch & Sockets)
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 10 sq. mm + 1 X 6 sq. mm earth wire
C0NDUt MS CONDUIT: Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. (a)20 MM
PVC CONDUIT: Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required (a) 20 MM
MODULAR BOX,PLATE,SWITCH,SOCKETS Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required
Supplying and fixing brass batten/ angle holder including connection etc. as required
a) 25A, 3 pin socket outlet controlled by 20A 2P RCCB.(for AC Units)
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required (a) 5/6 A switch
(b) 2 way 5/6 A switch
(c ) 15/16 A switch
(d)3 pin 5/6 A socket outlet
(e)6 pin 15/16 A socket outlet
Telephone socket outlet
TV antenna socket outlet
Bell push
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required 1 or 2 Module (75mmX75mm)
3 Module (100mmX75mm)
4 Module (125mmX75mm)
6 Module (200mmX75mm)
8 Module (125mmX125mm)
12 Module (200mmX150mm)
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.(a) 1 or 2 Module
3 Module
4 Module
6 Module
8 Module
12 Module
EARTHING Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
Supply and clamping the following sizes of strips on surface of wall / parapet/ existing cable tray using clamps fabricated from 20 x3 mm GI flat duly painted or heavy duty GI spacer saddles, spacing of clamps not exceeding 1 m , making good the damages, colour washing etc. as required ( for vertical run).20 x 3 mm GI strip
CABLE TRAY:Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not Less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including bends,Cross member,Reducer ,Tee, G.I. bolts & nuts, etc. as required. (a) 150 mm width X 50 mm depth X 1.6 mm thickness
(b)300 mm width X 50 mm depth X 1.6 mm thickness
Supplying, fixing, LT cable route markers with 10 cm x 10 cm x 5mm. thick CI plate with inscription thereon, bolted / welded to 35mm x 35 mm x 6 mm. angle iron , 60 cm. long and fixing the same in ground as required. The cable route marker shall be fixed at both the ends of cable at joints and at 100 Mts. spacing for straight runs.
LIGHT FITTING AND FANS Supply conveyance, installation, testing and commissioning the light fittings of following types made from CRCA sheet 0.5mm thickness with all accessories and lamps directly on wall and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required1200 mm 1X20W LED Lamp with box type fixture complete with all fittings or as approved make
Supply conveyance, installation, testing and commissioning the light fittings of following types made from CRCA sheet 0.5mm thickness with all accessories and lamps directly on wall and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required1200 mm 1X40W LED water proof Lamp with box type fixture
Supply, conveyance, installation, testing and commissioning of Recess/Surface mounted circular /square LED down lighter with housing made up of white powder coated, pressure die cast aluminium for better heat management. Height Transitivity Polycarbonate diffuser for uniform light distribution, white rim moulded in engineering plastic, driver pre wired up to terminal block, CRI>80, LED efficacy>170lm/W, Color temperature- 6500K, IP20, 50000 burning hours as per L70 Criteria, Ambient temp-0 to 50DegC, Driver efficiency>85%, THD<10%, Powerfactor>0.95, Surge protection in CM- 2KV, Multistage Isolated Constant Current - Constant Voltage operated driver with range 150-270V AC and Safety Extra Low Voltage Safe level<60V DC as per IEC standard.Circular recess mounted/squrerecess mounted,Wattage ≤ 11-18W recess mounted with luminaire lumen &gee; 820lm and System Efficacy ≥ 75lm/W.and including charges for cutting holes & frame for Gypsum/POP ceiling and.giving connection with 3 core round flex wire etc complete
Supply, conveyance, installation, testing and commissioning of Recess mounted full panel LED luminaire with Multi Angular design on diffuser White powder coated housing & frame in CRCA sheet, High efficiency LED grade diffuser, electronic driver duly wired up to terminal block, CRI>80, Colour temperature- 5600-5900k IP20, 50000 burning hours as per L70 Criteria, Ambient temperature-0 to 50DegC, Driver Efficiency>90%, THD<15%, Powerfactor>0.9, Surge protection in CM-2KV, Model Multistage isolated Constant current-Constant voltage operated driver with range 150-270V AC and Safety extra low voltage safe level<60V DC as per IEC Standard.2ft x 2ft, Wattage ≤ 31- 40W recess mounted with luminaire lumen ≥ 3000lm and system efficacy>90lm/W.and including charges for cutting holes & frame for Gypsum/POP ceiling and.giving connection with 3 core round flex wire etc complete.
SITC of 1 X10 watt bulkhead light with dia cast aluminium housing with complete assembly and PC opal diffuser for uniform illumination. Suitable for surface/wall mounted application rated IP65 5700 CTC (K)
Supply, fixing, testing & commissioning of 40W LED for WALL light luminaires with IP66 with necessary fixing suitable fixing of GI pipe & clamp required.
SITC of 450 mm ( 18") sweep swing hi speed wall mounted Fans complete with all fittings or as approved make
Supply, conveyance, installation, testing and commissioning of the 300 mm exhaust fans in the existing opening, fixing necessary bolt and nuts, making good the damages etc. as required including giving connections with required length of 24/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant ISS,305 mm, single phase, heavy duty, 1400 rpm exhaust fan in metal frame
SAFETY ITEMS Safety items-Supply, erecting and connecting a 5 KG ABC fire extinguisher powder type properly fixed on the wall with necessary clamps, screws, bolts and nuts etc. The extinguisher shall be suitable for all types of fires (A, B & C).
Supply, erecting and connecting a 4.5 KG CO2 fire extinguisher properly fixed on the wall with necessary clamps, screws, bolts and nuts etc. The extinguisher shall be suitable for all types of fires (A, B & C).to TAC norms
Supply and providing St John make first aid box 18SWG MS sheet duly painted as approved by Indian red cross society complete with all first aid medicines
Supply, erecting and connecting laminated shock treatment chart both in English ,Hindi, and Malayalam directly fixed in the glazed frame on to the wall with necessary screws on all four corners.
RP PROJECTS PRIVATE LIMITED
ABDASSALAM M
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .