Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.7 LAccepted-AOC C O PRAMOD KUMAR SHAH BUS STAND NANDPRAYAG NANDPRAYAG CHAMOLI UTTARAKHAND 246429 | NANDPRAYAG | CHAMOLI | UTTARAKHAND | 246429 | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹13.0 L+₹7,375 (0.57%)Rejected-Finance | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹15.1 L+₹2.3 L (17.5%)Rejected-Finance | L3 | Rejected-Finance NOT LOWEST | |
| 4 | L4₹16.5 L+₹3.6 L (27.7%)Rejected-Finance 227 NEW GANESH VIHAR ADARSH MILL ROAD GHOSIPURA LASHKAR GWALIOR 474012 M P | GWALIOR | MADHYA PRADESH | 474012 | L4 | Rejected-Finance NOT LOWEST | |
| 5 | L5₹17.9 L+₹5.0 L (38.9%)Rejected-Finance C 187 NIRMAN VIHAR DELHI 92 | L5 | Rejected-Finance NOT LOWEST |
Tender Value
₹14.5 L
EMD Value
₹29,000
Closing Date
23 Mar 2022, 6:00 pmClosed
GE AF ADM AREA GWALIOR
AIR FORCE STATION GWALIOR
SPECIAL REPAIR REPLACEMENT OF OH CONDUCTOR TO UG CABLES IN RESIDENCY MESS AT AF STATION GWALIOR
2022_MES_509815_1
8191/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AIR FORCE STATION GWALIOR
Class E and above and category b(i)
8 documents required · 8 mandatory
₹500
AIR FORCE STATION GWALIOR
₹29,000
Yes
30 Mar 2022
23 Feb 2022
26 Mar 2022
23 Feb 2022
23 Mar 2022
9 Mar 2022
23 Feb 2022 - 2 Mar 2022
Amount
Dismantling & taking down of existing worn out / unserviceable aluminium conductor, steel reinforced (ACSR) of any description /size & in any position from existing LT/HT Poles/Lines all as specified & directed.
Excavation in trenches in soft & loose soil not exceeding 1.5 metre deep and not exceeding 1.5 mtr width and getting out soil including forming bottom surface to required slope/gradient for laying cables/pipes etc. all as specified and directed including removing cable protection PCC covers/ bricks & stacking serviceable covers / bricks for reuse and disposal of unserviceable covers within 50 m all as directed.Note : Excavation shall be made carefully in order to avoid damage of existing cables and protection covers.
Returning, filling in including spreading, leveling, watering and well ramming in layers of 25 cm thick after the cables etc. are laid, jointed & tested complete all as specified and directed.
Removal of surplus excavated spoil not exceeding 50 Mtr distance and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified.
Supply and lay for sand filling with clean dry find sand unwashed including gently punning around cables in trenches for cable protection complete all as specified and directed. NOTE:- For measurement purpose punned thickness shall be considered as per clause 19.75 of SSR Part-I
Supplying & Laying Sub Class `B’ bricks old size with axis of the bricks perpendicular to the axis of the cable as in cable protection all as specified and directed.
Disconnecting, taking out and removing old existing unserviceable/repairable underground, LT cable of any description and in any position complete including taking down protection pipe,bricks etc all as specified and directed for the following sizes: Note : Excavation /earth work shall be measerd and paid to seperately under relevant items of Sch.
(a) 10 Sqmm to 25 Sqmm any core
(b) 35 Sqmm to 70 Sqmm 3½ core
(c) 95 Sqmm to 150 Sqmm 3½ core
(d) 185 Sqmm to 300 Sqmm 3½ core
Laying, jointing and testing XLPE / P.V.C insulated, armoured, heavy duty, aluminum conductor cable 1100 volts grade of any description and any make laid in trenches/ducts, floors, fixed to walls etc. complete all as specified and directed for the following sizes :- .(NOTE : (i) Old retrieved cables received in serviceable condition from taking down shall be used in the work.
(a) 10 Sqmm to 25 Sqmm any core
(b) 35 Sqmm to 70 Sqmm 3½ core
(c) 95 Sqmm to 150 Sqmm 3½ core
(d) 185 Sqmm to 300 Sqmm 3½ core
Supplying ,Laying, jointing and testing XLPE insulated, armoured, heavy duty, aluminum conductor cable 1100 volts grade ISI marked ,laid in trenches/ducts, floors, fixed to walls etc. complete all as specified and directed for the following sizes :-. MAKE:- Make : Havells Cable/National Cable Co/CCI/Gloster/Asian Cables/Incab/Finolex
(a) 10 Sqmm 2 core
(b) 16 Sqmm 4 core
(c) 35 Sqmm 3½ core
(d ) 70 Sqmm 3½ core
(e) 120 Sqmm 3½ core
(f) 150 Sqmm 3½ core
(g) 185 Sqmm 3½ core
M & L in repair jointing and testing for provision of straight through joints, heat shrinkable, suitable for XLPE, LT UG Cable, 1100 Volts grade, for size 10 Sqmm to 16 Sqmm any core complete all as specified and directed by the Engineer-in-Charge. MAKE:- M.SEAL/DENSON/3M,REPL/MAHINDRA CHEMICAL
M & L in repair jointing and testing for provision of straight through joints, heat shrinkable, suitable for XLPE, LT UG Cable, 1100 Volts grade, for size 25 Sqmm to 50 Sqmm ,3.5 core complete all as specified and directed by the Engineer-in-Charge. MAKE:- M.SEAL/DENSON/3M,REPL/MAHINDRA CHEMICAL
M & L in repair jointing and testing for provision of straight through joints, heat shrinkable, suitable for XLPE, LT UG Cable, 1100 Volts grade, for size 70 Sqmm to 120 Sqmm, 3.5 core complete all as specified and directed by the Engineer-in-Charge. MAKE:- M.SEAL/DENSON/3M,REPL/MAHINDRA CHEMICAL
M & L in repair jointing and testing for provision of straight through joints, heat shrinkable, suitable for XLPE, LT UG Cable, 1100 Volts grade, for size 150 Sqmm to 185 Sqmm ,3.5 core complete all as specified and directed by the Engineer-in-Charge. MAKE:- M.SEAL/DENSON/3M,REPL/MAHINDRA CHEMICAL
Demolition for cement concrete/road in ground floor and paving not exceeding 15 cm thickness below or above ground level including removal of rubbish to a distance exceeding 1.50 Km but not exceeding 5.00 Km etc complete all as specified and directed.
M & L in replacement rusted pipe, laying & jointing 100 mm bore GI water tubing, light grade as in sleeving etc laid in trenches / ducts / horizontal bore hole complete all as specified and directed by Engineer-in-Charge. MAKE:- TATA/JINDAL/SWASTIK
M & L in replacement rusted pipe, laying & jointing 50 mm bore GI water tubing, light grade as in sleeving etc laid in trenches / ducts / horizontal bore hole complete all as specified and directed by Engineer-in-Charge. MAKE:- TATA/JINDAL/SWASTIK
M&L for PCC 1:4:8, type D-2 (using 40mm graded crushed stone aggregate) as in foundation/repairs to damaged road/footpath/plinth for panels etc. including necessary formwork complete all as specified & directed.
M&L for PCC 1:2:4,type B-1 (using 20mm graded crushed stone aggregate) as in repair to footpath/hard standing/plinth for panels etc. including necessary formwork complete all as specified & directed.
Supply, Installation, testing factory made LT Feeder Pillar Box (of size 60 cmx45cmx30cm for 3 Phase, 4 Wire, 415 Volts, AC, 50 Hz, Outdoor, Cubical Type, Weather, Dust and Vermin proof, Pedestal mounting type, front operated applications having size of Aluminium bus bar rating capacity 400 Amps and neutral 300 Amps rating capacity mounting of insulators, Controlled by MCCB, 100 Amps, 3 pole, 415 Volts, AC supply, having breaking capacity Icu = 16 KA fixed type, on incomming side, canopy on top and gland provision in the bottom made out of 3.15 mm thick MS sheet duly powder coated of approved shade with using 40mmX40mmX6 mm angle iron frame and supports including necessary excavation and grouting work in PCC 1:2:4 Mix, Type B1 complete all as specified and directed.
Supplying and fixing in position new PVC (Sinthetic) boxes of size 280mm X 170mm X 115mm depth, made out with Sinthetic. The box shall be provided with and including 10 cm long aluminium bus bar of size 20x3 mm size 2 Nos mounted on porcelain insulators including one No. MCB SP of ‘C’ series, 5/6 Amps of Make Legrand/L&T/ Siemens and connecting the bus bars to cables with using suitable GI nut, bolts and washers and aluminum lugs etc fixed on pole using 30x5 mm GI clamps, nuts, bolts & washers etc complete all as specified and directed by Engineer-in-Charge. (Note :- The contractors quoted rates for the above items are deemed to include for fixing the Synthetic box in position with suitable MS clamps and/or necessary PCC as per site requirement.)
M & L for earthing complete with Gl electrode of size 600 mm x 600 mm x 6.00mm thick buried directly in ground vertically in pit of depth not less than 2.25 mtr below normal ground level with top edge of the earth plate not less than 1.50 mtr below normal ground level connected to Gl earth strip 32 mm X6 mm as main earthing lead by means of bolts, nuts, check nuts and washers of brass connected including gun metal or phosphorus bronze of size 75x75x25 mm drilled and screwed including 3 Nos 8 mm dia 25 mm long hexagonal head screwed all as specified including excavation and earth work and disposal of surplus soil including 40 mm dia Gl tubing light grade and necessary fitting for protection of Gl strip including laying of charcoal, dust and common salt PCC (1:3:6) type C-l( using 20 mm graded crushed stone aggregate) earth pit with 40x40x3mm mild steel angle iron frame & 40mm thick pre cast RCC cover (1:2:4) type B-1 (using 20 mm graded crushed stone aggregate) reinforced with 8mm dia TMT bars @ 75mm C/C both way with mild steel handle 12 mm dia round bars ,10mm thick plastering with cement mortar (1:4) internally and upto 150 mm below ground level externally, PGI funnel with wire mesh 20mm dia Gl pipe for watering complete all as shown on electrical plate No.3 of SSR Part -1 2009 and connected in earth test including testing completed all specified and directed. Note: (i) Earth strip and its protection pipe up to and including 7.5 mtr only from the top of earth electrode are included in this item. (ii) Test result of earthing to be submitted by the contractor for all earthing. (iii) Earth filling shall be done by vegetable soil. (iv) Soil should be free from stone, boulders,aggragates,gravel etc. (v) The rate quoted by the bidders shall be also be deemed to include :-(a) Excavation upto 5 mtr depth and returning filling in any type of soil and disposal of surplus soil. (b) Supply of charcoal and common salt.
M & L for earthing complete with Gl electrode of size 600 mm x 600 mm x 6.00mm thick buried directly in ground vertically in pit of depth not less than 2.25 mtr below normal ground level with top edge of the earth plate not less than 1.50 mtr below normal ground level connected to Gl wire 4mm dia as main earthing lead by means of bolts, nuts, check nuts and washers of brass connected including gun metal or phosphorus bronze of size 75x75x25 mm drilled and screwed including 3 Nos 8 mm dia 25 mm long hexagonal head screwed all as specified including excavation and earth work and disposal of surplus soil including 15 mm dia Gl tubing light grade and necessary fitting for protection of Gl strip including laying of charcoal, dust and common salt PCC (1:3:6) type C-l( using 20 mm graded crushed stone aggregate) earth pit with 40x40x3mm mild steel angle iron frame & 40mm thick pre cast RCC cover (1:2:4) type B-1 (using 20 mm graded crushed stone aggregate) reinforced with 8mm dia TMT bars @ 75mm C/C both way with mild steel handle 12 mm dia round bars ,10mm thick plastering with cement mortar (1:4) internally and upto 150 mm below ground level externally, PGI funnel with wire mesh 20mm dia Gl pipe for watering complete all as shown on electrical plate No.3 of SSR Part -1 2009 and connected in earth test including testing completed all specified and directed. Note: (i) Earth strip and its protection pipe up to and including 7.5 mtr only from the top of earth electrode are included in this item. (ii) Test result of earthing to be submitted by the contractor for all earthing. (iii) Earth filling shall be done by vegetable soil. (iv) Soil should be free from stone, boulders,aggragates,gravel etc. (v) The rate quoted by the bidders shall be also be deemed to include :-(a) Excavation upto 5 mtr depth and returning filling in any type of soil and disposal of surplus soil. (b) Supply of charcoal and common salt.
S&F PVC insulated, sheathed twin core 2.5 Sqmm size aluminium wire duly passing through the holes of existing steel poles/ street light brackets including necessary connection at pole mounted street light junction box and at the street light luminaries all as specified and directed.
M&L for making two holes (each hole of 20 mm dia) in existing street light steel tubular pole by using gas welding/ electric arc welding for insertion of wire for street lights. The holes should be made first at 1500 mm above ground level and second 1200 mm below top end of the pole including grinding the surface of pole for proper smoothness all as specified and directed.
Om Electricals
m/s A.A brothers
M/s KKPARASHAR
M/S KAPIL CONSTRUCTION CO
Mukesh Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .