Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.3 LAccepted-AOC 840 1B MADHUR VIHAR COLONY CIVIL LINES JHANSI UP 284 001 | JHANSI | JHANSI | UTTAR PRADESH | 284001 | L1 | Accepted-AOC Accepted being lowest bidder | |
| 2 | L2₹26.8 L+₹2.2 L (8.79%)Rejected-Finance A 63 ELDECO COUNTY PHASE II RAJGARH JHANSI U P 284135 | JHANSI | JHANSI | UTTAR PRADESH | 284135 | L2 | Rejected-Finance Not become lowest bidder | |
| 3 | L3₹28.7 L+₹4.0 L (16.1%)Rejected-Finance BUNGLOW NO 75 CAVALRY ROAD JHANSI CANTT PIN 280001 | JHANSI | JHANSI | UTTAR PRADESH | 280001 | L3 | Rejected-Finance Not become lowest bidder | |
| 4 | L4₹32.2 L+₹7.5 L (30.5%)Rejected-Finance | L4 | Rejected-Finance Not become lowest bidder | |
| 5 | L5₹32.9 L+₹8.2 L (33.2%)Rejected-Finance | L5 | Rejected-Finance Not become lowest bidder |
Tender Value
Refer Docs
EMD Value
₹80,000
Closing Date
19 Nov 2020, 6:00 pmClosed
Major Deepak Kumar
Garrison Engineer Jhansi
REPAIR, MAINT, RENEWALS TO FLOOD LIGHTS, SECURITY LIGHTS, PAINTING OF POLES, RENEWAL OF EARTHINGS ETC AND OTHER MISC WORKS AT JHANSI CANTT, AAU, CALEB VIHAR AREA UNDER AGE E/M AT GE JHANSI
2020_MES_388360_1
GE/JHA/TOK/45 OF 2020-21
Open Tender
Civil Works
Item Rate
180 days
GE Jhansi
Please refer tender documents
6 documents required · 6 mandatory
₹500
Yes
GE Jhansi
₹80,000
Yes
29 Dec 2020
20 Oct 2020
25 Nov 2020
20 Oct 2020
19 Nov 2020
5 Nov 2020
Amount
Taking down the defective LED Flood light fitting/High bay light fitting / street light fitting/ security light fitting of various wattage from 70 Watts to 200 Watts from 9m/11m pole/ Workshop roof / Aircraft Hangar roof /Building walls etc from any position/ height and indentifying the fault and replacing the defective LED driver/replacing the burnt wiring and re-assembling the fittings and re-fixing in its original position and testing for proper functioning complete all as directed by Engineer-in- Charge. Note: Supply only of LED driver and Supply and replacement of cable shall be measured and paid separately under relevant items of BOQ.
Supply only of LED driver as per sample suitable for existing make & model of 200 Watt LED flood light / high bay light fitting. Make : Pyrotech / Surya / Halonix / Havells / Bajaj / Wipro
Supply only of LED driver as per sample suitable for existing make & model of 150 Watt LED flood light fitting. Make : Pyrotech / Surya / Halonix / Havells / Bajaj / Wipro
Supply only of LED driver as per sample suitable for existing make & model of 100 Watt LED flood light fitting. Make : Pyrotech / Surya / Halonix / Havells / Bajaj / Wipro
Supply only of LED driver as per sample suitable for existing make & model of 120 Watt LED street light fitting. Make : Pyrotech / Surya / Halonix / Havells / Bajaj / Wipro
Supply only of LED driver as per sample suitable for existing make & model of 90 Watt LED street light fitting. Make : Pyrotech / Surya / Halonix / Havells / Bajaj / Wipro
Supply only of LED driver as per sample suitable for existing make & model of 70 Watt LED street light fitting. Make : Pyrotech / Surya / Halonix / Havells / Bajaj / Wipro
Material and labour for overhauling of existing 16 meters height high mast lighting system by degreasing and cleaning of double drum winch, gear box, wire rope, clamp, bobbin arrangement, power tool motor, mechanical torque limiter, lowering the mast head assembly, degreasing and cleaning the pulley, docking arm etc and applying new grease / lubricating oil for all mechanical moving / rotating parts, checking all the electrical parts such as timer panel, all cable connections in control panel, motor, junction box, flood light fittings & aviation obstruction light fitting etc, rectifying the defects, renewing the defective components etc including testing for proper functioning complete all as specified and directed by Engineer-in-Charge. Note: Replacement of flood light fittings, aviation obstruction light, control cable, steel wire rope , timer panel components & rewinding of motor if required at site shall be measured and paid separately. However, the cost of minor spare parts & lubrication is deemed to be included in the quoted rate.
Supply and fix in replacement of 150 Watt LED flood light fitting made up of Pressure die-cast aluminium alloy housing with toughened glass, IP65 protection and impact resistance of IK07 and individual high power LEDs with secondary optics having system lumen efficacy ≥100 lm/W, Inbuilt potted electronic LED driver with APFC (SMPS based constant current supply), lower THD, Open Circuit protection, Over Voltage protection, Surge Voltage protection & other safety test as per IS 15885 Part-2/Sec 13 and BIS complying including surface mounting using adjustable MS cradle of thickness 5 mm provided with the fixture including taking down existing unserviceable flood light fitting of any description complete all as specified and directed by Engineer-in-Charge. Make: Havells / Philips / Wipro / Bajaj
All as per Serial Item No. 9.00 here-in-before but of 100 Watt LED flood light fitting. Make: Havells / Philips / Wipro / Bajaj
All as per Serial Item No. 9.00 here-in-before but of 50 Watt LED flood light fitting. Make: Havells / Philips / Wipro / Bajaj
Supply and fix in replacement of Integral LED aviation light fitting comprising of aluminium housing with polycarbonate enclosure including taking down existing unserviceable aviation light of any description complete all as specified and directed by Engineer-in-Charge. Make : Havells / Philips / Wipro / Bajaj
Supply and connecting in replacement of PVC insulated and PVC Round Sheathed, Copper Conductor (flexible) industrial cable 5 core x 4 sqmm, 1100 Volt, conforming to IS 694 including taking down of existing unserviceable copper control cable of any description complete all as specified and directed by Engineer-in-Charge. Make: Havells / Polycab / Finolex / KEI / Gloster / Universal
Supply and fixing in replacement of round strand galvanized steel wire rope conforming to IS:2266/02 of size 8mm dia, 6/36 SW construction including taking down existing unserviceable wire rope of any description complete all as specified and directed.
Supply and fixing in replacement of analog time switch, 3 module size suitable for automatic switching ON & OFF of street lights through 3 pole power contactor including taking down existing unserviceable time switch of any description complete all as specified and directed by Engineer-in-Charge. Make: L&T / C&S / Havells
Supply and fix in replacement of reversing starter with Forward, OFF and Reverse switch 25A suitable for three phase power tool motor of high mast lighting system including taking down existing unserviceable reversing starter of any description complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of three pole AC power contactor, 32 Amps, 415 volts suitable for street light timer panel including taking down existing unserviceable power contactor of any description complete all as specified and directed by Engineer-in-Charge. Make: L&T / Havells / C&S / BCH
Supply and fix in replacement MCB, TPN, 40 Amps, 10 KA, 415 V, 50 Hz, AC including taking down existing unserviceable MCB of any description complete all as specified and directed by Engineer-in-Charge. Make: Havells / C&S / L&T
Supply and fix in replacement Auto/ Manual with centre off switch suitable for street light timer panel including taking down existing auto / manual switch of any description complete all as specified and directed by Engineer-in-Charge.
Cutting and removing of burnt out winding from electric motor of any make and rewinding with super enameled copper winding wire of existing gauge and number of turns including varnishing, heating etc and testing for satisfactory performance for capacity up to 3.0 HP, 3 Ph, 415 Volts, 50Hz, AC motor complete all as directed by Engineer-in-Charge.
Supply, fixing, installation & testing of All-in-one integrated solar street light with built in 15 Watt LED light, Mono Crystalline SPV Panel, Lithium Ferro Phosphate (LiFeP04) battery, MPPT charge Controller and PIR sensor with colour temperature 6000-6500K including taking down existing unserviceable solar street light fitting of any description complete all as specified and directed by Engineer-in-Charge. Make: Havells / Philips / Wipro / Bajaj
Supply and fix in replacement of Circular LED Highbay light fitting 200 Watts, Integral product with LED, driver, aluminium heat sink for better thermal management, Polycarbonate high transmitivity lens and 3 core wire out for input power, with IP65 degree of protection, including taking down existing highbay light fitting of any description at any height from workshops / aircraft hangars complete all as specified and directed by Engineer-in-Charge. Make: Havells / Philips / Wipro / Bajaj / Osram
Supply and fix in replacement of 60 Watt LED street light fitting made up of Pressure die-cast aluminium alloy housing with toughened glass, IP66 protection and impact resistance of IK07 and individual high power LEDs with secondary optics having system lumen efficacy ≥100 lm/W, Inbuilt potted electronic LED driver with APFC (SMPS based constant current supply), lower THD, Open Circuit protection, Over Voltage protection, Surge Voltage protection & other safety test as per IS 15885 Part-2/Sec 13 and BIS complying including taking down of existing unserviceable street light fitting of any description complete all as specified and directed by Engineer-in-Charge. Make: Havells / Philips / Wipro / Bajaj
All as per item No. 23.00 here-in-before but of 100 Watt LED street light fitting. Make: Havells / Philips / Wipro / Bajaj
Supply and fix in replacement of LED Post top light fitting 45 Watt / 50 Watt, made in die-cast aluminum housing with decorative clear opal acrylic diffuser, IP 65 protection, spun aluminum powder coated canopy, low power Warm White (WW) LEDs connected in series and parallel combination with better heat dissipation arrangement with LED color temperature- 3000K ±300K, Highly efficient constant current electronic driver having operating voltage range from 140-280 Volt AC, provided with high voltage, open and short circuit protection, Voltage surge protection 5KV complete suitable for up to 60mm OD pipe entry with fixing bolts including taking down existing unserviceable post top light of any description complete all as specified and directed by Engineer-in-Charge. Make: Havells / Philips / Wipro / Bajaj
Supply and fix in replacement of GI pipe bracket made out of 40mm dia medium grade GI pipe of 1.50mtr long bent to required shape and fixed to steel tubular / PCC pole with clamps made out of 40mm x 5 mm MS flat fixed with suitable nuts, bolts and washers etc including taking down existing unserviceable bracket of any description complete all as specified and directed by Engineer-in-Charge.
Supply and connect in replacement of PVC insulated and PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volts grade, conforming to IS 694, three core, 2.5 sqmm for connecting from junction box to street light fitting complete all as specified and directed by Engineer-in-Charge. Make: Finolex / Havells / Polycab / RPG / KEI / Universal / Gloster
Supply and connect in replacement of PVC insulated and PVC sheathed aluminium conductor, unarmoured cable 4 sqmm, 3 core, 1100V grade complete connecting on overhead line and street light fitting as per site requirement and testing on completion. Make: Finolex / Havells / Polycab / RPG / KEI / Universal / Gloster
Material and labour for preparation of old painted surfaces of HT / LT steel poles and painting with one coat of aluminium paint on all steel surfaces such as poles, channels, angles, clamps, nuts, bolts and washers of any description and Zebra marking on pole with black paint up to one meter height above PCC coping including pasting of radium reflector band / strips (Make: 3M or equivalent) of 5cm wide in Green (02 Nos) & White (01 No.) colour shall be provided at a height of 1.25mtr from coping of pole and writing the pole number in black colour on yellow background at a suitable place on the pole including applying one coat of snow cem on PCC coping of pole complete all as specified and directed by Engineer-in-Charge.
Material and labour for Chemical Earthing complete with copper earth plate electrode of size 900mm x 600mm x 5 mm thick buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level connecting to copper earth strip of size 50mm x 6mm as earthing lead by means of copper bolts, nuts, check nuts and washers and earth strip protected by 80mm dia GI pipe medium grade and connected to power transformer / HT panels /earthing test point all as shown in electrical plate No. 3 of SSR Part-I(2009) and testing on completion complete all as specified and directed. Note :- (i) The quoted rate shall be inclusive of filling the earth pit with Sodium Chloride - 200 Kg, Magnesium and Copper Sulphate - 100 Kg and balance Charcoal in layers upto 15 cm above the top edge of the earth plate complete all as directed. (ii) The unit rate quoted shall also include for excavation, earth work in any type of soil, plain cement concrete 1:3:6 mix, Type C1 pit, 40mm thick RCC 1:2:4 mix type B1 cover reinforced with 8mm dia TMT bras @ 150mm C/C both ways, GI funnel with watering pipe, wire mesh, protection pipe, earth strip up to 7.50m long complete in addition to item No. 1(a) to (e) of preamble (Notes) under sub heading earthing, specified in SSR Part II
Supply and connect in replacement of Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required with 50mm x 6mm copper strip complete all as specified and directed by Engineer-in-Charge.
Material and labour for earthing complete with galvanized iron earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level connecting to GI wire 4mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel and earth wire protected by 15mm dia GI pipe medium grade and connected to pole structure/ panel board/earthing test point all as shown in electrical plate No. 3 of SSR Part-I(2009) and testing on completion complete all as specified and directed. Note :- The unit rate quoted shall also include for excavation, earth work in any type of soil, salt and Charcoal, plain cement concrete 1:3:6 mix, Type C1 pit, 40mm thick RCC 1:2:4 mix type B1 cover reinforced with 8mm dia TMT bras @ 150mm C/C both ways, GI funnel with watering pipe, wire mesh, protection pipe, earth strip up to 7.50m long complete in addition to item No. 1(a) to (e) of preamble (Notes) under sub heading earthing, specified in SSR Part II
Supply and connect in replacement of Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required with 4mm dia galvanized iron wire complete all as specified and directed by Engineer-in-Charge.
M&L for PCC 1:2:4 type B1 using 20mm graded stone aggregate as in coping including necessary form work complete all as specified and directed by Engineer-in-Charge.
ROHIT ENTERPRISES
m/s ramesh saran agarwal
Bal Singh and Sons
jay maa engineers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .