Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.4 LAccepted-Finance NEAR BANGLA VILLAGE DHANANA TEHSIL AND DISTRICT BHIWANI 127031 | BHIWANI | BHIWANI | HARYANA | 127031 | L1 | Accepted-Finance ACCEPT | |
| 2 | L2₹37.7 L+₹10.3 L (37.6%)Rejected-Finance VPO JAGRAM BASS TEHSIL BADHRA DISTT CH DADRI 127308 | JAGRAM BASS | CHARKHI DADRI | HARYANA | 127308 | L2 | Rejected-Finance REJECT |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
9 Nov 2020, 5:00 pmClosed
Executive Engineer HSVP
Poly clinic building sector 9A Bahadurgarh
Special Repair of 2 MGD water treatment plantat main water works sector 7 Bahadurgarh Repair of Structure Cleaning of Tanks Replacing Filter Media and Repairing of Alum dosing section and compressor units of 2 MGD Water Treatment Plant at sector 7
2020_HBC_149171_1
job no 2340 (Re call)
Open Tender
Civil Works - Others
Works
90 days
Bahadurgarh
Special Repair of 2 MGD water treatment plantat main water works sector 7 Bahadurgarh Repair of Structure Cleaning of Tanks Replacing Filter Media and Repairing of Alum dosing section and compressor units of 2 MGD Water Treatment Plant at sector 7
2 documents required · 2 mandatory
₹1,000
Yes
₹50,000
Yes
19 Nov 2020
29 Oct 2020
10 Nov 2020
29 Oct 2020
9 Nov 2020
29 Oct 2020
Amount
NS Item/ Providing and fixing of new flocculators with 80mm main shaft and double stage agitators
NS Item/ Providing and fixing of 1 HP motor and it’s gear box including oil, belts and pulley etc. complete (1:15)
NS Item/ Providing and fixing of 3 HP motor and its gear box (1:10)
NS Item/ Providing and fixing of New panel with 4 Nos. Starters for above said system including amp. Meter, SPP, indicating lights, incomer MCCB 125 Amp and all other works as per company standard
NS Item/ Desilting and cleaning of flocculators chambers approx. 90 cum L.S.
NS Item/ Chemical treatment of all sides of walls approx. 1530 Sqm area for surface treatment by applying 3 coats of bleaching powder including cost of labour and tools etc.
App Item/ Taking out of replaced filter media from filter bed including stacking & replacing the same in horizontal layers cleaning complete in all respect. (Filter size 4 Nos. 7m X4m) (a) Fine sand 0.45mm to 0.60mm top layer 0.95 Mtr
App Item (b)/ Filter media 3mm to 6mm in 2nd layer 15 cm.
App Item (c)/ Filter media 6mmto 12mm in 3rd layer 15mm
App Item (d)/ Filter media 12mm to 20mm in 4th layer 15cm
App Item (e)/ Stone gravel size 20mmto 40mm gauge 15cm
App Item (f)/ Stone gravel size 40mm to 50mm gauge 15cm
App Item/ Dismantling 100mm dia G.I. pipes and 63mm O/D PVC pipes diffusers and fitting them including leveling , testing and commissioning of lateral tees, 100mm I/d pipes & holes , repairing connection with cement concrete , cleaning of channel complete in all respect.
App Item/ Providing laying and placing in layers of all kind filter media duly washed screened & graded in horizontal layers to complete the required thickness. (a) Stone gravel 40mm to 50mm
App Item (b)/ Stone gravel size 20mm to 400 mm gauge
App Item (c)/ Filter media 12mm to 20mm in 4th layer
App Item (d)/ Filter median 6mm to 12mm in 3rd layer
App Item (e)/ Filter media 6mm to 12 mm in 2nd layer
App Item (f)/ Providing , placing & testing of quartz sand filter media duly screened, cleaned , washed , and graded from Jhansi only as per specification for rapid sand , filter media shall consist suitably graded best quality sand with effective size 0.45mm to 0.65mm and uniformly co-efficient of 1:3 to 1:7 and shall have silica contents not less than 99.8% and specific gravity between 2.55 and 2.65 as per ISI specification.
App Item/ Providing , fixing & testing of GI pipe 100mm I/d for Air Compressor C- class including cost of elbow , sockets draining Welded & screened joint at each filter making holes of required size for fixing in RCC tees clamped with MS clamp, & repairing of RCC precast slab to make leak proof joint .
App Item/ Providing, and fixing 63mm o/d PVC pipe for diffusers with 3 Nos. holes at 30 degree at 6 inch each including U clamps, end cap, fixing in C.C. and leaving for proper and uniform air. Length of pipe is as per site condition and distance between two pipes will chamber size is 300mm and filter media chamber size is 3 Mtr. X 4 Mtr. total Nos. of filter media chamber.
NS Item/ Providing and fixing of 1 HP motor and gear box with coupling and foundation frame
NS Item/ New star delta starter plain for 20 HP motor for compressor complete
NS Item/ Providing and fixing of Air filter set for compressing in backwash unit
NS Item/ Complete Wiring for compressing room and back wash chamber etc.
NS Item/ Repairing and servicing all sluice valves of 200mm dia including repair of check nuts, spindle, seal/disc etc. complete.
NS Item/ Prociding and fixing of 100mm sluice valve for back wash (IVC Make) complete
NS Item/ Cleaning & Desilting of garbage from alum section complete in all respect
NS Item/ Repairing of alum mixing unit in all respect including and fixing of new shaft.
NS Item/ Providng and fixing of New compressor of 500 CFM 0.035 Kg / cm2
NS Item/ Providing and fixing of 200mm i/d sluice valve at Inlet (IVC Make)
NS Item/ Providing and fixing of Motor and pump set for back wash of 15 HP Capacity make kirloskar, crompton and kishor etc
NS Item/ Providing and fixing of 3 HP motor with pump (3 Phase) complete with foundation make kirloskar, crompton and kishor etc
NS Item/ Repairing of 7.5 HP motor and pump for backwash system
THE JAGRAM BASS COOP L/C SOCIETY LTD.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .